Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 619
Filter
1.
Rev Sci Instrum ; 95(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38511995

ABSTRACT

To keep the tritium breeding rate TBR > 1 and to meet the high heat load and neutron shielding requirements for the first wall and divertor in fusion demonstration (DEMO) reactors, the number of port plugs and other openings must be limited. To accomplish this, it is necessary to develop alternatives to the use of infrared (IR) thermography to determine the peak heat flux and the heat flux profile onto divertor targets. A divertor tile equipped with multiple temperature monitoring channels can be used to reproduce the temperature profile. To avoid the high temperatures and high neutron flux environment in a DEMO, the monitoring positions can be set well away from the irradiated surface. However, the spatial resolution of this method is lower than that provided by IR thermography. In the present work, we apply two-dimensional temperature response functions and the corresponding heat conduction model to temperature data obtained from a divertor tile surface in the large helical device to study the effects of the spatial resolution of the monitored temperature profile on the reconstructed heat flux profile. The findings provide information that will be useful in defining a method for embedding thermocouples into the divertor tiles of future DEMO reactors.

3.
Rev Sci Instrum ; 94(6)2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37862490

ABSTRACT

Fast ions play a crucial role in plasma heating, and their behavior in the plasma must be accurately understood. A diagnostics method based on charge exchange emission from the n = 4 - 3 transition (λ0 = 468.6 nm) of energetic 3He produced by the deuteron-deuteron reaction has been proposed as a for fast deuterons with energies in the order of MeV. The proposed method has the following advantages: No beam emission interferes with the spectra, the direction of the measuring line of sight, and the injection angle of the diagnostic beam can be freely determined. In previous studies, due to competing bremsstrahlung, it was expected that the proposed method will not be practical in the case of high electron density operation. This paper makes the proposed method available for measurement even at high electron densities by optimizing the measurement line of sight direction and the diagnostic beam incidence angle. This allows an electron density five times larger than the range of applications shown in previous studies. This result will contribute to measure of DT alpha in ITER.

5.
Rev Sci Instrum ; 92(5): 053524, 2021 May 01.
Article in English | MEDLINE | ID: mdl-34243281

ABSTRACT

The fast deuteron (non-Maxwellian component) diagnostic method, which is based on the higher resolution optical spectroscopic measurement, has been developed as a powerful tool. Owing to a decrease in the D-H charge-exchange cross section, the diagnostic ability of conventional optical diagnostic methods should be improved for ∼MeV energy deuterons. Because the 3He-H charge-exchange cross section is much larger than that of D-H in the ∼MeV energy range, the visible light (VIS) spectrum of 3He produced by the dueteron-dueteron (DD) reaction may be a useful tool. Although the density of 3He is small because it is produced via the DD reaction, improvement of the emissivity of the VIS spectrum of 3He can be expected by using a high-energy beam. We evaluate the VIS spectrum of 3He for the cases when a fast deuteron tail is formed and not formed in the ITER-like beam injected deuterium plasma. Even when the beam energy is in the MeV energy range, a large change appears in the half width at half maximum of the VIS spectrum. The emissivity of the VIS spectrum of 3He and the emissivity of bremsstrahlung are compared, and the measurable VIS spectrum is obtained. It is shown that the VIS spectrum of 3He is a useful tool for the MeV beam deuteron tail diagnostics.

13.
QJM ; 111(10): 755, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-29788472
14.
QJM ; 111(10): 741-742, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-29660067
15.
QJM ; 111(9): 661, 2018 Sep 01.
Article in English | MEDLINE | ID: mdl-29554351
16.
Rev Sci Instrum ; 89(2): 024903, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29495814

ABSTRACT

We describe an instrument for the measurement of the Soret and thermodiffusion coefficients in ternary systems based on the transient holographic grating technique, which is called Soret forced Rayleigh scattering (SFRS) or thermal diffusion forced Rayleigh scattering (TDFRS). We integrated the SFRS technique and the two-wavelength detection technique, which enabled us to obtain two different signals to determine the two independent Soret coefficients and thermodiffusion coefficients in ternary systems. The instrument has been designed to read the mass transport simultaneously by two-wavelength lasers with wavelengths of λ = 403 nm and λ = 639 nm. The irradiation time of the probing lasers is controlled to reduce the effect of laser absorption to the sample with dye (quinizarin), which is added to convert the interference pattern of the heating laser of λ = 532 nm to the temperature grating. The result of the measurement of binary benchmark mixtures composed of 1,2,3,4-tetrahydronaphthalene (THN), isobutylbenzene (IBB), and n-dodecane (nC12) shows that the simultaneous two-wavelength observation of the Soret effect and the mass diffusion are adequately performed. To evaluate performance in the measurement of ternary systems, we carried out experiments on the ternary benchmark mixtures of THN/IBB/nC12 with the mass fractions of 0.800/0.100/0.100 at a temperature of 298.2 K. The Soret coefficient and thermodiffusion coefficient agreed with the ternary benchmark values within the range of the standard uncertainties (23% for the Soret coefficient of THN and 30% for the thermodiffusion coefficient of THN).

17.
QJM ; 111(6): 415, 2018 Jun 01.
Article in English | MEDLINE | ID: mdl-29309645
18.
QJM ; 111(7): 483, 2018 Jul 01.
Article in English | MEDLINE | ID: mdl-29346660
19.
QJM ; 111(6): 423, 2018 Jun 01.
Article in English | MEDLINE | ID: mdl-29346680
20.
QJM ; 111(5): 351, 2018 05 01.
Article in English | MEDLINE | ID: mdl-29161438
SELECTION OF CITATIONS
SEARCH DETAIL
...