1.
J Magn Reson ; 287: 113-122, 2018 02.
Article in English | MEDLINE | ID: mdl-29335164

ABSTRACT

A novel slice-selective T1-T2 measurement is proposed to measure spatially resolved T1-T2 distributions. An adiabatic inversion pulse is employed for slice-selection. The slice-selective pulse is able to select a quasi-rectangular slice, on the order of 1 mm, at an arbitrary position within the sample.The method does not employ conventional selective excitation in which selective excitation is often accomplished by rotation of the longitudinal magnetization in the slice of interest into the transverse plane, but rather a subtraction based on CPMG data acquired with and without adiabatic inversion slice selection. T1 weighting is introduced during recovery from the inversion associated with slice selection. The local T1-T2 distributions measured are of similar quality to bulk T1-T2 measurements. The new method can be employed to characterize oil-water mixtures and other fluids in porous media. The method is beneficial when a coarse spatial distribution of the components is of interest.

2.
J Magn Reson ; 278: 104-112, 2017 05.
Article in English | MEDLINE | ID: mdl-28388495

ABSTRACT

Slice-selective pulsed field gradient (PFG) and PFG-T2 measurements are developed to measure spatially-resolved molecular diffusion and diffusion-T2 distributions. A spatially selective adiabatic inversion pulse was employed for slice-selection. The slice-selective pulse is able to select a coarse slice, on the order of 1cm, at an arbitrary position in the sample. The new method can be employed to characterize oil-water mixtures in porous media. The new technique has an inherent sensitivity advantage over phase encoding imaging based methods due to signal being localized from a thick slice. The method will be advantageous for magnetic resonance of porous media at low field where sensitivity is problematic. Experimental CPMG data, following PFG diffusion measurement, were compromised by a transient ΔB0(t) field offset. The off resonance effects of ΔB0(t) were examined by simulation. The ΔB0 offset artifact in D-T2 distribution measurements may be avoided by employing real data, instead of magnitude data.

3.
Rev Sci Instrum ; 88(12): 123703, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29289224

ABSTRACT

A metallic core holder, fabricated from non-magnetic Hastelloy-C276, has been designed for Magnetic Resonance (MR) and Magnetic Resonance Imaging (MRI) of core plug samples at high pressures and temperatures. Core plug samples, 1.5″ in diameter and 2″ in length, can be tested in the core holder at elevated pressures and temperatures, up to 5000 psi and 80 °C. These are conditions commonly found in petroleum reservoirs. A radio frequency probe, which excites and detects magnetic resonance signals, was placed inside the metal vessel. Proximity to the sample improves the signal to noise ratio of the resulting measurements. The metallic core holder is positioned between the poles of a 0.2 T permanent magnet and subjected to rapidly switched magnetic field gradients as part of the imaging process. This switching induces eddy currents on the conductive core holder, which degrades the magnetic field gradient waveform in the sample space. The low electrical-conductivity of Hastelloy-C276 minimizes the duration and the magnitude of such eddy currents. A recently developed pre-equalization technique was employed to ensure that magnetic field gradient pulses, required for MRI, are near ideal in the sample space. A representative core flooding experiment was undertaken in conjunction with MR/MRI measurements.

4.
J Magn Reson ; 178(1): 136-41, 2006 Jan.
Article in English | MEDLINE | ID: mdl-16216540

ABSTRACT

Density weighted, centric scan, Conical SPRITE MRI techniques are applied in the current work for local porosity measurements in fluid saturated porous media. The methodology is tested on a series of sandstone core samples. These samples vary in both porosity and degree of local heterogeneity due to bedding plane structure. The MRI porosity measurement is in good agreement with traditional gravimetric measurements of porosity. Spatially resolved porosity measurements reveal significant porosity variation in some samples. This novel MRI technique should have applications to the characterization of local porosity in a wide variety of porous media.

5.
Solid State Nucl Magn Reson ; 23(1-2): 28-49, 2003.
Article in English | MEDLINE | ID: mdl-12633830

ABSTRACT

An exact expression for the cross polarization between two spin-1/2 particles is derived from the quantum Liouville equation. This is given in the form of two integrodifferential equations. These can be solved exactly in the static case (no sample spinning) and a powder average easily performed numerically. With magic-angle spinning, the neglect of certain interference terms simplifies the numerical calculation. A further assumption decoupling the calculation of the sidebands gives a very simple formula that is capable of giving a qualitative interpretation of all experimental observations. Examples are given illustrating typical buildup curves and CPMAS matching profiles.