Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Endosc Int Open ; 3(6): E547-51, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26716109

ABSTRACT

BACKGROUND AND STUDY AIMS: Endoscopic Vacuum Therapy (EVT) has been reported as a novel treatment option for esophageal leakage. We present our results in the treatment of iatrogenic perforation with EVT in a case series of 10 patients. PATIENTS AND METHODS: An open pore polyurethane drainage was placed either intracavitary through the perforation defect or intraluminal covering the defect zone. Application of vacuum suction with an electronic device (continuous negative pressure, -125 mmHg) resulted in defect closure and internal drainage. RESULTS: Esophageal perforations were located from the cricopharyngeus (4/10) to the esophagogastric junction (2/10). EVT was feasible in all patients. Eight patients were treated with intraluminal EVT, one with intracavitary EVT, and one with both types of treatments. All perforations (100 %) were healed in within a median of (3 - 7) days. No stenosis occurred, no complications were observed, and no additional operative treatment was necessary. CONCLUSIONS: Our study suggests that intraluminal EVT will play an important role in endoscopic management of esophageal perforation.

3.
Biomed Eng Online ; 10: 104, 2011 Dec 02.
Article in English | MEDLINE | ID: mdl-22136408

ABSTRACT

BACKGROUND: In recent years, intra arterial chemotherapy has become an important component in head and neck cancer treatment. However, therapy success can vary significantly and consistent treatment guidelines are missing. The purpose of this study was to create a computer simulation of the chemical agent injection in the head and neck arteries to investigate the distribution and concentration of the chemical. METHODS: Realistic three dimensional patient specific geometry was created from image scan data. Pulsatile blood flow, turbulence, the chemical agent injection via a catheter, and the mixture between blood and the chemical were then simulated through the arterial network by computational fluid dynamics software. RESULTS: The results show a consistent chemical distribution throughout all the arteries and this is ineffective. In addition, due to high wall shear stress and turbulence at the inner bifurcation wall, serious complications during the treatment could occur, for instance haemolysis or thrombosis. CONCLUSIONS: The modelled catheter position is insufficient to provide a high chemical agent concentration in the desired tumour feeding artery, which is vital for therapy success.


Subject(s)
Antineoplastic Agents/pharmacokinetics , Head and Neck Neoplasms/drug therapy , Head and Neck Neoplasms/physiopathology , Hemodynamics , Models, Biological , Antineoplastic Agents/therapeutic use , Humans , Injections
SELECTION OF CITATIONS
SEARCH DETAIL
...