Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Exp Neurol ; 347: 113901, 2022 01.
Article in English | MEDLINE | ID: mdl-34688600

ABSTRACT

BACKGROUND AND PURPOSE: Stroke therapy still lacks successful measures to improve post stroke recovery. Neurotrophin-3 (NT-3) is one promising candidate which has proven therapeutic benefit in motor recovery in acute experimental stroke. Post stroke, the immune system has opposing pathophysiological roles: pro-inflammatory cascades and immune cell infiltration into the brain exacerbate cell death while the peripheral immune response has only limited capabilities to fight infections during the acute and subacute phase. With time, anti-inflammatory mechanisms are supposed to support recovery of the ischemic damage within the brain parenchyma. However, interestingly, NT-3 can improve recovery in chronic neurological injury when combined with the pro-inflammatory stimulus lipopolysaccharide (LPS). AIM: We elucidated the impact of NT-3 on human monocyte and T cell activation as well as cytokine production ex vivo after stroke. In addition, we investigated the age-dependent availability of the high affinity NT-3 receptor TrkC upon LPS stimulation. METHODS: Peripheral blood mononuclear cells (PBMCs) were isolated from acute stroke patients and controls and incubated with different dosages of NT-3 (10 and 100 ng/mL) and with or without LPS or anti-CD3/CD28 for 48 h. Total TrkC expression and cell activation (CD25, CD69 and HLA-DR) were assessed by FACS staining. IFN-γ, TNF-α, IL-2, IL-4, IL-5, IL-6, IL-9, IL-10, IL-13, IL-17A, IL-17F, IL-21 and IL-22 were quantified by cytometric bead array. RESULTS: Most monocytes and only a small proportion of T cells expressed TrkC in blood from humans without stroke. Activation of cells from young humans (without strokes) using anti-CD3/CD28 or LPS partially reduced the proportion of monocytes expressing TrkC whilst they increased the proportion of T cells expressing TrkC. In contrast, activation of cells from elderly humans (without strokes) did not affect the proportion of monocytes expressing TrkC and only anti-CD3/CD28 led to an increase in the proportion of CD4+ T cells expressing TrkC. In blood from stroke patients or controls, NT-3 treatment reduced the percentage of monocytes and CD4+ and CD8+ T cells that were activated and reduced all cytokines investigated besides IL-21. CONCLUSIONS: NT-3 attenuated immune responses in cells from stroke patients and controls. The mechanism whereby human immune cells respond to NT-3 may be via TrkC receptors whose levels are regulated by stimulation. Further work is required to determine whether the induction of sensorimotor recovery in rodents by NT-3 after CNS injury is caused by this attenuation of the immune response.


Subject(s)
Cytokines/immunology , Immunity, Cellular/immunology , Monocytes/immunology , Neurotrophin 3/pharmacology , Stroke/immunology , T-Lymphocytes/immunology , Aged , Aged, 80 and over , Cells, Cultured , Cytokines/blood , Female , Humans , Immunity, Cellular/drug effects , Leukocytes, Mononuclear/drug effects , Leukocytes, Mononuclear/immunology , Leukocytes, Mononuclear/metabolism , Male , Middle Aged , Monocytes/drug effects , Monocytes/metabolism , Neurotrophin 3/therapeutic use , Single-Blind Method , Stroke/blood , Stroke/drug therapy , T-Lymphocytes/drug effects , T-Lymphocytes/metabolism , Young Adult
2.
Polymers (Basel) ; 13(21)2021 Oct 30.
Article in English | MEDLINE | ID: mdl-34771321

ABSTRACT

Adaptive composite propeller blades showing bend twist behaviour have received increasing interest from hydrodynamic and structural engineers. When exposed to periodic loading conditions, such propellers can be designed to have higher energy efficiency and emit less noise and vibration than conventional propellers. This work describes a method to produce an adaptive composite propeller blade and how a point load experiment can verify the predicted elastic response in the blade. A 600 mm-long hollow full-size blade was built and statically tested in the laboratory. Finite element modelling predicted a pitch angle change under operational load variable loads of 0.55°, a geometric change that notably compensates for the load cases. In the laboratory experiment, the blade was loaded at two points with increasing magnitude. The elastic response was measured with digital image correlation and strain gauges. Model predictions and experimental measurements showed the same deformation patterns, and the twist angle agreed within 0.01 degrees, demonstrating that such propellers can be successfully built and modelled by finite element analysis.

3.
J Mass Spectrom ; 50(2): 427-31, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25800025

ABSTRACT

In this study we demonstrate the potential of selective reagent ionisation-time of flight-mass spectrometry for the rapid and selective identification of a popular new psychoactive substance blend called 'synthacaine', a mixture that is supposed to imitate the sensory and intoxicating effects of cocaine. Reactions with H3O(+) result in protonated parent molecules which can be tentatively assigned to benzocaine and methiopropamine. However, by comparing the product ion branching ratios obtained at two reduced electric field values (90 and 170 Td) for two reagent ions (H3O(+) and NO(+)) to those of the pure chemicals, we show that identification is possible with a much higher level of confidence then when relying solely on the m/z of protonated parent molecules. A rapid and highly selective analytical identification of the constituents of a recreational drug is particularly crucial to medical personnel for the prompt medical treatment of overdoses, toxic effects or allergic reactions.


Subject(s)
Illicit Drugs/analysis , Mass Spectrometry/methods , Psychotropic Drugs/analysis , Substance Abuse Detection/methods , Benzocaine/analysis , Benzocaine/chemistry , Illicit Drugs/chemistry , Methamphetamine/analogs & derivatives , Methamphetamine/analysis , Methamphetamine/chemistry , Psychotropic Drugs/chemistry , Thiophenes/analysis , Thiophenes/chemistry
4.
Int J Mass Spectrom ; 360: 28-38, 2014 Mar 01.
Article in English | MEDLINE | ID: mdl-25844048

ABSTRACT

The rapid expansion in the number and use of new psychoactive substances presents a significant analytical challenge because highly sensitive instrumentation capable of detecting a broad range of chemical compounds in real-time with a low rate of false positives is required. A Selective Reagent Ionisation-Time of Flight-Mass Spectrometry (SRI-ToF-MS) instrument is capable of meeting all of these requirements. With its high mass resolution (up to m/Δm of 8000), the application of variations in reduced electric field strength (E/N) and use of different reagent ions, the ambiguity of a nominal (monoisotopic) m/z is reduced and hence the identification of chemicals in a complex chemical environment with a high level of confidence is enabled. In this study we report the use of a SRI-ToF-MS instrument to investigate the reactions of H3O+, O2+, NO+ and Kr+ with 10 readily available (at the time of purchase) new psychoactive substances, namely 4-fluoroamphetamine, methiopropamine, ethcathinone, 4-methylethcathinone, N-ethylbuphedrone, ethylphenidate, 5-MeO-DALT, dimethocaine, 5-(2-aminopropyl)benzofuran and nitracaine. In particular, the dependence of product ion branching ratios on the reduced electric field strength for all reagent ions was investigated and is reported here. The results reported represent a significant amount of new data which will be of use for the development of drug detection techniques suitable for real world scenarios.

5.
J Mass Spectrom ; 48(9): 1015-8, 2013 Sep.
Article in English | MEDLINE | ID: mdl-24078242

ABSTRACT

The isomers 4-methylethcathinone and N-ethylbuphedrone are substitutes for the recently banned drug mephedrone. We find that with conventional proton transfer reaction mass spectrometry (PTR-MS), it is not possible to distinguish between these two isomers, because essentially for both substances, only the protonated molecules are observed at a mass-to-charge ratio of 192 (C12 H18NO(+)). However, when utilising an advanced PTR-MS instrument that allows us to switch the reagent ions (selective reagent ionisation) from H3O(+) (which is commonly used in PTR-MS) to NO(+), O2(+) and Kr(+), characteristic product (fragment) ions are detected: C4H10N(+) (72 Da) for 4-methylethcathinone and C5 H12N(+) (86 Da) for N-ethylbuphedrone; thus, selective reagent ionisation MS proves to be a powerful tool for fast detection and identification of these compounds.


Subject(s)
Designer Drugs/chemistry , Mass Spectrometry/methods , Methamphetamine/analogs & derivatives , Psychotropic Drugs/chemistry , Indicators and Reagents , Ions/chemistry , Isomerism , Methamphetamine/chemistry
6.
Rapid Commun Mass Spectrom ; 27(2): 325-32, 2013 Jan 30.
Article in English | MEDLINE | ID: mdl-23239380

ABSTRACT

RATIONALE: Security and protection against terrorist attacks are major issues in modern society. One especially challenging task is the monitoring and protection of air conditioning and heating systems of buildings against terrorist attacks with toxic chemicals. As existing technologies have low selectivity, long response times or insufficient sensitivity, there is a need for a novel approach such as we present here. METHODS: We have analyzed various chemical warfare agents (CWAs) and/or toxic industrial compounds (TICs) and related compounds, namely phosgene, diphosgene, chloroacetone, chloroacetophenone, diisopropylaminoethanol, and triethyl phosphate, utilizing a high-resolution proton-transfer-reaction time-of-flight mass spectrometry (PTR-TOFMS) instrument with the objective of finding key product ions and their intensities, which will allow a low-resolution quadrupole mass spectrometry based PTR-MS system to be used with high confidence in the assignment of threat agents in the atmosphere. RESULTS: We obtained high accuracy PTR-TOFMS mass spectra of the six compounds under study at two different values for the reduced electric field in the drift tube (E/N). From these data we have compiled a table containing product ions, and isotopic and E/N ratios for highly selective threat compound detection with a compact and cost-effective quadrupole-based PTR-MS instrument. Furthermore, using chloroacetophenone (tear gas), we demonstrated that this instrument's response is highly linear in the concentration range of typical Acute Exposure Guideline Levels (AEGLs). CONCLUSIONS: On the basis of the presented results it is possible to develop a compact and cost-effective PTR-QMS instrument that monitors air supply systems and triggers an alarm as soon as the presence of a threat agent is detected. We hope that this real-time surveillance device will help to seriously improve safety and security in environments vulnerable to terrorist attacks with toxic chemicals.

7.
Rapid Commun Mass Spectrom ; 23(23): 3875-80, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19902419

ABSTRACT

This work demonstrates for the first time the potential of using recent developments in proton transfer reaction mass spectrometry for the rapid detection and identification of chemical warfare agents (CWAs) in real-time. A high-resolution (m/Deltam up to 8000) and high-sensitivity (approximately 50 cps/ppbv) proton transfer reaction time-of-flight mass spectrometer (PTR-TOF 8000 from Ionicon Analytik GmBH) has been successfully used to detect a number of CWA simulants at room temperature; namely dimethyl methylphosphonate, diethyl methylphosphonate, diisopropyl methylphosphonate, dipropylene glycol monomethyl ether and 2-chloroethyl ethyl sulfide. Importantly, we demonstrate in this paper the potential to identify CWAs with a high level of confidence in complex chemical environments, where multiple threat agents and interferents could also be present in trace amounts, thereby reducing the risk of false positives. Instantaneous detection and identification of trace quantities of chemical threats using proton transfer reaction mass spectrometry could form the basis for a timely warning system capability with greater precision and accuracy than is currently provided by existing analytical technologies.

SELECTION OF CITATIONS
SEARCH DETAIL
...