1.
Adv Lab Med ; 5(2): 115-130, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38939201

ABSTRACT

Liver fibrosis is the result of chronic liver injury of different etiologies produced by an imbalance between the synthesis and degeneration of the extracellular matrix and dysregulation of physiological mechanisms. Liver has a high regenerative capacity in the early stage of chronic diseases so a prompt liver fibrosis detection is important. Consequently, an easy and economic tool that could identify patients with liver fibrosis at the initial stages is needed. To achieve this, many non-invasive serum direct, such as hyaluronic acid or metalloproteases, and indirect biomarkers have been proposed to evaluate liver fibrosis. Also, there have been developed formulas that combine these biomarkers, some of them also introduce clinical and/or demographic parameters, like FIB-4, non-alcoholic fatty liver disease fibrosis score (NFS), enhance liver fibrosis (ELF) or Hepamet fibrosis score (HFS). In this manuscript we critically reviewed different serum biomarkers and formulas for their utility in the diagnosis and progression of liver fibrosis.

3.
Clin Chim Acta ; 557: 117897, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38570026

ABSTRACT

BACKGROUND AND AIMS: Small-dense-low-density-lipoprotein cholesterol (sdLDL-C) is proatherogenic and not commonly measured. The aims were to evaluate capillary blood and its stability for sdLDL-C measurement and measure sdLDL-C in patients with metabolic syndrome (MS). METHODS: 182 patients were studied (49 with MS). sdLDL-C was measured by electrophoresis (LipoPrint®), direct measurement (Roche Diagnostics) and Sampson equation. Intima-media thickness (IMT) and presence of atheroma was evaluated. sdLDL-C was compared in paired venous and capillary blood according to CLSI-EP09c (n = 40). sdLDL-C stability was studied after 24 h at room temperature (RT). RESULTS: sdLDL-C in capillary blood and venous blood showed agreement with the direct measurement (bias: 4.17 mg/dL, LOA 95 %:-5.66; 13.99) and estimation (bias:8.12 mg/dL, LOA 95 %:-8.59; 24.82). sdLDL-C is stable in capillary blood for 24 h at RT. The electrophoretic method yielded lower (p < 0.05) sdLDL-C than the equation or direct measurement. Patients with MS had (p < 0.05) higher sdLDL-C (%) than patients without MS. Patients with atheroma plaques had higher sdLDL-C (p < 0.05). Estimated sdLDL-C correlated with IMT (r = 0.259, p < 0.001). CONCLUSIONS: Capillary blood is an alternative to venous blood for sdLDL-C measurement and is stable for 24 h after collection. Estimated and directly measured sdLDL-C associate with the MS being accessible tools for cardiovascular risk assessment.


Subject(s)
Metabolic Syndrome , Plaque, Atherosclerotic , Humans , Carotid Intima-Media Thickness , Plaque, Atherosclerotic/diagnostic imaging , Cholesterol, LDL , Risk Assessment , Risk Factors
4.
Clin Chim Acta ; 548: 117471, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37419300

ABSTRACT

INTRODUCTION: Multiple sclerosis (MS) is the most frequent demyelinating disease of the central nervous system. Although there is currently no definite cure for MS, new therapies have recently been developed based on a continuous search for new biomarkers. DEVELOPMENT: MS diagnosis relies on the integration of clinical, imaging and laboratory findings as there is still no singlepathognomonicclinical feature or diagnostic laboratory biomarker. The most commonly laboratory test used is the presence of immunoglobulin G oligoclonal bands (OCB) in cerebrospinal fluid of MS patients. This test is now included in the 2017 McDonald criteria as a biomarker of dissemination in time. Nevertheless, there are other biomarkers currently in use such as kappa free light chain, which has shown higher sensitivity and specificity for MS diagnosis than OCB. In addition, other potential laboratory tests involved in neuronal damage, demyelination and/or inflammation could be used for detecting MS. CONCLUSIONS: CSF and serum biomarkers have been reviewed for their use in MS diagnosis and prognosis to stablish an accurate and prompt MS diagnosis, crucial to implement an adequate treatment and to optimize clinical outcomes over time.


Subject(s)
Multiple Sclerosis , Humans , Multiple Sclerosis/cerebrospinal fluid , Biomarkers , Oligoclonal Bands/cerebrospinal fluid , Immunoglobulin Light Chains , Immunoglobulin kappa-Chains/cerebrospinal fluid
5.
Diagnosis (Berl) ; 10(3): 281-297, 2023 08 01.
Article in English | MEDLINE | ID: mdl-36877154

ABSTRACT

OBJECTIVES: Remote self-collected capillary blood samples have been proposed as alternative to venous blood samples as an aid in telemedicine. The aim of this work is to compare the preanalytical and analytical performance of these two types of samples and to study the stability of common measurands in capillary blood. METHODS: Capillary and venous blood samples were collected in parallel from 296 patients in serum tubes to analyze 22 common biochemistry magnitudes after centrifugation and in EDTA tubes to analyze 15 hematologic magnitudes. Quality of the preanalytical process was assessed applying the model of quality indicator. 24 h stability at room temperature was studied by obtaining paired capillary samples. A questionnaire of assessment was conducted. RESULTS: Mean hemolysis index was higher in capillary samples compared to venous blood samples (p<0.001). Regression analysis and difference analysis showed no bias for all studied biochemistry parameters and hematologic parameters, except mean corpuscular volume (MCV), between capillary and venous blood samples. Regarding sample stability, percentage deviation was higher than the corresponding minimum analytical performance specification for ferritin, vitamin D, hematocrit, MCV, mean corpuscular hemoglobin concentration, platelets distribution wide, mean platelet volume and basophils. Finger pricking was perceived as less painful (p<0.05) than venipuncture in participants who undergo more than one blood test per year. CONCLUSIONS: Capillary blood can be used as an alternative to venous blood for the studied parameters in automated common clinical analyzers. Cautious should be taken if samples are not analyzed within 24 h from the collection.


Subject(s)
Clinical Laboratory Services , Laboratories, Clinical , Humans , Blood Coagulation Tests , Phlebotomy , Biomarkers
6.
Adv Lab Med ; 3(4): 317-320, 2022 Dec.
Article in English, Spanish | MEDLINE | ID: mdl-37363434
7.
Biomolecules ; 10(12)2020 12 19.
Article in English | MEDLINE | ID: mdl-33352636

ABSTRACT

Hypoandrogenemia, a frequent finding in men with obesity, is defined by low concentrations of serum testosterone. Although immunoassay (IA) is the most used method for the determination of this steroid in clinical practice, liquid chromatography-mass spectrometry (LC-MS/MS) is considered a more reliable method. In this study, we aimed to compare IA versus LC-MS/MS measurement for the diagnosis of hypoandrogenemia in a cohort of 273 nondiabetic young obese men. Mean total testosterone (TT) levels were 3.20 ± 1.24 ng/mL for IA and 3.78 ± 1.4 ng/mL for LC-MS/MS. 53.7% and 26.3% of patients were classified as presenting hypoandrogenemia with IA and LC-MS/MS, respectively. Considering LC-MS/MS as the reference method, sensitivity and specificity of IA were 91.4% (95% CI 82.3-96.8) and 61.1% (95% CI 54.0-67.8), respectively. IA presented an AUC of 0.879 (95% CI 0.83-0.928). Multivariate regression analysis indicated that sex hormone-binding globulin (SHBG) concentrations (p = 0.002) and insulin resistance (p = 0.008) were factors associated with discrepant IA values. In conclusion, the determination of TT by IA in nondiabetic young men with obesity yields lower concentrations of TT than LC-MS/MS, resulting in an equivocal increased diagnosis of hypoandrogenemia, which could lead to inaccurate diagnosis and unnecessary treatment.


Subject(s)
Chromatography, Liquid/methods , Immunoassay/methods , Obesity/blood , Tandem Mass Spectrometry/methods , Testosterone/blood , Adult , Chromatography/methods , Humans , Limit of Detection , Male , Middle Aged , Regression Analysis , Reproducibility of Results , Sensitivity and Specificity