1.
Hypertension ; 74(3): 546-554, 2019 09.
Article in English | MEDLINE | ID: mdl-31303108

ABSTRACT

Radiofrequency renal denervation is under investigation for treatment of hypertension with variable success. We developed preclinical models to examine the dependence of ablation biomarkers on renal denervation treatment parameters and anatomic variables. One hundred twenty-nine porcine renal arteries were denervated with an irrigated radiofrequency catheter with multiple helically arrayed electrodes. Nerve effects and ablation geometries at 7 days were characterized histomorphometrically and correlated with associated renal norepinephrine levels. Norepinephrine exhibited a threshold dependence on the percentage of affected nerves across the range of treatment durations (30-60 s) and power set points (6-20 W). For 15 W/30 s treatments, norepinephrine reduction and percentage of affected nerves tracked with number of electrode treatments, confirming additive effects of helically staggered ablations. Threshold effects were only attained when ≥4 electrodes were powered. Histomorphometry and computational modeling both illustrated that radiofrequency treatments directed at large neighboring veins resulted in subaverage ablation areas and, therefore, contributed suboptimally to efficacy. Account for measured nerve distribution patterns and the annular geometry of the artery revealed that, regardless of treatment variables, total ablation area and circumferential coverage were the prime determinants of renal denervation efficacy, with increased efficacy at smaller diameters.


Subject(s)
Catheter Ablation/methods , Hypertension/surgery , Kidney/innervation , Norepinephrine/blood , Renal Artery/surgery , Sympathectomy/methods , Animals , Biopsy, Needle , Disease Models, Animal , Electrodes , Female , Humans , Hypertension/physiopathology , Immunohistochemistry , Male , Random Allocation , Reference Values , Swine , Treatment Outcome
2.
PLoS One ; 13(1): e0192004, 2018.
Article in English | MEDLINE | ID: mdl-29377941

ABSTRACT

Sex-related differences have been noted in cardiovascular anatomy, pathophysiology, and treatment responses, yet we continued to drive evaluation of vascular device development in animal models without consideration of animal sex. We aimed to understand sex-related differences in the vascular responses to stent implantation by analyzing the pooled data of endovascular interventions in 164 Yucatan mini-swine (87 female, 77 male). Bare metal stents (BMS) or drug-eluting stents (DES) were implanted in 212 coronary arteries (63 single BMS implantation, 68 single DES implantation, 33 overlapped BMS implantation, and 48 overlapped DES implantation). Histomorphological parameters were evaluated from vascular specimens at 3-365 days after stent implantation and evaluated values were compared between female and male groups. While neointima formation at all times after implantation was invariant to sex, statistically significant differences between female and male groups were observed in injury, inflammation, adventitial fibrosis, and neointimal fibrin deposition. These differences were observed independently, i.e., for different procedure types and at different follow-up timings. Only subtle temporal sex-related differences were observed in extent and timing of resolution of inflammation and fibrin clearance. These subtle sex-related differences may be increasingly important as interventional devices meld novel materials that erode and innovations in drug delivery. Erodible materials may act differently if inflammation has a different temporal sequence with sex, and drug distribution after balloon or stent delivery might be different if the fibrin clearance speaks to different modes of pharmacokinetics in male and female swine.


Subject(s)
Models, Animal , Sex Factors , Stents , Animals , Female , Male , Swine , Swine, Miniature , Tunica Intima
3.
J Orthop Res ; 35(10): 2181-2190, 2017 10.
Article in English | MEDLINE | ID: mdl-28135014

ABSTRACT

Bone healing, biocompatibility, and safety employing the IlluminOss System (IS), comprised of an inflatable balloon filled with photopolymerizable liquid monomer, was evaluated in New Zealand white rabbits. Successful bone healing and callus remodeling over 6 months was demonstrated radiologically and histologically with IS implants in fenestrated femoral cortices. Biocompatibility was demonstrated with IS implants in brushed, flushed femoral intramedullary spaces, eliciting no adverse, local, or systemic responses and with similar biocompatibility to K-wires in contralateral femurs up to 1 year post-implant. Lastly simulated clinical failures demonstrated the safety of IS implants up to 1 year in the presence of liquid or polymerized polymer within the intramedullary space. Polymerized material displayed cortical bone and vasculature effects comparable to mechanical disruption of the endosteum. In the clinically unlikely scenario with no remediation or polymerization, a high dose monomer injection resulted in marked necrosis of cortical bone, as well as associated vasculature, endosteum, and bone marrow. Overall, when polymerized and hardened within bone intramedullary spaces, this light curable monomer system may provide a safe and effective method for fracture stabilization. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2181-2190, 2017.


Subject(s)
Femoral Fractures/therapy , Fracture Fixation, Internal/instrumentation , Animals , Female , Fracture Healing , Materials Testing , Minimally Invasive Surgical Procedures , Rabbits
4.
EuroIntervention ; 12(17): 2148-2156, 2017 Apr 20.
Article in English | MEDLINE | ID: mdl-27993749

ABSTRACT

AIMS: Simple surface modifications can enhance coronary stent performance. Ultra-hydrophilic surface (UHS) treatment of contemporary bare metal stents (BMS) was assessed in vivo to verify whether such stents can provide long-term efficacy comparable to second-generation drug-eluting stents (DES) while promoting healing comparably to BMS. METHODS AND RESULTS: UHS-treated BMS, untreated BMS and corresponding DES were tested for three commercial platforms. A thirty-day and a 90-day porcine coronary model were used to characterise late tissue response. Three-day porcine coronary and seven-day rabbit iliac models were used for early healing assessment. In porcine coronary arteries, hydrophilic treatment reduced intimal hyperplasia relative to the BMS and corresponding DES platforms (1.5-fold to threefold reduction in 30-day angiographic and histological stenosis; p<0.04). Endothelialisation was similar on UHS-treated BMS and untreated BMS, both in swine and rabbit models, and lower on DES. Elevation in thrombotic indices was infrequent (never observed with UHS, rare with BMS, most often with DES), but, when present, correlated with reduced endothelialisation (p<0.01). CONCLUSIONS: Ultra-hydrophilic surface treatment of contemporary stents conferred good healing while moderating neointimal and thrombotic responses. Such surfaces may offer safe alternatives to DES, particularly when rapid healing and short dual antiplatelet therapy (DAPT) are crucial.


Subject(s)
Hydrophobic and Hydrophilic Interactions , Percutaneous Coronary Intervention/instrumentation , Stents , Animals , Neointima/prevention & control , Rabbits , Swine , Thrombosis/prevention & control
5.
EuroIntervention ; 11(12): 1435-41, 2016 Mar.
Article in English | MEDLINE | ID: mdl-25735934

ABSTRACT

AIMS: We sought to evaluate the incidence of embolic material in porcine brains following vascular interventions using hydrophilic-coated sheaths. METHODS AND RESULTS: A new self-expanding stent and delivery system (SDS) was deployed through a hydrophilic-coated (Flexor Ansel; Cook Medical, Bloomington, IN, USA) guiding sheath into the iliac and/or carotid arteries of 23 anaesthetised Yucatan mini swine. The animals were euthanised at three, 30, 90 and 180 days and their brains were removed for histological analysis. In an additional single control animal, the guiding sheath was advanced but no SDS was deployed. Advancement of the coated guiding sheath with or without the SDS was associated with frequent foreign material in the arterioles of the brain. The embolic material was amorphous, non-refractile, non-crystalline, non-birefringent and typically lightly basophilic with a slightly stippled appearance on haematoxylin and eosin (H&E) stain. Material was observed at all time points involving 54% of all study animals (i.e., test and control) and in vitro after incubation in 0.9% saline. CONCLUSIONS: The hydrophilic coating on a clinically used guiding sheath readily avulses and embolises to the brain during deployment in a porcine model. Further documentation of this effect and monitoring in clinical scenarios are warranted.


Subject(s)
Carotid Arteries , Catheterization, Peripheral/instrumentation , Coated Materials, Biocompatible , Endovascular Procedures/instrumentation , Equipment Failure , Foreign-Body Migration/etiology , Iliac Artery , Intracranial Embolism/etiology , Vascular Access Devices , Animals , Brain/pathology , Catheterization, Peripheral/adverse effects , Endovascular Procedures/adverse effects , Equipment Design , Foreign-Body Migration/pathology , Hydrophobic and Hydrophilic Interactions , Intracranial Embolism/pathology , Stents , Swine , Swine, Miniature , Time Factors
6.
J Biomed Mater Res B Appl Biomater ; 104(2): 291-9, 2016 Feb.
Article in English | MEDLINE | ID: mdl-25772144

ABSTRACT

Percutaneous intramedullary fixation may provide an ideal method for stabilization of bone fractures, while avoiding the need for large tissue dissections. Tibiae in 18 sheep were treated with an intramedullary photodynamic bone stabilization system (PBSS) that comprised a polyethylene terephthalate (Dacron) balloon filled with a monomer, cured with visible light in situ, and then harvested at 30, 90, or 180 days. In additional 40 sheep, a midshaft tibial osteotomy was performed and stabilized with external fixators or external fixators combined with the PBSS and evaluated at 8, 12, and 26 weeks. Healing and biocompatibility were evaluated by radiographic analysis, micro-computed tomography, and histopathology. In nonfractured sheep tibiae, PBSS implants conformably filled the medullary canal, while active cortical bone remodeling and apposition of new periosteal and/or endosteal bone was observed with no significant macroscopic or microscopic observations. Fractured sheep tibiae exhibited increased bone formation inside the osteotomy gap, with no significant difference when fixation was augmented by PBSS implants. Periosteal callus size gradually decreased over time and was similar in both treatment groups. No inhibition of endosteal bone remodeling or vascularization was observed with PBSS implants. Intramedullary application of a light-curable PBSS is a biocompatible, feasible method for fracture fixation.


Subject(s)
Bone Substitutes , External Fixators , Fracture Healing , Light , Tibial Fractures/therapy , Animals , Bone Substitutes/adverse effects , Bone Substitutes/chemistry , Bone Substitutes/pharmacology , Drug Evaluation, Preclinical , Materials Testing/methods , Sheep
7.
Sci Transl Med ; 7(285): 285ra65, 2015 Apr 29.
Article in English | MEDLINE | ID: mdl-25925684

ABSTRACT

Renal denervation (RDN) is a treatment option for patients with hypertension resistant to conventional therapy. Clinical trials have demonstrated variable benefit. To understand the determinants of successful clinical response to this treatment, we integrated porcine and computational models of intravascular radiofrequency RDN. Controlled single-electrode denervation resulted in ablation zone geometries that varied in arc, area, and depth, depending on the composition of the adjacent tissue substructure. Computational simulations predicted that delivered power density was influenced by tissue substructure, and peaked at the conductivity discontinuities between soft fatty adventitia and water-rich tissues (media, lymph nodes, etc.), not at the electrode-tissue interface. Electrode irrigation protected arterial wall tissue adjacent to the electrode by clearing heat that diffuses from within the tissue, without altering periarterial ablation. Seven days after multielectrode treatments, renal norepinephrine and blood pressure were reduced. Blood pressure reductions were correlated with the size-weighted number of degenerative nerves, implying that the effectiveness of the treatment in decreasing hypertension depends on the extent of nerve injury and ablation, which in turn are determined by the tissue microanatomy at the electrode site. These results may explain the variable patient response to RDN and suggest a path to more robust outcomes.


Subject(s)
Arteries/anatomy & histology , Denervation , Hypertension/therapy , Kidney/innervation , Animals , Swine
8.
J Am Coll Cardiol ; 64(11): 1079-87, 2014 Sep 16.
Article in English | MEDLINE | ID: mdl-25212640

ABSTRACT

BACKGROUND: Renal denervation is a new interventional approach to treat hypertension with variable results. OBJECTIVES: The purpose of this study was to correlate response to endovascular radiofrequency ablation of renal arteries with nerve and ganglia distributions. We examined how renal neural network anatomy affected treatment efficacy. METHODS: A multielectrode radiofrequency catheter (15 W/60 s) treated 8 renal arteries (group 1). Arteries and kidneys were harvested 7 days post-treatment. Renal norepinephrine (NEPI) levels were correlated with ablation zone geometries and neural injury. Nerve and ganglion distributions and sizes were quantified at discrete distances from the aorta and were compared with 16 control arteries (group 2). RESULTS: Nerve and ganglia distributions varied with distance from the aorta (p < 0.001). A total of 75% of nerves fell within a circumferential area of 9.3, 6.3, and 3.4 mm of the lumen and 0.3, 3.0, and 6.0 mm from the aorta. Efficacy (NEPI 37 ng/g) was observed in only 1 of 8 treated arteries where ablation involved all 4 quadrants, reached a depth of 9.1 mm, and affected 50% of nerves. In 7 treated arteries, NEPI levels remained at baseline values (620 to 991 ng/g), ≤20% of the nerves were affected, and the ablation areas were smaller (16.2 ± 10.9 mm(2)) and present in only 1 to 2 quadrants at maximal depths of 3.8 ± 2.7 mm. CONCLUSIONS: Renal denervation procedures that do not account for asymmetries in renal periarterial nerve and ganglia distribution may miss targets and fall below the critical threshold for effect. This phenomenon is most acute in the ostium but holds throughout the renal artery, which requires further definition.


Subject(s)
Catheter Ablation , Endovascular Procedures , Renal Artery/innervation , Renal Artery/surgery , Sympathectomy , Animals , Male , Swine , Treatment Outcome
9.
J Hypertens ; 32(8): 1678-91; discussion 1691-2, 2014 Aug.
Article in English | MEDLINE | ID: mdl-24875181

ABSTRACT

OBJECTIVE: To evaluate the safety and effectiveness of different bipolar radiofrequency system algorithms in interrupting the renal sympathetic nerves and reducing renal norepinephrine in a healthy porcine model. METHODS: A porcine model (N = 46) was used to investigate renal norepinephrine levels and changes to renal artery tissues and nerves following percutaneous renal denervation with radiofrequency bipolar electrodes mounted on a balloon catheter. Parameters of the radiofrequency system (i.e. electrode length and energy delivery algorithm), and the effects of single and longitudinal treatments along the artery were studied with a 7-day model in which swine received unilateral radiofrequency treatments. Additional sets of animals were used to examine norepinephrine and histological changes 28 days following bilateral percutaneous radiofrequency treatment or surgical denervation; untreated swine were used for comparison of renal norepinephrine levels. RESULTS: Seven days postprocedure, norepinephrine concentrations decreased proportionally to electrode length, with 81, 60 and 38% reductions (vs. contralateral control) using 16, 4 and 2-mm electrodes, respectively. Applying a temperature-control algorithm with the 4-mm electrodes increased efficacy, with a mean 89.5% norepinephrine reduction following a 30-s treatment at 68°C. Applying this treatment along the entire artery length affected more nerves vs. a single treatment, resulting in superior norepinephrine reduction 28 days following bilateral treatment. CONCLUSION: Percutaneous renal artery application of bipolar radiofrequency energy demonstrated safety and resulted in a significant renal norepinephrine content reduction and renal nerve injury compared with untreated controls in porcine models.


Subject(s)
Catheter Ablation/methods , Norepinephrine/analysis , Renal Artery/innervation , Sympathectomy/methods , Animals , Blood Pressure , Creatinine/blood , Heart Rate , Kidney/chemistry , Kidney/innervation , Models, Animal , Renal Artery/pathology , Swine , Tyrosine 3-Monooxygenase/analysis
10.
J Control Release ; 162(3): 561-7, 2012 Sep 28.
Article in English | MEDLINE | ID: mdl-22800575

ABSTRACT

Current drug eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug delivery. A novel, absorbable-coating sirolimus-eluting stent (AC-SES) was evaluated for its capacity to deliver drug more evenly within the intimal area rather than concentrating drug around the stent struts and for its ability to match coating erosion with drug release. The coating consisted of absorbable poly-lactide-co-glycolic acid (PLGA) and crystalline sirolimus deposited by a dry-powder electrostatic process. The AC-SES demonstrated enhanced drug stability under simulated use conditions and consistent drug delivery balanced with coating erosion in a porcine coronary implant model. The initial drug burst was eliminated and drug release was sustained after implantation. The coating was absorbed within 90 days. Following implantation into porcine coronary arteries the AC-SES coating is distributed in the surrounding intimal tissue over the course of several weeks. Computational modeling of drug delivery characteristics demonstrates how distributed coating optimizes the load of drug immediately around each stent strut and extends drug delivery between stent struts. The result was a highly efficient arterial uptake of drug with superior performance to a clinical bare metal stent (BMS). Neointimal thickness (0.17±0.07 mm vs. 0.28±0.11 mm) and area percent stenosis (22±9% vs. 35±12%) were significantly reduced (p<0.05) by the AC-SES compared to the BMS 30 days after stent implantation in an overlap configuration in porcine coronary arteries. Inflammation was significantly reduced in the AC-SES compared to the BMS at both 30 and 90 days after implantation. Biocompatible, rapidly absorbable stent coatings enable the matching of drug release with coating erosion and provide for the controlled migration of coating material into tissue to reduce vicissitudes in drug tissue levels, optimizing efficacy and reducing potential toxicity.


Subject(s)
Anti-Inflammatory Agents/administration & dosage , Drug Delivery Systems , Drug-Eluting Stents , Neointima/drug therapy , Sirolimus/administration & dosage , Animals , Anti-Inflammatory Agents/chemistry , Anti-Inflammatory Agents/pharmacokinetics , Constriction, Pathologic/drug therapy , Constriction, Pathologic/pathology , Coronary Vessels/drug effects , Coronary Vessels/metabolism , Coronary Vessels/pathology , Crystallization , Lactic Acid/chemistry , Models, Biological , Neointima/pathology , Polyglycolic Acid/chemistry , Polylactic Acid-Polyglycolic Acid Copolymer , Polymers/chemistry , Sirolimus/chemistry , Sirolimus/pharmacokinetics , Swine , Tunica Media/drug effects , Tunica Media/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...