ABSTRACT
Biofilm on dental unit waterlines can spread microbial contamination in the water. The aim of this study was to investigate microbial contamination of water from supplies and dental units before and after the implementation of a protocol for microbial quality improvement and maintenance of dental unit water. The microbial load was evaluated in water from 27 taps and dental units (reservoirs, air-water syringes and highspeed outputs without handpieces) using the PetrifilmT system (total aerobic bacteria and fungi) and conventional culture media (enterobacteria and Legionella spp.). The bacterial load in water samples from taps and reservoirs was within the parameter established by Brazilian legislation (<500CFU/mL); but the bacterial load in samples from air-water syringes and high-speed outputs without handpieces was not. The implementation of the protocol for the maintenance of microbial quality in dental unit water reduced bacterial load in highspeed outputs without handpieces (p=0.004). Enterobacteria and Legionella spp. were not isolated from any of the water samples from taps and dental units.
Biofilme nas linhas d\'água de equipos odontológicos pode propagar contaminando microbiana na água. O objetivo deste estudo foi investigar a contaminando microbiana da água de abastecimentos e equipos odontológicos antes e após a implementando de um protocolo para melhoria e manutenndo da qualidade microbiològica da água de equipos dontológicos. Avaliou-se a carga microbiana da água de 27 torneiras e equipos (reservatórios, seringas tríplice e alta rotando sem as penas de mdo) de uma clínica odontológica por meio do sistema PetrifilmT (bacterias aeróbias totais e fungos) e meios de cultura convencionais (enterobactérias e Legionella spp.). A carga bacteriana em amostras de água das torneiras e reservatórios estava dentro do paràmetro estabelecido pela legislando brasileira (<500 UFC/mL), mas a carga bacteriana das seringas tríplices e das saídas dos alta rotando sem as penas de mdo ndo estava. A implementando do protocolo para manutenndo da qualidade da água dos equipos reduziu a carga bacteriana nas saídas dos alta rotando sem as penas de mdo (p=0,004). Enterobactérias e Legionella spp. ndo foram isoladas de qualquer das amostras de água das torneiras e dos equipos odontológicos.
Subject(s)
Bacterial Load , Decontamination/methods , Dental Equipment/microbiology , Equipment Contamination/prevention & control , Water Microbiology , Biofilms , Colony Count, Microbial , Fungi/isolation & purificationABSTRACT
Biofilm on dental unit waterlines can spread microbial contamination in the water. The aim of this study was to investigate microbial contamination of water from supplies and dental units before and after the implementation of a protocol for microbial quality improvement and maintenance of dental unit water. The microbial load was evaluated in water from 27 taps and dental units (reservoirs, airwater syringes and highspeed outputs without handpieces) using the Petrifilm™ system (total aerobic bacteria and fungi) and conventional culture media (enterobacteria and Legionella spp.). The bacterial load in water samples from taps and reservoirs was within the parameter established by Brazilian legislation (<500CFU/mL); but the bacterial load in samples from airwater syringes and highspeed outputs without handpieces was not. The imple mentation of the protocol for the maintenance of microbial quality in dental unit water reduced bacterial load in highspeed outputs without handpieces (p=0.004). Enterobacteria and Legionella spp. were not isolated from any of the water samples from taps and dental units (AU)
Biofilme nas linhas d'água de equipos odontológicos pode propagar contaminação microbiana na água. O objetivo deste estudo foi investigar a contaminação microbiana da água de abastecimentos e equipos odontológicos antes e após a implemen tação de um protocolo para melhoria e manutenção da qualidade microbiológica da água de equipos odontológicos. Avaliouse a carga microbiana da água de 27 torneiras e equipos (reservatórios, seringas tríplice e alta rotação sem as peças de mão) de uma clínica odontológica por meio do sistema Petrifilm™ (bactérias aeróbias totais e fungos) e meios de cultura convencionais (enterobactérias e Legionella spp.). A carga bacteriana em amostras de água das torneiras e reservatórios estava dentro do parâmetro estabelecido pela legislação brasileira (<500 UFC/mL), mas a carga bacte riana das seringas tríplices e das saídas dos alta rotação sem as peças de mão não estava. A implementação do protocolo para manutenção da qualidade da água dos equipos reduziu a carga bacteriana nas saídas dos alta rotação sem as peças de mão (p=0,004). Enterobactérias e Legionella spp. não foram isoladas de qualquer das amostras de água das torneiras e dos equipos odontológicos (AU)