Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Rev. calid. asist ; 32(3): 166-171, mayo-jun. 2017. tab
Article in Spanish | IBECS | ID: ibc-162455

ABSTRACT

Objetivos. Conocer el grado de satisfacción y las características sociodemográficas de las pacientes a las que se les realiza la técnica epidural para el trabajo de parto. Material y métodos. Encuesta SERVQHOS administrada con muestreo consecutivo a 140 pacientes que habían recibido técnica anestésica epidural para el control del dolor de parto desde enero hasta junio de 2014 en el Hospital San Pedro. Resultados. Recogidas 140 encuestas. La satisfacción media global (SERVQHOS): 4,4 con desviación estándar (DE):±0,9 con mejor resultado en preguntas subjetivas: (4,3; DE: 0,8) que objetivas (4; DE: 0,9). El 84,3% se mostraron satisfechas con la analgesia epidural y 100% volverían a solicitarla. No hemos encontrados diferencias significativas en relación con la satisfacción con la epidural ni con la percepción del dolor con variables sociodemográficas (edad, nacionalidad, situación laboral, nivel de estudios o estado civil). El 85% (119) eran mujeres españolas y el 14,3%(20) pertenecían a otras nacionalidades. Una paciente no respondió. Respecto al estado civil: 79,3% (111) estaban casadas, 16,4% (23) eran solteras, 1,4% (2) eran viudas o separadas y no contestaron el 2,9% (4). La edad media fue 33,3 (DE: 4.4). Antes de administrar la analgesia epidural, el 93,2% de las españolas definieron el dolor del parto como grave frente al 95% de las mujeres extranjeras pero sin encontrarse diferencias estadísticamente significativas (p=0,279). Conclusiones. La proporción de pacientes satisfechas con la técnica fue muy elevada, siendo los aspectos subjetivos los mejor valorados (trato y confianza en profesionales) (AU)


Background. To determine the level of satisfaction and the sociodemographic characteristics of patients who receive epidural analgesia during labour. Material and Methods. A SERVQHOS questionnaire administered, with consecutive sampling, to 140 patients who had received an epidural anaesthetic for pain control during labour between January and June 2014, at the Hospital San Pedro. Results. A total of 140 questionnaires were completed. The mean overall satisfaction (SERVQHOS scale) was 4.4 with standard deviation (SD):±0.9, with the best results being obtained in the subjective ítems: (4.3; SD 0.81) compared to the objective ítems (4; SD: 0.9). The large majority (84.3%) showed satisfaction with the epidural anaesthetic, and 100% would ask for it again. No significant differences were found in epidural satisfaction or pain perception related to socioeconomic variables (age, nationality, employment conditions, education level or marital status). As regards nationality, 119 (85%) were Spanish, and 14.3% (20) of other nationalities, with 1 patient not answering the nationality question. As regards marital status, 79.3% (111) were married, 1.4% (2), single, and 2.9% (4) were widows or separated, and 2.9% (4) did not answer. The mean age was 33.3 years (SD: 4.4). Prior to the administration of the epidural anaesthetic 93.2% of the Spanish citizens group described the pain as severe compared to 95% of the other nationalities group, but this difference had no statistical significance (p=.279). Conclusion. The level of satisfaction reported by the patients with this technique was high, with subjective items (good manners and trust) being appreciated more (AU)


Subject(s)
Humans , Female , Pregnancy , Analgesia, Epidural/statistics & numerical data , Analgesia, Obstetrical/statistics & numerical data , Labor Pain/drug therapy , Patient Satisfaction/statistics & numerical data , Labor, Obstetric
SELECTION OF CITATIONS
SEARCH DETAIL
...