Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J R Soc Interface ; 14(136)2017 11.
Article in English | MEDLINE | ID: mdl-29093131

ABSTRACT

The competitive pressure from non-vaccine serotypes may have helped pneumococcal conjugate vaccines (PCVs) to limit vaccine-type (VT) serotype prevalence. We aimed to investigate if, consequently, the indirect protection of vaccines targeting most pneumococcal serotypes could fall short of the profound effects of current formulations. We compared three previously described pneumococcal models harmonized to simulate 20 serotypes with a combined pre-vaccination prevalence in children younger than 5-years-old of 40%. We simulated vaccines of increasing valency by adding serotypes in order of their competitiveness and explored their ability to reduce VT carriage by 95% within 10 years after introduction. All models predicted that additional valency will reduce indirect vaccine effects and hence the overall vaccine impact on carriage both in children and adults. Consequently, the minimal effective coverage (efficacy against carriage×vaccine coverage) needed to eliminate VT carriage increased with increasing valency. One model predicted this effect to be modest, while the other two predicted that high-valency vaccines may struggle to eliminate VT pneumococci unless vaccine efficacy against carriage can be substantially improved. Similar results were obtained when settings of higher transmission intensity and different PCV formulations were explored. Failure to eliminate carriage as a result of increased valency could lead to overall decreased impact of vaccination if the disease burden caused by the added serotypes is low. Hence, a comparison of vaccine formulations of varying valency, and pan-valent formulations in particular, should consider the invasiveness of targeted serotypes, as well as efficacy against carriage.


Subject(s)
Immunity, Herd , Models, Immunological , Pneumococcal Vaccines/immunology , Streptococcus pneumoniae/immunology , Vaccination , Humans , Streptococcus pneumoniae/pathogenicity
2.
Comput Biol Med ; 43(11): 1724-31, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24209918

ABSTRACT

The thalassaemias are blood disorders with hereditary transmission. Their distribution is global, with particular incidence in areas affected by malaria. Their diagnosis is mainly based on haematologic and genetic analyses. The aim of this study was to differentiate between persons with the thalassaemia trait and normal subjects by inspecting characteristics of haemochromocytometric data. The paper proposes an original method that is useful in screening activity for thalassaemia classification. A complete working system with a friendly graphical user interface is presented. A unique feature of the presented work is the adoption of a two-layered classification system based on Radial basis function, which improves the performance of the system.


Subject(s)
Algorithms , Computational Biology/methods , Models, Statistical , Thalassemia/diagnosis , Adolescent , Databases, Factual , Female , Humans , Male , Neural Networks, Computer , Thalassemia/classification , Thalassemia/physiopathology
3.
Radiol Med ; 113(4): 477-85, 2008 Jun.
Article in English, Italian | MEDLINE | ID: mdl-18536871

ABSTRACT

The implementation of a database of digitised mammograms is discussed. The digitised images were collected beginning in 1999 by a community of physicists in collaboration with radiologists in several Italian hospitals as a first step in developing and implementing a computer-aided detection (CAD) system. All 3,369 mammograms were collected from 967 patients and classified according to lesion type and morphology, breast tissue and pathology type. A dedicated graphical user interface was developed to visualise and process mammograms to support the medical diagnosis directly on a high-resolution screen. The database has been the starting point for developing other medical imaging applications, such as a breast CAD, currently being upgraded and optimised for use in a distributed environment with grid services, in the framework of the Instituto Nazionale di Fisicia Nucleare (INFN)-funded Medical Applications on a Grid Infrastructure Connection (MAGIC)-5 project.


Subject(s)
Breast Neoplasms/diagnostic imaging , Databases, Factual , Mammography/methods , Radiographic Image Interpretation, Computer-Assisted , Adult , Aged , Female , Humans , Italy , Middle Aged , Radiographic Image Enhancement , Radiographic Image Interpretation, Computer-Assisted/methods , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed
4.
Med Phys ; 33(9): 3469-77, 2006 Sep.
Article in English | MEDLINE | ID: mdl-17022243

ABSTRACT

We describe a portable system for mammographic x-ray spectroscopy, based on a 2 X 2 X 1 mm3 cadmium telluride (CdTe) solid state detector, that is greatly improved over a similar system based on a 3 X 3 X 2 mm3 cadmium zinc telluride (CZT) solid state detector evaluated in an earlier work. The CdTe system utilized new pinhole collimators and an alignment device that facilitated measurement of mammographic x-ray spectra. Mammographic x-ray spectra acquired by each system were comparable. Half value layer measurements obtained using an ion chamber agreed closely with those derived from the x-ray spectra measured by either detector. The faster electronics and other features of the CdTe detector allowed its use with a larger pinhole collimator than could be used with the CZT detector. Additionally, the improved pinhole collimator and alignment features of the apparatus permitted much more rapid setup for acquisition of x-ray spectra than was possible on the system described in the earlier work. These improvements in detector technology, collimation and ease of alignment, as well as low cost, make this apparatus attractive as a tool for both laboratory research and advanced mammography quality control.


Subject(s)
Equipment Failure Analysis/instrumentation , Mammography/instrumentation , Quality Assurance, Health Care/methods , Radiometry/instrumentation , Spectrometry, X-Ray Emission/instrumentation , Calibration , Equipment Design , Equipment Failure Analysis/methods , Miniaturization , Radiation Dosage , Radiometry/methods , Reproducibility of Results , Sensitivity and Specificity , Spectrometry, X-Ray Emission/methods
5.
Med Phys ; 33(8): 3066-75, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16964885

ABSTRACT

Mass localization plays a crucial role in computer-aided detection (CAD) systems for the classification of suspicious regions in mammograms. In this article we present a completely automated classification system for the detection of masses in digitized mammographic images. The tool system we discuss consists in three processing levels: (a) Image segmentation for the localization of regions of interest (ROIs). This step relies on an iterative dynamical threshold algorithm able to select iso-intensity closed contours around gray level maxima of the mammogram. (b) ROI characterization by means of textural features computed from the gray tone spatial dependence matrix (GTSDM), containing second-order spatial statistics information on the pixel gray level intensity. As the images under study were recorded in different centers and with different machine settings, eight GTSDM features were selected so as to be invariant under monotonic transformation. In this way, the images do not need to be normalized, as the adopted features depend on the texture only, rather than on the gray tone levels, too. (c) ROI classification by means of a neural network, with supervision provided by the radiologist's diagnosis. The CAD system was evaluated on a large database of 3369 mammographic images [2307 negative, 1062 pathological (or positive), containing at least one confirmed mass, as diagnosed by an expert radiologist]. To assess the performance of the system, receiver operating characteristic (ROC) and free-response ROC analysis were employed. The area under the ROC curve was found to be Az = 0.783 +/- 0.008 for the ROI-based classification. When evaluating the accuracy of the CAD against the radiologist-drawn boundaries, 4.23 false positives per image are found at 80% of mass sensitivity.


Subject(s)
Artificial Intelligence , Breast Neoplasms/diagnostic imaging , Information Storage and Retrieval/methods , Mammography/methods , Pattern Recognition, Automated/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Radiology Information Systems , Algorithms , Cluster Analysis , Database Management Systems , Databases, Factual , Female , Humans , Radiographic Image Enhancement/methods , Reproducibility of Results , Sensitivity and Specificity
6.
Methods Inf Med ; 44(2): 244-8, 2005.
Article in English | MEDLINE | ID: mdl-15924184

ABSTRACT

OBJECTIVES: The next generation of high energy physics (HEP) experiments requires a GRID approach to a distributed computing system: the key concept is the Virtual ORGANISATION (VO), a group of distributed users with a common goal and the will to share their resources. METHODS: A similar approach, applied to a group of hospitals that joined the GPCALMA project (Grid Platform for Computer Assisted Library for MAmmography), will allow common screening programs for early diagnosis of breast and, in the future, lung cancer. The application code makes use of neural networks for the image analysis and is useful in improving the radiologists' diagnostic performance. GRID services allow remote image analysis and interactive online diagnosis, with a potential for a relevant reduction of the delays presently associated with screening programs. RESULTS AND CONCLUSIONS: A prototype of the system, based on AliEn GRID Services [1], is already available, with a central server running common services [2] and several clients connecting to it. Mammograms can be acquired in any location; the related information required to select and access them at any time is stored in a common service called Data Catalogue, which can be queried by any client. Thanks to the PROOF facility [3], the result of a query can be used as input for analysis algorithms, which are executed on the nodes where the input images are stored,. The selected approach avoids data transfers for all the images with a negative diagnosis and allows an almost real time diagnosis for the set of images with high cancer probability.


Subject(s)
Breast Neoplasms/diagnostic imaging , Internet/instrumentation , Mammography , Radiology Information Systems/instrumentation , Systems Integration , Teleradiology/instrumentation , Algorithms , Database Management Systems , Databases, Factual , Diagnosis, Computer-Assisted , Europe , Female , Humans , Internationality , Italy , Medical Records Systems, Computerized , Program Development , User-Computer Interface
SELECTION OF CITATIONS
SEARCH DETAIL
...