Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 218
Filter
1.
CNS Drugs ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951464

ABSTRACT

Clozapine-induced myocarditis (CIM) is among the most important adverse events limiting the use of clozapine as the most effective treatment for schizophrenia. CIM necessitates the immediate termination of clozapine, often resulting in its permanent discontinuation with considerable detrimental effects on patients' psychopathology and long-term outcome. Consequently, a clozapine re-challenge after CIM is increasingly regarded as a viable alternative, with published reports indicating a success rate of approximately 60%. However, published cases of re-challenges after CIM remain limited. Here, we provide a narrative review of the current state of research regarding the epidemiology, pathophysiology, risk factors, diagnosis and clinical management of CIM as well as a synthesis of current recommendations for re-challenging patients after CIM. This includes a step-by-step guide for this crucial procedure based on the current evidence regarding the pathophysiology and risk factors for CIM. Slow dose titration regimes and addressing risk factors including concomitant valproate and olanzapine are crucial both to prevent CIM and to ensure a safe and successful re-challenge. Furthermore, we discuss the utility of C-reactive protein, troponin, N-terminal-pro hormone and brain natriuretic peptide, therapeutic drug-monitoring and cardiac magnetic resonance imaging for CIM screening and diagnosis as well as for post-CIM re-challenges.

2.
Acad Radiol ; 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38862346

ABSTRACT

RATIONALE AND OBJECTIVES: This retrospective study evaluates the efficacy and safety of Prostatic Artery Embolization (PAE) for the treatment of benign prostatic hyperplasia (BPH) over five years at a single center, conducted by an experienced interventional radiologist. MATERIALS AND METHODS: We analyzed 551 PAE interventions from January 2019 to July 2023. Key metrics included patient demographics, procedural details (radiation exposure, particle size), complication rates, pre- and post-interventional prostatic volume (PV), Prostate-specific Antigen (PSA) levels, International Prostate Symptom Score (IPSS), Quality of Life (QoL) scores and International Index of Erectile Function (IIEF) scores. We assessed data normality, performed group and paired sample comparisons, and evaluated correlations. RESULTS: For 551 men, the average patient age was 68.81 ± 8.61 years undergoing bilateral embolization. The particle size predominantly used was 100-300 µm (n = 441). PAE lead to significant (p < .001) reduction of both PV (-9.67 ± 14.52 mL) and PSA level (-2,65 ± 1.56 ng/mL) between pre- and three months after PAE. Substantial improvement were observed for IPSS (-9 points) and QoL scores (-2 points), with stable IIEF scores. Only minor complications (n = 16) were reported, and no major complications were observed. Between the first PAE in 2019 and the routinely performed PAE in 2023 significant (p < .0001) reductions in fluoroscopy (-25.2%), and procedural times (-26.1%) were observed. CONCLUSION: In conclusion, PAE is a safe and effective treatment for BPH, offering significant improvements in lower urinary tract symptoms (LUTS) and QoL while maintaining sexual function.

3.
Sci Rep ; 14(1): 13295, 2024 06 10.
Article in English | MEDLINE | ID: mdl-38858499

ABSTRACT

Non-tuberculous mycobacterial pulmonary disease (NTM-PD) is considered a growing health concern. The majority of NTM-PD cases in Europe are caused by slow-growing mycobacteria (SGM). However, distinct radiological features of different SGM remain largely uninvestigated. We applied a previously described radiological score to a patient cohort consisting of individuals with isolation of different SGM. Correlations between clinical data, species and computed tomography (CT) features were examined by logistic and linear regression analyses, as well as over the course of time. Overall, 135 pulmonary CT scans from 84 patients were included. The isolated NTM-species were mainly Mycobacterium avium complex (MAC, n = 49), as well as 35 patients with non-MAC-species. Patients with isolation of M. intracellulare had more extensive CT findings compared to all other SGM species (coefficient 3.53, 95% Cl - 0.37 to 7.52, p = 0.075) while patients meeting the ATS criteria and not undergoing therapy exhibited an increase in CT scores over time. This study provides insights into differential radiological features of slow-growing NTM. While M. intracellulare exhibited a tendency towards higher overall CT scores, the radiological features were similar across different SGM. The applied CT score might be a useful instrument for monitoring patients and could help to guide antimycobacterial therapy.


Subject(s)
Mycobacterium Infections, Nontuberculous , Nontuberculous Mycobacteria , Tomography, X-Ray Computed , Humans , Male , Female , Mycobacterium Infections, Nontuberculous/diagnostic imaging , Mycobacterium Infections, Nontuberculous/microbiology , Tomography, X-Ray Computed/methods , Aged , Middle Aged , Nontuberculous Mycobacteria/isolation & purification , Nontuberculous Mycobacteria/growth & development , Mycobacterium avium Complex/isolation & purification , Lung/microbiology , Lung/diagnostic imaging , Retrospective Studies , Adult , Mycobacterium avium-intracellulare Infection/diagnostic imaging , Mycobacterium avium-intracellulare Infection/microbiology
4.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38872126

ABSTRACT

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Subject(s)
Cochlear Implants , Cone-Beam Computed Tomography , Radiation Dosage , Temporal Bone , Humans , Cone-Beam Computed Tomography/methods , Male , Middle Aged , Female , Retrospective Studies , Temporal Bone/diagnostic imaging , Aged , Adult , Cochlear Implantation/methods
5.
Scand J Med Sci Sports ; 34(5): e14644, 2024 May.
Article in English | MEDLINE | ID: mdl-38760915

ABSTRACT

Overuse injuries, which have a high prevalence in sport, are suggested to result in different affective responses in comparison to traumatic injuries. Affects may also reciprocally act as risk factors for overuse injury. The aim of this study was to examine the associations between overuse injury and affects within a longitudinal follow-up design. Competitive athletes (N = 149) of various sports and levels of competition completed the Positive and Negative Affect Schedule (PANAS) and the Oslo Sports Trauma Research Centre Overuse injury questionnaire (OSTRC-O) once a week over 10 consecutive weeks. Bivariate unconditional latent curve model analyses with structured residuals were performed to evaluate the associations within and across weeks between OSTRC-O severity score and affects. Results indicated that OSTRC-O severity score and positive affects (PA) had a statistically significant negative within-week relation (r = -24.51, 95% CI = [-33.9, -15.1], p < 0.001). Higher scores of overuse injury were significantly related to lower levels of PA across weeks (ß = -0.02, 95% CI = [-0.04, -0.001], p = 0.044), while the reciprocal effect of PA on overuse injury was not significant (ß = -0.13, 95% CI = [-0.52, 0.26], p = 0.51). No statistically significant association was observed between OSTRC-O severity score and negative affects, neither within nor across weeks. Our findings suggest that overuse injury may have adverse psychological consequences on the long run through lessened PA and address the need for providing sustainable psychological support focusing upon such PA when working with athletes experiencing overuse injury.


Subject(s)
Athletic Injuries , Cumulative Trauma Disorders , Humans , Cumulative Trauma Disorders/psychology , Male , Female , Athletic Injuries/psychology , Longitudinal Studies , Prospective Studies , Adult , Young Adult , Surveys and Questionnaires , Affect , Risk Factors , Adolescent , Competitive Behavior/physiology , Norway/epidemiology , Athletes/psychology
6.
Article in English | MEDLINE | ID: mdl-38762707

ABSTRACT

An accurate diagnosis of venous thromboembolism (VTE) is crucial, given the potential for high mortality in undetected cases. Strategic D-dimer testing may aid in identifying low-risk patients, preventing overdiagnosis and reducing imaging costs. We conducted a retrospective, comparative analysis to assess the potential cost savings that could be achieved by adopting different approaches to determine the most effective D-dimer cut-off value in cancer patients with suspected VTE, compared to the commonly used rule-out cut-off level of 0.5 mg/L. The study included 526 patients (median age 65, IQR 55-75) with a confirmed cancer diagnosis who underwent D-dimer testing. Among these patients, the VTE prevalence was 29% (n = 152). Each diagnostic strategy's sensitivity, specificity, negative likelihood ratio (NLR), as well as positive likelihood ratio (PLR), and the proportion of patients exhibiting a negative D-dimer test result, were calculated. The diagnostic strategy that demonstrated the best balance between specificity, sensitivity, NLR, and PLR, utilized an inverse age-specific cut-off level for D-dimer [0.5 + (66-age) × 0.01 mg/L]. This method yielded a PLR of 2.9 at a very low NLR for the exclusion of VTE. We observed a significant cost reduction of 4.6% and 1.0% for PE and DVT, respectively. The utilization of an age-adjusted cut-off [patient's age × 0.01 mg/L] resulted in the highest cost savings, reaching 8.1% for PE and 3.4% for DVT. Using specified D-dimer cut-offs in the diagnosis of VTE could improve economics, considering the limited occurrence of confirmed cases among patients with suspected VTE.

7.
Diagnostics (Basel) ; 14(7)2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38611610

ABSTRACT

(1) Background: Low bone mineral density (BMD) is a significant risk factor for complicated surgery and leads to the increased use of bone substitutes in patients with distal radius fractures (DRFs). No accepted model has yet been established to predict the use of bone substitutes to facilitate preoperative planning. (2) Methods: Unenhanced dual-energy CT (DECT) images of DRFs were retrospectively acquired between March 2016 and September 2020 using the internal PACS system. Available follow-up imaging and medical health records were reviewed to determine the use of bone substitutes. DECT-based BMD, trabecular Hounsfield units (HU), cortical HU, and cortical thickness ratio were measured in non-fractured segments of the distal radius. Diagnostic accuracy parameters were calculated for all metrics using receiver-operating characteristic (ROC) curves and associations of all metrics with the use of bone substitutes were evaluated using logistic regression models. (3) The final study population comprised 262 patients (median age 55 years [IQR 43-67 years]; 159 females, 103 males). According to logistic regression analysis, DECT-based BMD was the only metric significantly associated with the use of bone substitutes (odds ratio 0.96, p = 0.003). However, no significant associations were found for cortical HU (p = 0.06), trabecular HU (p = 0.33), or cortical thickness ratio (p = 0.21). ROC-curve analysis revealed that a combined model of all four metrics had the highest diagnostic accuracy with an area under the curve (AUC) of 0.76. (4) Conclusions: DECT-based BMD measurements performed better than HU-based measurements and cortical thickness ratio. The diagnostic performance of all four metrics combined was superior to that of the individual parameters.

8.
Acad Radiol ; 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38519304

ABSTRACT

RATIONALE AND OBJECTIVES: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration. PATIENTS AND METHODS: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality. RESULTS: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0-93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC=0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4). CONCLUSION: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.

9.
Acad Radiol ; 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38461052

ABSTRACT

RATIONALE AND OBJECTIVES: Bone non-union is a serious complication of distal radius fractures (DRF) that can result in functional limitations and persistent pain. However, no accepted method has been established to identify patients at risk of developing bone non-union yet. This study aimed to compare various CT-derived metrics for bone mineral density (BMD) assessment to identify predictive values for the development of bone non-union. MATERIALS AND METHODS: CT images of 192 patients with DRFs who underwent unenhanced dual-energy CT (DECT) of the distal radius between 03/2016 and 12/2020 were retrospectively identified. Available follow-up imaging and medical health records were evaluated to determine the occurrence of bone non-union. DECT-based BMD, trabecular Hounsfield unit (HU), cortical HU and cortical thickness ratio were measured in normalized non-fractured segments of the distal radius. RESULTS: Patients who developed bone non-union were significantly older (median age 72 years vs. 54 years) and had a significantly lower DECT-based BMD (median 68.1 mg/cm3 vs. 94.6 mg/cm3, p < 0.001). Other metrics (cortical thickness ratio, cortical HU, trabecular HU) showed no significant differences. ROC and PR curve analyses confirmed the highest diagnostic accuracy for DECT-based BMD with an area under the curve (AUC) of 0.83 for the ROC curve and an AUC of 0.46 for the PR curve. In logistic regression models, DECT-based BMD was the sole metric significantly associated with bone non-union. CONCLUSION: DECT-derived metrics can accurately predict bone non-union in patients who sustained DRF. The diagnostic performance of DECT-based BMD is superior to that of HU-based metrics and cortical thickness ratio.

10.
Radiol Cardiothorac Imaging ; 6(2): e230096, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38546330

ABSTRACT

Purpose To examine the clinical feasibility of workstation-based CT fractional flow reserve (CT-FFR) for coronary artery disease (CAD) evaluation during preprocedural planning in patients undergoing transcatheter aortic valve replacement (TAVR). Materials and Methods In this retrospective single-center study, 434 patients scheduled for TAVR between 2018 and 2020 were screened for study inclusion; a relevant proportion of patients (35.0% [152 of 434]) was not suitable for evaluation due to insufficient imaging properties. A total of 112 patients (mean age, 82.1 years ± 6.7 [SD]; 58 [52%] men) were included in the study. Invasive angiography findings, coronary CT angiography results, and Agatston score were acquired and compared with on-site CT-FFR computation for evaluation of CAD and prediction of major adverse cardiovascular events (MACE) within a 24-month follow-up. Results Hemodynamic relevant CAD, as suggested by CT-FFR of 0.80 or less, was found in 41 of 70 (59%) patients with stenosis of 50% or more. MACE occurred in 23 of 112 (20.5%) patients, from which 14 of 23 had stenoses with CT-FFR of 0.80 or less (hazard ratio [HR], 3.33; 95% CI: 1.56, 7.10; P = .002). CT-FFR remained a significant predictor of MACE after inclusion in a multivariable model with relevant covariables (HR, 2.89; 95% CI: 1.22, 6.86; P = .02). An Agatston score of 1000 Agatston units or more (HR, 2.25; 95% CI: 0.98, 5.21; P = .06) and stenoses of 50% or more determined via invasive angiography (HR, 0.94; 95% CI: 0.41, 2.17; P = .88) were not significant predictors of MACE. Conclusion Compared with conventional CAD markers, CT-FFR better predicted adverse outcomes after TAVR. A relevant portion of the screened cohort, however, was not suitable for CT-based CAD evaluation. Keywords: CT, Transcatheter Aortic Valve Implantation/Replacement (TAVI/TAVR), Cardiac, Coronary Arteries, Outcomes Analysis © RSNA, 2024 See also the commentary by Weir-McCall and Pugliese in this issue.


Subject(s)
Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Female , Coronary Artery Disease/diagnostic imaging , Transcatheter Aortic Valve Replacement/adverse effects , Constriction, Pathologic , Retrospective Studies , Coronary Angiography
11.
Emerg Radiol ; 31(3): 303-311, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38523224

ABSTRACT

PURPOSE: Recent advancements in medical imaging have transformed diagnostic assessments, offering exciting possibilities for extracting biomarker-based information. This study aims to investigate the capabilities of a machine learning classifier that incorporates dual-energy computed tomography (DECT) radiomics. The primary focus is on discerning and predicting outcomes related to pulmonary embolism (PE). METHODS: The study included 131 participants who underwent pulmonary artery DECT angiography between January 2015 and March 2022. Among them, 104 patients received the final diagnosis of PE and 27 patients served as a control group. A total of 107 radiomic features were extracted for every case based on DECT imaging. The dataset was divided into training and test sets for model development and validation. Stepwise feature reduction identified the most relevant features, which were used to train a gradient-boosted tree model. Receiver operating characteristics analysis and Cox regression tests assessed the association of texture features with overall survival. RESULTS: The trained machine learning classifier achieved a classification accuracy of 0.94 for identifying patients with acute PE with an area under the receiver operating characteristic curve of 0.91. Radiomics features could be valuable for predicting outcomes in patients with PE, demonstrating strong prognostic capabilities in survival prediction (c-index, 0.991 [0.979-1.00], p = 0.0001) with a median follow-up of 130 days (IQR, 38-720). Notably, the inclusion of clinical or DECT parameters did not enhance predictive performance. CONCLUSION: In conclusion, our study underscores the promising potential of leveraging radiomics on DECT imaging for the identification of patients with acute PE and predicting their outcomes. This approach has the potential to improve clinical decision-making and patient management, offering efficiencies in time and resources by utilizing existing DECT imaging without the need for an additional scoring system.


Subject(s)
Computed Tomography Angiography , Machine Learning , Pulmonary Embolism , Humans , Pulmonary Embolism/diagnostic imaging , Male , Female , Prognosis , Middle Aged , Computed Tomography Angiography/methods , Aged , Biomarkers/blood , Predictive Value of Tests , Retrospective Studies
12.
Mol Biol Evol ; 41(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38401262

ABSTRACT

Hypolimnas misippus is a Batesian mimic of the toxic African Queen butterfly (Danaus chrysippus). Female H. misippus butterflies use two major wing patterning loci (M and A) to imitate three color morphs of D. chrysippus found in different regions of Africa. In this study, we examine the evolution of the M locus and identify it as an example of adaptive atavism. This phenomenon involves a morphological reversion to an ancestral character that results in an adaptive phenotype. We show that H. misippus has re-evolved an ancestral wing pattern present in other Hypolimnas species, repurposing it for Batesian mimicry of a D. chrysippus morph. Using haplotagging, a linked-read sequencing technology, and our new analytical tool, Wrath, we discover two large transposable element insertions located at the M locus and establish that these insertions are present in the dominant allele responsible for producing mimetic phenotype. By conducting a comparative analysis involving additional Hypolimnas species, we demonstrate that the dominant allele is derived. This suggests that, in the derived allele, the transposable elements disrupt a cis-regulatory element, leading to the reversion to an ancestral phenotype that is then utilized for Batesian mimicry of a distinct model, a different morph of D. chrysippus. Our findings present a compelling instance of convergent evolution and adaptive atavism, in which the same pattern element has independently evolved multiple times in Hypolimnas butterflies, repeatedly playing a role in Batesian mimicry of diverse model species.


Subject(s)
Biological Mimicry , Butterflies , Animals , Butterflies/genetics , DNA Transposable Elements , Biological Mimicry/genetics , Phenotype , Africa , Wings, Animal/anatomy & histology
13.
Alzheimers Dement (Amst) ; 16(1): e12467, 2024.
Article in English | MEDLINE | ID: mdl-38312514

ABSTRACT

INTRODUCTION: Age-related hearing loss is an important risk factor for cognitive decline. However, audiogram thresholds are not good estimators of dementia risk in subjects with normal hearing or mild hearing loss. Here we propose to use distortion product otoacoustic emissions (DPOAEs) as an objective and sensitive tool to estimate the risk of cognitive decline in older adults with normal hearing or mild hearing loss. METHODS: We assessed neuropsychological, brain magnetic resonance imaging, and auditory analyses on 94 subjects > 64 years of age. RESULTS: We found that cochlear dysfunction, measured by DPOAEs-and not by conventional audiometry-was associated with Clinical Dementia Rating Sum of Boxes (CDR-SoB) classification and brain atrophy in the group with mild hearing loss (25 to 40 dB) and normal hearing (<25 dB). DISCUSSION: Our findings suggest that DPOAEs may be a non-invasive tool for detecting neurodegeneration and cognitive decline in the older adults, potentially allowing for early intervention.

14.
BMJ Open Sport Exerc Med ; 10(1): e001768, 2024.
Article in English | MEDLINE | ID: mdl-38374942

ABSTRACT

Objective: To compare the perception towards injury risk reduction approach between athletes who have already experienced an injury and those who have not. Methods: We conducted a cross-sectional study using a one-time online survey asking athletics athletes licensed at the French Federation of Athletics (http://www.athle.fr) about their perceptions regarding injuries and injury risk reduction behaviours. We statistically compared athletes who already experienced an injury and those who did not. Results: A total of 7870 athletes were included. 90% of athletes declared having experienced at least one injury. They (1) were proportionally more men than women, (2) had significantly more years of experience in athletics, (3) had a significant difference in disciplines (more hurdles, jumps and combined events and fewer sprint athletes), (4) had a significant difference in competition levels (more national and less departmental levels) and (5) reported significantly higher values or agreements in favour of injury risk reduction approach, compared with uninjured athletes. There were significantly more athletes declaring following injury risk reduction programmes among athletes who experienced at least one injury than those who did not. Conclusions: Athletes who experienced at least one injury during their lifetime were more prone to adhere to injury risk reduction strategies than athletes who have never experienced an injury. Their entourage (coaches and health professionals) should use this fertile ground to implement injury risk reduction strategies. In addition, their experience should be disseminated to uninjured athletes to help them adhere to injury risk reduction without injury experience.

15.
Eur J Radiol ; 171: 111283, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38183896

ABSTRACT

BACKGROUND: Dual-energy CT (DECT)-derived bone mineral density (BMD) of the distal radius and other CT-derived metrics related to bone health have been suggested for opportunistic osteoporosis screening and risk evaluation for sustaining distal radius fractures (DRFs). METHODS: The distal radius of patients who underwent DECT between 01/2016 and 08/2021 was retrospectively analyzed. Cortical Hounsfield Unit (HU), trabecular HU, cortical thickness, and DECT-based BMD were acquired from a non-fractured, metaphyseal area in all examinations. Receiver-operating characteristic (ROC) analysis was conducted to determine the area under the curve (AUC) values for predicting DRFs based on DECT-derived BMD, HU values, and cortical thickness. Logistic regression models were then employed to assess the associations of these parameters with the occurrence of DRFs. RESULTS: In this study, 263 patients (median age: 52 years; interquartile range: 36-64; 132 women; 192 fractures) were included. ROC curve analysis revealed a higher area under the curve (AUC) value for DECT-derived BMD compared to cortical HU, trabecular HU, and cortical thickness (0.91 vs. 0.61, 0.64, and 0.69, respectively; p <.001). Logistic regression models confirmed the association between lower DECT-derived BMD and the occurrence of DRFs (Odds Ratio, 0.83; p <.001); however, no influence was observed for cortical HU, trabecular HU, or cortical thickness. CONCLUSIONS: DECT can be used to assess the BMD of the distal radius without dedicated equipment such as calibration phantoms to increase the detection rates of osteoporosis and stratify the individual risk to sustain DRFs. In contrast, assessing HU-based values and cortical thickness does not provide clinical benefit.


Subject(s)
Fractures, Bone , Osteoporosis , Humans , Female , Middle Aged , Radius , Absorptiometry, Photon , Retrospective Studies , Osteoporosis/diagnostic imaging , Bone Density , Tomography, X-Ray Computed , Risk Assessment
16.
Acad Radiol ; 31(6): 2610-2619, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38242733

ABSTRACT

BACKGROUND: The advent of advanced computed tomography (CT) technology and the field of radiomics has opened up new avenues in diagnostic assessments. Increasingly, there is substantial evidence advocating for the incorporation of quantitative imaging biomarkers in the clinical decision-making process. This study aimed to examine the correlation between D-dimer levels and thrombus size in acute pulmonary embolism (PE) combining dual-energy CT (DECT) and radiomics and to investigate the diagnostic utility of a machine learning classifier based on dual-energy computed tomography (DECT) radiomics for identifying patients with a complicated course, defined as at least hospitalization at IMC. METHODS: The study was conducted including 136 participants who underwent pulmonary artery CT angiography from January 2015 to March 2022. Based on DECT imaging, 107 radiomic features were extracted for each patient using standardized image processing. After dividing the dataset into training and test sets, stepwise feature reduction based on reproducibility, variable importance and correlation analyses were performed to select the most relevant features; these were used to train and validate the gradient-boosted tree models.Receiver operating characteristics (ROC) analysis was utilized to evaluate the association between volumetric, laboratory data and adverse outcomes. RESULTS: In the central PE group, we observed a significant correlation between thrombus volumetrics and D-dimer levels (p = 0.0037), as well as between thrombus volumetrics and hospitalization at the Intermediate Care Unit (IMC) (p = 0.0001). In contrast, no statistically significant differences were identified in thrombus sizes between patients who experienced complications and those who had a favorable course (p = 0.3162). The trained machine learning classifier achieved an accuracy of 61% and 55% in identifying patients with a complicated course, as indicated by an area under the ROC curve of 0.63 and 0.58. CONCLUSION: In conclusion, our findings indicate a positive correlation between D-dimer levels and central PE's pulmonary embolic burden. Thrombus volumetrics may serve as an indicator for complications and outcomes in acute PE patients. Thus, thrombus volumetrics, as opposed to D-dimers, could be an additional marker for evaluating embolic disease severity. Moreover, DECT-derived radiomic feature models show promise in identifying patients with a complicated course, such as hospitalization at IMC.


Subject(s)
Computed Tomography Angiography , Fibrin Fibrinogen Degradation Products , Hospitalization , Pulmonary Embolism , Humans , Pulmonary Embolism/diagnostic imaging , Pulmonary Embolism/blood , Female , Male , Fibrin Fibrinogen Degradation Products/metabolism , Middle Aged , Computed Tomography Angiography/methods , Thrombosis/diagnostic imaging , Thrombosis/blood , Machine Learning , Biomarkers/blood , Aged , Acute Disease , Reproducibility of Results , Retrospective Studies , Adult , Tomography, X-Ray Computed , Radiomics
17.
Eur J Clin Invest ; 54(4): e14139, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38063028

ABSTRACT

BACKGROUND: Technological progress in the acquisition of medical images and the extraction of underlying quantitative imaging data has introduced exciting prospects for the diagnostic assessment of a wide range of conditions. This study aims to investigate the diagnostic utility of a machine learning classifier based on dual-energy computed tomography (DECT) radiomics for classifying pulmonary embolism (PE) severity and assessing the risk for early death. METHODS: Patients who underwent CT pulmonary angiogram (CTPA) between January 2015 and March 2022 were considered for inclusion in this study. Based on DECT imaging, 107 radiomic features were extracted for each patient using standardized image processing. After dividing the dataset into training and test sets, stepwise feature reduction based on reproducibility, variable importance and correlation analyses were performed to select the most relevant features; these were used to train and validate the gradient-boosted tree models. RESULTS: The trained machine learning classifier achieved a classification accuracy of .90 for identifying high-risk PE patients with an area under the receiver operating characteristic curve of .59. This CT-based radiomics signature showed good diagnostic accuracy for risk stratification in individuals presenting with central PE, particularly within higher risk groups. CONCLUSION: Models utilizing DECT-derived radiomics features can accurately stratify patients with pulmonary embolism into established clinical risk scores. This approach holds the potential to enhance patient management and optimize patient flow by assisting in the clinical decision-making process. It also offers the advantage of saving time and resources by leveraging existing imaging to eliminate the necessity for manual clinical scoring.


Subject(s)
Pulmonary Embolism , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Radiomics , Reproducibility of Results , Pulmonary Embolism/diagnostic imaging , Risk Assessment , Retrospective Studies
18.
Eur J Radiol ; 170: 111235, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38071908

ABSTRACT

BACKGROUND: This study aimed to evaluate the clinical utility of modern single and dual-energy computed tomography (CT) for assessing the integrity of the cruciate ligaments in patients that sustained acute trauma. METHODS: Patients who underwent single- or dual-energy CT followed by 3 Tesla magnetic resonance imaging (MRI) or knee joint arthroscopy between 01/2016 and 12/2022 were included in this retrospective, monocentric study. Three radiologists specialized in musculoskeletal imaging independently evaluated all CT images for the presence of injury to the cruciate ligaments. An MRI consensus reading of two experienced readers and arthroscopy provided the reference standard. Diagnostic accuracy parameters and area under the receiver operator characteristic curve (AUC) were the primary metrics for diagnostic performance. RESULTS: CT images of 204 patients (median age, 49 years; IQR 36 - 64; 113 males) were evaluated. Dual-energy CT yielded significantly higher diagnostic accuracy and AUC for the detection of injury to the anterior (94% [240/255] vs 75% [266/357] and 0.89 vs 0.66) and posterior cruciate ligaments (95% [243/255] vs 87% [311/357] and 0.90 vs 0.61) compared to single-energy CT (all parameters, p <.005). Diagnostic confidence and image quality were significantly higher in dual-energy CT compared to single-energy CT (all parameters, p <.005). CONCLUSIONS: Modern dual-energy CT is readily available and can serve as a screening tool for detecting or excluding cruciate ligament injuries in patients with acute trauma. Accurate diagnosis of cruciate ligament injuries is crucial to prevent adverse outcomes, including delayed treatment, chronic instability, or long-term functional limitations.


Subject(s)
Anterior Cruciate Ligament Injuries , Knee Injuries , Posterior Cruciate Ligament , Male , Humans , Middle Aged , Retrospective Studies , Knee Injuries/pathology , Sensitivity and Specificity , Knee Joint/pathology , Posterior Cruciate Ligament/injuries , Anterior Cruciate Ligament Injuries/diagnostic imaging , Anterior Cruciate Ligament Injuries/pathology , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods
19.
J Comput Assist Tomogr ; 48(2): 323-333, 2024.
Article in English | MEDLINE | ID: mdl-38013237

ABSTRACT

OBJECTIVE: Our study objective was to explore the additional value of dual-energy CT (DECT) material decomposition for squamous cell carcinoma of the head and neck (SCCHN) survival prognostication. METHODS: A group of 50 SCCHN patients (male, 37; female, 13; mean age, 63.6 ± 10.82 years) with baseline head and neck DECT between September 2014 and August 2020 were retrospectively included. Primary tumors were segmented, radiomics features were extracted, and DECT material decomposition was performed. We used independent train and validation datasets with cross-validation and 100 independent iterations to identify prognostic signatures applying elastic net (EN) and random survival forest (RSF). Features were ranked and intercorrelated according to their prognostic importance. We benchmarked the models against clinical parameters. Intraclass correlation coefficients were used to analyze the interreader variation. RESULTS: The exclusively radiomics-trained models achieved similar ( P = 0.947) prognostic performance of area under the curve (AUC) = 0.784 (95% confidence interval [CI], 0.775-0.812) (EN) and AUC = 0.785 (95% CI, 0.759-0.812) (RSF). The additional application of DECT material decomposition did not improve the model's performance (EN, P = 0.594; RSF, P = 0.198). In the clinical benchmark, the top averaged AUC value of 0.643 (95% CI, 0.611-0.675) was inferior to the quantitative imaging-biomarker models ( P < 0.001). A combined imaging and clinical model did not improve the imaging-based models ( P > 0.101). Shape features revealed high prognostic importance. CONCLUSIONS: Radiomics AI applications may be used for SCCHN survival prognostication, but the spectral information of DECT material decomposition did not improve the model's performance in our preliminary investigation.


Subject(s)
Head and Neck Neoplasms , Radiomics , Humans , Male , Female , Middle Aged , Aged , Squamous Cell Carcinoma of Head and Neck/diagnostic imaging , Retrospective Studies , Tomography, X-Ray Computed/methods , Head and Neck Neoplasms/diagnostic imaging
20.
Rofo ; 2023 Dec 08.
Article in English | MEDLINE | ID: mdl-38065541

ABSTRACT

PURPOSE: To compare the therapeutic response and clinical outcome of CT-guided percutaneous microwave (MWA) and radiofrequency ablation (RFA) for the treatment of small- and medium-sized HCC. MATERIALS AND METHODS: In this prospective trial, 50 patients with HCC were randomly assigned to MWA or RFA treatment. MRI was performed 24 h before and after ablation and subsequently in 3-month intervals. Ablation volumes, ablation durations, adverse events (AE), technique efficacy, technical success, local tumor progression (LTP), disease-free survival (DFS), intrahepatic distant recurrence (IDR), and overall survival (OS) rates were evaluated. RESULTS: The mean ablation volume was 66.5 cm³ for MWA and 29.2  cm³ for RFA (p < 0.01). The mean ablation durations for MWA and RFA were 11.2 ±â€Š4.0 min and 16.3 ±â€Š4.7 min, respectively (p < 0.01). Six mild AEs were documented (p > 0.05). All treatments had a technical success rate and a technique efficacy rate of 100 % (50/50, p = 1.00). LTP within 2 years occurred in 1/25 (4 %) in the MWA group and in 4/25 (16 %) in the RFA group (p = 0.06). IDR within 2 years was 8/25 (32 %) for MWA and 14/25 (56 %) for RFA (p < 0.05). The median DFS was 24.5 months and 13.4 months for MWA and RFA, respectively (p = 0.02). The 1-, 2-, 3-year OS rates were 100 %, 80 %, 72 % in the MWA group and 72 %, 64 %, 60 % in the RFA group, respectively (p ≥ 0.14). CONCLUSION: The clinical outcome after MWA or RFA for HCC treatment was very similar with no significant differences in LTP or OS. However, MWA shows a trend toward better DFS with fewer IDRs than RFA. KEY POINTS: · MWA allows for larger ablation volumes and a shorter treatment duration compared to RFA in patients with HCC.. · MWA shows a trend toward better disease-free survival and fewer intrahepatic distant recurrences compared to RFA.. · The three-year survival rates show no significant difference between the two methods..

SELECTION OF CITATIONS
SEARCH DETAIL
...