1.
J Am Soc Echocardiogr ; 35(11): 1146-1155, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35798123

ABSTRACT

BACKGROUND: Myocardial scar correlates with clinical outcomes. Traditionally, late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is used to detect and quantify scar. In this prospective study using LGE CMR as reference, the authors hypothesized that nonlinear ultrasound imaging, namely, power modulation, can detect and quantify myocardial scar in selected patients with previous myocardial infarction. In addition, given the different histopathology between ischemic and nonischemic scar, a further aim was to test the diagnostic performance of this echocardiographic technique in unselected consecutive individuals with ischemic and nonischemic LGE or no LGE on CMR. METHODS: Seventy-one patients with previous myocardial infarction underwent power modulation echocardiography following CMR imaging (group A). Subsequently, 101 consecutive patients with or without LGE on CMR, including individuals with nonischemic LGE, were scanned using power modulation echocardiography (group B). RESULTS: In group A, echocardiography detected myocardial scar in all 71 patients, with good scar volume agreement with CMR (bias = -1.9 cm3; limits of agreement [LOA], -8.0 to 4.2 cm3). On a per-segment basis, sensitivity was 82%, specificity 97%, and accuracy 92%. Sensitivity was higher in the inferior and posterior segments and lower in the anterior and lateral walls. In group B, on a per-subject basis, the sensitivity of echocardiography was 62% (91% for ischemic and 30% for nonischemic LGE), with specificity and accuracy of 89% and 72%, respectively. The bias for scar volume between modalities was 5.9 cm3, with LOA of 34.6 to 22.9 cm3 (bias = -1.9 cm3 [LOA, -11.4 to 7.6 cm3] for ischemic LGE, and bias = 18.9 cm3 [LOA, -67.4 to 29.7.6 cm3] for nonischemic LGE). CONCLUSIONS: Power modulation echocardiography can detect myocardial scar in both selected and unselected individuals with previous myocardial infarction and has good agreement for scar volume quantification with CMR. In an unselected cohort with nonischemic LGE, sensitivity is low.


Subject(s)
Cicatrix , Myocardial Infarction , Humans , Cicatrix/diagnostic imaging , Gadolinium , Contrast Media/pharmacology , Prospective Studies , Predictive Value of Tests , Myocardium/pathology , Echocardiography/methods , Myocardial Infarction/complications , Myocardial Infarction/diagnosis , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging, Cine/methods
5.
Front Cardiovasc Med ; 8: 693732, 2021.
Article in English | MEDLINE | ID: mdl-34497834

ABSTRACT

Backgsround: Infective endocarditis (IE) of prosthetic valves is a dire complication of cardiac valve replacement surgery and is associated with high rates of morbidity and mortality. Case Summary: A 72-year-old woman with multiple comorbidities underwent surgical replacement of the aortic valve with a mechanical prosthetic valve after recurrent IE. After 10 years, IE recurred and the mechanical valve was surgically replaced with a bioprosthetic valve. Ten years later, severe heart failure developed due to severe paravalvular leak (PVL) caused by an aortic annulus abscess complicated by a paravalvular pseudoaneurysm fistula (PPF). The patient was deemed at prohibitive surgical risk and a catheter-based PVL closure procedure was planned. However, the interventional procedure was delayed several months due to the Covid-19 pandemic with progressive heart failure worsening. Despite an acute satisfactory result of the PPF transcatheter closure and a significant clinical improvement, the patient died 10 months later due to multiorgan failure. It is likely that this was due, at least in part, to the long treatment delay caused by the unprecedented strain on the healthcare system. Discussion: In patients at high surgical risk, early diagnosis and prompt interventional treatment of severe PVL are crucial for improving expectancy and quality of life. However, the recent outbreak of COVID-19 caused deferral of elective and semi-elective structural heart disease procedures (SHD) as in our case. Thus, a proactive and vigilant stance on managing SHD should be a priority even in the context of the COVID-19 pandemic.

6.
J Am Soc Echocardiogr ; 34(10): 1095-1105.e6, 2021 10.
Article in English | MEDLINE | ID: mdl-34082020

ABSTRACT

BACKGROUND: Myocardial scar appears brighter compared with normal myocardium on echocardiography because of differences in tissue characteristics. The aim of this study was to test how different ultrasound pulse characteristics affect the brightness contrast (i.e., contrast ratio [CR]) between tissues of different acoustic properties, as well as the accuracy of assessing tissue volume. METHODS: An experimental in vitro "scar" model was created using overheated and raw pieces of commercially available bovine muscle. Two-dimensional and three-dimensional ultrasound scanning of the model was performed using combinations of ultrasound pulse characteristics: ultrasound frequency, harmonics, pulse amplitude, steady pulse (SP) emission, power modulation (PM), and pulse inversion modalities. RESULTS: On both two-dimensional and three-dimensional imaging, the CR between the "scar" and its adjacent tissue was higher when PM was used. PM, as well as SP ultrasound imaging, provided good "scar" volume quantification. When tested on 10 "scars" of different size and shape, PM resulted in lower bias (-9.7 vs 54.2 mm3) and narrower limits of agreement (-168.6 to 149.2 mm3 vs -296.0 to 404.4 mm3, P = .03). The interobserver variability for "scar" volume was better with PM (intraclass correlation coefficient = 0.901 vs 0.815). Two-dimensional and three-dimensional echocardiography with PM and SP was performed on 15 individuals with myocardial scar secondary to infarction. The CR was higher on PM imaging. Using cardiac magnetic resonance as a reference, quantification of myocardial scar volume showed better agreement when PM was used (bias, -645 mm3; limits of agreement, -3,158 to 1,868 mm3) as opposed to SP (bias, -1,138 mm3; limits of agreement, -5,510 to 3,233 mm3). CONCLUSIONS: The PM modality increased the CR between tissues with different acoustic properties in an experimental in vitro "scar" model while allowing accurate quantification of "scar" volume. By applying the in vitro findings to humans, PM resulted in higher CR between scarred and healthy myocardium, providing better scar volume quantification than SP compared with cardiac magnetic resonance.


Subject(s)
Cicatrix , Echocardiography, Three-Dimensional , Animals , Cattle , Cicatrix/diagnostic imaging , Contrast Media , Heart , Humans , Magnetic Resonance Imaging , Myocardium/pathology
8.
Front Cardiovasc Med ; 8: 632302, 2021.
Article in English | MEDLINE | ID: mdl-33763459

ABSTRACT

Background: Right atrial pressure (RAP) can be estimated by echocardiography from inferior vena cava diameter and collapsibility (eRAPIVC), tricuspid E/e' ratio ( eRAP E / e ' ), or hepatic vein flow (eRAPHV). The mean of these estimates (eRAPmean) might be more accurate than single assessments. Methods and Results: eRAPIVC, eRAP E / e ' , eRAPHV (categorized in 5, 10, 15, or 20 mmHg), eRAPmean (continuous values) and invasive RAP (iRAP) were obtained in 43 consecutive patients undergoing right heart catheterization [median age 69 (58-75) years, 49% males]. There was a positive correlation between eRAPmean and iRAP (Spearman test r = 0.66, P < 0.001), with Bland-Altman test showing the best agreement for values <10 mmHg. There was also a trend for decreased concordance between eRAPIVC, eRAP E / e ' , eRAPHV, and iRAP across the 5- to 20-mmHg categories, and iRAP was significantly different from eRAP E / e ' and eRAPHV for the 20-mmHg category (Wilcoxon signed-rank test P = 0.02 and P < 0.001, respectively). The areas under the curve in predicting iRAP were nonsignificantly better for eRAPmean than for eRAPIVC at both 5-mmHg [0.64, 95% confidence interval (CI) 0.49-0.80 vs. 0.70, 95% CI 0.53-0.87; Wald test P = 0.41] and 10-mmHg (0.76, 95% CI 0.60-0.92 vs. 0.81, 95% CI 0.67-0.96; P = 0.43) thresholds. Conclusions: Our data suggest that multiparametric eRAPmean does not provide advantage over eRAPIVC, despite being more complex and time-consuming.

12.
Rambam Maimonides Med J ; 11(3)2020 Jul 31.
Article in English | MEDLINE | ID: mdl-32792048

ABSTRACT

The outbreak of coronavirus disease 2019 (COVID-19) in Italy, the first Western country hit by the pandemic, seriously impacted the Italian healthcare system and social and economic environment. This perspective piece focuses on the main challenges faced by Italian hospital managements: hospital overcrowding; the need for urgent reorganization of the country's healthcare systems; the lack of data regarding COVID-19 diagnostics, clinical course, and effective treatment; individual and collective consequences of the crisis; and the importance of disease containment measures and early treatment strategies.

15.
Echocardiography ; 35(5): 747-749, 2018 05.
Article in English | MEDLINE | ID: mdl-29509971

ABSTRACT

Contrast echocardiography with agitated saline is used to assess mainly the existence of interatrial communication. We report a case of a 26-year-old woman, with a "port-a-cath" central venous line, who had an unusual finding in agitated saline contrast echocardiography. Multimodality imaging revealed occlusion of superior vena cava and a systemic-to-pulmonary venous shunt.


Subject(s)
Echocardiography/methods , Heart Septal Defects, Atrial/diagnosis , Pulmonary Veins/diagnostic imaging , Sodium Chloride/pharmacology , Vena Cava, Superior/diagnostic imaging , Adult , Female , Humans , Pulmonary Veins/abnormalities , Vena Cava, Superior/abnormalities
16.
Echocardiography ; 34(11): 1740-1741, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28736811

ABSTRACT

We present the case of a 34-year-old female who was admitted to our hospital due to community-acquired pneumonia and had a transthoracic echocardiogram which revealed an aneurysm of the membranous interventricular septum. This was further investigated with a transesophageal echocardiogram which showed in detail the anatomical features of this very rare condition.


Subject(s)
Echocardiography/methods , Heart Aneurysm/diagnostic imaging , Incidental Findings , Ventricular Septum/diagnostic imaging , Adult , Echocardiography, Transesophageal , Female , Humans
18.
G Ital Cardiol (Rome) ; 14(11): 736-45, 2013 Nov.
Article in Italian | MEDLINE | ID: mdl-24326636

ABSTRACT

Atrial fibrillation is the most common arrhythmia in clinical practice. Although postoperative atrial fibrillation occurs in a small percentage of the total number of cases, it is associated with increased mortality, longer hospital stay and higher hospitalization costs, making this issue of particular relevance. The aim of this literature review is to describe the risk profile of this patient subset and to focus on the current knowledge of available prophylactic and therapeutic strategies.


Subject(s)
Atrial Fibrillation/etiology , Surgical Procedures, Operative/adverse effects , Atrial Fibrillation/therapy , Causality , Decision Trees , Humans
19.
Thromb Haemost ; 110(4): 706-22, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23803753

ABSTRACT

Several studies have been carried out on vulnerable plaque as the main culprit for ischaemic cardiac events. Historically, the most important diagnostic technique for studying coronary atherosclerotic disease was to determine the residual luminal diameter by angiographic measurement of the stenosis. However, it has become clear that vulnerable plaque rupture as well as thrombosis, rather than stenosis, triggers most acute ischaemic events and that the quantification of risk based merely on severity of the arterial stenosis is not sufficient. In the last decades, substantial progresses have been made on optimisation of techniques detecting the arterial wall morphology, plaque composition and inflammation. To date, the use of a single technique is not recommended to precisely identify the progression of the atherosclerotic process in human beings. In contrast, the integration of data that can be derived from multiple methods might improve our knowledge about plaque destabilisation. The aim of this narrative review is to update evidence on the accuracy of the currently available non-invasive and invasive imaging techniques in identifying components and morphologic characteristics associated with coronary plaque vulnerability.


Subject(s)
Aortic Rupture/prevention & control , Coronary Vessels/pathology , Diagnostic Imaging/methods , Plaque, Atherosclerotic/diagnosis , Animals , Aortic Rupture/etiology , Coronary Angiography , Diagnostic Imaging/statistics & numerical data , Humans , Plaque, Atherosclerotic/complications