Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Diabetes Res Clin Pract ; 205: 110956, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37844798

ABSTRACT

AIMS: To evaluate the safety and performance of a hybrid closed-loop (HCL) system with automatic carbohydrate suggestion in adults with type 1 diabetes (T1D) prone to hypoglycemia. METHODS: A 32-hour in-hospital pilot study, including a night period, 4 meals and 2 vigorous unannounced 45-minute aerobic sessions, was conducted in 11 adults with T1D prone to hypoglycemia. The primary outcome was the percentage of time in range 70-180 mg/dL (TIR). Main secondary outcomes were time below range < 70 mg/dL (TBR < 70) and < 54 (TBR < 54). Data are presented as median (10th-90th percentile ranges). RESULTS: The participants, 6 (54.5%) men, were 24 (22-48) years old, and had 22 (9-32) years of T1D duration. All of them regularly used an insulin pump and a continuous glucose monitoring system. The median TIR was 78.7% (75.6-91.2): 92.7% (68.2-100.0) during exercise and recovery period, 79.3% (34.9-100.0) during postprandial period, and 95.4% (66.4-100.0) during overnight period. The TBR < 70 and TBR < 54 were 0.0% (0.0-6.6) and 0.0% (0.0-1.2), respectively. A total of 4 (3-9) 15-g carbohydrate suggestions were administered per person. No severe acute complications occurred during the study. CONCLUSIONS: The HCL system with automatic carbohydrate suggestion performed well and was safe in this population during challenging conditions in a hospital setting.


Subject(s)
Diabetes Mellitus, Type 1 , Hypoglycemia , Male , Adult , Humans , Young Adult , Middle Aged , Female , Insulin/adverse effects , Diabetes Mellitus, Type 1/drug therapy , Blood Glucose , Hypoglycemic Agents/adverse effects , Blood Glucose Self-Monitoring , Pilot Projects , Treatment Outcome , Insulin Infusion Systems , Hypoglycemia/epidemiology , Insulin, Regular, Human/therapeutic use
2.
J Clin Endocrinol Metab ; 106(1): 55-63, 2021 01 01.
Article in English | MEDLINE | ID: mdl-32852548

ABSTRACT

OBJECTIVE: To evaluate the safety and performance of a new multivariable closed-loop (MCL) glucose controller with automatic carbohydrate recommendation during and after unannounced and announced exercise in adults with type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: A randomized, 3-arm, crossover clinical trial was conducted. Participants completed a heavy aerobic exercise session including three 15-minute sets on a cycle ergometer with 5 minutes rest in between. In a randomly determined order, we compared MCL control with unannounced (CLNA) and announced (CLA) exercise to open-loop therapy (OL). Adults with T1D, insulin pump users, and those with hemoglobin (Hb)A1c between 6.0% and 8.5% were eligible. We investigated glucose control during and 3 hours after exercise. RESULTS: Ten participants (aged 40.8 ± 7.0 years; HbA1c of 7.3 ± 0.8%) participated. The use of the MCL in both closed-loop arms decreased the time spent <70 mg/dL of sensor glucose (0.0%, [0.0-16.8] and 0.0%, [0.0-19.2] vs 16.2%, [0.0-26.0], (%, [percentile 10-90]) CLNA and CLA vs OL respectively; P = 0.047, P = 0.063) and the number of hypoglycemic events when compared with OL (CLNA 4 and CLA 3 vs OL 8; P = 0.218, P = 0.250). The use of the MCL system increased the proportion of time within 70 to 180 mg/dL (87.8%, [51.1-100] and 91.9%, [58.7-100] vs 81.1%, [65.4-87.0], (%, [percentile 10-90]) CLNA and CLA vs OL respectively; P = 0.227, P = 0.039). This was achieved with the administration of similar doses of insulin and a reduced amount of carbohydrates. CONCLUSIONS: The MCL with automatic carbohydrate recommendation performed well and was safe during and after both unannounced and announced exercise, maintaining glucose mostly within the target range and reducing the risk of hypoglycemia despite a reduced amount of carbohydrate intake.Register Clinicaltrials.gov: NCT03577158.


Subject(s)
Diabetes Mellitus, Type 1/therapy , Dietary Carbohydrates/administration & dosage , Exercise/physiology , Pancreas, Artificial , Adult , Blood Glucose/analysis , Blood Glucose/metabolism , Blood Glucose Self-Monitoring/instrumentation , Cross-Over Studies , Diabetes Mellitus, Type 1/blood , Equipment Design , Equipment Failure Analysis , Female , Glycemic Control/instrumentation , Glycemic Control/methods , Humans , Insulin/administration & dosage , Insulin Infusion Systems , Male , Middle Aged , Spain , Suggestion
SELECTION OF CITATIONS
SEARCH DETAIL
...