Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Publication year range
1.
Article in Japanese | WPRIM (Western Pacific) | ID: wpr-1040095

ABSTRACT

We present the case of a 72-year-old male with Inspiris RESILIA aortic valve (Inspiris) transvalvular leakage during surgical aortic valve replacement (AVR). The patient initially underwent AVR for aortic regurgitation with a bicuspid aortic valve at the age of 64. By the age of 72, the valve had deteriorated and it was assessed that redoing the AVR was necessary. The Inspiris was inserted in the supra-annular position using the non-everting mattress suture technique with a COR-KNOT. During weaning off from cardiopulmonary bypass, transesophageal echocardiography (TEE) captured unfamiliar turbulent flows from the three stent posts. Further TEE revealed that these flows originated from the base of the stent posts, which gradually decreased and disappeared by the end of the surgery after administration of protamine. The patient has been discharged uneventfully. Paravalvular leakage has not been observed during the postoperative course and we could not find TVL in TEE 2 months postoperatively. While considering the detailed mechanism, it is possible that there is no need for re-exploration concerning three directional TVL in the Inspiris.

2.
Article in Japanese | WPRIM (Western Pacific) | ID: wpr-1040187

ABSTRACT

A 65-year-old male was diagnosed with severe aortic stenosis with an indication for surgery and referred to our department. The patient opted for aortic valve replacement using a bioprosthesis. Due to the patient's relatively small native aortic valve area, a concurrent root dilatation maneuver (Bo Yang method) was performed to prevent patient-prosthetic mismatch and to allow for the implantation of a sufficiently larger bioprosthesis, facilitating the valve-in-valve procedure. The successful implantation of an Inspiris 25-mm bioprosthesis was achieved. Post-operative 3D-computed tomography revealed no tilting or misalignment of the bioprosthesis, and a properly sized, undistorted Valsalva sinus was observed. Aortic valve replacement using the Bo Yang root enlargement technique is considered a promising alternative for relatively younger patients requiring aortic valve intervention.

3.
Article in Japanese | WPRIM (Western Pacific) | ID: wpr-966089

ABSTRACT

We report a case of redo mitral valve replacement (MVR) for a Björk-Shiley Delrin valve implanted 47 years previously. A 71-year-old man initially underwent MVR for mitral regurgitation at our hospital at the age of 16 years. Following the operation, follow-up examinations were performed at the outpatient clinic and annual transthoracic echocardiogram findings showed only mild mitral regurgitation, with no adverse events noted. However, a transthoracic echocardiogram examination performed 45 years after the operation revealed mild to moderate mitral regurgitation, while dyspnea with exertion was also noted at that time. As part of a more detailed examination, transesophageal echocardiogram results showed moderate transvalvular leakage. Redo MVR was subsequently performed under the diagnosis of prosthetic valve dysfunction. Analysis of the explanted prosthetic valve revealed wear of the Delrin disk, and widening of the gap between the disk and strut, which were presumed to be the cause of transvalvular leakage. A half century has passed since introduction of the Björk-Shiley valve and the present is a rare case of valve malfunction. Presented here are related details, along with a review of existing literature and results of Björk-Shiley valve use at our hospital.

SELECTION OF CITATIONS
SEARCH DETAIL