Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Sensors (Basel) ; 19(13)2019 Jun 28.
Article in English | MEDLINE | ID: mdl-31261674

ABSTRACT

Performance evaluations and corrections of soil water sensors have not been studied using different installation orientations under various irrigation treatments in the Texas High Plains. This study evaluated the performance of four sensors using factory calibration and derived field corrections as compared to calibrated neutron moisture meters (NMMs). Sensor performance was assessed using horizontal insertion, laid horizontal placement, and vertical insertion at 15.2, 45.7, and 76.2 cm depths in a clay loam soil with three irrigation treatments. Results indicated the factory-calibrated Acclima 315 L performed satisfactorily using horizontal insertion as compared to NMM measurements at 45.7 and 76.2 cm depths with a ±2% mean difference (MD) and <3.5% root mean square error (RMSE). The factory-calibrated Acclima 315 L using horizontal insertion also performed satisfactorily across all irrigation treatments according to soil profile water storage (MD = 0.36% and RMSE = 3.25%). Generally, the factory-calibrated Decagon GS1 and Campbell Scientific 655 using vertical insertion agreed more closely with NMM measurements compared with other installation orientations. There was a significant underestimation of water storage (>60 mm) in the 0.9 m soil profile using the Watermark 200SS. In summary, field corrections are required for Decagon GS1, Campbell Scientific 655, and Watermark 200SS sensors.

2.
Sensors (Basel) ; 17(10)2017 Oct 14.
Article in English | MEDLINE | ID: mdl-29036926

ABSTRACT

Accurate estimates of actual crop evapotranspiration (ET) are important for optimal irrigation water management, especially in arid and semi-arid regions. Common ET sensing methods include Bowen Ratio, Eddy Covariance (EC), and scintillometers. Large weighing lysimeters are considered the ultimate standard for measurement of ET, however, they are expensive to install and maintain. Although EC and scintillometers are less costly and relatively portable, EC has known energy balance closure discrepancies. Previous scintillometer studies used EC for ground-truthing, but no studies considered weighing lysimeters. In this study, a Surface Layer Scintillometer (SLS) was evaluated for accuracy in determining ET as well as sensible and latent heat fluxes, as compared to a large weighing lysimeter in Bushland, TX. The SLS was installed over irrigated grain sorghum (Sorghum bicolor (L.) Moench) for the period 29 July-17 August 2015 and over grain corn (Zea mays L.) for the period 23 June-2 October 2016. Results showed poor correlation for sensible heat flux, but much better correlation with ET, with r² values of 0.83 and 0.87 for hourly and daily ET, respectively. The accuracy of the SLS was comparable to other ET sensing instruments with an RMSE of 0.13 mm·h-1 (31%) for hourly ET; however, summing hourly values to a daily time step reduced the ET error to 14% (0.75 mm·d-1). This level of accuracy indicates that potential exists for the SLS to be used in some water management applications. As few studies have been conducted to evaluate the SLS for ET estimation, or in combination with lysimetric data, further evaluations would be beneficial to investigate the applicability of the SLS in water resources management.

4.
Sensors (Basel) ; 8(8): 5186-5201, 2008 Aug 28.
Article in English | MEDLINE | ID: mdl-27873809

ABSTRACT

Agriculture on the Texas High Plains (THP) uses approximately 89% of groundwater withdrawals from the Ogallala Aquifer. Consequently, groundwater levels are declining faster than the recharge rate. Therefore, efficient agricultural water use is essential for economic viability and sustainability of the THP. Accurate regional evapotranspiration (ET) maps would provide valuable information on actual crop water use. In this study, METRIC (Mapping Evapotranspiration at High Resolution using Internalized Calibration), a remote sensing based ET algorithm, was evaluated for mapping ET in the THP. Two Landsat 5 Thematic Mapper images acquired on 27 June (DOY 178) and 29 July (DOY 210) 2005 were used for this purpose. The performance of the ET model was evaluated by comparing the predicted daily ET with values derived from soil moisture budget at four commercial agricultural fields. Daily ET estimates resulted with a prediction error of 12.7±8.1% (mean bias error ± root mean square error) on DOY 178 and -4.7±9.4% on DOY 210 when compared with ET derived from measured soil moisture through the soil water balance. These results are good considering the prevailing advective conditions in the THP. METRIC have the potential to be used for mapping regional ET in the THP region. However, more evaluation is needed under different agroclimatological conditions.

SELECTION OF CITATIONS
SEARCH DETAIL