Publication year range
1.
Medicina (Kaunas) ; 60(1)2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38276056

ABSTRACT

Background: During endotracheal intubation, there is a 10% incidence of difficult laryngoscopy, which may result in serious complications. It is important to obtain as much information about the visibility of laryngeal structures before the patient is anaesthetised. Performing awake (video-) laryngoscopy on a patient is uncomfortable and can trigger gagging and coughing reflexes, making visualisation nearly impossible. The objective of this study is to evaluate the effectiveness of a soft mist spray device for airway anaesthesia during awake (video-) laryngoscopy. Methods: Twenty healthy volunteers inhaled through the Trachospray device, which was placed in their mouths. Two 2 mL syringes containing lidocaine at 4% were sprayed into the airway during inspiration. After several minutes, the subjects were asked to perform a videolaryngoscopy on themselves until the glottic structures and the vocal cords were visible. Upon completion of the procedure, all participants were asked to fill out a feedback form. Results: The duration of the videolaryngoscopy to visualisation of the vocal cords averaged 17 ± 13 s. After analysing the data, three distinct groups emerged as follows: Group 1 (70% of participants) showed no response, allowing for easy insertion of the videolaryngoscope. Group 2 (25% of participants) exhibited a light response but still permitted easy insertion and visualisation. One patient demonstrated a clear response with noticeable laryngeal contraction, requiring slightly more effort and discomfort for insertion. In 80% of the participants, the laryngeal structures were visualised according to Cormack-Lehane grade 1. All participants reported a high level of comfort, with an average rating of NRS 8. The anaesthesiologist assessed the level of anaesthesia as good to very good. No adverse events were observed. Conclusions: The Trachospray provided good, reliable, comfortable, and safe topical anaesthesia for awake videolaryngoscopy. This enables a direct visual assessment of the airway and may assist in making decisions regarding airway management for tracheal intubation.


Subject(s)
Laryngoscopy , Wakefulness , Humans , Laryngoscopy/adverse effects , Laryngoscopy/methods , Intubation, Intratracheal/methods , Anesthesia, Local , Healthy Volunteers
2.
Med Devices (Auckl) ; 14: 9-14, 2021.
Article in English | MEDLINE | ID: mdl-33519246

ABSTRACT

BACKGROUND: Obtaining complete topical anaesthesia of the airway remains a clinical challenge. Particle size is one of the most important variables for the dose deposited and the distribution of aerosols in the airways. The mass median aerodynamic diameter of the particles should be in the range of 5-20 µm. We developed the "Trachospray" as a soft mist spray device for local anaesthetics. This in-vitro comparative test was designed to compare the performance of the new Trachospray device with two existing medical devices. The performance was determined by comparing the spray deposition patterns in the mouth, throat, trachea and lungs. METHODS: The human airway was simulated with an artificial idealized mouth and throat model, connected to a Next Generation Impactor. Four measurements were taken for each device (Trachospray, jet nebulizer and a spray pump) with 5.85% NaCl. A fifth measurement was carried out with 0.5% fluorescein solution for a visual inspection of the deposition patterns. The mass median aerodynamic diameter and geometric standard deviation of the droplets were measured. RESULTS: The Trachospray produced an even coverage in the mouth, hypopharynx and vocal cords, with only a small lung fraction. The jet nebulizer produced a much thinner layer coverage of the tongue and surface around the vocal chords with a high lung deposition. The spray pump produced big droplets which deposited mainly at the hypopharynx. CONCLUSION: The Trachospray device deposits local anaesthetics in the targeted areas for topical anaesthesia of the airway and has promising characteristics for providing effective airway anaesthesia.

SELECTION OF CITATIONS
SEARCH DETAIL
...