Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Electromyogr Kinesiol ; 67: 102703, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36096034

ABSTRACT

PURPOSE: To establish intra- and inter-session reliability of high-density surface electromyography (HDEMG)-derived parameters from the thoracic erector spinae (ES) during static and dynamic goal-directed voluntary movements of the trunk, and during functional reaching tasks. METHODS: Twenty participants performed: 1) static trunk extension, 2) dynamic trunk forward and lateral flexion, and 3) multidirectional functional reaching tasks on two occasions separated by 7.5 ± 1.2 days. Muscle activity was recorded bilaterally from the thoracic ES. Root mean square (RMS), coordinates of the barycentre, mean frequency (MNF), and entropy were derived from the HDEMG signals. Reliability was determined with intraclass correlation coefficient (ICC), coefficient of variation, and standard error of measurement. RESULTS: Good-to-excellent intra-session reliability was found for all parameters and tasks (ICC: 0.79-0.99), whereas inter-session reliability varied across tasks. Static tasks demonstrated higher reliability in most parameters compared to functional and dynamic tasks. Absolute RMS and MNF showed the highest overall reliability across tasks (ICC: 0.66-0.98), while reliability of the barycentre was influenced by the direction of the movements. CONCLUSION: RMS and MNF derived from HDEMG show consistent inter-session reliability in goal-directed voluntary movements of the trunk and reaching tasks, whereas the measures of the barycentre and entropy demonstrate task-dependent reliability.


Subject(s)
Muscle Contraction , Muscle, Skeletal , Humans , Electromyography , Muscle Contraction/physiology , Reproducibility of Results , Muscle, Skeletal/physiology , Paraspinal Muscles , Movement/physiology
2.
J Electromyogr Kinesiol ; 57: 102533, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33621756

ABSTRACT

Precision of trunk movement has commonly been examined by testing relocation accuracy rather than evaluating accuracy of tracking dynamic movement. In this study we used a 3-D motion capture system to provide a novel real-time tracking task to assess trunk motor control at varying movement speeds between people with and without chronic non-specific low back pain (LBP). Eleven asymptomatic volunteers and 15 participants with chronic non-specific LBP performed 12 continuous cycles of trunk flexion-extension following real time visual feedback, during which, trunk motion was measured using eight optoelectronic infrared cameras. Significant time differences between the feedback and actual trunk motion were found between groups (P = 0.001). Both groups had similar variability of tracking accuracy when following the feedback (P > 0.05). However, tracking variability at a slow speed correlated (P = 0.03; r = 0.55) with the Fear-Avoidance Beliefs Questionnaire (FABQ) scores in those with LBP. This study shows that both asymptomatic people and individuals with LBP displayed anticipatory behaviour, however, the response of those with LBP was consistently delayed in tracking the visual feedback compared to the asymptomatic group. Additionally, the extent of variability of tracking accuracy over repeated tracking cycles was associated with the degree of fear of movement in people with LBP.


Subject(s)
Biomechanical Phenomena/physiology , Computer Systems , Electromyography/methods , Low Back Pain/physiopathology , Movement/physiology , Torso/physiology , Adolescent , Adult , Cross-Sectional Studies , Fear/physiology , Fear/psychology , Female , Humans , Low Back Pain/psychology , Male , Middle Aged , Muscle, Skeletal/physiology , Surveys and Questionnaires , Young Adult
3.
Exp Brain Res ; 236(5): 1471-1478, 2018 05.
Article in English | MEDLINE | ID: mdl-29549403

ABSTRACT

Sensory information conveyed along afferent fibers from muscle and joint proprioceptors play an important role in the control of posture and gait in humans. In particular, proprioceptive information from the neck is fundamental in supplying the central nervous system with information about the orientation and movement of the head relative to the rest of the body. The previous studies have confirmed that proprioceptive afferences originating from the neck region, evoked via muscle vibration, lead to strong body-orienting effects during static conditions (e.g., leaning of the body forwards or backwards, depending on location of vibration). However, it is not yet certain in humans, whether the somatosensory receptors located in the deep skin (cutaneous mechanoreceptors) have a substantive contribution to postural control, as vibratory stimulation encompasses the receptive field of all the somatosensory receptors from the skin to the muscles. The aim of this study was to investigate the postural effect of cutaneous mechanoreceptor afferences using electro-tactile stimulation applied to the neck. Ten healthy volunteers (8M, 2F) were evaluated. The average position of their centre of foot pressure (CoP) was acquired before, during, and after a subtle electro-tactile stimulation over their posterior neck (mean ± SD = 5.1 ± 2.3 mA at 100 Hz-140% of the perception threshold) during upright stance with their eyes closed. The electro-tactile stimulation led to a body-orienting effect with the subjects consistently leaning forward. An average shift of the CoP of 12.1 ± 11.9 mm (mean ± SD) was reported, which significantly (p < 0.05) differed from its average position under a control condition (no stimulation). These results indicate that cutaneous mechanoreceptive inflow from the neck is integrated to control stance. The findings are relevant for the exploitation of electro-tactile stimulation for rehabilitation interventions where induced anteropulsion of the body is desired.


Subject(s)
Neck/physiology , Postural Balance/physiology , Posture/physiology , Proprioception/physiology , Touch/physiology , Adult , Electric Stimulation , Female , Humans , Male , Physical Stimulation , Young Adult
4.
J Physiol ; 595(5): 1479-1496, 2017 03 01.
Article in English | MEDLINE | ID: mdl-28032343

ABSTRACT

KEY POINTS: Classic motor unit (MU) recording and analysis methods do not allow the same MUs to be tracked across different experimental sessions, and therefore, there is limited experimental evidence on the adjustments in MU properties following training or during the progression of neuromuscular disorders. We propose a new processing method to track the same MUs across experimental sessions (separated by weeks) by using high-density surface electromyography. The application of the proposed method in two experiments showed that individual MUs can be identified reliably in measurements separated by weeks and that changes in properties of the tracked MUs across experimental sessions can be identified with high sensitivity. These results indicate that the behaviour and properties of the same MUs can be monitored across multiple testing sessions. The proposed method opens new possibilities in the understanding of adjustments in motor unit properties due to training interventions or the progression of pathologies. ABSTRACT: A new method is proposed for tracking individual motor units (MUs) across multiple experimental sessions on different days. The technique is based on a novel decomposition approach for high-density surface electromyography and was tested with two experimental studies for reliability and sensitivity. Experiment I (reliability): ten participants performed isometric knee extensions at 10, 30, 50 and 70% of their maximum voluntary contraction (MVC) force in three sessions, each separated by 1 week. Experiment II (sensitivity): seven participants performed 2 weeks of endurance training (cycling) and were tested pre-post intervention during isometric knee extensions at 10 and 30% MVC. The reliability (Experiment I) and sensitivity (Experiment II) of the measured MU properties were compared for the MUs tracked across sessions, with respect to all MUs identified in each session. In Experiment I, on average 38.3% and 40.1% of the identified MUs could be tracked across two sessions (1 and 2 weeks apart), for the vastus medialis and vastus lateralis, respectively. Moreover, the properties of the tracked MUs were more reliable across sessions than those of the full set of identified MUs (intra-class correlation coefficients ranged between 0.63-0.99 and 0.39-0.95, respectively). In Experiment II, ∼40% of the MUs could be tracked before and after the training intervention and training-induced changes in MU conduction velocity had an effect size of 2.1 (tracked MUs) and 1.5 (group of all identified motor units). These results show the possibility of monitoring MU properties longitudinally to document the effect of interventions or the progression of neuromuscular disorders.


Subject(s)
Exercise/physiology , Motor Neurons/physiology , Action Potentials , Adult , Electromyography , Humans , Isometric Contraction , Knee/physiology , Male , Physical Endurance/physiology , Quadriceps Muscle/physiology , Young Adult
5.
Clin Neurophysiol ; 127(6): 2534-41, 2016 06.
Article in English | MEDLINE | ID: mdl-26778718

ABSTRACT

OBJECTIVE: To assess the intra- and inter-session reliability of estimates of motor unit behavior and muscle fiber properties derived from high-density surface electromyography (HDEMG). METHODS: Ten healthy subjects performed submaximal isometric knee extensions during three recording sessions (separate days) at 10%, 30%, 50% and 70% of their maximum voluntary effort. The discharge timings of motor units of the vastus lateralis and medialis muscles were automatically identified from HDEMG by a decomposition algorithm. We characterized the number of detected motor units, their discharge rates, the coefficient of variation of their inter-spike intervals (CoVisi), the action potential conduction velocity and peak-to-peak amplitude. Reliability was assessed for each motor unit characteristics by intra-class correlation coefficient (ICC). Additionally, a pulse-to-noise ratio (PNR) was calculated, to verify the accuracy of the decomposition. RESULTS: Good to excellent reliability within and between sessions was found for all motor unit characteristics at all force levels (ICCs>0.8), with the exception of CoVisi that presented poor reliability (ICC<0.6). PNR was high and similar for both muscles with values ranging between 45.1 and 47.6dB (accuracy>95%). CONCLUSION: Motor unit features can be assessed non-invasively and reliably within and across sessions over a wide range of force levels. SIGNIFICANCE: These results suggest that it is possible to characterize motor units in longitudinal intervention studies.


Subject(s)
Electromyography/methods , Quadriceps Muscle/physiology , Adult , Electromyography/standards , Evoked Potentials, Motor , Humans , Knee/innervation , Knee/physiology , Male , Quadriceps Muscle/innervation , Signal-To-Noise Ratio
6.
Scand J Med Sci Sports ; 26(11): 1273-1282, 2016 Nov.
Article in English | MEDLINE | ID: mdl-26493490

ABSTRACT

We studied the sensitivity of electromyographic (EMG) variables to load and muscle fatigue during continuous and intermittent incremental cycling. Fifteen men attended three laboratory sessions. Visit 1: lactate threshold, peak power output, and VO2max . Visits 2 and 3: Continuous (more fatiguing) and intermittent (less fatiguing) incremental cycling protocols [20%, 40%, 60%, 80% and 100% of peak power output (PPO)]. During both protocols, multichannel EMG signals were recorded from vastus lateralis: muscle fiber conduction velocity (MFCV), instantaneous mean frequency (iMNF), and absolute and normalized root mean square (RMS) were analyzed. MFCV differed between protocols (P < 0.001), and only increased consistently with power output during intermittent cycling. RMS parameters were similar between protocols, and increased linearly with power output. However, only normalized RMS was higher during the more fatiguing 100% PPO stage of the continuous protocol [continuous-intermittent mean difference (95% CI): 45.1 (8.5% to 81.7%)]. On the contrary, iMNF was insensitive to load changes and muscle fatigue (P = 0.14). Despite similar power outputs, continuous and intermittent cycling influenced MFCV and normalized RMS differently. Only normalized RMS was sensitive to both increases in power output (in both protocols) and muscle fatigue, and thus is the most suitable EMG parameter to monitor changes in muscle activation during cycling.


Subject(s)
Bicycling/physiology , Electromyography , Muscle Fatigue/physiology , Muscle Fibers, Skeletal/physiology , Quadriceps Muscle/physiology , Adolescent , Adult , Humans , Male , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...