1.
Gut ; 73(4): 613-621, 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38182137

ABSTRACT

OBJECTIVE: Contaminated duodenoscopes caused several hospital outbreaks. Despite efforts to reduce contamination rates, 15% of patient-ready duodenoscopes are still contaminated with gastrointestinal microorganisms. This study aimed to provide an overview of duodenoscope contamination over time, identify risk factors and study the effects of implemented interventions. DESIGN: Duodenoscope culture sets between March 2015 and June 2022 at a Dutch tertiary care centre were analysed. Contamination was defined as (1) the presence of microorganisms of oral or gastrointestinal origin (MGO) or (2) any other microorganism with ≥20 colony-forming units/20 mL (AM20). A logistic mixed effects model was used to identify risk factors and assess the effect of interventions, such as using duodenoscopes with disposable caps, replacing automated endoscope reprocessors (AER) and conducting audits in the endoscopy department. RESULTS: A total of 404 culture sets were analysed. The yearly contamination rate with MGO showed great variation, ranging from 14.3% to 47.5%. Contamination with AM20 increased up to 94.7% by 2022. For both MGO and AM20, the biopsy and suction channels were the most frequently contaminated duodenoscope components. The studied interventions, including audits, AER replacement and implementation of duodenoscopes with disposable caps, did not show a clear association with contamination rates. CONCLUSION: Duodenoscope contamination remains a significant problem, with high contamination rates despite several interventions. Reprocessing the biopsy and suction channels is especially challenging. Changes in the design of reusable duodenoscopes, such as enabling sterilisation or easily replaceable channels, are necessary to facilitate effective duodenoscope reprocessing and to eliminate the risk of duodenoscope-associated infections.


Subject(s)
Cross Infection , Duodenoscopes , Humans , Cholangiopancreatography, Endoscopic Retrograde , Cross Infection/prevention & control , Cross Infection/epidemiology , Magnesium Oxide , Retrospective Studies , Tertiary Care Centers
2.
Endoscopy ; 56(3): 198-204, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37848074

ABSTRACT

BACKGROUND: Current duodenoscope reprocessing protocols are insufficient to prevent contamination and require adaptations to prevent endoscopy-associated infections (EAIs). This study aimed to investigate the effect of a new endoscope cleaning brush on the contamination rate of ready-to-use duodenoscopes. METHODS: This retrospective before-and-after intervention study collected duodenoscope surveillance culture results from March 2018 to June 2022. Contamination was defined as ≥1 colony-forming unit of a microorganism of gut or oral origin (MGO). In December 2020, an endoscope cleaning brush with a sweeper design was introduced as an intervention in the manual cleaning of duodenoscopes. A logistic mixed-effects model was used to study the effects of this intervention. RESULTS: Data were collected from 176 culture sets before the new brush's introduction and 81 culture sets afterwards. Pre-introduction, culture sets positive with an MGO comprised 45.5% (95%CI 38.3%-52.8%; 80/176), decreasing to 17.3% (95%CI 10.6%-26.9%; 14/81) after implementation of the new brush. Compared with the former brush, duodenoscopes cleaned with the new brush had lower odds of contamination with MGOs (adjusted odds ratio 0.25, 95%CI 0.11-0.58; P=0.001) CONCLUSIONS: Use of the new brush in manual cleaning reduced contamination with MGOs and is expected to prevent EAIs. These findings should be confirmed in future prospective randomized studies.


Subject(s)
Duodenoscopes , Magnesium Oxide , Humans , Retrospective Studies , Disinfection/methods , Equipment Contamination/prevention & control , Endoscopy, Gastrointestinal