Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38
Filter
Add more filters










Type of study
Publication year range
2.
Visc Med ; 40(3): 128-143, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38873630

ABSTRACT

Background: The management of bulky neoplastic lesions in the digestive tract has historically been a surgical pursuit. With advancements in endoscopic techniques, particularly endoscopic mucosal resection (EMR) and endoscopic submucosal dissection (ESD), a paradigm shift toward organ preservation has been initiated. These endoscopic methods, developed incrementally since the 1980s, have progressively enabled curative management of lesions with minimal morbidity, challenging the previously unchallenged domain of surgery. Summary: This review traces the evolution of endoscopic resection from snare polypectomy and EMR to sophisticated ESD, highlighting the technological innovations that have expanded the scope of endoscopic resection. It discusses the intricacies of various EMR techniques like underwater EMR, anchoring EMR, and hybrid EMR, alongside traction-assisted methods and the use of viscous solutions for submucosal injection. Additionally, the manuscript delves into the advancements in ESD, emphasizing traction strategies, knife technology, and the optimization of endoscopes. The benefits of these advancements are weighed against the challenges in anatomopathological interpretation posed by piecemeal resections. Key Messages: The continuous amelioration of endoscopic resection techniques has significantly improved the outcomes of digestive tract lesion management, particularly in achieving R0 resections and reducing recurrence rates. These advancements represent a monumental step toward minimizing the invasiveness of lesion management. However, despite the progress, the necessity for early follow-up post-EMR remains due to the non-negligible recurrence rates, underscoring the need for a rigorous postoperative surveillance regimen. Furthermore, our review suggests that while ESD has transformed the therapeutic landscape, its widespread adoption hinges on further simplification, safety enhancement, and acceleration of the procedure, possibly through innovations like adaptive traction devices.

4.
Endoscopy ; 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38684193

ABSTRACT

BACKGROUND: The ileocecal valve (ICV) is considered to be one of the most difficult locations for endoscopic submucosal dissection (ESD). The objective of this study was to evaluate the efficacy and safety of traction-assisted ESD in this situation. METHODS: All patients who underwent traction-assisted ESD for an ICV lesion at three centers were identified from a prospective ESD database. En bloc and R0 rates were evaluated. Factors associated with non-R0 resection were explored. RESULTS: 106 patients with an ICV lesion were included. The median lesion size was 50 mm (interquartile range 38-60) and 58.5% (62/106) invaded the terminal ileum. The en bloc and R0 resection rates were 94.3% and 76.4%, respectively. Factors associated with non-R0 resection were lesions covering ≥75% of the ICV (odds ratio [OR] 0.21. 95%CI 0.06-0.76; P=0.02), and involving the anal lip (OR 0.36, 95%CI 0.13-0.99; P=0.04) or more than two sites on the ICV (OR 0.27, 95%CI 0.07-0.99; P=0.03). CONCLUSION: Traction-assisted ESD for treatment of ICV lesions was a safe and feasible option. Large lesions and anal lip involvement appeared to be factors predictive of difficulty.

15.
Endoscopy ; 56(3): 205-211, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37311544

ABSTRACT

BACKGROUND : Good submucosal exposure is key to successful endoscopic submucosal dissection (ESD) and can be achieved with various traction devices. Nevertheless, these devices have a fixed traction force that tends to decrease as the dissection progresses. In contrast, the ATRACT adaptive traction device increases traction during the procedure. METHODS : In this retrospective analysis of prospectively collected data (from a French database), we analyzed ESD procedures performed with the ATRACT device between April 2022 and October 2022. The device was used consecutively whenever possible. We collected details of lesion characteristics, procedural data, histologic outcomes, and clinical consequences for the patient. RESULTS : 54 resections performed in 52 patients by two experienced operators (46 procedures) and six novices (eight procedures) were analyzed. The ATRACT devices used were the ATRACT-2 (n = 21), the ATRACT 2 + 2 (n = 30), and the ATRACT-4 (n = 3). Four adverse events were observed: one perforation (1.9 %), which was closed endoscopically, and three delayed bleeding events (5.5 %). The R0 rate was 93 %, resulting in curative resection in 91 % of cases. CONCLUSION: ESD using the ATRACT device is safe and effective in the colon and rectum, but can also be used to assist with procedures in the upper gastrointestinal tract. It may be particularly useful in difficult locations.


Subject(s)
Endoscopic Mucosal Resection , Humans , Endoscopic Mucosal Resection/methods , Retrospective Studies , Rectum , Dissection/adverse effects , Dissection/methods , Traction , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...