Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Liver Int ; 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38591767

ABSTRACT

BACKGROUND: The optimal cardiovascular assessment of liver transplant (LT) candidates is unclear. We aimed to evaluate the performance of CT-based coronary tests (coronary artery calcium score [CACS] and coronary CT angiography [CCTA]) and a modification of the CAD-LT score (mCAD-LT, excluding family history of CAD) to diagnose significant coronary artery disease (CAD) before LT and predict the incidence of post-LT cardiovascular events (CVE). METHODS: We retrospectively analysed a single-centre cohort of LT candidates who underwent non-invasive tests; invasive coronary angiography (ICA) was performed depending on the results of non-invasive tests. mCAD-LT was calculated in all patients. RESULTS: Six-hundred-and-thirty-four LT candidates were assessed and 351 of them underwent LT. CACS, CCTA and ICA were performed in 245, 123 and 120 LT candidates, respectively. Significant CAD was found in 30% of patients undergoing ICA. The AUROCs of mCAD-LT (.722) and CCTA (.654) were significantly higher than that of CACS (.502) to predict the presence of significant CAD. Specificity of the tests ranged between 31% for CCTA and 53% for CACS. Among patients who underwent LT, CACS ≥ 400 and mCAD-LT were independently associated with the incidence of CVE; in patients who underwent CCTA before LT, significant CAD at CCTA also predicted post-LT CVE. CONCLUSION: In this cohort, mCAD-LT score and CT-based tests detect the presence of significant CAD in LT candidates, although they tend to overestimate it. Both mCAD-LT score and CT-based tests classify LT recipients according to their risk of post-LT CVE and can be used to improve post-LT risk mitigation.

2.
HPB (Oxford) ; 25(4): 454-462, 2023 04.
Article in English | MEDLINE | ID: mdl-36759304

ABSTRACT

BACKGROUND: More than a half of patients undergoing liver transplantation (LT) receive intraoperative transfusion. Portal hypertension (PHT) may contribute to perioperative blood loss. We study the relationship between preoperative hepatic venous pressure gradient (HVPG) values and intraoperative transfusion requirements in adult patients undergoing LT. METHODS: 160 cirrhotic patients undergoing first elective LT (2009-2019) with an HVPG measurement within the previous 6 months were included. Surgical technique was piggyback with portocaval shunt (PCS). The association of HVPG and other variables with transfusion requirements and blood loss were studied. RESULTS: Blood loss (ml/kg) was positively correlated with HVPG, among other variables, but at multivariable analysis it only remained associated with MELD-Na and HCC indication. Regarding RBC transfusion, MELD-Na and hemoglobin were independently associated with the need and magnitude of RBC transfusion. Subanalysis by surgical stage (hepatectomy, anhepatic, neohepatic) and by serial HVPG cut-offs found no clear associations with either bleeding or transfusion. DISCUSSION: The severity of PHT plays a minor role on bleeding and transfusion during LT in a contemporary cohort with systematic PCS. Main determinants of transfusion are liver function and baseline hemoglobin, which would seem the suitable goal to optimize transfusion in LT.


Subject(s)
Carcinoma, Hepatocellular , Hypertension, Portal , Liver Neoplasms , Liver Transplantation , Adult , Humans , Liver Transplantation/adverse effects , Carcinoma, Hepatocellular/surgery , Liver Cirrhosis/complications , Liver Cirrhosis/surgery , Liver Neoplasms/surgery , Hypertension, Portal/diagnosis , Hypertension, Portal/etiology , Hypertension, Portal/surgery , Hemorrhage , Portal Pressure
3.
Dig Dis Sci ; 68(4): 1447-1454, 2023 04.
Article in English | MEDLINE | ID: mdl-36104534

ABSTRACT

BACKGROUND: Motorized Spiral Enteroscopy (MSE) reduces procedure time and increases insertion depth into the small bowel; however, there is scarce evidence on factors affecting MSE efficacy. AIMS: To evaluate diagnostic yield and adverse events of MSE including patients with prior major abdominal surgery. METHODS: A prospective observational study was conducted on patients undergoing MSE from June 2019 to December 2021. Demographic characteristics, procedure time, depth of maximum insertion (DMI), technical success, diagnostic yield, and adverse events were collected. RESULTS: Seventy-four anterograde (54.4%) and 62 retrograde (45.6%) enteroscopies were performed in 117 patients (64 males, median age 67 years). Fifty patients (42.7%) had prior major abdominal surgery. Technical success was 91.9% for anterograde and 90.3% for retrograde route. Diagnostic yield was 71.6% and 61.3%, respectively. The median DMI was 415 cm (264-585) for anterograde and 120 cm (37-225) for retrograde enteroscopy. In patients with prior major abdominal surgery, MSE showed significantly longer small bowel insertion time (38 vs 29 min, p = 0.004), with similar diagnostic yield (61 vs 71.4%, p = 0.201) and DMI (315 vs 204 cm, p = 0.226). The overall adverse event rate was 10.3% (SAE 1.5%), with no differences related to prior abdominal surgery (p = 0.598). Patients with prior surgeries directly involving the gastrointestinal tract showed lower DMI (189 vs 374 cm, p = 0.019) with equal exploration time (37.5 vs 38 min, p = 0.642) compared to those with other abdominal surgeries. CONCLUSIONS: MSE is effective and safe in patients with major abdominal surgery, although longer procedure times were observed. A lower depth of insertion was detected in patients with gastrointestinal surgery.


Subject(s)
Intestinal Diseases , Laparoscopy , Male , Humans , Aged , Intestinal Diseases/diagnosis , Endoscopy, Gastrointestinal/adverse effects , Endoscopy, Gastrointestinal/methods , Prospective Studies , Intestine, Small/surgery , Double-Balloon Enteroscopy/methods
4.
Resuscitation ; 81(4): 404-9, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20083335

ABSTRACT

AIM: The cardiac output and coronary perfusion pressure generated from chest compressions during resuscitation manoeuvres can predict effectiveness and successful outcome. Until now, there is no good method for haemodynamic monitoring during resuscitation. Noninvasive partial carbon dioxide rebreathing system (NICO, Novametrix Medical Systems, Inc., Wallingford, CT, USA) is a relatively new non-invasive alternative to thermodilution for measuring cardiac output. The accuracy of the NICO system has not been evaluated during resuscitation. The aim of this study is to compare thermodilution cardiac output method with NICO system and to assess the utility of NICO during resuscitation. METHODS AND DESIGN: Experimental study in 24 Yorkshire pigs. Paired measurements of cardiac output were determined during resuscitation (before ventricular fibrillation and after 5, 15, 30 and 45 min of resuscitation) in the supine position. The average of 3 consecutive thermodilution cardiac output measurements (10 ml 20 degrees C saline) was compared with the corresponding NICO measurement. RESULTS: Bland and Altman plot and Lin's concordance coefficient showed a high correlation between NICO and thermodilution cardiac output measurements although NICO has a tendency to underestimate cardiac output when compared to thermodilution at normal values of cardiac output. CONCLUSIONS: There is a high degree of agreement between cardiac output measurements obtained with NICO and thermodilution cardiac output during resuscitation. The present study suggests that the NICO system may be useful to measure cardiac output generated during cardiopulmonary resuscitation.


Subject(s)
Carbon Dioxide/metabolism , Cardiac Output/physiology , Monitoring, Physiologic/methods , Resuscitation , Animals , Swine , Thermodilution
5.
World J Gastroenterol ; 12(12): 1949-53, 2006 Mar 28.
Article in English | MEDLINE | ID: mdl-16610005

ABSTRACT

AIM: To characterize hyperlactatemia in patients with non-acetaminophen acute liver failure (ALF) in an attempt to clarify the mechanisms implicated and the role as a prognosis factor. METHODS: In the setting of liver transplantation, 63 consecutive patients with non-acetaminophen acute liver failure were studied in relation to tissue oxygenation, hemodynamic and metabolic parameters. Before and after transplantation, the number of infected patients and outcome were registered. RESULTS: Acute ALF showed higher levels of lactate than subacute ALF (5.4+/- 1 mmol/L versus 2.2+/- 0.6 mmol/L, P=0.01). Oxygenation parameters were within the normal range. Lactate levels showed good correlation with respiratory quotient (r=0.759, P< 0.005), mean glucose administration (r=0.664, P=0.01) and encephalopathy (r=0.698, P=0.02), but not with splanchnic arteriovenous difference in PCO2, pH and the presence of infection (P=0.1). Portal vein lactate was higher (P< 0.05) than arterial and mixed venous lactate, suggesting its production of hyperlactatemia in the intestine and spleen. The presence of infection was an independent predictor of survival. CONCLUSION: Hyperlactatemia is not a prognosis factor due to byproduct of the overall acceleration in glycolysis.


Subject(s)
Lactates/blood , Liver Failure, Acute/blood , Adult , Female , Glycolysis , Humans , Liver Failure, Acute/physiopathology , Liver Failure, Acute/surgery , Liver Transplantation , Male , Prognosis , Prospective Studies
6.
Anesth Analg ; 96(2): 475-80, table of contents, 2003 Feb.
Article in English | MEDLINE | ID: mdl-12538199

ABSTRACT

In cirrhotic patients undergoing hepatic surgery, postoperative analgesia remains a challenge. In this study, we evaluated the efficacy of a single dose of morphine combined with small-dose ketamine given epidurally for postoperative pain relief. One-hundred-four classification "Child A" cirrhotic patients were randomly assigned to two groups: 1) (MKG, n = 54): epidural morphine (3.5-5 mg) plus ketamine (20/30 mg); and 2) epidural morphine (3.5/5 mg) (MG, n = 50). The level of analgesia, side effects, psychomimetic and neurological disorders, additional analgesic needs, and overall quality of the analgesia were recorded. The mean duration of analgesia was longer in the MKG group (27.2 +/- 8 h versus 16.4 +/- 10 h; P < 0.05). In the MKG group, the visual analog scale (VAS) score began to be significantly lower from 14 h at rest and 12 h on coughing until the end of the study. The need for additional analgesia was also smaller in the MKG group (P < 0.05): at 24 h, only 10% of patients in the MKG group needed complementary analgesia, whereas in the MG group it was 100% (P = 0.003). Side effects were similar in both groups. Psychomimetic side effects and neurological disorders were not detected. These results suggest that postoperative analgesia provided by a single dose of epidural morphine with small-dose ketamine is effective in cirrhotic Child's A patients having major upper abdominal surgery.


Subject(s)
Acetaminophen/analogs & derivatives , Analgesia, Epidural , Analgesics, Opioid/therapeutic use , Anesthetics, Dissociative/therapeutic use , Ketamine/therapeutic use , Liver Cirrhosis/surgery , Liver/surgery , Morphine/therapeutic use , Pain, Postoperative/drug therapy , Acetaminophen/therapeutic use , Adult , Aged , Analgesics/therapeutic use , Analgesics, Opioid/administration & dosage , Analgesics, Opioid/adverse effects , Anesthetics, Dissociative/administration & dosage , Anesthetics, Dissociative/adverse effects , Carcinoma, Hepatocellular/complications , Carcinoma, Hepatocellular/surgery , Female , Humans , Ketamine/administration & dosage , Ketamine/adverse effects , Liver Cirrhosis/complications , Liver Function Tests , Liver Neoplasms/complications , Liver Neoplasms/surgery , Male , Methadone/therapeutic use , Middle Aged , Morphine/administration & dosage , Morphine/adverse effects , Pain Measurement , Patient Satisfaction , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...