Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Rheumatol ; 3(2): 65-72, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27708974

ABSTRACT

OBJECTIVE: To evaluate the clinical utility of a novel radiotracer, 99mTc-glucosamine, in assessing disease activity of both rheumatoid arthritis (RA) and ankylosing spondylitis (AS). Material and Methods: Twenty-five patients with RA (nine males and 16 females) and 12 patients with AS (all male) at various stages of disease were recruited for the study. A clinical history and examination was performed, followed by the measurement of hematological, biochemical, and autoimmune serological parameters to assess disease activity. 99mTc-glucosamine was intravenously administered and scans were compared with other imaging modalities, including plain X-ray, magnetic resonance imaging (MRI), and bone scans. RESULTS: In patients with AS, 99mTc-glucosamine scans were more capable of identifying active disease and differentiating between inflammatory and non-inflammatory causes. In patients with RA, 99mTc-glucosamine accumulated at all known sites of disease involvement. Uptake was most pronounced in patients with active untreated disease. The relative tracer activity in the involved joints increased with time compared with that in the adjoining soft tissue, liver, and cardiac blood pool. Using Spearman's correlation coefficient, there was a positive correlation among glucosamine scan scores, C-reactive protein (p=0.048), and clinical assessment (p=0.003), which was not noted with bone scans. CONCLUSION: The radiotracer was well tolerated by all patients, with no adverse reactions. 99mTc-glucosamine imaging could detect spinal inflammation in AS. With respect to RA, 99mTc-glucosamine was a viable alternative to 99mTc-labeled methylene diphosphonate nuclear bone scans for imaging inflamed joints and had the added advantage of demonstrating a significant clinical correlation between disease activity and scan findings.

2.
J Am Med Inform Assoc ; 18(3): 335-40, 2011 May 01.
Article in English | MEDLINE | ID: mdl-21385821

ABSTRACT

BACKGROUND: Computerized provider order entry (CPOE) systems have been strongly promoted as a means to improve the quality and efficiency of healthcare. METHODS: This systematic review aimed to assess the evidence of the impact of CPOE on medical-imaging services and patient outcomes. RESULTS: Fourteen studies met the inclusion criteria, most of which (10/14) used a pre-/postintervention comparison design. Eight studies demonstrated benefits, such as decreased test utilization, associated with decision-support systems promoting adherence to test ordering guidelines. Three studies evaluating medical-imaging ordering and reporting times showed statistically significant decreases in turnaround times. CONCLUSIONS: The findings reveal the potential for CPOE to contribute to significant efficiency and effectiveness gains in imaging services. The diversity and scope of the research evidence can be strengthened through increased attention to the circumstances and mechanisms that contribute to the success (or otherwise) of CPOE and its contribution to the enhancement of patient care delivery.


Subject(s)
Diagnostic Imaging , Guideline Adherence , Medical Order Entry Systems , Outcome Assessment, Health Care , Decision Support Systems, Clinical , Diagnostic Imaging/statistics & numerical data , Humans , Unnecessary Procedures
SELECTION OF CITATIONS
SEARCH DETAIL
...