ABSTRACT
The LC-MS/MS method for determination of the anti-epileptic drug topiramate (TPM) in human plasma was developed and validated for pharmacokinetic and bioequivalence study purposes. For quantitative determination of TPM values the method with deuterated internal standard (topiramate-d12) and liquid chromatography with tandem mass spectrometry was used. TPM was extracted from the human plasma using the solid-phase extraction procedure on a Strata X extraction column. Negative ions were monitored in the selected reaction monitoring mode (SRM) and transitions m/z 338.2 > 78.2 and m/z 350.3 > 78.2 were used for the quantitative evaluation of TPM and the internal standard, respectively. The results obtained from validation were statistically evaluated according to the requirements of European Medicines Agency (EMA) and Food and Drug Administration (FDA) regulatory guidelines. The linearity of the method was checked within a concentration range from 10 to 2000 ng/mL. Successful validation confirmed that this method is precise, accurate, sensitive and therefore suitable for determination of topiramate plasma levels in pharmacokinetic and bioequivalence studies.
Subject(s)
Fructose/analogs & derivatives , Chromatography, High Pressure Liquid , Fructose/blood , Fructose/chemistry , Humans , Molecular Structure , Tandem Mass Spectrometry , TopiramateABSTRACT
An LC-MS/MS method for determination of the anti-epileptic drug topiramate (TPM) in dried blood spot (DBS) samples was developed and validated. DBS samples were prepared by spotting 30 µL of spiked whole blood onto FTA(TM) DMPK-C cards and drying for at least 3 h. Six-millimetre punched spots were then extracted by using a mixture of methanol and water (90:10, v/v) with deuterated internal standard (topiramate-d12). The extracted samples were injected into a liquid chromatograph equipped with a tandem mass spectrometric detector. Negative ions were monitored in the selected reaction monitoring mode and transitions m/z 338.2 â 78.1 and m/z 350.3 â 78.1 were used for the quantitative evaluation of TPM and internal standard, respectively. The results obtained from validation were statistically evaluated according to the requirements of the European Medicines Agency and US Food and Drug Administration regulatory guidelines. The linearity of the method was checked within a concentration range from 10 to 2000 ng/mL. The validation results indicate that the method is accurate, precise, sensitive, selective and reproducible.