Comput Methods Programs Biomed ; 136: 143-50, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27686711

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) can cause the formation of blood clots in the heart. The clots may move to the brain and cause a stroke. Therefore, this study analyzed the ECG features of AF and normal sinus rhythm signals for AF recognition which were extracted by using a second-order dynamic system (SODS) concept. OBJECTIVE: To find the appropriate windowing length for feature extraction based on SODS and to determine a machine learning method that could provide higher accuracy in recognizing AF. METHOD: ECG features were extracted based on a dynamic system (DS) that uses a second-order differential equation to describe the short-term behavior of ECG signals according to the natural frequency (ω), damping coefficient, (ξ), and forcing input (u). The extracted features were windowed into 2, 3, 4, 6, 8, and 10 second episodes to find the appropriate windowing size for AF signal processing. ANOVA and t-tests were used to determine the significant features. In addition, pattern recognition machine learning methods (an artificial neural network (ANN) and a support vector machine (SVM)) with k-fold cross validation (k-CV) were used to develop the ECG recognition system. RESULTS: Significant differences (p < 0.0001) were observed among all ECG groups (NSR, N, AF) using 2, 3, 4 and 6 second episodes for the features ω and u/ω; 4, 6 and 8 second episodes for features ω and u; 4 and 6 second episodes for features ω, u and u/ω, and; 10 second episodes for the feature ξ. The highest accuracy for AF recognition (AF, NSR) using ANN with k-CV was 95.3% using combination of features (ω and u; ω, u and u/ω) and SVM with k-CV was 95.0% using a combination of features ω, u and u/ω. CONCLUSION: This study found that 4 s is the most appropriate windowing length, using two features (ω and u) for AF detection with an accuracy of 95.3%. Moreover, the pattern recognition learning machine uses an ANN with 10-fold cross validation based on DS.


Subject(s)
Atrial Fibrillation/diagnosis , Electrocardiography/methods , Atrial Fibrillation/physiopathology , Humans , Models, Theoretical
2.
Int J Cardiol ; 222: 504-508, 2016 Nov 01.
Article in English | MEDLINE | ID: mdl-27505342

ABSTRACT

BACKGROUND: The feasibility study of the natural frequency (ω) obtained from a second-order dynamic system applied to an ECG signal was discovered recently. The heart rate for different ECG signals generates different ω values. The heart rate variability (HRV) and autonomic nervous system (ANS) have an association to represent cardiovascular variations for each individual. This study further analyzed the ω for different ECG signals with HRV for atrial fibrillation classification. METHODS: This study used the MIT-BIH Normal Sinus Rhythm (nsrdb) and MIT-BIH Atrial Fibrillation (afdb) databases for healthy human (NSR) and atrial fibrillation patient (N and AF) ECG signals, respectively. The extraction of features was based on the dynamic system concept to determine the ω of the ECG signals. There were 35,031 samples used for classification. RESULTS: There were significant differences between the N & NSR, N & AF, and NSR & AF groups as determined by the statistical t-test (p<0.0001). There was a linear separation at 0.4s(-1) for ω of both databases upon using the thresholding method. The feature ω for afdb and nsrdb falls within the high frequency (HF) and above the HF band, respectively. The feature classification between the nsrdb and afdb ECG signals was 96.53% accurate. CONCLUSIONS: This study found that features of the ω of atrial fibrillation patients and healthy humans were associated with the frequency analysis of the ANS during parasympathetic activity. The feature ω is significant for different databases, and the classification between afdb and nsrdb was determined.


Subject(s)
Atrial Fibrillation/classification , Atrial Fibrillation/physiopathology , Autonomic Nervous System/physiology , Databases, Factual/classification , Electrocardiography/classification , Heart Rate/physiology , Atrial Fibrillation/diagnosis , Humans
3.
Brain Res ; 1155: 81-92, 2007 Jun 25.
Article in English | MEDLINE | ID: mdl-17512919

ABSTRACT

To study the effects of external visual stimulation on motor cortex-muscle synchronization, coherence between electroencephalography (EEG) and electromyography (EMG) was measured in normal subjects under Before, Task (visual task: Ignore or Count, or arithmetic task) and After conditions. The control (Before and After) conditions required the subject to maintain first dorsal interosseous muscle contraction without visual stimulation. In the visual task, a random series of visual stimuli were displayed on a screen while the subjects maintained the muscle contraction. The subjects were asked to ignore the stimuli in the Ignore condition and to count certain stimuli in the Count condition. Also, in the arithmetic task, the subjects were asked to perform a simple subtraction. The EEG-EMG coherence found at C(3) site at 13-30 Hz (beta) was increased and sustained in magnitude during the Ignore and Count conditions, respectively. To examine the cause of the change of coherence, changes of EEG and EMG spectral power were computed for each frequency band. There was little change in the EMG spectral power in any frequency bands. While the spectral power of EEG unchanged in the beta band, it significantly increased and decreased in the range of 8-12 Hz and of 31-50 Hz, respectively, for both Ignore and Count conditions, not only at the C(3) site but at various sites as well. These results were in contrast to those obtained for the arithmetic task: the beta band EEG-EMG coherence was attenuated and the EEG spectral power at 4-7 Hz and at 31-50 Hz were significantly increased and decreased, respectively. As a conclusion, the present results are consistent with the idea that the enhanced 8-12 Hz/decreased 31-50 Hz oscillations affect strength of the beta band cortico-muscular synchronization by suppressing the visual processing.


Subject(s)
Cerebral Cortex/physiology , Muscle, Skeletal/physiology , Psychomotor Performance , Visual Perception/physiology , Analysis of Variance , Brain Mapping , Electroencephalography , Electromyography , Humans , Muscle, Skeletal/innervation , Reaction Time