Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
ASAIO J ; 46(4): 511-4, 2000.
Article in English | MEDLINE | ID: mdl-10926156

ABSTRACT

A postoperative enterocutaneous fistula is one of the most complex medical problems. Its treatment may become long-lasting, wearisome, and its outcome often is disappointing. Here, we describe the use of a novel device to treat a 67-year-old patient with a postoperative, high-output enterocutaneous fistula. A semipermeable barrier was created over the fistula by vacuum packing a synthetic, hydrophobic polymer covered with a self-adherent surgical sheet. To set up the system, we constructed a vacuum chamber equipped with precision instruments that supplied subatmospheric pressures between 350 and 450 mm Hg. The intestinal content was, thus, kept inside the lumen, restoring bowel transit and physiology. The fistula output was immediately reduced from a median of 800 ml/day (range, 400-1,600 ml/day), to a median of 10 ml/day (range, 0-250 ml/day), which was readily collected by the apparatus. Oral feeding was reinitiated while both parenteral nutrition and octreotide were withdrawn. No septic complications occurred, and the perifistular skin stayed protected from irritating intestinal effluents. Both the fistula orifice and the wound defect fully healed after 50 days of treatment. We believe this method may serve as a useful tool to treat selected cases of high-output enterocutaneous fistulas without the need for octreotide or parenteral nutrition.


Subject(s)
Cutaneous Fistula/therapy , Enteral Nutrition , Intestinal Fistula/therapy , Postoperative Complications/therapy , Aged , Humans , Male , Octreotide/therapeutic use , Parenteral Nutrition, Total
2.
ASAIO J ; 46(4): 505-10, 2000.
Article in English | MEDLINE | ID: mdl-10926155

ABSTRACT

Fulminant hepatic failure is an important cause of morbidity and mortality in intensive care units. Conventional therapies are not sufficiently effective. Liver transplantation may be life saving, but a "bridge therapy" is needed until transplantation is performed. Hepatic extracorporeal xenohemodiafiltration (XHDF) is aimed at the transitory support of a patient with fulminant hepatic failure. The first clinical case of XHDF is presented. The system consisted of cross-circulation between a porcine liver and a patient with fulminant liver failure through a polyacrylonitrile membrane. The procedure lasted for 5 hours and produced hemodynamic, biochemical, and metabolic improvements. Intracranial pressure decreased from 34 to 5 cm H2O, serum ammonia fell from 673 to 370 ng/dl, lactic acid from 11 to 5.3 mmol/L, and bilirubin from 7.4 to 2.5 mg/dl. Hemodynamic values were maintained stable throughout the procedure. The patient was able to undergo transplantation and remains alive 11 months later. XHDF is a clinical experimental method that can constitute an alternative clinical therapy to support patients with fulminant hepatic failure until an organ is available for transplantation.


Subject(s)
Hemofiltration , Liver Failure/therapy , Liver Transplantation , Acrylic Resins , Adult , Animals , Hemodynamics , Humans , Liver/pathology , Membranes, Artificial , Swine , Transplantation, Heterologous
SELECTION OF CITATIONS
SEARCH DETAIL
...