Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Genet Mol Biol ; 46(4): e20230015, 2023.
Article in English | MEDLINE | ID: mdl-38051353

ABSTRACT

A complete genome of the first anellovirus infecting the wild felid Leopardus pardalis (ocelot) and a partial genome were assembled and annotated through high-throughput sequencing protocols followed by Sanger sequencing validation. The full-length virus obtained comprises 2,003 bp, while the partial genome comprises 1,224 bp. Phylogenetic analysis grouped these two sequences in two distinct clusters related to previously described Felidae anelloviruses. The ORF1 of the partial genome was identified as a new species provisionally called Torque teno ocelot virus, with 53.6% identity with its sister lineage. The complete genome was inferred as a new representative of the Torque teno felid virus 3 species, with 73.28% identity to the closest reference. This study expands known virus diversity and the host span of anelloviruses.

2.
Braz. j. med. biol. res ; 49(3): e4435, Mar. 2016. tab
Article in English | LILACS | ID: lil-771935

ABSTRACT

The autonomic nervous system maintains homeostasis, which is the state of balance in the body. That balance can be determined simply and noninvasively by evaluating heart rate variability (HRV). However, independently of autonomic control of the heart, HRV can be influenced by other factors, such as respiratory parameters. Little is known about the relationship between HRV and spirometric indices. In this study, our objective was to determine whether HRV correlates with spirometric indices in adults without cardiopulmonary disease, considering the main confounders (e.g., smoking and physical inactivity). In a sample of 119 asymptomatic adults (age 20-80 years), we evaluated forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1). We evaluated resting HRV indices within a 5-min window in the middle of a 10-min recording period, thereafter analyzing time and frequency domains. To evaluate daily physical activity, we instructed participants to use a triaxial accelerometer for 7 days. Physical inactivity was defined as <150 min/week of moderate to intense physical activity. We found that FVC and FEV1, respectively, correlated significantly with the following aspects of the RR interval: standard deviation of the RR intervals (r =0.31 and 0.35), low-frequency component (r =0.38 and 0.40), and Poincaré plot SD2 (r =0.34 and 0.36). Multivariate regression analysis, adjusted for age, sex, smoking, physical inactivity, and cardiovascular risk, identified the SD2 and dyslipidemia as independent predictors of FVC and FEV1 (R2=0.125 and 0.180, respectively, for both). We conclude that pulmonary function is influenced by autonomic control of cardiovascular function, independently of the main confounders.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Heart Rate/physiology , Lung/physiology , Smoking/physiopathology , Autonomic Nervous System/physiology , Cross-Sectional Studies , Dyslipidemias/physiopathology , Forced Expiratory Volume/physiology , Sedentary Behavior , Spirometry , Vital Capacity/physiology
3.
Braz J Med Biol Res ; 49(3)2016 Mar.
Article in English | MEDLINE | ID: mdl-26840706

ABSTRACT

The autonomic nervous system maintains homeostasis, which is the state of balance in the body. That balance can be determined simply and noninvasively by evaluating heart rate variability (HRV). However, independently of autonomic control of the heart, HRV can be influenced by other factors, such as respiratory parameters. Little is known about the relationship between HRV and spirometric indices. In this study, our objective was to determine whether HRV correlates with spirometric indices in adults without cardiopulmonary disease, considering the main confounders (e.g., smoking and physical inactivity). In a sample of 119 asymptomatic adults (age 20-80 years), we evaluated forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1). We evaluated resting HRV indices within a 5-min window in the middle of a 10-min recording period, thereafter analyzing time and frequency domains. To evaluate daily physical activity, we instructed participants to use a triaxial accelerometer for 7 days. Physical inactivity was defined as <150 min/week of moderate to intense physical activity. We found that FVC and FEV1, respectively, correlated significantly with the following aspects of the RR interval: standard deviation of the RR intervals (r =0.31 and 0.35), low-frequency component (r =0.38 and 0.40), and Poincaré plot SD2 (r =0.34 and 0.36). Multivariate regression analysis, adjusted for age, sex, smoking, physical inactivity, and cardiovascular risk, identified the SD2 and dyslipidemia as independent predictors of FVC and FEV1 (R2=0.125 and 0.180, respectively, for both). We conclude that pulmonary function is influenced by autonomic control of cardiovascular function, independently of the main confounders.


Subject(s)
Heart Rate/physiology , Lung/physiology , Sedentary Behavior , Smoking/physiopathology , Adult , Aged , Aged, 80 and over , Autonomic Nervous System/physiology , Confounding Factors, Epidemiologic , Cross-Sectional Studies , Dyslipidemias/physiopathology , Female , Forced Expiratory Volume/physiology , Humans , Male , Middle Aged , Spirometry , Vital Capacity/physiology
4.
Braz. j. med. biol. res ; 48(4): 349-353, 4/2015. tab, graf
Article in English | LILACS | ID: lil-744356

ABSTRACT

The 6-minute walk test (6MWT) is a simple field test that is widely used in clinical settings to assess functional exercise capacity. However, studies with healthy subjects are scarce. We hypothesized that the 6MWT might be useful to assess exercise capacity in healthy subjects. The purpose of this study was to evaluate 6MWT intensity in middle-aged and older adults, as well as to develop a simple equation to predict oxygen uptake ( V ˙ O 2 ) from the 6-min walk distance (6MWD). Eighty-six participants, 40 men and 46 women, 40-74 years of age and with a mean body mass index of 28±6 kg/m2, performed the 6MWT according to American Thoracic Society guidelines. Physiological responses were evaluated during the 6MWT using a K4b2 Cosmed telemetry gas analyzer. On a different occasion, the subjects performed ramp protocol cardiopulmonary exercise testing (CPET) on a treadmill. Peak V ˙ O 2 in the 6MWT corresponded to 78±13% of the peak V ˙ O 2 during CPET, and the maximum heart rate corresponded to 80±23% of that obtained in CPET. Peak V ˙ O 2 in CPET was adequately predicted by the 6MWD by a linear regression equation: V ˙ O 2 mL·min-1·kg-1 = -2.863 + (0.0563×6MWDm) (R2=0.76). The 6MWT represents a moderate-to-high intensity activity in middle-aged and older adults and proved to be useful for predicting cardiorespiratory fitness in the present study. Our results suggest that the 6MWT may also be useful in asymptomatic individuals, and its use in walk-based conditioning programs should be encouraged.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Exercise Test , Healthy Volunteers , Walking/physiology , Cross-Sectional Studies , Carbon Dioxide/physiology , Oxygen Consumption/physiology , Spirometry , Telemetry , Time Factors
5.
Braz J Med Biol Res ; 48(4): 349-53, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25714888

ABSTRACT

The 6-minute walk test (6MWT) is a simple field test that is widely used in clinical settings to assess functional exercise capacity. However, studies with healthy subjects are scarce. We hypothesized that the 6MWT might be useful to assess exercise capacity in healthy subjects. The purpose of this study was to evaluate 6MWT intensity in middle-aged and older adults, as well as to develop a simple equation to predict oxygen uptake ( V ˙ O 2 ) from the 6-min walk distance (6MWD). Eighty-six participants, 40 men and 46 women, 40-74 years of age and with a mean body mass index of 28±6 kg/m2, performed the 6MWT according to American Thoracic Society guidelines. Physiological responses were evaluated during the 6MWT using a K4b2 Cosmed telemetry gas analyzer. On a different occasion, the subjects performed ramp protocol cardiopulmonary exercise testing (CPET) on a treadmill. Peak V ˙ O 2 in the 6MWT corresponded to 78±13% of the peak V ˙ O 2 during CPET, and the maximum heart rate corresponded to 80±23% of that obtained in CPET. Peak V ˙ O 2 in CPET was adequately predicted by the 6MWD by a linear regression equation: V ˙ O 2 mL·min-1·kg-1 = -2.863 + (0.0563×6MWDm) (R2=0.76). The 6MWT represents a moderate-to-high intensity activity in middle-aged and older adults and proved to be useful for predicting cardiorespiratory fitness in the present study. Our results suggest that the 6MWT may also be useful in asymptomatic individuals, and its use in walk-based conditioning programs should be encouraged.


Subject(s)
Exercise Test , Healthy Volunteers , Walking/physiology , Adult , Aged , Carbon Dioxide/physiology , Cross-Sectional Studies , Female , Humans , Male , Middle Aged , Oxygen Consumption/physiology , Spirometry , Telemetry , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...