Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med Biol ; 59(17): 4945-59, 2014 Sep 07.
Article in English | MEDLINE | ID: mdl-25109506

ABSTRACT

Geometric accuracy of MRI is one of the main concerns for its use as a sole image modality in precision radiation therapy (RT) planning. In a state-of-the-art scanner, system level geometric distortions are within acceptable levels for precision RT. However, subject-induced B0 inhomogeneity may vary substantially, especially in air-tissue interfaces. Recent studies have shown distortion levels of more than 2 mm near the sinus and ear canal are possible due to subject-induced field inhomogeneity. These distortions can be corrected with the use of accurate B0 inhomogeneity field maps. Most existing methods estimate these field maps from dual gradient-echo (GRE) images acquired at two different echo-times under the assumption that the GRE images are practically undistorted. However distortion that may exist in the GRE images can result in estimated field maps that are distorted in both geometry and intensity, leading to inaccurate correction of clinical images. This work proposes a method for estimating undistorted field maps from GRE acquisitions using an iterative joint estimation technique. The proposed method yields geometrically corrected GRE images and undistorted field maps that can also be used for the correction of images acquired by other sequences. The proposed method is validated through simulation, phantom experiments and applied to patient data. Our simulation results show that our method reduces the root-mean-squared error of the estimated field map from the ground truth by ten-fold compared to the distorted field map. Both the geometric distortion and the intensity corruption (artifact) in the images caused by the B0 field inhomogeneity are corrected almost completely. Our phantom experiment showed improvement in the geometric correction of approximately 1 mm at an air-water interface using the undistorted field map compared to using a distorted field map. The proposed method for undistorted field map estimation can lead to improved geometric distortion correction at air-tissue interfaces, especially in low readout-bandwidth acquisitions, thus making them suitable for clinical use in precision RT without increasing the treatment planning margin.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Artifacts , Humans , Phantoms, Imaging
2.
Nucleosides Nucleotides Nucleic Acids ; 25(9-11): 1159-63, 2006.
Article in English | MEDLINE | ID: mdl-17065082

ABSTRACT

Twenty-six fully sequenced archaeal genomes were searched for genes coding for putative deoxyribonucleoside kinases (dNKs). We identified only 5 human-like thymidine kinase 1 genes (TK1s) and none for non-TK1 kinases. Four TK1s were identified in the Euryarchaea and one was found in the Crenarchaea, while none was found in Nanoarchaeum. The identified TK1s have high identity to Gram-positive bacteria TK1s. The TK1s from archaea, Gram-positive bacteria and eukaryotes share the same common ancestor, while the TK1s from Gram-negative bacteria belong to a less-related subgroup. It seems that a functional deoxyribonucleoside salvage pathway is not crucial for the archaeal cell.


Subject(s)
Archaea/enzymology , Archaeal Proteins/chemistry , Gene Expression Regulation , Thymidine Kinase/biosynthesis , Amino Acid Sequence , Animals , Bacterial Proteins/chemistry , Databases, Genetic , Evolution, Molecular , Humans , Molecular Sequence Data , Phosphotransferases (Alcohol Group Acceptor)/chemistry , Phylogeny , Species Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...