Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Neurobiol Dis ; 143: 105009, 2020 09.
Article in English | MEDLINE | ID: mdl-32634578

ABSTRACT

Emerging evidence indicates that Huntington's disease (HD) may be described as multi-organ pathology. In this context, we and others have contributed to demonstrate that the disease is characterized by an impairment of the homeostasis of gastro-intestinal (GI) tract. Sphingolipids represent a class of molecules involved in the regulation and maintenance of different tissues and organs including GI system. In this study, we investigated whether the alteration of Sphingosine-1-phosphate (S1P) metabolism, previously described in human HD brains and animal models, is also detectable peripherally in R6/2 HD mice. Our findings indicate, for the first time, that sphingolipid metabolism is perturbed early in the disease in the intestinal tract of HD mice and, its modulation by K6PC-5, a selective activator of S1P synthesis, preserved intestinal integrity and homeostasis. These results further support the evidence that modulation of sphingolipid pathways may represent a potential therapeutic option in HD and suggest that it has also the potential to counteract the peripheral disturbances which may usually complicate the management of the disease and affect patient's quality of life.


Subject(s)
Amides/pharmacology , Huntington Disease/metabolism , Intestines/drug effects , Phosphotransferases (Alcohol Group Acceptor)/metabolism , Animals , Disease Models, Animal , Homeostasis/drug effects , Lysophospholipids/metabolism , Mice , Phosphotransferases (Alcohol Group Acceptor)/drug effects , Sphingolipids/metabolism , Sphingosine/analogs & derivatives , Sphingosine/metabolism
2.
Med Phys ; 42(8): 4678-84, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26233195

ABSTRACT

PURPOSE: To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. METHODS: EBT3 film samples were irradiated at the Istituto Nazionale di Fisica Nucleare-Laboratori Nazionali di Legnaro, Italy, with a 5 MeV proton beam generated by a 7 MV Van de Graaff CN accelerator. The nominal dose rates used were 2.1 Gy/min and 40 Gy/min. The delivered dose was determined by measuring the particle fluence and the energy spectrum in air with silicon surface barrier detector monitors. A preliminary study of the EBT3 film beam quality dependence in low-energy protons was conducted by passively degrading the beam energy. EBT3 films were also irradiated at ENEA-National Institute of Ionizing Radiation Metrology with gamma radiation produced by a (60)Co source characterized by an absorbed dose to water rate of 0.26 Gy/min as measured by a calibrated Farmer type ionization chamber. EBT3 film calibration curves were determined by means of a set of 40 film pieces irradiated to various doses ranging from 0.5 Gy to 30 Gy absorbed dose to water. An EPSON Expression 11000XL color scanner in transmission mode was used for film analysis. Scanner response stability, intrafilm uniformity, and interfilm reproducibility were verified. Optical absorption spectra measurements were performed on unirradiated and irradiated EBT3 films to choose the most sensitive color channel to the dose range used. RESULTS: EBT3 GafChromic films show an under response up to about 33% for low-energy protons with respect to (60)Co gamma radiation, which is consistent with the linear energy transfer dependence already observed with higher energy protons, and a negligible dose-rate dependence in the 2-40 Gy/min range. Short- and long-term scanner stabilities were 0.5% and 1.5%, respectively; film uniformity and reproducibility were better than 0.5%. CONCLUSIONS: The main purpose of this study was to implement EBT3 dosimetry in the proton low-energy radiobiology line of the TOP-IMPLART accelerator, having a maximum energy of 7 MeV. Low-energy proton and (60)Co calibrated sources were used to investigate the behavior of film response vs to be written in italicum dose. The calibration in 5 MeV protons is currently used for dose assessment in the radiobiological experiments at the TOP-IMPLART accelerator carried out at that energy value.


Subject(s)
Film Dosimetry/methods , Air , Calibration , Cobalt Radioisotopes/therapeutic use , Film Dosimetry/instrumentation , Gamma Rays , Proton Therapy , Radiation Dosage , Radiotherapy, Intensity-Modulated/instrumentation , Radiotherapy, Intensity-Modulated/methods , Silicon , Water
3.
Appl Radiat Isot ; 68(2): 275-9, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19914080

ABSTRACT

To determine photopeak efficiency for (99m)Tc of the NaI(Tl) detector used for liquid waste monitoring at the Nuclear Medicine Unit of IRCCS Paediatric Hospital Bambino Gesù in Rome, a specific experimental procedure, with traceability to primary standards, was developed. Working with the Italian National Institute for Occupational Prevention and Safety, two different calibration source geometries were employed and the detector response dependence on geometry was investigated. The large percentage difference (almost 40%) between the two efficiency values obtained showed that geometrical effects cannot be neglected.


Subject(s)
Medical Waste/analysis , Radiation Monitoring/instrumentation , Radiation Monitoring/standards , Radioactive Waste/analysis , Radiopharmaceuticals/analysis , Sodium Iodide/radiation effects , Calibration , Equipment Design , Equipment Failure Analysis , Radiation Dosage , Reference Standards , Reproducibility of Results , Rome , Sensitivity and Specificity , Solutions
SELECTION OF CITATIONS
SEARCH DETAIL
...