Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Cancer Med ; 10(8): 2855-2864, 2021 04.
Article in English | MEDLINE | ID: mdl-33314646

ABSTRACT

BACKGROUND: Real-world data for patients with positive colorectal cancer (CRC) screening stool-tests demonstrate that adenoma detection rates are lower when endoscopists are blinded to the stool-test results. This suggests adenoma sensitivity may be lower for screening colonoscopy than for follow-up to a known positive stool-based test. Previous CRC microsimulation models assume identical sensitivities between screening and follow-up colonoscopies after positive stool-tests. The Colorectal Cancer and Adenoma Incidence and Mortality Microsimulation Model (CRC-AIM) was used to explore the impact on screening outcomes when assuming different adenoma sensitivity between screening and combined follow-up/surveillance colonoscopies. METHODS: Modeled screening strategies included colonoscopy every 10 years, triennial multitarget stool DNA (mt-sDNA), or annual fecal immunochemical test (FIT) from 50 to 75 years. Outcomes were reported per 1000 individuals without diagnosed CRC at age 40. Base-case adenoma sensitivity values were identical for screening and follow-up/surveillance colonoscopies. Ranges of adenoma sensitivity values for colonoscopy performance were developed using different slopes of odds ratio adjustments and were designated as small, medium, or large impact scenarios. RESULTS: As the differences in adenoma sensitivity for screening versus follow-up/surveillance colonoscopies became greater, life-years gained (LYG) and reductions in CRC-related incidence and mortality versus no screening increased for mt-sDNA and FIT and decreased for screening colonoscopy. The LYG relative to screening colonoscopy reached >90% with FIT in the base-case scenario and with mt-sDNA in a "medium impact" scenario. CONCLUSIONS: Assuming identical adenoma sensitivities for screening and follow-up/surveillance colonoscopies underestimate the potential benefits of stool-based screening strategies.


Subject(s)
Adenoma/diagnosis , Adenoma/epidemiology , Colonoscopy , Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/epidemiology , Adenoma/mortality , Colorectal Neoplasms/mortality , Follow-Up Studies , Humans , Incidence , Mass Screening/methods , Models, Theoretical , Quality-Adjusted Life Years , Sensitivity and Specificity
2.
PLoS One ; 15(12): e0244431, 2020.
Article in English | MEDLINE | ID: mdl-33373409

ABSTRACT

BACKGROUND: Real-world adherence to colorectal cancer (CRC) screening strategies is imperfect. The CRC-AIM microsimulation model was used to estimate the impact of imperfect adherence on the relative benefits and burdens of guideline-endorsed, stool-based screening strategies. METHODS: Predicted outcomes of multi-target stool DNA (mt-sDNA), fecal immunochemical tests (FIT), and high-sensitivity guaiac-based fecal occult blood tests (HSgFOBT) were simulated for 40-year-olds free of diagnosed CRC. For robustness, imperfect adherence was incorporated in multiple ways and with extensive sensitivity analysis. Analysis 1 assumed adherence from 0%-100%, in 10% increments. Analysis 2 longitudinally applied real-world first-round differential adherence rates (base-case imperfect rates = 40% annual FIT vs 34% annual HSgFOBT vs 70% triennial mt-sDNA). Analysis 3 randomly assigned individuals to receive 1, 5, or 9 lifetime (9 = 100% adherence) mt-sDNA tests and 1, 5, or 9 to 26 (26 = 100% adherence) FIT tests. Outcomes are reported per 1000 individuals compared with no screening. RESULTS: Each screening strategy decreased CRC incidence and mortality versus no screening. In individuals screened between ages 50-75 and adherence ranging from 10%a-100%, the life-years gained (LYG) for triennial mt-sDNA ranged from 133.1-300.0, for annual FIT from 96.3-318.1, and for annual HSgFOBT from 99.8-320.6. At base-case imperfect adherence rates, mt-sDNA resulted in 19.1% more LYG versus FIT, 25.4% more LYG versus HSgFOBT, and generally had preferable efficiency ratios while offering the most LYG. Completion of at least 21 FIT tests is needed to reach approximately the same LYG achieved with 9 mt-sDNA tests. CONCLUSIONS: Adherence assumptions affect the conclusions of CRC screening microsimulations that are used to inform CRC screening guidelines. LYG from FIT and HSgFOBT are more sensitive to changes in adherence assumptions than mt-sDNA because they require more tests be completed for equivalent benefit. At imperfect adherence rates, mt-sDNA provides more LYG than FIT or HSgFOBT at an acceptable tradeoff in screening burden.


Subject(s)
Colorectal Neoplasms/diagnosis , Colorectal Neoplasms/epidemiology , DNA/analysis , Early Detection of Cancer/methods , Aged , Aged, 80 and over , Colorectal Neoplasms/genetics , Female , Guideline Adherence , Humans , Incidence , Longitudinal Studies , Male , Middle Aged , Models, Theoretical , Mortality , Occult Blood , Practice Guidelines as Topic
SELECTION OF CITATIONS
SEARCH DETAIL
...