J Hosp Infect ; 152: 114-121, 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39032568

ABSTRACT

BACKGROUND: A new medical device was developed for multi-infusion in neonatal intensive care units (NICUs) with the aim of addressing issues related to drug incompatibilities and central-line-associated bloodstream infections (CLABSIs). AIM: To assess the cost-effectiveness of implementing this new perfusion system in an NICU setting. METHODS: This single-centre, observational study was conducted in all infants admitted to the NICU within 3 days of birth, and who required a central venous line, to evaluate the cost and effectiveness before (2019) and after (2020) implementation of the new perfusion system. Costs were calculated from the hospital perspective, and the incidence of CLABSIs was examined over a time horizon from NICU admission to discharge. Resource utilization was measured (infusion device, infection-treating drugs and biological analyses), and corresponding costs were valued using tariffs for 2019. The incremental cost-effectiveness ratio (ICER) was calculated, expressed as Euros per CLABSI avoided, and one-way and multi-variate sensitivity analyses were conducted. FINDINGS: Among 609 infants selected, clinical characteristics were similar across both periods. The CLABSI rate decreased significantly (rate ratio 0.22, 95% confidence interval 0.07-0.56), and total costs reduced from €65,666 to €63,932 per 1000 catheter-days (P<0.001) after implementation of the new perfusion system, giving an ICER of €251 saved per CLABSI avoided. The majority of sensitivity analyses showed that the new intervention remained economically dominant. CONCLUSION: This single-centre study showed a significant decrease in the incidence of CLABSIs after implementation of the new perfusion system, without incurring additional costs. Further prospective multi-centre randomized studies are needed to confirm these results in other NICUs.

2.
J Hosp Infect ; 143: 203-212, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37858805

ABSTRACT

BACKGROUND: Central-venous-line-associated bloodstream infection (CLABSI) is a significant cause of morbidity and mortality in preterm infants. As there is large variation in the reported effect of multi-modal preventive strategies, it could be relevant to propose new additional strategies. AIM: To assess the impact of a new perfusion system on CLABSI rate. METHODS: A before-and-after study was performed in infants born at <32 weeks of gestation or with birth weight <1500 g who required a multi-perfusion system connected to a central venous line. In the first 12-month period ('before'), the pre-existing perfusion system (multiple stopcocks) was used. An intervention period then occurred with implementation of a new perfusion closed system, without change in 'bundles' related to various aspects of central line care. During the second 12-month period ('after'), the CLABSI rate was assessed and compared with the pre-intervention period. FINDINGS: In total, 313 infants were included in this study (before: N=163; after: N=150), and 46% had birth weight <1000 g. The change in perfusion system resulted in a significant decrease in CLABSI rate from 11.3 to 2.2 per 1000 catheter-days (P<0.001). The period was independently associated with an 88% reduction in the risk of CLABSI after implementation of the new perfusion system [odds ratio (OR) 0.12, 95% confidence interval (CI) 0.03-0.39; P<0.001]. The duration of central line use was also associated with CLABSIs (for each additional day: OR 1.05, 95% CI 1.02-1.07; P<0.001). CONCLUSIONS: Implementation of the new perfusion system was feasible in a large neonatal unit, and reduced the CLABSI rate soon after implementation.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Central Venous Catheters , Sepsis , Humans , Infant, Newborn , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Catheter-Related Infections/epidemiology , Catheter-Related Infections/prevention & control , Infant, Premature , Birth Weight , Sepsis/epidemiology , Sepsis/prevention & control , Perfusion , Infant, Very Low Birth Weight
SELECTION OF CITATIONS
SEARCH DETAIL