1.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(7): 711-718, 2022 Jul 20.
Article in Japanese | MEDLINE | ID: mdl-35675976

ABSTRACT

PURPOSE: To validate the effects of changing the source-to-image receptor distance (SID) parameter of scattered X-ray correction after exposure on the image quality in portable chest radiography. METHODS: The actual SID and tube current-time product (mAs) were varied such that the direct X-ray dose to a flat panel detector (FPD) remained constant. We created two groups as follows: Group A (with the SID parameter unchanged) and Group B (with the SID parameter changed to the actual SID after a phantom chest exposure). The image contrast ratio and standard deviation (SD) were measured on the chest radiographs for physical assessment. Observer studies were performed by seven radiological technologists. Scheffé's (Ura) paired comparison methods were performed with image contrast, noise, and overall assessment as the assessment items. Receiver operating characteristic (ROC) analysis for lung nodules was performed. RESULTS: The image contrast ratio and SD in Group A changed, whereas the changes in Group B were less than those in Group A for both these properties. The observer study with Scheffé's methods showed a statistically significant difference (p<0.05) for all assessment items in Group A but not in Group B. The ROC analysis did not indicate any statistically significant differences in either group. CONCLUSION: Changing the SID parameter of scattered X-ray correction after exposure can possibly maintain image contrast and noise in portable chest radiography if the actual SID changes.


Subject(s)
Radiography, Thoracic , Humans , Phantoms, Imaging , Radiographic Image Enhancement/methods , Radiography , X-Rays
2.
Article in Japanese | MEDLINE | ID: mdl-28931770

ABSTRACT

PURPOSE: Spatial normalization is a significant image pre-processing operation in statistical parametric mapping (SPM) analysis. The purpose of this study was to clarify the optimal method of spatial normalization for improving diagnostic accuracy in SPM analysis of arterial spin-labeling (ASL) perfusion images. METHODS: We evaluated the SPM results of five spatial normalization methods obtained by comparing patients with Alzheimer's disease or normal pressure hydrocephalus complicated with dementia and cognitively healthy subjects. We used the following methods: 3DT1-conventional based on spatial normalization using anatomical images; 3DT1-DARTEL based on spatial normalization with DARTEL using anatomical images; 3DT1-conventional template and 3DT1-DARTEL template, created by averaging cognitively healthy subjects spatially normalized using the above methods; and ASL-DARTEL template created by averaging cognitively healthy subjects spatially normalized with DARTEL using ASL images only. RESULTS: Our results showed that ASL-DARTEL template was small compared with the other two templates. Our SPM results obtained with ASL-DARTEL template method were inaccurate. Also, there were no significant differences between 3DT1-conventional and 3DT1-DARTEL template methods. In contrast, the 3DT1-DARTEL method showed higher detection sensitivity, and precise anatomical location. CONCLUSIONS: Our SPM results suggest that we should perform spatial normalization with DARTEL using anatomical images.


Subject(s)
Magnetic Resonance Imaging/methods , Aged , Aged, 80 and over , Female , Gray Matter/diagnostic imaging , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Spin Labels