Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Cataract Refract Surg ; 50(5): 492-497, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38237070

ABSTRACT

PURPOSE: To investigate the difference between the segmented axial length (AL) and the composite AL on a swept-source optical coherence tomography biometer and to evaluate the subsequent effects on artificial intelligence intraocular lens (IOL) power calculations: the Kane and Hill-RBF 3.0 formulas compared with established vergence formulas. SETTING: National Hospital Organization, Tokyo Medical Center, Japan. DESIGN: Retrospective case series. METHODS: Consecutive patients undergoing cataract surgery with a single-piece IOL were reviewed. The prediction accuracy of the Barrett Universal II, Haigis, Hill-RBF 3.0, Hoffer Q, Holladay 1, Kane, and SRK/T formulas based on 2 ALs were compared for each formula. The heteroscedastic test was used with the SD of prediction errors as the endpoint for formula performance. RESULTS: The study included 145 eyes of 145 patients. The segmented AL (24.83 ± 1.89) was significantly shorter than the composite AL (24.88 ± 1.96, P < .001). Bland-Altman analysis revealed a negative proportional bias for the differences between the segmented AL and the composite AL. The SD values obtained by Hoffer Q, Holladay 1, and SRK/T formulas based on the segmented AL (0.52 diopters [D], 0.54 D, and 0.50 D, respectively) were significantly lower than those based on the composite AL (0.57 D, 0.60 D, and 0.52 D, respectively, P < .01). CONCLUSIONS: The segmented ALs were longer in short eyes and shorter in long eyes than the composite ALs. The refractive accuracy can be improved in the Hoffer Q, Holladay 1, and SRK/T formulas by changing the composite ALs to the segmented ALs.


Subject(s)
Axial Length, Eye , Biometry , Lenses, Intraocular , Optics and Photonics , Phacoemulsification , Refraction, Ocular , Tomography, Optical Coherence , Humans , Axial Length, Eye/pathology , Axial Length, Eye/diagnostic imaging , Retrospective Studies , Biometry/methods , Male , Female , Tomography, Optical Coherence/methods , Refraction, Ocular/physiology , Lens Implantation, Intraocular , Aged , Middle Aged , Aged, 80 and over , Visual Acuity/physiology , Pseudophakia/physiopathology
2.
J Clin Med ; 12(22)2023 Nov 07.
Article in English | MEDLINE | ID: mdl-38002573

ABSTRACT

PURPOSE: To evaluate the performance of traditional vergence formulas with segmented axial length (AL) compared to traditional composite AL in extremely long eyes, and to determine whether the segmented AL can be extended to the new-generation formulas, including the Barrett Universal II, Emmetropia Verifying Optical 2.0 (EVO2), Hill-RBF 3.0 (Hill3), Kane, and Ladas Super formula (LSF) formulas in extremely long eyes. SETTING: National Hospital. Organization, Tokyo Medical Center, Japan. DESIGN: Retrospective case series. METHODS: Consecutive patients who underwent uncomplicated cataract surgery implanted with a three-piece intraocular lens between December 2015 and March 2021 were retrospectively reviewed. The composite AL was measured with a swept-source optical coherence tomography (SS-OCT) biometer using a mean refractive index. The segmented AL was calculated by summing the geometric lengths of the ocular segments (cornea, aqueous, lens, and vitreous) using multiple specific refractive indices based on the data obtained by the SS-OCT-based biometer. When refraction was measured at three months postoperatively, the median absolute errors (MedAEs) were calculated with two ALs for each formula. RESULTS: The study included 31 eyes of 22 patients. The segmented AL (30.45 ± 1.23 mm) was significantly shorter than the composite AL (30.71 ± 1.28 mm, p < 0.001). The MedAEs were significantly reduced when using segmented AL for SRK/T, Haigis, Hill3, and LSF, compared to those obtained using composite AL (0.38 vs. 0.62, 0.48 vs. 0.79, 0.50 vs. 0.90, 0.34 vs. 0.61, p < 0.001 for all formulas, respectively). On the contrary, the MedAE obtained by Kane with segmented AL was significantly worse compared to the one with composite AL (0.35 vs. 0.27, p = 0.03). CONCLUSION: In extremely high myopic eyes, the segmented AL improves the performance of SRK/T, Haigis, Hill3, and LSF formulas compared to the composite AL, while the segmented AL worsens the prediction accuracy of the Kane formula.