Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 231
Filter
1.
J Neural Transm (Vienna) ; 129(4): 387-394, 2022 04.
Article in English | MEDLINE | ID: mdl-35306617

ABSTRACT

Locus Coeruleus (LC) is the main noradrenergic nucleus of the brain, which is involved in many physiological functions including cognition; its impairment may be crucial in the neurobiology of a variety of brain diseases. Locus Coeruleus-Magnetic Resonance Imaging (LC-MRI) allows to identify in vivo LC in humans. Thus, a variety of research teams have been using LC-MRI to estimate LC integrity in normal aging and in patients affected by neurodegenerative disorders, where LC integrity my work as a biomarker. A number of variations between LC-MRI studies exist, concerning post-acquisition analysis and whether this had been performed within MRI native space or in ad hoc-built MRI template space. Moreover, the reproducibility and reliability of this tool is still to be explored. Therefore, in the present study, we analyzed a group of neurologically healthy, cognitively intact elderly subjects, using both a native space- and a template space-based LC-MRI analysis. We found a good inter-method agreement, particularly considering the LC Contrast Ratio. The template space-based approach provided a higher spatial resolution, lower operator-dependency, and allowed the analysis of LC topography. Our ad hoc-developed LC template showed LC morphological data that were in line with templates published very recently. Remarkably, present data significantly overlapped with a recently published LC "metaMask", that had been obtained by averaging the results of a variety of previous LC-MRI studies. Thus, such a template space-based approach may pave the way to a standardized LC-MRI analysis and to be used in future clinic-anatomical correlations.


Subject(s)
Locus Coeruleus , Magnetic Resonance Imaging , Aged , Aging , Humans , Locus Coeruleus/diagnostic imaging , Magnetic Resonance Imaging/methods , Magnetic Resonance Spectroscopy , Reproducibility of Results
2.
J Neuromuscul Dis ; 7(4): 505-510, 2020.
Article in English | MEDLINE | ID: mdl-32538861

ABSTRACT

Hereditary neuropathy with liability to pressure palsies (HNPP) is an autosomal dominant inherited disorder commonly presenting with acute-onset, non-painful focal sensory and motor mono neuropathy. In 80% of cases, the genetic defect is a 1.5 Mb deletion on chromosome 17p11.2, including PMP22. Only few cases of partial deletion and point mutations in PMP22 are involved in HNPP. We investigated a 62-years-old man with lower limb plexopathy first considered as Garland's syndrome. A month later, his 29 years old son also consulted for paresthesia on the peroneal nerve.Targeted sequencing of the PMP22 gene identified a c.370delT (p.Trp124Glyfs*31) in both affected patients.We report a new PMP22 point mutation associated with an atypical clinical phenotype of HNPP, a painful plexopathy of the lower limb worsenen by diabetes and a mere paresthesia, but a typical ENMG. This study illustrates the large spectrum of the disease, and emphasizes the importance of a complete ENMG and family history.


Subject(s)
Arthrogryposis/genetics , Arthrogryposis/physiopathology , Hereditary Sensory and Motor Neuropathy/genetics , Hereditary Sensory and Motor Neuropathy/physiopathology , Myelin Proteins/genetics , Adult , Arthrogryposis/diagnosis , Hereditary Sensory and Motor Neuropathy/diagnosis , Humans , Male , Middle Aged , Pedigree , Phenotype , Point Mutation
4.
Vox Sang ; 2018 Jul 03.
Article in English | MEDLINE | ID: mdl-29971786

ABSTRACT

BACKGROUND AND OBJECTIVES: During storage, red blood cells (RBCs) undergo physicochemical changes which affect the quality, function, and in vivo survival of transfused packed RBCs (pRBC). Changes include decreased 2,3-diphosphoglycerate (2,3-DPG) levels, decreased ATP, changes in mechanical properties and oxidative injury. RBC rejuvenation is a method used to increase levels of 2,3-DPG and ATP in pRBCs. This process requires incubating the pRBCs with a rejuvenation solution and subsequent washing. Standard blood bank protocols using the COBE 2991 Cell Processor require several hours of preparation. The objective of this study was to verify if a bedside protocol for rejuvenating pRBC and washing with the Sorin Xtra autologous cell salvage system could be used. MATERIALS AND METHODS: Outdated pRBC units were obtained and rejuvenated in a model operating suite using a dry air incubator for 1 h at 37°C. Six units of pRBCs were pre-diluted with saline (1000 ml) and six units were not pre-diluted with saline. All units were washed with normal saline (1000 ml) using an apheresis-design cell salvage device in manual mode and wash volume set to 3000 ml. Samples were collected and analyzed for standard RBC quality parameters at baseline and post-wash. RESULTS: Total pRBC wash efficiency was 94% ± 12% at a final hematocrit of 67.7 ± 5.9% while maintaining post-wash hemolysis 0.24 ± 0.12 %. Pre-dilution prior to washing did not confer statistically significant differences in final RBC quality parameters with the notable exceptions of calculated hemolysis and supernatant potassium levels (P < 0.05). The washing process can be completed within 10 min. The post-wash RBC parameters are appropriate for immediate transfusion to patients.

5.
Phys Med Biol ; 62(19): 7741-7764, 2017 Sep 15.
Article in English | MEDLINE | ID: mdl-28777746

ABSTRACT

Calcifications are products of mineralization whose presence is usually associated with pathological conditions. The minerals mostly seen in several diseases are calcium oxalate (CaC2O4), calcium carbonate (CaCO3) and hydroxyapatite (HAp). Up to date, there is no in vivo method that could discriminate between minerals. To this aim, a dual energy x-ray method was developed in the present study. An analytical model was implemented for the determination of the Calcium/Phosphorus mass ratio ([Formula: see text]). The simulation was carried out using monoenergetic and polyenergetic x-rays and various calcification thicknesses (100-1000 [Formula: see text]) and types (CaC2O4, CaCO3, HAp). The experimental evaluation of the method was performed using the optimized irradiation conditions obtained from the simulation study. X-ray tubes, combined with energy dispersive and energy integrating (imaging) detectors, were used for the determination of the [Formula: see text] in phantoms of different mineral types and thicknesses. Based on the results of the experimental procedure, statistical significant difference was observed between the different types of minerals when calcification thicknesses were 300 [Formula: see text] or higher.


Subject(s)
Absorptiometry, Photon/methods , Breast Diseases/diagnostic imaging , Calcinosis/diagnostic imaging , Phantoms, Imaging , Breast Diseases/pathology , Calcinosis/pathology , Calcium Carbonate , Durapatite , Female , Humans , X-Rays
6.
Biomaterials ; 129: 176-187, 2017 06.
Article in English | MEDLINE | ID: mdl-28343004

ABSTRACT

Stable interconnection to neurons in vivo over long time-periods is critical for the success of future advanced neuroelectronic applications. The inevitable foreign body reaction towards implanted materials challenges the stability and an active intervention strategy would be desirable to treat inflammation locally. Here, we investigate whether controlled release of the anti-inflammatory drug Dexamethasone from flexible neural microelectrodes in the rat hippocampus has an impact on probe-tissue integration over 12 weeks of implantation. The drug was stored in a conducting polymer coating (PEDOT/Dex), selectively deposited on the electrode sites of neural probes, and released on weekly basis by applying a cyclic voltammetry signal in three electrode configuration in fully awake animals. Dex-functionalized probes provided stable recordings and impedance characteristics over the entire chronic study. Histological evaluation after 12 weeks of implantation revealed an overall low degree of inflammation around all flexible probes whereas electrodes exposed to active drug release protocols did have neurons closer to the electrode sites compared to controls. The combination of flexible probe technology with anti-inflammatory coatings accordingly offers a promising approach for enabling long-term stable neural interfaces.


Subject(s)
Dexamethasone/pharmacology , Microelectrodes , Neurons/physiology , Action Potentials/drug effects , Animals , Bridged Bicyclo Compounds, Heterocyclic/chemistry , Delayed-Action Preparations/pharmacology , Dielectric Spectroscopy , Drug Liberation , Electrochemical Techniques , Female , Fluorescence , Glial Fibrillary Acidic Protein/metabolism , Microglia/metabolism , Neurons/drug effects , Polymers/chemistry , Rats, Sprague-Dawley
7.
Appl Radiat Isot ; 118: 18-24, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27571965

ABSTRACT

An X-ray dual energy (XRDE) method was examined, using polynomial nonlinear approximation of inverse functions for the determination of the bone Calcium-to-Phosphorus (Ca/P) mass ratio. Inverse fitting functions with the least-squares estimation were used, to determine calcium and phosphate thicknesses. The method was verified by measuring test bone phantoms with a dedicated dual energy system and compared with previously published dual energy data. The accuracy in the determination of the calcium and phosphate thicknesses improved with the polynomial nonlinear inverse function method, introduced in this work, (ranged from 1.4% to 6.2%), compared to the corresponding linear inverse function method (ranged from 1.4% to 19.5%).


Subject(s)
Absorptiometry, Photon/methods , Algorithms , Bone and Bones/chemistry , Calcium/analysis , Phosphorus/analysis , Radiographic Image Interpretation, Computer-Assisted/methods , Computer Simulation , Humans , Models, Statistical , Numerical Analysis, Computer-Assisted , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
8.
Comput Math Methods Med ; 2015: 574238, 2015.
Article in English | MEDLINE | ID: mdl-26246848

ABSTRACT

Dual energy methods can suppress the contrast between adipose and glandular tissues in the breast and therefore enhance the visibility of calcifications. In this study, a dual energy method based on analytical modeling was developed for the detection of minimum microcalcification thickness. To this aim, a modified radiographic X-ray unit was considered, in order to overcome the limited kVp range of mammographic units used in previous DE studies, combined with a high resolution CMOS sensor (pixel size of 22.5 µm) for improved resolution. Various filter materials were examined based on their K-absorption edge. Hydroxyapatite (HAp) was used to simulate microcalcifications. The contrast to noise ratio (CNR tc ) of the subtracted images was calculated for both monoenergetic and polyenergetic X-ray beams. The optimum monoenergetic pair was 23/58 keV for the low and high energy, respectively, resulting in a minimum detectable microcalcification thickness of 100 µm. In the polyenergetic X-ray study, the optimal spectral combination was 40/70 kVp filtered with 100 µm cadmium and 1000 µm copper, respectively. In this case, the minimum detectable microcalcification thickness was 150 µm. The proposed dual energy method provides improved microcalcification detectability in breast imaging with mean glandular dose values within acceptable levels.


Subject(s)
Breast/pathology , Mammography/methods , Adipose Tissue/pathology , Algorithms , Breast Density , Breast Neoplasms , Calcinosis , Computer Simulation , Durapatite/chemistry , Female , Humans , Mammary Glands, Human/abnormalities , Phantoms, Imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Signal-To-Noise Ratio , X-Rays
9.
Phys Med ; 31(3): 307-13, 2015 May.
Article in English | MEDLINE | ID: mdl-25726476

ABSTRACT

Non-invasive dual energy methods have been used extensively on osteoporosis diagnosis estimating parameters, such as, Bone Mineral Density (BMD) and Bone Mineral Content (BMC). In this study, an X-ray dual energy method (XRDE) was developed for the estimation of the bone Calcium-to-Phosphorous (Ca/P) mass ratio, as a bone quality index. The optimized irradiation parameters were assessed by performing analytical model simulations. X-ray tube output, filter material and thickness were used as input parameters. A single exposure technique, combined with K-edge filtering, was applied. The optimal X-ray spectra were selected according to the resulted precision and accuracy values. Experimental evaluation was performed on an XRDE system incorporating a Cadmium Telluride (CdTe) photon counting detector and three bone phantoms with different nominal mass Ca/P ratios. Additionally, the phantoms' mass Ca/P ratios were validated with energy-dispersive X-ray spectroscopy (EDX). Simulation results showed that the optimum filter atomic number (Z) ranges between 57 and 70. The optimum spectrum was obtained at 100 kVp, filtered with Cerium (Ce), with a surface density of 0.88 g/cm(2). All Ca/P ratio measurements were found to be accurate to within 1.6% of the nominal values, while the precision ranged between 0.91 and 1.37%. The accuracy and precision values of the proposed non-invasive method contributes to the assessment of the bone quality state through the mass Ca/P ratio determination.


Subject(s)
Absorptiometry, Photon , Bone and Bones/metabolism , Calcium/metabolism , Phosphorus/metabolism , Bone Density , Bone and Bones/physiology , Cadmium Compounds , Humans , Osteoporosis/diagnosis , Phantoms, Imaging , Tellurium
10.
Curr Pharm Des ; 20(39): 6171-81, 2014.
Article in English | MEDLINE | ID: mdl-24745919

ABSTRACT

Cardiac health depends on the heart's ability to utilize different substrates to support overall oxidative metabolism. To characterize a variety of cardiac diseases, there is an ever-growing demand for an accurate non-invasive approach to evaluating myocardial substrate metabolism. Data obtained from quantitative metabolic imaging modalities add functional information to the anatomic imaging modalities and can aid patient management. The goal of this review is to emphasize the role of non-invasive imaging techniques (such as PET, SPECT, MR spectroscopy and spectroscopic imaging) to detect the metabolic footprints of heart disease. The advancements of models and methods to estimate kinetic parameters of dynamic processes using data acquired from cardiac imaging modalities is discussed.


Subject(s)
Cardiovascular Diseases/metabolism , Myocardium/metabolism , Humans , Magnetic Resonance Imaging , Models, Molecular , Positron-Emission Tomography , Radiopharmaceuticals/metabolism , Tomography, Emission-Computed, Single-Photon
11.
Med Phys ; 39(3): 1561-70, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22380388

ABSTRACT

PURPOSE: To evaluate modulation transfer function (MTF) in single photon emission computed tomography (SPECT) systems using the line spread function (LSF) method and a novel flood source which can be easily fabricated with materials accessible in hospital facilities. METHODS: A Tc-99m-based flood source (E(γ) = 140 keV) consisting of a radiopharmaceutical bound to the grains of a radiographic film was prepared in laboratory. Various films and radiopharmaceuticals were examined, in order to obtain a thin homogenous and reproducible flood source. The source showing best uniformity and reproducibility was placed between two PMMA blocks and images were obtained by using the brain tomographic acquisition protocol (brain) and the myocardial perfusion tomographic acquisition protocol (heart). MTF was evaluated by determining the LSF for various reconstruction methods and filters. MTF calculation was obtained by the utilization of a custom made software in which a method similar to the one proposed by Boone [Med. Phys. 28, 356-360 (2001)] was implemented. All imaging experiments were performed in a Siemens e-Cam γ-camera. Furthermore, MTF was assessed through the point spread function (PSF) following conventional methods. RESULTS: The optimum homogeneity was obtained by immersing an Agfa MammoRay HDR Medical x-ray film in a solution of dithiothreitol (DTT, 10(-3) M)/Tc-99m(III)-DMSA (DMSA: trivalent technetium-99m-dimercapto-succinic acid, 40 mCi/40 ml) for 30 min in the dark. These films exhibited better uniformity (CV < 1.9%). Higher MTF values were obtained for the brain scan protocol with iterative 3D with eight iterations reconstruction method. MTF of the brain protocol was in all cases better than the heart protocol. MTFs derived from LSF were more precise compared with those obtained from PSF since their reproducibility was better in all cases, providing a mean standard deviation of 0.0065, in contrary to the PSF method which gave 0.0348. CONCLUSIONS: The method presented here is novel and easy to implement, requiring materials commonly found in clinical practice. Furthermore, this technique which is based on the LSF method reduces measurement noise levels due to the larger amount of data averaging than in the conventional PSF method. Furthermore, MTF can be assessed easily, in three dimensions (3D), by placing the flood source either in sagittal or coronal direction.


Subject(s)
Phantoms, Imaging , Tomography, Emission-Computed, Single-Photon/instrumentation , Brain/diagnostic imaging , Heart/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Radiopharmaceuticals
13.
Br J Radiol ; 83(985): e1-4, 2010 Jan.
Article in English | MEDLINE | ID: mdl-20139247

ABSTRACT

We report the case of a 42-year-old woman being treated for an ovarian cancer who was diagnosed at the age of 40. A CT-positron emission tomography (PET) scan performed as follow-up documented abnormal uptake in the right breast. Mammograms were negative for malignancy, while a focal hyperechoic lesion was observed on ultrasonography in the same breast. Thus, she was referred to our institution for breast MRI, which showed a focal area of enhancement with atypical features. Percutaneous biopsy was performed, and a mammary hibernoma was diagnosed. Radiological and pathological correlation was provided. To our knowledge, this is the only report that describes the features of this rare tumour on four different imaging modalities (mammography, ultrasonography, MRI and CT-PET).


Subject(s)
Breast Neoplasms/diagnosis , Lipoma/diagnosis , Adult , Diagnosis, Differential , Female , Humans , Magnetic Resonance Imaging/methods , Mammography , Positron-Emission Tomography/methods , Ultrasonography, Mammary
14.
NMR Biomed ; 23(1): 66-73, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19708042

ABSTRACT

The acquisition of magnetic resonance spectroscopy (MRS) signals by multiple receiver coils can improve the signal-to-noise ratio (SNR) or alternatively can reduce the scan time maintaining a reliable SNR. However, using phased array coils in MRS studies requires efficient data processing and data combination techniques in order to exploit the sensitivity improvement of the phased array coil acquisition method. This paper describes a novel method for the combination of MRS signals acquired by phased array coils, even in presence of correlated noise between the acquisition channels. In fact, although it has been shown that electric and magnetic coupling mechanisms produce correlated noise in the coils, previous algorithms developed for MRS data combination have ignored this effect. The proposed approach takes advantage of a noise decorrelation stage to maximize the SNR of the combined spectra. In particular Principal Component Analysis (PCA) was exploited to project the acquired spectra in a subspace where the noise vectors are orthogonal. In this subspace the SNR weighting method will provide the optimal overall SNR. Performance evaluation of the proposed method is carried out on simulated (1)H-MRS signals and experimental results are obtained on phantom (1)H-MR spectra using a commercially available 8-element phased array coil. Noise correlations between elements were generally low due to the optimal coil design, leading to a fair SNR gain (about 0.5%) in the center of the field of view (FOV). A greater SNR improvement was found in the peripheral FOV regions.


Subject(s)
Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Spectroscopy/methods , Algorithms , Magnetic Resonance Spectroscopy/instrumentation , Models, Theoretical , Principal Component Analysis
15.
Physiol Meas ; 30(8): 779-94, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19550025

ABSTRACT

This paper presents a novel method to objectively select electroencephalographic (EEG) cortical sources estimated by independent component analysis (ICA) in event-related potential (ERP) studies. A proximity measure based on mutual information is employed to estimate residual dependences of the components that are then hierarchically clustered based on these residual dependences. Next, the properties of each group of components are evaluated at each level of the hierarchical tree by two indices that aim to assess both cluster tightness and physiological reliability through a template matching process. These two indices are combined in three different approaches to bring to light the hierarchical structure of the cluster organizations. Our method is tested on a set of experiments with the purpose of enhancing late positive ERPs elicited by emotional picture stimuli. Results suggest that the best way to look for physiologically plausible late positive potential (LPP) sources is to explore in depth the tightness of those clusters that, taken together, best resemble the template. According to our results, after brain sources clustering, LPPs are always identified more accurately than from ensemble-averaged raw data. Since the late components of an ERP involve the same associative areas, regardless of the modality of stimulation or specific tasks administered, the proposed method can be simply adapted to other ERP studies, and extended from psychophysiological studies to pathological or sport training evaluation support.


Subject(s)
Algorithms , Electroencephalography/methods , Evoked Potentials , Signal Processing, Computer-Assisted , Adolescent , Adult , Humans , Male , Time Factors , Young Adult
17.
Med Biol Eng Comput ; 46(3): 251-61, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18064502

ABSTRACT

Electrocardiographic (ECG) signals are affected by several kinds of artifacts that may hide vital signs of interest. In this study we apply independent component analysis (ICA) to isolate motion artifacts. Standard or instantaneous ICA, which is currently the most addressed ICA model within the context of artifact removal, is compared to two other ICA techniques. The first technique is a frequency domain approach to convolutive mixture separation. The second is based on temporally constrained ICA, which enables the estimation of only one component close to a particular reference signal. Performance indexes evaluate ECG complex enhancement and relevant heart rate errors. Our results show that both convolutive and constrained ICA implementations perform better than standard ICA, thus opening up a new field of application for these two methods. Moreover, statistical analysis reveals that constrained ICA and convolutive ICA do not significantly differ concerning heart rate estimation, even though the latter overcomes the former in ECG morphology recovery.


Subject(s)
Artifacts , Electrocardiography/methods , Signal Processing, Computer-Assisted , Data Interpretation, Statistical , Humans , Motion , Principal Component Analysis
18.
Clin Genet ; 70(1): 57-62, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16813605

ABSTRACT

Mutations in ATRX are associated with a wide and clinically heterogeneous spectrum of X-linked mental retardation syndromes. The ATRX protein, involved in chromatin remodelling, belongs to the family of SWI/SNF DNA helicases and contains a plant homeodomain (PHD)-like domain. To date, more than 60 different mutations have been reported in ATRX. One of them is recurrent and accounts for 20% of all the reported mutations, whereas all others are private. Most mutations are clustered in the two major functional domains, the helicase and the PHD-like domain. So far, no clear genotype-phenotype correlation has been established, with exception to the rare truncating mutations located at the C-terminal part of the protein, which are consistently associated with severe urogenital defects. In this study, we report the molecular analysis performed in 16 families positive for ATRX. Our findings indicate that, in addition to the previously described mutation 'hotspot' in the PHD-like domain, two other protein sections emerge as minor 'hotspots' in the helicase region encoded by exons 18-20 and 26-29, respectively, gathering 33% of all described mutations. Additionally, based on the clinical data collected for 22 patients from the 16 families, we observe that mutations in the PHD-like domain produce severe and permanent psychomotor deficiency, usually preventing patients from walking, as well as constant urogenital abnormalities, while mutations in the helicase domain lead to delayed but correct psychomotor acquisitions together with mild or absent urogenital abnormalities. In summary, mutations in the helicase domain are associated with milder phenotypes than mutations in the PHD-like domain.


Subject(s)
DNA Helicases/chemistry , DNA Helicases/genetics , Mutation , Nuclear Proteins/chemistry , Nuclear Proteins/genetics , Psychomotor Disorders/enzymology , Psychomotor Disorders/genetics , Urogenital Abnormalities/enzymology , Urogenital Abnormalities/genetics , DNA, Complementary/genetics , Female , Humans , Intellectual Disability/enzymology , Intellectual Disability/genetics , Male , Mothers , Phenotype , Protein Structure, Tertiary , Syndrome , X Chromosome Inactivation , X-linked Nuclear Protein , alpha-Thalassemia/enzymology , alpha-Thalassemia/genetics
19.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 3391-4, 2006.
Article in English | MEDLINE | ID: mdl-17946178

ABSTRACT

Electrocardiographic (ECG) signals are affected by several kinds of artifacts, that may hide vital signs of interest. Motion artifacts, due to the motion of the electrodes in relation to patient skin, are particularly frequent in bioelectrical signals acquired by wearable systems. In this paper we propose different approaches in order to get rid of motion confounds. The first approach we follow starts from measuring electrode motion provided by an accelerometer placed on the electrode and use this measurement in an adaptive filtering system to remove the noise present in the ECG. The second approach is based on independent component analysis methods applied to multichannel ECG recordings; we propose to use both instantaneous model and a frequency domain implementation of the convolutive model that accounts for different paths of the source signals to the electrodes.


Subject(s)
Electrocardiography/statistics & numerical data , Algorithms , Biomedical Engineering , Electrodes , Humans , Models, Statistical , Motion , Signal Processing, Computer-Assisted
20.
J Ethnopharmacol ; 93(2-3): 207-12, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15234754

ABSTRACT

Preliminary studies with Combretum erythrophyllum showed antimicrobial activity against Gram-positive and Gram-negative bacteria. Seven antibacterial flavonoids were subsequently isolated by bioassay-guided fractionation, i.e. apigenin; genkwanin; 5-hydroxy-7,4'-dimethoxyflavone, rhamnocitrin; kaempferol; quercetin-5,3'-dimethylether; rhamnazin. All compounds had good activity against Vibrio cholerae and Enterococcus faecalis, with MIC values in the range of 25-50 microg/ml. Rhamnocitrin and quercetin-5,3'-dimethylether also inhibited Micrococcus luteus and Shigella sonei at 25 microg/ml. With the exception of 5-hydroxy-7,4'-dimethoxy-flavone the flavonoids were not toxic towards human lymphocytes. This compound is potentially toxic to human cells and exhibited the poorest antioxidant activity whereas rhamnocitrin and rhamnazin exhibited strong antioxidant activity. Genkwanin; rhamnocitrin; quercetin-5,3'-dimethylether; rhamnazin had a higher anti-inflammatory activity than the positive control mefenamic acid. Although these flavonoids are known, this is the first report of biological activity with several of these compounds.


Subject(s)
Anti-Bacterial Agents/pharmacology , Combretum , Gram-Negative Bacteria/drug effects , Gram-Positive Bacteria/drug effects , Phytotherapy , Plant Extracts/pharmacology , Anti-Bacterial Agents/administration & dosage , Anti-Bacterial Agents/therapeutic use , Aspergillus niger/drug effects , Flavonoids/administration & dosage , Flavonoids/pharmacology , Flavonoids/therapeutic use , Humans , Microbial Sensitivity Tests , Plant Extracts/administration & dosage , Plant Extracts/therapeutic use , Plant Leaves
SELECTION OF CITATIONS
SEARCH DETAIL
...