Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Cataract Refract Surg ; 31(5): 895-902, 2005 May.
Article in English | MEDLINE | ID: mdl-15975453

ABSTRACT

PURPOSE: To prospectively assess the clinical outcome after implantation of the 1CU accommodating intraocular lens (IOL) and a foldable acrylic IOL (AcrySof, Alcon). SETTING: Department of Ophthalmology, Tokyo Dental College, Ichikawa Hospital, Ichikawa, and Minami Aoyama Eye Clinics, Tokyo, Yokohama, Japan. METHODS: Twenty-two eyes of 16 patients with cataract had phacoemulsification implantation of 1CU accommodating IOL. Twenty eyes of 10 age-matched and sex-matched patients with cataract had the same surgery but with a foldable acrylic IOL. All patients had assessments of the amplitude of accommodation, refraction, uncorrected and best corrected distance and near visual acuity, and distance corrected near visual acuity before surgery up to 12 months after surgery. Contrast visual acuities were measured 1 year after surgery. Anterior segment photography, intraocular pressure measurements, specular microscopy, and computerized topography were also performed. RESULTS: The final best corrected distance visual acuity was above 20/25 in all eyes with the 1CU and the AcrySof IOLs. The mean distance corrected near visual acuity was significantly higher in the 1CU IOL group than in the acrylic IOL group after 3 months. None of the eyes with the AcrySof IOL implants displayed an accommodative response at any examination. The peak mean amplitude of accommodation with the 1CU IOLs was observed at 3 months and was 0.5 diopters +/- 0.44 (SD). Accommodation amplitude declined after 6 months. CONCLUSION: The 1CU IOL provided additional near acuity postoperatively, but the benefit disappeared at 12 months with a concomitant decrease in accommodation amplitude owing to an increase in anterior and posterior capsular opacities.


Subject(s)
Accommodation, Ocular , Lens Implantation, Intraocular , Lenses, Intraocular , Phacoemulsification , Visual Acuity/physiology , Acrylic Resins , Aged , Cell Count , Corneal Topography , Endothelium, Corneal/pathology , Female , Humans , Intraocular Pressure , Lens Capsule, Crystalline/pathology , Male , Middle Aged , Postoperative Complications/pathology , Prospective Studies , Prosthesis Design , Treatment Outcome
2.
J Cataract Refract Surg ; 30(3): 558-65, 2004 Mar.
Article in English | MEDLINE | ID: mdl-15050249

ABSTRACT

PURPOSE: To prospectively assess the clinical and visual outcomes of phacoemulsification and implantation of a rollable intraocular lens (IOL) with a thin optic and compare the results with those of implantation of a foldable acrylic IOL. SETTING: Department of Ophthalmology, Tokyo Dental College, Ichikawa General Hospital, Ichikawa, Chiba, Japan. METHODS: Sixteen consecutive eyes of 8 patients (4 women, 4 men) with corticonuclear cataract had small-incision clear corneal phacoemulsification with implantation of a rollable ThinOptX IOL (ThinOptX Inc.) in the capsular bag. Twenty eyes of 10 age- and sex-matched patients (5 women, 5 men) with the same diagnosis had phacoemulsification and intracapsular implantation of an AcrySof foldable acrylic IOL (MA60BM, Alcon). The patients' refractive status and uncorrected and best corrected distance visual acuities were assessed preoperatively and 1 week and 1, 3, and 6 months after surgery. The uncorrected and best corrected near acuities were measured before and 6 months after surgery. Contrast visual acuity was measured with variable contrast charts 1, 3, and 6 months after surgery, and the results in the 2 IOL groups were compared. Anterior segment photography, intraocular pressure (IOP) measurement, specular microscopy, and fundoscopy were done before surgery and at 1, 3, and 6 months. RESULTS: The final best corrected distance acuity was better than 20/25 in all eyes with a ThinOptX IOL and 18 eyes (90%) with an AcrySof IOL. The best corrected near acuity was better than 20/40 in 12 eyes (75%) and 14 eyes (70%), respectively. The mean contrast acuity with charts 2 and 3 was significantly higher in the ThinOptX group than in the AcrySof group at all examinations (P<.05). The final mean postoperative induced astigmatism was 0.06 diopter (D) +/- 0.50 (SD) and 0.25 +/- 0.68 D, respectively (P>.05). There were no differences in IOP or corneal endothelial cell density between the 2 groups at any examination. No intraoperative or postoperative complications occurred. CONCLUSIONS: ThinOptX IOL implantation provided best corrected near and distance visual acuities comparable to those provided by the AcrySof IOLs. The significantly higher contrast acuities attained after implantation of the ThinOptX lens may be attributable to its ultrathin properties.


Subject(s)
Lens Implantation, Intraocular/methods , Lenses, Intraocular , Phacoemulsification/methods , Visual Acuity/physiology , Acrylic Resins , Aged , Cell Count , Contrast Sensitivity/physiology , Endothelium, Corneal/cytology , Female , Humans , Intraocular Pressure , Male , Middle Aged , Minimally Invasive Surgical Procedures , Prospective Studies , Prosthesis Design
SELECTION OF CITATIONS
SEARCH DETAIL
...