Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
2.
Am J Infect Control ; 41(1): 89-91, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22722007

ABSTRACT

This hospital-wide assessment of central venous catheter (CVC) site maintenance evaluated a total of 420 CVC sites and found deficiencies in 31%. Internal jugular CVC dressings were the most frequently deficient type (P = 0.001). No correlation between CVC site maintenance and central line-associated bloodstream infections was detected (Spearman's correlation coefficient = 0.007; P = 0.98).


Subject(s)
Bandages , Catheter-Related Infections/prevention & control , Central Venous Catheters/adverse effects , Guideline Adherence/statistics & numerical data , Infection Control/methods , Catheter-Related Infections/epidemiology , Health Services Research , Hospitals , Humans
3.
Infect Control Hosp Epidemiol ; 29(5): 424-9, 2008 May.
Article in English | MEDLINE | ID: mdl-18419364

ABSTRACT

OBJECTIVE: To characterize infection control experience during a 6.5-year period in a cooperative care center for transplant patients. DESIGN: Descriptive analysis. SETTING: A cooperative care center for transplanted patients, in which patients and care partners are housed in a homelike environment, and care partners assume responsibility for patient care duties. PATIENTS: Nine hundred ninety one transplant patients. METHODS: Infection control definitions from the Centers for Disease Control and Prevention were used to ascertain infection rates. Environmental cultures were used to detect methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus (VRE), Clostridium difficile, and fungi during the first 18 months. Surveillance cultures were performed for a subset of patients and care partners. RESULTS: From June 1999 through December 2005, there were 19,365 patient-days observed. The most common healthcare-associated infection encountered was intravascular catheter-related bloodstream infection, with infection rates of 5.74 and 4.94 cases per 1,000 patient-days for hematopoietic stem cell transplant (HSCT) and solid organ transplant (SOT) patients, respectively. C. difficile-associated diarrhea was observed more frequently in HSCT patients than in SOT patients (3.97 vs 0.57 cases per 1,000 patient-days; P < .0001). There was no evidence of environmental contamination with MRSA, VRE, or C. difficile. Acquisition of MRSA was not observed. Acquisition of VRE was documented. CONCLUSION: This study documented that cooperative care was associated with some risk of healthcare-associated infection, most notably intravascular catheter-associated bloodstream infection and C. difficile-associated diarrhea, it appears the incidences of these infections were roughly commensurate with those in other care settings.


Subject(s)
Bacteremia/epidemiology , Catheterization, Central Venous/adverse effects , Cooperative Behavior , Cross Infection/epidemiology , Delivery of Health Care/methods , Hematopoietic Stem Cell Transplantation , Infection Control/methods , Organ Transplantation , Bacteremia/microbiology , Bacteremia/prevention & control , Clostridioides difficile/isolation & purification , Cross Infection/microbiology , Cross Infection/prevention & control , Diarrhea/epidemiology , Diarrhea/microbiology , Diarrhea/prevention & control , Gram-Negative Bacteria/isolation & purification , Gram-Positive Cocci/isolation & purification , Hematopoietic Stem Cell Transplantation/adverse effects , Humans , Incidence , Organ Transplantation/adverse effects
4.
Infect Control Hosp Epidemiol ; 29(1): 8-15, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18171181

ABSTRACT

BACKGROUND: There are limited data from prospective studies to indicate whether improvement in hand hygiene associated with the use of alcohol-based hand hygiene products results in improved patient outcomes. DESIGN: A 2-year, prospective, controlled, cross-over trial of alcohol-based hand gel. SETTING: The study was conducted in 2 medical-surgical ICUs for adults, each with 12 beds, from August 2001 to September 2003 at a university-associated, tertiary care teaching hospital. METHODS: An alcohol-based hand gel was provided in one critical care unit and not provided in the other. After 1 year, the assignment was reversed. The hand hygiene adherence rate and the incidence of nosocomial infection were monitored. Samples for culture were obtained from nurses' hands every 2 months. RESULTS: During 17,994 minutes of observation, which included 3,678 opportunities for hand hygiene, adherence rates improved dramatically after the introduction of hand gel, increasing from 37% to 68% in one unit and from 38% to 69% in the other unit (P< .001). Improvement was observed among all groups of healthcare workers. Hand hygiene rates were better at higher workloads when hand gel was available in the unit (P= .02). No substantial change in the rates of device-associated infection, infection due to multidrug-resistant pathogens, or infection due to Clostridium difficile was observed. Culture of samples from the hands of nursing staff revealed that an increased number of microbes and an increased number of microbe species was associated with longer fingernails (ie, more than 2 mm long), the wearing of rings, and/or lack of access to hand gel. CONCLUSIONS: The introduction of alcohol-based gel resulted in a significant and sustained improvement in the rate of hand hygiene adherence. Fingernail length greater than 2 mm, wearing rings, and lack of access to hand gel were associated with increased microbial carriage on the hands. This improvement in the hand hygiene adherence rate was not associated with detectable changes in the incidence of healthcare-associated infection.


Subject(s)
Anti-Infective Agents, Local , Cross Infection/prevention & control , Ethanol , Gels , Hand Disinfection/methods , Intensive Care Units , Adult , Bacteria/drug effects , Bacteria/growth & development , Bacteria/isolation & purification , Bacterial Infections/microbiology , Bacterial Infections/prevention & control , Colony Count, Microbial , Cross Infection/microbiology , Cross-Over Studies , Drug Resistance, Multiple, Bacterial , Guideline Adherence , Hand/microbiology , Hand Disinfection/standards , Humans , Microbial Viability/drug effects , Personnel, Hospital , Prospective Studies
5.
Clin Infect Dis ; 44(11): 1408-14, 2007 Jun 01.
Article in English | MEDLINE | ID: mdl-17479934

ABSTRACT

BACKGROUND: Needleless intravascular catheter connector valves have been introduced into clinical practice to minimize the risk of needlestick injury. However, infection-control risks associated with these valves may be underappreciated. In March 2005, a dramatic increase in bloodstream infections was noted in multiple patient care units of a hospital in temporal association with the introduction of a needleless valve into use. METHODS: Surveillance for primary bloodstream infection was conducted using standard methods throughout the hospital. Blood culture contamination rates were monitored. Cultures were performed using samples obtained from intravascular catheter connector valves. RESULTS: The relative risk of bloodstream infection for the time period in which the suspect connector valve was in use, compared with baseline, was 2.79 (95% confidence interval, 2.27-3.43). In critical care units, the rate of primary bloodstream infection increased with the introduction of the valve from 3.87 infections per 1000 catheter-days to 10.64 infections per 1000 catheter-days (P<.001), and it decreased to 5.59 infections per 1000 catheter-days (P=.02) in the 6 months following removal of the device from use. Similarly, in inpatient nursing units, the rate of bloodstream infection increased from 3.47 infections per 1000 catheter-days to 7.3 infections per 1000 catheter-days (P=.02) following introduction of the device, and it decreased to 2.88 infections per 1000 catheter-days (P=.57) following removal of the device from use. Similar events occurred in the cooperative care units. The rate of blood culture contamination did not substantially change over the course of the study. Of 37 valves that were subjected to microbiological sample testing, 24.3% yielded microbes, predominantly coagulase-negative staphylococci. CONCLUSION: A significant association between primary bloodstream infection and a needleless connector valve was observed. Evaluation of needleless connector valves should include a thorough assessment of infection risks in prospective randomized trials prior to their introduction to the market.


Subject(s)
Bacteremia/epidemiology , Bacteremia/etiology , Catheterization/instrumentation , Disease Outbreaks , Equipment Contamination , Humans , Risk Factors
6.
Am J Infect Control ; 32(8): 445-50, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15573050

ABSTRACT

BACKGROUND: Urinary tract infections (UTIs) are the most common nosocomial infection experienced by patients in United States hospitals and are responsible for significant morbidity and excess hospital costs. The purpose of this study was to determine the efficacy of a silver alloy, hydrogel-coated, urinary catheter in the prevention of catheter-associated UTI, to assess the cost effectiveness of the coated catheter, and to test for the emergence of silver-resistance in urinary microbial isolates. METHODS: A 2-year prospective surveillance study in 10 patient care units was conducted to determine the rate of catheter-associated UTI. Historic control data was utilized to assess the effect of the coated catheter. A cost-effectiveness analysis was conducted using a range of cost estimates. Silver susceptibility was determined for microbes responsible for catheter-associated UTI. RESULTS: Data were analyzed using a Poisson regression model. The rate of catheter-associated UTI fell from 6.13/1000 catheter-days during the period 1999-2000 to 2.62/1000 catheter-days during 2001-2002 ( P = .002). Calculated cost savings varied widely. Modest savings were achieved at the realistic lower cost estimates. No silver-resistant microbes were recovered in the susceptibility tests. CONCLUSIONS: The introduction of a silver alloy, hydrogel-coated urinary catheter was associated with a significant decline in nosocomial UTI and cost savings over the range of cost estimates. Silver-resistant urinary pathogens were not recovered from patients experiencing catheter-associated UTI during the study period.


Subject(s)
Silver/therapeutic use , Urinary Catheterization/instrumentation , Anti-Bacterial Agents/therapeutic use , Bacteria/drug effects , Bacteria/isolation & purification , Catheters, Indwelling , Cost-Benefit Analysis , Cross Infection/economics , Cross Infection/prevention & control , Drug Resistance, Bacterial , Equipment Design , Hospital Costs , Humans , Prospective Studies , Urinary Catheterization/adverse effects , Urinary Catheterization/economics , Urinary Tract Infections/drug therapy , Urinary Tract Infections/microbiology , Urinary Tract Infections/prevention & control
7.
Infect Control Hosp Epidemiol ; 24(2): 142-4, 2003 Feb.
Article in English | MEDLINE | ID: mdl-12602700

ABSTRACT

Monsel's solution is a common topically applied hemostatic agent used in minor dermatologic and gynecologic surgery. Clinically, because it is often stored for long periods and dispensed from a common source for multiple patients, Monsel's solution is a potential vector for transmission of infection. However, microbiologic inoculation studies and contamination surveys indicate that Monsel's solution has properties that prohibit microbial growth, making it an unlikely vector for nosocomial infection.


Subject(s)
Bacterial Infections/transmission , Colony Count, Microbial , Cross Infection/microbiology , Drug Contamination , Drug Storage/standards , Ferric Compounds/analysis , Hemostatics/analysis , Infection Control/standards , Sulfates/analysis , Bacterial Infections/etiology , Bacterial Infections/microbiology , Cross Infection/etiology , Drug Storage/methods , Ferric Compounds/adverse effects , Hemostatics/adverse effects , Humans , Risk , Sulfates/adverse effects , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...