Arch Orthop Trauma Surg ; 144(5): 2283-2295, 2024 May.
Article in English | MEDLINE | ID: mdl-38625551

ABSTRACT

INTRODUCTION: The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates. METHODS: Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan-Meier curve and compared between groups via Log-Rank-Tests. RESULTS: 3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7). CONCLUSION: There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Prosthesis Failure , Registries , Reoperation , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Germany/epidemiology , Reoperation/statistics & numerical data , Male , Aged , Female , Tibia/surgery , Middle Aged , Bone Cements
2.
Radiol Case Rep ; 19(5): 1843-1846, 2024 May.
Article in English | MEDLINE | ID: mdl-38420341

ABSTRACT

Lipoma arborescens is a rare benign intra articular lesion characterized by lipomatous proliferation of the synovium. The condition typically affects the knee presenting with atraumatic pain and swelling. It should be considered in the differential diagnosis of monoarthritis and joint effusion. Diagnosis is made on MRI with characteristic features. We present a rare case of lipoma arborescens with patellofemoral osteoarthritis and genu valgum. We discuss the clinical presentation, radiological findings, and management.

3.
Injury ; 2023 Apr 05.
Article in English | MEDLINE | ID: mdl-37032184

ABSTRACT

BACKGROUND: Literature shows conflicting results regarding spinal (SA) or general anesthesia (GA) and their influence on the outcome of elderly patients with hip fractures. We, therefore, conducted an analysis from the Registry for Geriatric Trauma (ATR-DGU). METHODS: A retrospective, multicenter registry study including patients aged 70 years or above with hip fractures requiring surgery from 131 Centers for Geriatric Trauma (AltersTraumaZentrum DGU®) from 2016 to 2021. Patients with SA or GA were compared using matched-pair analysis and linear and logistic regression models. RESULTS: A total of 43,714 patients were included, of whom 3,242 received SA. The median age was 85 (SA) and 84 years (GA). Adjustments for the American Society of Anesthesiologists (ASA) grade, sex, age, additional injuries, and anticoagulation resulted in a higher in-hospital (odds ratio (OR) 1.31; 95% confidence interval [CI], 1.07 - 1.61, p = 0.009) and 120 days mortality (OR 1.47; 95% CI, 1.1 - 1.95, p = 0.009) in the GA group. GA had a significant negative influence on walking ability seven days after surgery and on the quality of life (QoL). The length of hospital stay (LoS) was significantly shorter in the SA group. CONCLUSIONS: SA is associated with a higher survival rate, a better walking ability seven days after surgery, a higher QoL, and a shorter LoS.

4.
PLoS One ; 18(4): e0278850, 2023.
Article in English | MEDLINE | ID: mdl-37014837

ABSTRACT

BACKGROUND: While postoperative malrotation in the subtrochanteric region is a well-known problem, malrotation after osteosynthesis in proximal femoral fractures has not been extensively studied. In this context, many methods for perioperatively assessment of femoral torsion have been described, but none of them is applicable in the basicervical region of the proximal femur. As an important difference in femoral neck fractures, the discontinuous neck fails to serve as a significant "pointer" for measurements and malfunctions to be placed in relation to the condylar plane. Considering postoperative maltorsion at any location as a substantial negative effect on patients' outcome and functional expectations, precise and patient-friendly rotation measurement standards in femoral neck fractures are desired in clinical practice. Recently, a novel computed tomography (CT) based geometric technique was described named "direct measurement" with promising results covering this diagnostic disparity, but still requires validation. Thus, we aimed to validate the previously described technique using a controlled range of displacement in a femoral neck fracture Sawbone® model. METHODS AND FINDINGS: A goniometer was designed to set retro- and anteversion of the proximal femur in a reproducible manner. Prospectively, all femurs underwent a CT scan and were measured 3D for displacement. The interclass correlation between the CT measurements and the goniometer measurements was calculated and was found to be very high (1.00, 95% confidence interval: 0.99-1.00; p < 0.001). For the mean of all measurements, the Pearson's correlation was 1.00 (p < 0.001). No significant differences in the measurements of both investigators were observed, with 20° of retroversion not significant (-1.20 ± 1.71; 95% confidence interval: -2.43-0.03; p = 0.054). CONCLUSION: This CT-based 3D measurement technique may allow for perioperative malrotation assessment in basicervical femoral neck fractures and appears to be feasible in femoral neck fractures when it comes to rare cases of osteosynthesis. Further investigations are still needed to define the thresholds of malrotation provoking functional impairment after osteosynthesis in basicervical femoral neck fractures.


Subject(s)
Femoral Fractures , Femoral Neck Fractures , Humans , Femur/surgery , Tomography, X-Ray Computed/methods , Femoral Neck Fractures/diagnostic imaging , Femoral Neck Fractures/surgery , Fracture Fixation, Internal
5.
Arch Orthop Trauma Surg ; 143(3): 1549-1569, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36450936

ABSTRACT

INTRODUCTION: Revision total knee arthroplasty (RTKA) has been increasing continuously. The results of RTKA still remain unsatisfactory. Failure patterns and risk factors in RTKA were thoroughly analyzed, with periprosthetic joint infections (PJI) and aseptic loosening remaining at the forefront of re-revision (ReRTKA) causes. While there is evidence that stem profile impacts the revisability of cemented implants, its association with the modes of RTKA failure is unknown. METHODS: 50 consecutive ReRTKA performed in a single orthopedic center during 2016-2017 were retrospectively analyzed. The cases were stratified according to age, sex, number of preexisting revisions, fixation technique, stem design and causes of re-revision. All explanted implants with conical vs. cylindrical stem profiles were compared. RESULTS: Mean age was 67 ± 11.5, and 54% were females. 72% of the cases had ≥ 3 previous revisions. 88% were full-cemented, 3% hybrid and 9% press-fit stems. 36% of the RTKA had conical, 58% cylindrical and 6% combined stem profiles. 92% of the RTKA components were removed. Removal causes were: PJI (52.2%), aseptic loosening (34.8%), implant malposition (9.8%), painful knee (1.1%) and instability (2.2%). While the overall RTKA failure patterns were equally distributed between conical and cylindrical stems, subgroup analysis of only cemented ReRTKA revealed a higher incidence of aseptic loosening within cylindrical stem profiles (46.7% vs. 25.7%, P = 0.05). CONCLUSION: Stem profile may have an impact on the process of aseptic loosening in cemented non-metaphyseal engaging RTKA, with cylindrical designs tending to worse outcomes than conical designs. Large cohort studies could provide more clarity on current observation.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Female , Humans , Middle Aged , Aged , Male , Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Retrospective Studies , Prosthesis Failure , Reoperation/methods , Prosthesis Design
6.
Arch Orthop Trauma Surg ; 143(1): 469-479, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35930052

ABSTRACT

INTRODUCTION: While re-revision total knee arthroplasty (ReRTKA) steadily increases, the ease and bone-sparing removal of RTKA implants is gaining more and more in importance. Biomechanical data suggest that cemented conical stems can be removed significantly easier than cylindrical stems. However, no clinical evidence exists supporting this observation. Aim of this study was to compare the revisability and need for osteotomy (OT) between removals of well-fixed cemented conical vs. cylindrical RTKA stems. MATERIALS AND METHODS: 55 removals of well-fixed full-cemented RTKA stems (29 knees) performed between 2016 and 2018 were retrospectively analyzed. Main outcome variables were: bone loss, fractures, osteotomy incidence, surgery duration, early postoperative complications (EPC), hemoglobin drop and blood transfusion. SPSS was used for the statistical analysis. RESULTS: 44.8% were conical, 48.3% cylindrical, and 6.9% combined stem designs. Causes for re-revision were PJI (75.9%), malposition (17.2%) and persistent pain (6.9%). 10 stem removals (18.2%) required an OT (four femoral, six tibial): eight stems (14.5%) had cylindrical and two (3.6%) conical designs (P = 0.041). Fractures were noted solely in removals without OT (11.1% vs. 0%,). There was a tendency to more bone loss in cylindrical stem revisions (53.8% vs. 32%, P = 0.24). A longer overall surgery time was observed in revisions of cylindrical stems (+ 37 min, P = 0.05). There was higher hemoglobin drop and need for blood transfusion in revisions of cylindrical stems or after OT but without reaching statistical significance. The EPC rates were slightly higher in ReRTKA on cylindrical stems (P = 0.28). CONCLUSION: Well-fixed cemented conical stems may be revision friendlier with less demands on OT and shorter overall surgery time than cemented cylindrical stems.


Subject(s)
Arthroplasty, Replacement, Knee , Fractures, Bone , Knee Prosthesis , Humans , Arthroplasty, Replacement, Knee/adverse effects , Fractures, Bone/complications , Hemoglobins , Knee Prosthesis/adverse effects , Osteotomy/adverse effects , Prosthesis Design , Prosthesis Failure , Reoperation , Retrospective Studies
7.
Medicina (Kaunas) ; 58(11)2022 Nov 07.
Article in English | MEDLINE | ID: mdl-36363567

ABSTRACT

Background and Objectives: Fractures of the proximal femur are a life-changing and life-threatening event for older people. Concomitant malnutrition has been described as an independent risk factor for complications and mortality. Therefore, we examined the influence of albumin and body mass index (BMI) as parameters for the nutritional state on the outcome after geriatric hip fracture surgery. Materials and Methods: Data were retrospectively collected from hospital information systems, and complications and all other parameters were obtained from patient charts. We included patients aged 70 years or above with a fracture of the proximal femur. We excluded periprosthetic and peri-implant fractures and patients with a missing BMI or albumin value. Results: Patients with a BMI below 20 kg/m2 were more likely to be female but did not differ from the normal BMI group in terms of baseline parameters. Patients with hypoalbuminemia had a higher ASA grade and Charlson Comorbidity Index, as well as a lower hemoglobin value and prothrombin time compared to those with normal albumin values and low BMI. Hypoalbuminemia was associated with significantly increased rates of complications (57.9% vs. 46.7%, p = 0.04) and mortality (10.3% vs. 4.1%, p = 0.02). Blood loss and transfusion rates were higher in the hypoalbuminemia group. Patients with a BMI below 20 kg/m2 had a higher risk of intraoperative cardiac arrest (2.6% vs. 0.4%, p = 0.05) but did not show higher mortality rates than patients with a BMI above 20 kg/m2. However, the outcome parameter could not be confirmed in the regression analysis. Conclusions: Hypoalbuminemia might be an indicator for more vulnerable patients with a compromised hemoglobin value, prothrombin time, and ASA grade. Therefore, it is also associated with higher mortality and postoperative complications. However, hypoalbuminemia was not an independent predictor for mortality or postoperative complications, but low albumin values were associated with a higher CCI and ASA grade than in patients with a BMI below 20 kg/m2.


Subject(s)
Hip Fractures , Hypoalbuminemia , Malnutrition , Humans , Aged , Female , Male , Body Mass Index , Retrospective Studies , Hypoalbuminemia/complications , Malnutrition/complications , Hip Fractures/complications , Hip Fractures/surgery , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Risk Factors , Femur , Albumins
8.
Biomedicines ; 10(2)2022 Feb 21.
Article in English | MEDLINE | ID: mdl-35203721

ABSTRACT

Effects of hydroxyapatite (HA) particles with bone morphogenetic BMP-2 or GDF-5 were compared in sheep lumbar osteopenia; in vitro release in phosphate-buffered saline (PBS) or sheep serum was assessed by ELISA. Lumbar (L) vertebral bone defects (Ø 3.5 mm) were generated in aged, osteopenic female sheep (n = 72; 9.00 ± 0.11 years; mean ± SEM). Treatment was: (a) HA particles (2.5 mg; L5); or (b) particles coated with BMP-2 (1 µg; 10 µg) or GDF-5 (5 µg; 50 µg; L4; all groups n = 6). Untouched vertebrae (L3) served as controls. Three and nine months post-therapy, bone formation was assessed by osteodensitometry, histomorphometry, and biomechanical testing. Cumulative 14-day BMP release was high in serum (76-100%), but max. 1.4% in PBS. In vivo induction of bone formation by HA particles with either growth factor was shown by: (i) significantly increased bone volume, trabecular and cortical thickness (overall increase HA + BMP vs. control close to the injection channel 71%, 110%, and 37%, respectively); (ii) partial significant effects for bone mineral density, bone formation, and compressive strength (increase 17%; 9 months; GDF-5). Treatment effects were not dose-dependent. Combined HA and BMPs (single low-dose) highly augment long-term bone formation and biomechanical stabilization in sheep lumbar osteopenia. Thus, carrier-bound BMP doses 20,000-fold to 1000-fold lower than previously applied appear suitable for spinal fusion/bone regeneration and improved treatment safety.

9.
J Orthop Sci ; 27(1): 146-152, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33309404

ABSTRACT

BACKGROUND: Posttraumatic maltorsion and implant failure after closed reduction of proximal femoral fractures remain a cause of concern. Although the reproducibility of torsion measuring techniques on CT for femoral shaft fractures has been thoroughly analyzed, little is known about the trochanteric fractures. Apart from the well-known CT limitations, posttraumatic alteration of bony landmarks makes torsional assessment even more challenging. Main goal of this study was to examine the reliability of different CT techniques on trochanteric femoral fractures after closed nail fixation. Secondary goal was to see whether the measurements within the examined population were influenced by the fracture type and patient age or BMI. METHODS: 20 cases (AO.31-A1 or -A2) were retrospectively examined. Six established CT techniques for torsional assessment were performed from three different investigators twice at different time points. The intraclass correlation coefficient (ICC for 95% CI) was used to analyze the interobserver and intraobserver reliability. RESULTS: The Hernandez method (0.986) followed by the Jend method (0.982) by a mean difference of <1° showed the highest reliability. Although increasing fracture complexity from A1 to A2 led to an overall worsening of the measurement precision, the Hernandez and Jend techniques revealed a very good consistency. Within the examined population, age and BMI had no impact on the precision of the measurements. CONCLUSIONS: The Hernandez and Jend methods represent reliable alternatives for torsional assessment of trochanteric femur fractures treated with closed nail fixation when compared to the other measurement techniques here involved. Documentation of the torsion measuring method used in each case constitutes an essential element of the radiological reports.


Subject(s)
Femoral Fractures , Hip Fractures , Bone Nails , Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery , Hip Fractures/diagnostic imaging , Hip Fractures/surgery , Humans , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed
10.
Arch Orthop Trauma Surg ; 142(9): 2173-2183, 2022 Sep.
Article in English | MEDLINE | ID: mdl-33651145

ABSTRACT

BACKGROUND: Gluteal tendon tears (GTT) can cause pain and weakness of the hip. We analyze the impact of gluteal muscle fatty degeneration, atrophy and tear morphology on clinical outcomes of surgical repair. METHODS: All sequential patients receiving surgical repair of GTTs via anchor sutures between 1/2015 and 11/2018 were retrospectively identified. MRIs were reviewed by a radiologist for tendon retraction, muscle atrophy and tear size. The Goutallier-Fuchs Classification (GFC) was used to quantify fatty degeneration as < 2° or ≥ 2°. Demographic and clinical variables were abstracted from the electronic records. The surveys HHS Section 1 and HOOS Jr. were obtained at last follow-up. The Pearson correlation and one-way ANOVA tests served for statistical analysis of clinical variance. RESULTS: 38 patients were identified, 29 (76.3%) were female. The average age was 67. Of the 11 (28.9%) patients with a prior hip arthroplasty 87.5% of primary THAs had a direct lateral approach. 29 (76.3%) patients were treated open and 9 (23.7%) arthroscopically. At an average follow-up of 20.9 months, patients reported a significant improvement in pain (97%), analgesic use (85.7%), limp (52.6%) and abduction strength (54.2%) (all: P ≤ 0.01). GFC ≥ 2° were associated with significantly worse outcomes in terms of limp (0.19/3 vs. 1.2/3, P = 0.05), HHS-S1 (58.19 vs. 71.68, P = 0.04) and complication rates (37.5% vs. 0%, P = 0.02). There was a strong correlation between tear retraction (P = 0.005), tear size (P = 0.009) and muscle atrophy (P = 0.001) with GFC ≥ 2° but not with clinical outcomes. GFC ≥ 2° was strongly related to lateral THA exposures (P < 0.001). Surgical approach had no impact on clinical outcomes. CONCLUSION: While fatty degeneration can negatively impact functional outcomes, pain relief is reliably achieved. Tear morphology and muscle atrophy did not correlate with outcomes in this patient cohort. Patients should be counseled to expect a residual limp after surgery if they have GFC ≥ 2° on MRI.


Subject(s)
Tendon Injuries , Aged , Buttocks , Female , Humans , Magnetic Resonance Imaging , Male , Muscle, Skeletal/surgery , Muscular Atrophy , Pain , Retrospective Studies , Rupture , Tendon Injuries/surgery , Tendons/surgery
11.
Arch Bone Jt Surg ; 9(2): 203-210, 2021 Mar.
Article in English | MEDLINE | ID: mdl-34026938

ABSTRACT

BACKGROUND: Whilst traumatology around elderly population becomes more and more popular nowadays, the knowledge of local bone quality prior to osteosynthesis is of paramount importance. Assessment of the local bone mechanical properties provides essential information related to implant stability and can support treatment strategies in a timely manner. In the acute setting, dual-energy X-ray absorptiometry and quantitative computer tomography cannot be used routinely, and up till now no known intraoperative methods have been established. METHODS: A novel technique was developed to determine the local bone strength. A feasibility and sensitivity analysis were performed on synthetic cancellous bone models of various densities [including osteoporotic ranges (0.12 - 0.48g/cm3)] by testing the permeability of different rod probe designs. RESULTS: The Intraoperative Osseomechanical Strength Measurement (IOSM) method revealed high sensitivity for the evaluation of local density on synthetic bone material. Among the indenter designs tested, the one with 40° sharp apex and 5 mm diameter reflected accurately the density changes of the synthetic bones. It was also associated with less invasiveness posing no risk for the primary implant stability of the osteosynthesis that may follow. CONCLUSION: The IOSM method using the indicated indenter design on synthetic cancellous models appears to be a minimal invasive technique with high accuracy in identifying different bone densities . Further studies on human bone material are now focused on the evaluation of the IOSM sensitivity compared to the gold standards (Dual-energy X-ray absorptiometry and quantitative computer tomography).

12.
Clin Biomech (Bristol, Avon) ; 84: 105327, 2021 04.
Article in English | MEDLINE | ID: mdl-33773169

ABSTRACT

BACKGROUND: Cut-out of gamma nail often results from poor primary bone stability, suboptimal reduction (varus) and excentric placement of the head element which may lead to "instability" and frequently requires revision. Various studies have shown that augmentation with polymethylmethacrylate cement increases the primary stability of osteosynthesis. However, it has not yet been widely used in fracture treatment due to certain disadvantages, e.g., the lack of osteointegration, the formation of an interface membrane or the presence of toxic monomers. Few studies show that biodegradable bone cements increase the stability of osteosynthesis in different anatomical regions and therefore could be an alternative to polymethylmethacrylate cement in the treatment of pertrochanteric fractures. METHODS: Two biomechanical situations were simulated using 24 Sawbones (simple and multifragmentary pertrochanteric fractures; AO-classification 31-A1 and 31-A2. Both groups were stabilized using the Gamma3® nailing system with and without biodegradable bone cement. Sawbones underwent the same cyclic loading test, simulating 10.000 gait cycles loading the bones with three times body weight. Migration was determined by comparing computed tomography scans recorded before and after the mechanical testing. The three-dimensional migration of the lag screw was calculated, and the rotation of the head around the longitudinal axis was determined. FINDINGS: Biodegradable cement reduced migration by approximately 35% in 31-A1 fractures (25.4% in 31-A2 fractures) and the rotation of the head around the lag screw by approximately 37% in 31-A1 fractures (17.8%, 31-A2). INTERPRETATION: Use of biodegradable bone cement improved the primary stability of gamma nail osteosynthesis in the biomechanical model.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Biomechanical Phenomena , Bone Cements/therapeutic use , Fracture Fixation, Internal , Humans
13.
J Arthroplasty ; 35(6S): S352-S358, 2020 06.
Article in English | MEDLINE | ID: mdl-32279942

ABSTRACT

BACKGROUND: Little is known about the relative efficacy of open (OGR) vs endoscopic (EGR) gluteal tendon repair of gluteal tendon tears in minimizing pain and restoring function. Our aim is to compare these 2 surgical techniques and quantify their impact on clinical outcomes. METHODS: All patients undergoing gluteal tendon tear repair at our institution between 2015 and 2018 were retrospectively reviewed. Pain scores, limp, hip abduction strength, and the use of analgesics were recorded preoperatively and at last follow-up. The Hip disability and Osteoarthritis Outcome Score Junior and Harris Hip Score Section1 were obtained at last follow-up. Fatty degeneration was quantified using the Goutallier-Fuchs Classification (GFC). Statistical analysis was conducted using one-way analysis of variance and t-tests. RESULTS: Forty-five patients (mean age 66, 87% females) met inclusion criteria. Average follow-up was 20.3 months. None of the 10 patients (22%) undergoing EGR had prior surgery. Of 35 patients (78%) undergoing OGR, 12 (27%) had prior hip replacement (75% via lateral approach). The OGRs had more patients with GFC ≥2 (50% vs 11%, P = .02) and used more anchors (P = .03). Both groups showed statistical improvement (P ≤ .01) for all outcomes measured. GFC >2 was independently associated with a worst limp and Harris Hip Score Section 1 score (P = .05). EGR had a statistically higher opioid use reduction (P < .05) than OGR. Other comparisons between EGR and OGR did not reach statistical significance. CONCLUSION: In this series, open vs endoscopic operative approach did not impact clinical outcomes. More complex tears were treated open and with more anchors. Fatty degeneration adversely impacted outcomes. Although further evaluation of the efficacy of EGR in complex tears is indicated, both approaches can be used successfully.


Subject(s)
Suture Anchors , Tendon Injuries , Aged , Buttocks , Female , Humans , Male , Muscle, Skeletal , Retrospective Studies , Tendon Injuries/surgery , Tendons
14.
Arch Orthop Trauma Surg ; 140(6): 727-734, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31696321

ABSTRACT

INTRODUCTION: The increasing number of geriatric traumatology cases has intensified the need to reliably and objectively evaluate local bone quality, the latter poses a decisive factor for the choice of an optimal approach to treat osteoporotic fractures. Osteodensitometry imaging techniques are not routinely available in acute operative settings, nor do they provide objective information on local bone properties specifically needed for the prognosis of implant stability. MATERIALS AND METHODS: This study sought to verify ex vivo the feasibility and sensitivity of a novel method for the determination of local bone strength in the acute operative setting (intraoperative osseomechanical strength measurement; IOSM) that is based on the principle of material displacement resistance against the force of a rotary indenter. Samples consisted of human femoral heads obtained after total hip replacement. Comparisons were made with results obtained via conventional dual-energy X-ray absorptiometry (DXA) and quantitative computed tomography (qCT). RESULTS: Regression analyses of the results showed a highly significant correlation between the IOSM and the control methods (r = 0.61 and r = 0.56; p < 0.01), indicating that this new approach qualifies as a reliable tool for the intraoperative evaluation of the intrinsic local bone strength. CONCLUSIONS: The intraoperative integration of this method may support surgeon on taking proper decisions in terms of optimal surgical approaches and prevention of complications inherent to osteoporotic bone.


Subject(s)
Biomechanical Phenomena/physiology , Femur , Intraoperative Period , Orthopedic Procedures/methods , Absorptiometry, Photon , Feasibility Studies , Femur/physiopathology , Femur/surgery , Humans , Tomography, X-Ray Computed
15.
J Back Musculoskelet Rehabil ; 32(6): 897-903, 2019.
Article in English | MEDLINE | ID: mdl-30958330

ABSTRACT

BACKGROUND AND OBJECTIVES: Bone marrow oedema is a multifactorial conditioned illness. Alongside any strain relief of an affected joint, treatment with Iloprost also belongs to the choice of cures. In past studies, a modulatory effect on bone could be shown. The hypothesis of the present work is that Iloprost has a growth-stimulating effect on osteoblasts in vitro. METHODS: Human osteoblasts were isolated and cultivated. Subsequently, the cells were treated with Iloprost in bioavailable concentrations. Alterations of the cell structure were examined by means of light microscopy. A regulation of the number of vital cells was carried out by using a CASY cell counter. Possible cell impairment after Iloprost treatment was analysed by means of XTT Elisa as well as FDA and PI staining via fluorescence microscopy. RESULTS: Using light microscopy, no changes in cell structure could be observed. With the CASY cell counter, no increase in the numbers of osteoblasts appeared after Iloprost treatment. Also, XTT Elisas and fluorescence microscopy did not reveal any cell impairment due to Iloprost. CONCLUSION: Our results could not confirm a modulatory effect in mature osteoblasts. On the basis of the present work we could not verify any growth-stimulating effect by Iloprost in mature osteoblasts in vitro. Admittedly, effects had been shown previously during osteogenesis, but we do exclude an effect on mature osteoblasts which have already differentiated.


Subject(s)
Iloprost/pharmacology , Osteoblasts/drug effects , Vasodilator Agents/pharmacology , Cells, Cultured , Humans , Microscopy , Osteoblasts/pathology
16.
Arch Orthop Trauma Surg ; 139(7): 991-998, 2019 Jul.
Article in English | MEDLINE | ID: mdl-30927062

ABSTRACT

BACKGROUND: Easy revisability is gaining increasingly in importance. The removal of well-fixed cemented stems is very demanding and is often associated with increased operative morbidity. Implant design may be here a decisive impact factor, and the best way to ascertain it is experimentally. Aim of this study is to assess different cemented stems of established knee revision implants in regard to their removal capability. METHODS: Based on their sagittal profile, five stem extensions from known manufacturers were divided in conical, conical-cylindrical and cylindrical designs. The pedicles were also characterized in respect to their cross section, diameter and surface roughness. The cemented stems were dismounted six times each in a reproducible biomechanical setup. The explantation energy required was determined and statistical analyzed. RESULTS: The conical shaft needed significantly the slightest explantation energy with 19.2 joules (p = 0.004). There was a strong negative linear correlation between conicity proportion and explantation energy of the cemented stems (R2 = 0.983). The removal of the three purely cylindrical shafts-regardless of their differences in diameter, cross-sectional design and surface- was the most demanding (98.3, 105, and 116.7 joules) with only secondary differences between them. CONCLUSION: The longitudinal stem profile may have a primary impact on the explantability of well-fixed cemented shafts with conical designs showing superiority. Cross-sectional profile and surface roughness had here a less decisive influence on the explantability. Surgeons can choose proper implants and removal techniques depending on potential implant-associated revision risks and re-revisions to be expected.


Subject(s)
Arthroplasty, Replacement, Knee , Device Removal/methods , Knee Joint , Knee Prosthesis , Prosthesis Design , Reoperation/methods , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Arthroplasty, Replacement, Knee/methods , Biomechanical Phenomena , Cross-Sectional Studies , Equipment Failure Analysis , Humans , Knee Joint/physiopathology , Knee Joint/surgery , Knee Prosthesis/adverse effects , Knee Prosthesis/classification , Materials Testing , Prosthesis Design/adverse effects , Prosthesis Design/methods
17.
Arch Orthop Trauma Surg ; 138(12): 1747-1754, 2018 Dec.
Article in English | MEDLINE | ID: mdl-30367254

ABSTRACT

BACKGROUND: According to literature, more than 30% of revised knee arthroplasties will require at least one re-revision. Practical experience has shown that there are considerable product-specific differences in the explantability of cemented long-stem prostheses. In the registers of successful implants, stem geometry varies considerably between the manufacturers. However, comparative data on explantability of the respective stems are missing. Objective of the present study was to identify a correlation between the geometry of a smooth cemented long stem and the necessary explantation energy required until failure of the implant-cement interface occurs. METHODS: Eight cemented stems with different conical profile angles (0°-3°) were explanted in a reproducible biomechanical setup each six times to evaluate the correlation between the stem design and the required explantation energy. RESULTS: The average explantation energy was highest in the case of the cylindrical stem, at 18.1 ± 3.6 J. At a cone angle of 0.25°, it was just 12.1 ± 2.1 J (p < 0.001) and dropped beyond 0.5° to an average of 5.7 ± 1.8 J (p < 0.001). Between 0.5° and 3°, no significant difference in the required extraction energy was observed. CONCLUSIONS: Whereas smooth conical stems can mostly be removed easily, an early decision in favour of osteotomy or fenestration can be taken in the case of cylindrical cemented stems.


Subject(s)
Arthroplasty, Replacement, Knee/instrumentation , Bone Cements/adverse effects , Knee Prosthesis/adverse effects , Prosthesis Design/methods , Prosthesis Failure/etiology , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Humans , Prosthesis Design/adverse effects , Reoperation
18.
Eur J Orthop Surg Traumatol ; 28(6): 1001-1015, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29470650

ABSTRACT

Traumatic knee dislocation is a rare but potentially limb-threatening injury. Thus proper initial diagnosis and treatment up to final ligament reconstruction are extremely important and a precondition to successful outcomes. Reports suggest that evidence-based systematic approaches lead to better results. Because of the complexity of this injury and the inhomogeneity of related literature, there are still various controversies and knowledge gaps regarding decision-making and step-sequencing in the treatment of acute multi-ligament knee injuries and knee dislocations. The use of ankle-brachial index, routine or selective angiography, braces, joint-spanning or dynamic external fixation, and the necessity of initial ligament re-fixation during acute surgery constitutes current topics of a scholarly debate. The aim of this article was to provide a comprehensive literature review bringing light into some important aspects about the initial treatment of knee dislocation (vascular injury, neural injury, immobilization techniques) and finally develop an accurate data-based universal algorithm, enabling attending physicians to become more acquainted with the management of acute knee dislocation.


Subject(s)
Knee Dislocation/diagnosis , Knee Dislocation/therapy , Ligaments, Articular/surgery , Algorithms , Humans , Immobilization/methods , Knee Dislocation/complications , Knee Dislocation/surgery , Knee Joint/blood supply , Knee Joint/innervation , Knee Joint/surgery , Ligaments, Articular/injuries , Peripheral Nerve Injuries/etiology , Peripheral Nerve Injuries/therapy , Plastic Surgery Procedures/methods , Vascular System Injuries/etiology , Vascular System Injuries/therapy
19.
J Orthop Sci ; 17(6): 717-21, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22895823

ABSTRACT

PURPOSE: In a previous study, our group introduced a simple non-invasive method for the intraoperative control of femoral torsion during closed nailing of femoral fractures using the shape of the greater trochanter and its relation to the femoral head. The aim of this study was to verify the results of our cadaveric study and transfer them into a clinical setup. We answered the questions: How much time is needed to perform the greater trochanter-head contact point method (GT-HCP)? How long is the radiation time? METHODS: We examined 15 patients with femoral shaft fractures, to evaluate the GT-HCP method in a clinical setup. Using a standard fluoroscopic image intensifier (Ziehm, Erlangen, Germany), the greater trochanter-head contact angle was measured for both sides. All patients received a postoperative computer tomography (CT) to check the rotational malalignment. The mean of the CT results was then compared to the measurements of the GT-HCP method. The examiners performing the CT measurements were not aware of the GT-HCP results and vice versa. RESULTS: No statistical significance could be detected between the CT and the GT-HCP method (p = 0.853). Eleven patients had very good results (≤5°), three had good results (6-10°) and one had poor results (>10°). The mean difference between CT and GT-HCP method was 3.7 ± 3.3°, which is acceptable. The radiation dose needed for the method was not large (0.2 ± 0.1 min), and could be lowered with the gaining experience of the examiners. Similarly, the overall time needed (12.1 ± 4.9 min) for the GT-HCP method could be reduced with the experience of the team. CONCLUSION: Our study showed that the GT-HCP method is a precise and not particularly time consuming method for controlling anteversion during closed femoral nailing. Further clinical trials including a larger number of patients are required to establish this method in clinical practice.


Subject(s)
Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery , Femur Head , Fracture Fixation, Intramedullary , Intraoperative Care , Torsion Abnormality/diagnosis , Adult , Body Weights and Measures , Bone Nails , Cohort Studies , Female , Femoral Fractures/physiopathology , Hip Joint , Humans , Knee Joint , Male , Middle Aged , Range of Motion, Articular , Tomography, X-Ray Computed , Torsion Abnormality/etiology , Torsion Abnormality/prevention & control , Young Adult
SELECTION OF CITATIONS