Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Sensors (Basel) ; 24(9)2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38732907

ABSTRACT

This paper addresses the issue of LED short-circuit fault detection in signaling and lighting systems in the automotive industry. The conventional diagnostic method commonly implemented in newer vehicles relies on measuring the voltage drop across different LED branches and comparing it with threshold values indicating faults caused by open circuits or LED short circuits. With this algorithm, detecting cases of a few LEDs short-circuited within a branch, particularly a single malfunctioning LED, is particularly challenging. In this work, two easily implementable algorithms are proposed to address this issue within the vehicle's control unit. One is based on a mathematical prediction model, while the other utilizes a neural network. The results obtained offer a 100% LED short-circuit fault detection rate in the majority of analyzed cases, representing a significant improvement over the conventional method, even in scenarios involving a single malfunctioning LED within a branch. Additionally, the neural network-based model can accurately predict the number of failed LEDs.

2.
Sensors (Basel) ; 22(11)2022 May 28.
Article in English | MEDLINE | ID: mdl-35684732

ABSTRACT

In this work, we present a ballistocardiographic (BCG) system for the determination of heart and breath rates and activity of a user lying in bed. Our primary goal was to simplify the analog and digital processing usually required in these kinds of systems while retaining high performance. A novel sensing approach is proposed consisting of a white LED facing a digital light detector. This detector provides precise measurements of the variations of the light intensity of the incident light due to the vibrations of the bed produced by the subject's breathing, heartbeat, or activity. Four small springs, acting as a bandpass filter, connect the boards where the LED and the detector are mounted. Owing to the mechanical bandpass filtering caused by the compressed springs, the proposed system generates a BCG signal that reflects the main frequencies of the heartbeat, breathing, and movement of the lying subject. Without requiring any analog signal processing, this device continuously transmits the measurements to a microcontroller through a two-wire communication protocol, where they are processed to provide an estimation of the parameters of interest in configurable time intervals. The final information of interest is wirelessly sent to the user's smartphone by means of a Bluetooth connection. For evaluation purposes, the proposed system has been compared with typical BCG systems showing excellent performance for different subject positions. Moreover, applied postprocessing methods have shown good behavior for information separation from a single-channel signal. Therefore, the determination of the heart rate, breathing rate, and activity of the patient is achieved through a highly simplified signal processing without any need for analog signal conditioning.


Subject(s)
Ballistocardiography , Humans , Ballistocardiography/methods , Heart Rate/physiology , Signal Processing, Computer-Assisted , Sleep
3.
Talanta ; 216: 120985, 2020 Aug 15.
Article in English | MEDLINE | ID: mdl-32456894

ABSTRACT

In this work, a freshness colorimetric sensor has been integrated with pork meat packages. The sensor tracks rising CO2 levels in the package associated with meat spoilage, as CO2 levels increase with bacterial population. The color of the sensor changes depending on the quantity of bacteria present, therefore it can be correlated with the freshness of meat, in this case pork loin. Detection is achieved by a simple photograph using a smartphone, and analyzing the grey scale from the RGB space color with a custom made app. Only 2 µL of the cocktail (all components are nontoxic) is needed to prepare the sensor, which have been integrated inside meat packages using a variety of support materials prior to sealing. The Smartphone measurements have been validated using a reference method (Checkpoint Analyzer) and the results suggest it can provide the basis for a quick test of the quality of the packaged pork.


Subject(s)
Colorimetry , Meat/analysis , Smartphone , Animals , Food Packaging , Meat/microbiology , Swine
4.
Biosens Bioelectron ; 141: 111360, 2019 Sep 15.
Article in English | MEDLINE | ID: mdl-31176114

ABSTRACT

A versatile, compact and low-cost analytical platform has been designed, tested and validated to be used in the point-of-care settings. This passive measurement system is powered and complemented by a standard smartphone including a programmed application for measurement configuration and data processing as well as wireless results sharing. Electrochemical and electrochemiluminescence analytical techniques can be configured and realized by this platform that employs standard screen-printed electrodes for the sample managing and off-the-shelf electronic components. The power, electrical and optical signal processing have been studied in depth. The system can harvest energy up to 22.5 mW, set up a voltage in the range of ±1.15 V, and measure potentials in a range of 600 mV with an uncertainty of 1 mV, and current from 2 µA to 0.75 mA with a resolution of 1.1 µA. Moreover, standard tests have been performed to the platform consisting of amperometric, potentiometric, cyclic voltammetry and electrochemiluminescent analytical techniques, showing excellent agreement with a reference instrument. Finally, our design has also been applied to glucose, pH and H2O2 determinations, providing the full analytical parameters which are in very good agreement with the reference instrument results. Ranges (0.065-0.75 M, 0.62-100 mM and 3-9 pH units for glucose, H2O2 and pH, respectively) and limits of detection (0.024 M and 0.03 mM for glucose and H2O2, respectively) make this low-cost platform (

Subject(s)
Biosensing Techniques/instrumentation , Point-of-Care Systems , Smartphone/instrumentation , Equipment Design , Glucose/analysis , Humans , Hydrogen Peroxide/analysis , Hydrogen-Ion Concentration , Limit of Detection , Wireless Technology/instrumentation
5.
Sensors (Basel) ; 16(7)2016 Jul 14.
Article in English | MEDLINE | ID: mdl-27428973

ABSTRACT

This work presents the design, fabrication, and characterization of a passive printed radiofrequency identification tag in the ultra-high-frequency band with multiple optical sensing capabilities. This tag includes five photodiodes to cover a wide spectral range from near-infrared to visible and ultraviolet spectral regions. The tag antenna and circuit connections have been screen-printed on a flexible polymeric substrate. An ultra-low-power microcontroller-based switch has been included to measure the five magnitudes issuing from the optical sensors, providing a spectral fingerprint of the incident electromagnetic radiation from ultraviolet to infrared, without requiring energy from a battery. The normalization procedure has been designed applying illuminants, and the entire system was tested by measuring cards from a colour chart and sensing fruit ripening.

6.
Anal Bioanal Chem ; 408(11): 3013-20, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26869344

ABSTRACT

A portable reconfigurable platform for copper (Cu(II)) determination based on luminescent carbon dot (Cdots) quenching is described. The electronic setup consists of a light-emitting diode (LED) as the carbon dot optical exciter and a photodiode as a light-to-current converter integrated in the same instrument. Moreover, the overall analog conditioning is simply performed with one integrated solution, a field-programmable analog array (FPAA), which makes it possible to reconfigure the filter and gain stages in real time. This feature provides adaptability to use the platform as an analytical probe for carbon dots coming from different batches with some variations in luminescence characteristics. The calibration functions obtained that fit a modified Stern-Volmer equation were obtained using luminescence signals from Cdots quenching by Cu(II). The analytical applicability of the reconfigurable portable instrument for Cu(II) using Cdots has been successfully demonstrated in tap water analysis.


Subject(s)
Carbon/chemistry , Copper/analysis , Luminescence , Reference Standards , X-Ray Diffraction
7.
Anal Chim Acta ; 899: 23-56, 2015 Oct 29.
Article in English | MEDLINE | ID: mdl-26547492

ABSTRACT

Chemical analysis based on colour changes recorded with imaging devices is gaining increasing interest. This is due to its several significant advantages, such as simplicity of use, and the fact that it is easily combinable with portable and widely distributed imaging devices, resulting in friendly analytical procedures in many areas that demand out-of-lab applications for in situ and real-time monitoring. This tutorial review covers computer vision-based analytical (CVAC) procedures and systems from 2005 to 2015, a period of time when 87.5% of the papers on this topic were published. The background regarding colour spaces and recent analytical system architectures of interest in analytical chemistry is presented in the form of a tutorial. Moreover, issues regarding images, such as the influence of illuminants, and the most relevant techniques for processing and analysing digital images are addressed. Some of the most relevant applications are then detailed, highlighting their main characteristics. Finally, our opinion about future perspectives is discussed.

8.
Sensors (Basel) ; 12(5): 6746-63, 2012.
Article in English | MEDLINE | ID: mdl-22778668

ABSTRACT

The aim of this work was the determination of pH with a sensor array-based optical portable instrument. This sensor array consists of eleven membranes with selective colour changes at different pH intervals. The method for the pH calculation is based on the implementation of artificial neural networks that use the responses of the membranes to generate a final pH value. A multi-objective algorithm was used to select the minimum number of sensing elements required to achieve an accurate pH determination from the neural network, and also to minimise the network size. This helps to minimise instrument and array development costs and save on microprocessor energy consumption. A set of artificial neural networks that fulfils these requirements is proposed using different combinations of the membranes in the sensor array, and is evaluated in terms of accuracy and reliability. In the end, the network including the response of the eleven membranes in the sensor was selected for validation in the instrument prototype because of its high accuracy. The performance of the instrument was evaluated by measuring the pH of a large set of real samples, showing that high precision can be obtained in the full range.

9.
Sensors (Basel) ; 9(10): 7694-710, 2009.
Article in English | MEDLINE | ID: mdl-22408475

ABSTRACT

A hand-held luminometer for measuring electrochemiluminescence (ECL) for lactate determination and based on one-shot biosensors fabricated using screen-printed electrodes is described. The lactate recognition system is based on lactate oxidase and the transduction system consists of electro-oxidation of luminol, with all the reagents immobilized in a Methocel membrane. The membrane composition and reaction conditions have been optimized to obtain adequate sensitivity. The luminometer is based on a large silicon photodiode as detector and includes a programmable potentiostat to initialize the chemical reaction and signal processing circuitry, designed to acquire a low level photocurrent with offset cancelation, low pass filtering for noise attenuation and adjustable gain up to 10(12) V/A. The one-shot biosensor responds to lactate rapidly, with an acquisition time of 2.5 min, obtaining a linear dependence from 8 × 10(-6) to 2 × 10(-4) M, a detection limit of 2.4 × 10(-6) M and a sensor-to-sensor reproducibility (relative standard deviation, RSD) of around 7-10 % at the medium level of the range.

SELECTION OF CITATIONS
SEARCH DETAIL
...