Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Materials (Basel) ; 17(9)2024 May 01.
Article in English | MEDLINE | ID: mdl-38730936

ABSTRACT

The marginal accuracy of fit between prosthetic restorations and abutment teeth represents an essential aspect with regard to long-term clinical success. Since the final gap is also influenced by the luting techniques and materials applied, this study analyzed the accuracy of the fit of single-tooth zirconia copings before and after cementation using different luting materials. Forty plaster dies with a corresponding zirconia coping were manufactured based on a single tooth chamfer preparation. The copings were luted on the plaster dies (n = 10 per luting material) with a zinc phosphate (A), glass-ionomer (B), self-adhesive resin (C), or resin-modified glass-ionomer cement (D). The accuracy of fit for each coping was assessed using a non-destructive digital method. Intragroup statistical analysis was conducted using Wilcoxon signed rank tests and intergroup analysis by Kruskal-Wallis and Mann-Whitney U tests (α = 0.05). Accuracy of fit was significantly different before/after cementation within A (0.033/0.110 µm) and B (0.035/0.118 µm; p = 0.002). A had a significantly increased marginal gap compared to C and D, and B compared to C and D (p ≤ 0.001). Significantly increased vertical discrepancies between A and B versus C and D (p < 0.001) were assessed. Of the materials under investigation, the zinc phosphate cement led to increased vertical marginal discrepancies, whereas the self-adhesive resin cement did not influence the restoration fit.

2.
Materials (Basel) ; 17(9)2024 May 06.
Article in English | MEDLINE | ID: mdl-38730967

ABSTRACT

Stress distribution and its magnitude during loading heavily influence the osseointegration of dental implants. Currently, no high-resolution, three-dimensional method of directly measuring these biomechanical processes in the peri-implant bone is available. The aim of this study was to measure the influence of different implant materials on stress distribution in the peri-implant bone. Using the three-dimensional ARAMIS camera system, surface strain in the peri-implant bone area was compared under simulated masticatory forces of 300 N in axial and non-axial directions for titanium implants and zirconia implants. The investigated titanium implants led to a more homogeneous stress distribution than the investigated zirconia implants. Non-axial forces led to greater surface strain on the peri-implant bone than axial forces. Thus, the implant material, implant system, and direction of force could have a significant influence on biomechanical processes and osseointegration within the peri-implant bone.

3.
Clin Oral Investig ; 28(5): 248, 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38602619

ABSTRACT

OBJECTIVES: Fibula free flaps (FFF) are the standard approach to mandibular reconstruction after partial resection, with the goal of restoring aesthetics and masticatory function. The graft position affects both and must be carefully selected. Correlations between sagittal positioning and upper airway anatomy are known from orthognathic surgery. This study aims to evaluate changes in mandibular position and upper airway anatomy after reconstructive surgery with FFF and corresponding correlations. MATERIALS AND METHODS: Mandibular position after reconstruction was evaluated using three-dimensional datasets of pre- and postoperative computed tomography scans of patients treated between 2020 and 2022. Three-dimensional measurements were performed on both condyles and the symphyseal region. Changes in upper airway volume and minimum cross-sectional area (minCSA) were analysed. Intra-rater reliability was assessed. Correlations between changes in upper airway anatomy and sagittal mandibular position were tested. RESULTS: The analysis included 35 patients. Intra-rater reliability was good to excellent. Condylar deviations and rotations were mostly rated as small. Changes in symphyseal position were considerably greater. Median airway volume decreased in the oropharynx and hypopharynx. Posterior deviation of the symphysis was associated with a decreasing minCSA in the hypopharynx and vice versa. CONCLUSIONS: The overall accuracy of mandibular reconstructions with FFF is high, but there is room for optimization. The focus of research should be extended from masticatory to respiratory rehabilitation. CLINICAL RELEVANCE: Effects on respiratory function should be considered prior to graft positioning. The clinical relevance of upper airway changes within the complex rehabilitation of reconstructive surgery patients needs to be further investigated.


Subject(s)
Free Tissue Flaps , Malocclusion , Plastic Surgery Procedures , Humans , Reproducibility of Results , Esthetics, Dental
4.
Dent J (Basel) ; 12(4)2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38668006

ABSTRACT

The implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies. To determine implant position, the generated STL files were imported into the Exocad CAD software and superimposed-automatically and manually-with the scanbody geometries stored within the software's shape library. Position accuracy was determined by a comparison of the 3D-defined scanbody points from the STL matching files with those from the reference STL files. The R statistical software was used for the evaluation of the data. In addition, mixed linear models and a significance level of 0.05 were applied to calculate the p-values. The manual overlay method was significantly more accurate than the automatic overlays for both scanbody types. The Medentika scanbodies showed slightly superior precision compared to the NT-Trading scanbodies. Both scanbody geometry and the type of alignment in the CAD software significantly affect digital workflow accuracy. Manual verification and adjustment of the automatic alignment process are essential for precise implant positioning.

5.
Eur J Dent Educ ; 28(2): 416-429, 2024 May.
Article in English | MEDLINE | ID: mdl-37870966

ABSTRACT

INTRODUCTION: This study aimed to determine whether implant surgery procedures can be implemented in the dental curriculum by designing novel courses for students. Additionally, this study assesses the perception of these courses and how they can be established in the future. MATERIALS AND METHODS: Students from the third to fifth years participated in a programme consisting of 4 modules according to their academic year. The modules taught theoretical and practical content as well as clinical references. After participating, the students completed two questionnaires with research questions (RQ1 = evaluation of the relevance and effects; RQ2 = impact of modules 3 and 4) to evaluate the programme. The questionnaires consisted of 52 statements, each rated on a 6-point scale (1 'totally disagree' to 6 'totally agree'). Cronbach's alpha analysis was used, and median values, interquartile ranges and Pearson correlations (p-value) were statistically calculated. RESULTS: In total, 94 students completed the questionnaires. Cronbach's alpha exceeded 0.7 for all constructs except for one (skills training). The highest evaluated median was 6, and the lowest was 4.75. Pearson correlations were significant (<0.05) for perceived importance/lectures, perceived importance/tutor performance, lectures/skills training, skills training/tutor performance and tutor performance/lectures. Seventeen analysed free comments expressed strong interest in implantology courses for the curriculum. 88% of the students wished for more practical exercises in dental implantology during the curriculum or suggested expanding the programme in the future. CONCLUSION: The programme was highly accepted among dental students. The students wished for more practice in the future to perform supervised procedures on patients.


Subject(s)
Education, Dental , Students, Dental , Humans , Education, Dental/methods , Curriculum , Surveys and Questionnaires , Clinical Competence
6.
Int J Comput Dent ; 0(0): 0, 2023 Oct 12.
Article in English | MEDLINE | ID: mdl-37823543

ABSTRACT

AIM: This randomized controlled clinical study focused on graft volume alterations after sinus floor augmentation with a deproteinized bovine bone mineral (DBBM, Geistlich Bio-Oss®), deproteinized porcine bone mineral (DPBM, THE GRAFT®) or a biphasic calcium phosphate (BCP, OSOPIA®). MATERIAL AND METHODS: 28 patients with edentulous situations in the posterior maxilla with less or equal to 5 mm of residual bone height received a two- staged external sinus grafting procedure with DBBM, DPBM or BCP. CBCT scans were performed prior surgery (CBCT1), directly after surgery (CBCT2) and after a healing period of 4-6 months prior implant placement (CBCT3). CBCT scans were used to analyze volumetric alterations of the sinus grafts by virtual 3D model matching of CBCT1- CBCT2 (situation after sinus grafting) and CBCT1 and CBCT2 (situation prior implant placement). RESULTS: The volume of the bone graft in the maxillary sinus (volume (VOL%) directly after grafting rated as 100%) was stable after the healing period in the DBBM (VOL%: 103±4%) and the PBBM groups (VOL%: 112± 23) with no statistically significant differences concerning 3D measurements. In the BCP group, the grafted volume declined to 66± 25% (VOL%), statistically inferior to the DBBM and DPBM groups. CONCLUSION: Concerning bone graft stability/ 25 volume DBBM and DPBM show comparable outcomes. Due to resorption, BCP showed inferior bone graft volume after healing (statistically significant) compared to DBBM and DPBM.

7.
Dentomaxillofac Radiol ; 52(8): 20230275, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37641962

ABSTRACT

OBJECTIVES: Artefacts from dental implants in three-dimensional (3D) imaging may lead to incorrect representation of anatomical dimensions and impede virtual planning in navigated implantology. The aim of this study was quantitative assessment of artefacts in 3D STL models from cone beam CT (CBCT) and multislice CT (MSCT) using different scanning protocols and titanium-zirconium (Ti-Zr) and zirconium (ZrO2) implant materials. METHODS: Three ZrO2 and three Ti-Zr implants were respectively placed in the mandibles of two fresh human specimens. Before (baseline) and after implant placement, 3D digital imaging scans were performed (10 repetitions per timepoint: voxel size 0.2 mm³ and 0.3 mm³ for CBCT; 80 and 140 kV in MSCT). DICOM data were converted into 3D STL models and evaluated in computer-aided design software. After precise merging of the baseline and post-op models, the surface deviation was calculated, representing the extent of artefacts in the 3D models. RESULTS: Compared with baseline, ZrO2 emitted 36.5-37.3% (±0.6-0.8) artefacts in the CBCT and 39.2-50.2% (±0.5-1.2) in the MSCT models. Ti-Zr implants produced 4.1-7.1% (±0.3-3.0) artefacts in CBCT and 5.4-15.7% (±0.5-1.3) in MSCT. Significantly more artefacts were found in the MSCT vs CBCT models for both implant materials (p < 0.05). Significantly fewer artefacts were visible in the 3D models from scans with higher kilovolts in MSCT and smaller voxel size in CBCT. CONCLUSIONS: Among the four applied protocols, the lowest artefact proportion of ZrO2 and Ti-Zr implants in STL models was observed with CBCT and the 0.3 mm³ voxel size.


Subject(s)
Dental Implants , Zirconium , Humans , Titanium , Artifacts , Cone-Beam Computed Tomography/methods
8.
Sci Rep ; 13(1): 12216, 2023 07 27.
Article in English | MEDLINE | ID: mdl-37500683

ABSTRACT

We aimed to validate the metric accuracy of a 3-dimensional (3D) facial scanner (FS) and an intraoral scanner (IOS) in capturing the nasolabial region in ex vivo unilateral cleft lip and palate (UCLP) models. The nasolabial region of 10 UCLP models was scanned using a 3D FS as well as an IOS and a previously validated stationary 3D scanner as a reference. Intraoral scan was performed directly on the UCLP models. In order to apply the FS on the models, they were embedded in a 3D printed sample face. Both test groups were aligned to the reference by applying a section-based best-fit algorithm. Subsequent analysis of the metric deviation from the reference was performed with a 3D analysis tool. Mean distance and integrated distance served as main parameters for surface and volume comparison. Point comparison served as an additional parameter. Statistical analysis was carried out using t-test for unconnected samples. Considering mean distance and integrated distance as main parameters for 3D evaluation of the scanner's accuracy, FS and IOS differ significantly in their metric precision in scanning the cleft model compared to the reference. The IOS proved to be significantly more accurate than the FS compared to the previously described stationary 3D scanner as reference and validated baseline. Further validation of the tested IOS and FS for 3D assessment of the nasolabial region is presented by adding the previously validated ATOS III Triple Scan blue light scanner as a reference. The IOS shows, compared to a validated baseline scan, significantly higher metric precision in experimental cleft model scanning. The collected data provides a basis for clinical application of the IOS for 3D assessment of the nasolabial region.


Subject(s)
Cleft Lip , Cleft Palate , Humans , Cleft Palate/diagnostic imaging , Cleft Lip/diagnostic imaging , Imaging, Three-Dimensional , Lip , Data Collection , Computer-Aided Design
9.
Clin Exp Dent Res ; 9(2): 368-374, 2023 04.
Article in English | MEDLINE | ID: mdl-36780185

ABSTRACT

OBJECTIVE: In dental restorations, color determination is very important for achieving esthetic results. The aim of this study was to compare visual shade selection using digital methods and to assess the repeatability of the utilized intraoral scanners. MATERIALS AND METHODS: In 31 probands, tooth color was determined on teeth 11, 13, and 16. Shade selection was performed visually by a dentist and digitally using Trios 3 and Cerec Omnicam. Three measurements were performed to determine the repeatability of intraoral scanners. Fleiss' κ was used for statistical evaluation of the repeatability and Cohen's κ was used for comparison of methods. RESULTS: The visual method showed only slight agreement with Trios 3 (Cohen's κ: 0.198) and Cerec Omnicam (Cohen's κ: 0.115). Moderate agreement was found between Trios 3 and Cerec Omnicam (Cohen's κ: 0.452). In terms of repeatability, Trios 3 scored higher overall than Cerec Omnicam (Fleiss' κ: 0.612 vs. 0.474). CONCLUSION: Intraoral scanners can facilitate the workflow in clinical practice. They are a good supplement for color determination, but should additionally be confirmed by the visual method. Clinical significance: The use of digital instruments is increasingly being preferred over conventional treatments. Therefore, it is essential to continuously improve the accuracy of intraoral scanners for color selection in order to offer an alternative to visual methods.


Subject(s)
Cuspid , Prosthesis Coloring , Dietary Supplements
10.
Sci Rep ; 12(1): 22509, 2022 12 29.
Article in English | MEDLINE | ID: mdl-36581668

ABSTRACT

The aim of this study was to compare the trueness of complete- and partial-arch impressions obtained using conventional impression materials and intraoral scanners in vivo. Full-arch impressions were taken using polyether and polyvinylsiloxane. Gypsum casts were digitized using a laboratory scanner (IM, AF). Casts obtained from polyether impressions were also scanned using an industrial blue light scanner to construct 3D reference models. Intraoral scanning was performed using CEREC Omnicam (CO) and Trios 3 (TR). Surface matching software (Atos Professional) enabled to determine the mean deviations (mean distances) from the reference casts. Statistically significant discrepancies were calculated using the Wilcoxon signed-rank test. The mean distance for trueness ranged from 0.005 mm (TR) to 0.023 mm (IM) for the full arch, from 0.001 mm (CO) to 0.068 mm (IM) for the anterior segment, and from 0.019 mm (AF) to 0.042 mm (IM) for the posterior segment. Comparing the anterior vs. the posterior segment, significantly less deviations were observed for anterior with CO (p < 0.001) and TR (p < 0.001). Full-arch comparisons revealed significant differences between AF vs. IM (p = 0.014), IM vs. CO (p = 0.002), and IM vs. TR (p = 0.001). Full-arch trueness was comparable when using Affinis and the two intraoral scanners CEREC Omnicam and Trios 3. The digital impression devices yielded higher local deviations within the complete arch. Digital impressions of the complete arch are a suitable and reliable alternative to conventional impressions. However, they should be used with caution in the posterior region.Trial registration: Registration number at the German Clinical Trial Register (04.02.2022): DRKS00027988 ( https://trialsearch.who.int/ ).


Subject(s)
Imaging, Three-Dimensional , Models, Dental , Computer-Aided Design , Polyvinyls , Dental Impression Technique
11.
BMC Oral Health ; 22(1): 361, 2022 08 23.
Article in English | MEDLINE | ID: mdl-35999531

ABSTRACT

BACKGROUND: In mucogingival and implant surgery, an autologous soft tissue graft from the palate is the gold standard for reconstructing missing keratinised soft tissue and volume. Previously, presurgical measurements of the graft harvesting site were described with two-dimensional (2D) linear measurements. The present observational clinical study aimed to evaluate a three-dimensional (3D) measurement method for determining the present palatal soft tissue volume for each patient individually. METHODS: Pre-existing cone beam computed tomography (CBCT) scans of 20 patients were converted into 3D Standard Tessellation Language models of the bone surface. Intraoral impressions of the maxilla were taken and digitised to visualise the gingival surface. The resulting virtual models of bone (reference value) and gingival (actual value) surfaces were merged, with tooth surfaces used for registration. The region between the central incisors and the hard palate was subdivided into 5 regions of interest (ROIs). The distance between palatal bone and gingival surface was analysed both volumetrically and linearly, and the results were statistically evaluated for the ROIs. RESULTS: The average gingival surface area on the palate was 19.1 cm2, and the mean volume was 58.2 cm3 (± 16.89). Among the ROIs, the mean linear value was highest in the most distal region, from the second molar to the hard palate (4.0 ± 1.09 mm) and lowest in the canine region (1.9 ± 0.63 mm). For mean distance, significant differences were found for the anterior palate and the most posterior palate in comparison with all other ROIs (p < 0.01). The volume measurements also declined significantly and steadily between the posterior (1.9 ± 1.0 cm3) and anterior palates (0.4 ± 0.2 cm3). CONCLUSIONS: By merging digital data, palatal soft tissue could be quantified virtually. The results were reliable and comparable to previous findings with linear measurement methods. This 3D soft tissue volume analysis method fully exploited the diagnostic potential of data that are frequently collected for presurgical planning in oral surgery (i.e., CBCT + surface scans). This evaluation method might be useful for volumetric and linear measurements in other applications in anatomy and for determining palatal soft tissue dimensions in the planning stage before surgical interventions. TRIAL REGISTRATION: This observational clinical trial was retrospectively registered in the German Clinical Trials Register, reference number: DRKS00023918.


Subject(s)
Cone-Beam Computed Tomography , Palate , Cone-Beam Computed Tomography/methods , Maxilla/diagnostic imaging , Molar , Palate/anatomy & histology , Palate/diagnostic imaging , Palate/surgery , Palate, Hard , Workflow
12.
J Prosthet Dent ; 128(5): 994-1000, 2022 Nov.
Article in English | MEDLINE | ID: mdl-33888327

ABSTRACT

STATEMENT OF PROBLEM: Compared with the frequent investigations into the accuracy of digital intraoral scans, studies analyzing digital determinations of jaw relationships based on intraoral scans are scarce. PURPOSE: The purpose of this in vitro study was to present an optical 3-dimensional method for analyzing deviations in static occlusion and to compare the accuracy of conventional and digital interocclusal registrations. MATERIAL AND METHODS: A Frasaco jaw model was duplicated, articulated, and scanned with a high-precision industrial scanner, and the data were stored in a virtual standard tessellation language (STL) format, which served as the reference model. Fifteen paired mandibular and maxillary models were scanned with a digital intraoral scanner in the completely digital workflow (IOS group). Forty-five paired gypsum casts were poured from polyvinyl siloxane (PVS) impressions and associated with 2 different PVS registration materials. These casts were digitized with a laboratory scanner and grouped as follows (n=15/group): PVS group, conventional Futar D interocclusal record; sPVS group, conventional Futar Scan interocclusal record; and the AIR group, partially digital antagonist scan of the Futar Scan interocclusal record. The axes (X, Y, Z, and XYZ) of each paired model were aligned to those of the reference model by 3-dimensional superimposition, and deviations were calculated. To determine the ideal zero position, a best-fit over the mandibular teeth between the reference model and the actual model was estimated. Next, a second best-fit was determined between the maxillary models to determine the actual position of the mandibular model. The different registration methods were compared with the Mann-Whitney U test (α=.05). RESULTS: In the IOS group, the interocclusal registration caused a mandibular deviation of 0.05 ±0.04 mm (mean ±standard deviation). This fit was better than those of conventional registrations with inserted interocclusal registration materials (PVS group and sPVS group), which caused mean z-axis deviations of 0.41 ±0.46 mm and 0.44 ±0.32 mm (P<.001), with the deviations leading to elevation of the mandibular model. The partially digital workflow with a scannable registration material (AIR group) showed significantly larger deviations in the x-axis (0.15 ±0.08 mm; P=.042) compared with the IOS group. No significant difference was observed in the total deviation between the IOS and the AIR groups. Both groups showed significantly smaller deviations than the conventional registration methods (P<.001 for the IOS group and P=.023 for the AIR group). CONCLUSIONS: In comparison with maxillary and mandibular alignment using conventional interocclusal registration materials, digital interocclusal registrations showed greater accuracy in evaluating complete jaw models and can be recommended for clinical use. Additionally, the partially digital workflow with an antagonist scan of the interocclusal record provided acceptable results.


Subject(s)
Dental Impression Technique , Models, Dental , Imaging, Three-Dimensional/methods , Dental Occlusion , Computer-Aided Design
13.
J Oral Rehabil ; 49(1): 71-80, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34717003

ABSTRACT

BACKGROUND: With the constantly increasing demand for metal-free solutions in dental therapy, numerous ceramic restorations have found their way into everyday clinical practice, but long-term clinical data are limited. OBJECTIVE: The aim of this prospective clinical study was to evaluate three- and four-unit fixed partial dentures in the posterior region made of zirconium dioxide frameworks veneered with feldspathic porcelain after 10 years in clinical use. METHODS: Based on the two studies published in 2009 and 2012, in which the all-ceramic FDPs were evaluated after 3 and 5 years of function, a clinical evaluation of a total of 17 restorations after 10 years with regard to their condition and long-term stability was carried out in the course of this study. The restorations were fabricated using feldspathic ceramic-veneered, yttria-stabilised, tetragonal zirconium dioxide as the framework material. The data collection was based on modified CDA criteria and included, for example, the shape, shade, surface condition and the success and survival rates of the restorations. RESULTS: The all-ceramic prostheses embodied excellent biocompatibility and colour reproduction. As a result of an increased incidence of chipping fractures, the success rate was 60%. The survival rate, however, was 88.2%, as 2 of the 17 restorations were lost. CONCLUSION: All-ceramic concepts for FDP constructions in the posterior region achieved satisfactory results in terms of durability after 10 years. The main problem was chipping, as has been generally recognised. Nevertheless, the materials were characterised by excellent aesthetics and biocompatibility, which ultimately makes them a good alternative to conventional restorative options. TRIAL REGISTRATION: This study is registered in DRKS-German Clinical Trials Register with the register number DRKS00021743.


Subject(s)
Esthetics, Dental , Zirconium , Ceramics , Dental Materials , Dental Porcelain , Dental Restoration Failure , Denture, Partial, Fixed , Humans , Prospective Studies
14.
Int J Prosthodont ; 35(6): 801-808, 2022.
Article in English | MEDLINE | ID: mdl-36645864

ABSTRACT

PURPOSE: To evaluate intraoral scanners, scannable impression materials, and conventional methods for impression-taking with regard to precision and accuracy. MATERIALS AND METHODS: Ten impressions per technique were initially taken from a cobalt-chromium (Co-Cr) master model (chamfer preparation for the maxillary right first molar) for fabricating Co-Cr crown copings. The test specimens, their respective metal master model, and the plaster casts from the conventional impressions were then digitized with the light-optical Atos Triple Scanner. The fit of the dental crown copings was measured in two and three dimensions using computer-aided design software. Global differences between the methods were determined using Kruskal-Wallis test, and pairwise comparisons were performed with Mann-Whitney U test. The significance level was set at .05. RESULTS: The 2D analysis showed that the average absolute marginal distance of the crown copings was 0.026 mm when fabricated with the digital impression method and 0.038 mm when fabricated with the conventional method (P = .028). However, the 3D analysis revealed that the conventional group had a smaller marginal gap (0.028 mm) compared to the digital group (0.06 mm; P = .015). CONCLUSION: This study showed that, in the field of single-crown prosthetics, digital impressions and the use of scannable impression material could serve as alternatives to conventional methods in the future.


Subject(s)
Crowns , Dental Impression Technique , Dental Prosthesis Design/methods , Dental Marginal Adaptation , Dental Impression Materials , Computer-Aided Design , Cobalt
15.
Biomater Investig Dent ; 8(1): 119-128, 2021.
Article in English | MEDLINE | ID: mdl-34447944

ABSTRACT

PURPOSE: Here we aimed to compare two machining strategies regarding the marginal strength of CAD/CAM materials using a hoop-strength test in model sphero-cylindrical dental crowns, coupled with finite element analysis. MATERIALS AND METHODS: Five CAD/CAM materials indicated for single posterior crowns were selected, including a lithium disilicate (IPS e.max® CAD), a lithium (di)silicate (Suprinity® PC), a polymer-infiltrated ceramic scaffold (Enamic®), and two indirect resin composites (Grandio® Blocs and Lava™ Ultimate). A sphero-cylindrical model crown was built on CAD Software onto a geometrical abutment and machined using a Cerec MC XL system according to the two available protocols: rough-fast and fine-slow. Specimens were fractured using a novel hoop-strength test and analyzed using the finite element method to obtain the inner marginal strength. Data were evaluated using Weibull statistics. RESULTS: Machining strategy did not affect the marginal strength of any restorative material tested here. Ceramic materials showed a higher density of chippings in the outer margin, but this did not reduce inner marginal strength. IPS e.max® CAD showed the statistically highest marginal strength, and Enamic® and Lava™ Ultimate were the lowest. Grandio® Blocs showed higher performance than Suprinity® PC. CONCLUSIONS: The rough-fast machining strategy available in Cerec MC XL does not degrade the marginal strength of the evaluated CAD/CAD materials when compared to its fine-fast machining strategy. Depending on the material, resin composites have the potential to perform better than some glass-ceramic materials.

16.
J Clin Periodontol ; 48(1): 145-162, 2021 01.
Article in English | MEDLINE | ID: mdl-33047372

ABSTRACT

AIM: This study evaluates the early volumetric changes after buccal soft tissue contour augmentation around implants with a porcine collagen matrix (CM) vs. the subepithelial connective tissue graft (SCTG) from the palate. MATERIALS AND METHODS: 14 patients were enrolled after early implant placement with simultaneous contour augmentation and persistent buccal tissue deficits. At implant exposure, buccal soft tissues were thickened with the CM (n = 7) or the SCTG (n = 7). Impressions were taken before and after surgery, after ten days, one, three and six months. Impressions were digitized and augmented regions 3D evaluated (soft tissue volume (mm3 , %)/thickness (mm)). RESULTS: Volume increase (mm3 ) after 6 months was 19.56 ± 8.95 mm3 (CM) and 61.75 ± 52.69 mm3 (SCTG) (insignificant, p = .058). In percentage, this was a volume loss of the initially augmented soft tissue volume (100%) of 81.76% in the CM group and 56.39% in the SCTG group (6 months). The mean soft tissue thickness increase (mm) in the buccal contour after 6 months was 0.30 ± 0.16 mm (CM) and 0.80 ± 0.61 mm (SCTG) (insignificant, p = .071). CONCLUSION: The early healing phase is associated with a significant volume loss of the soft tissues. The SCTG shows insignificant superiority compared to the CM.


Subject(s)
Dental Implants , Gingiva , Animals , Autografts , Collagen , Connective Tissue , Humans , Swine
17.
BMC Oral Health ; 20(1): 345, 2020 11 30.
Article in English | MEDLINE | ID: mdl-33256686

ABSTRACT

BACKGROUND: The abrasion behavior of various ceramics is rarely investigated, though it is relevant for the clinical success of such restorations. The aim of this in vivo study was to evaluate the wear of feldspathic-ceramic-veneered zirconium oxide frameworks over a period of at least 10 years. METHODS: The abrasion behavior of 15 bridge constructions from 15 different participants was examined after a period of 3, 5, and 10 years using plaster models, which were then subjected to a scanning process on the Atos II industrial scanner and digitized for three-dimensional evaluation of the abrasion by the corresponding software (ATOS Professional 7.6). The individual post-examination models were compared to the baseline model and deviations calculated in the sense of the largest, punctual loss of material in millimeters ("minimal distance"), the average abrasion in millimeters ("mean distance"), and the volume decrease in cubic millimeters ("integrated distance"). Statistical analyses were performed using the Wilcoxon sign rank test or mixed regression models. Multiple testing was considered by Benjamini-Hochberg correction. The significance level was set at 0.05. RESULTS: We found steadily increasing wear of the ceramic. The average volume decrease was significant (P < 0.001) at 3 years and 10 years (- 3.25 mm3 and - 8.11 mm3, respectively). CONCLUSIONS: The results of this study indicate that the rate of volume loss in feldspathic-ceramic-veneered zirconia frameworks in the posterior region increases significantly over time. An increasing frequency of parameters was observed, particularly in the second half of the study period. However, the use of this class of materials can be considered clinically acceptable. Trial registration This study is registered in DRKS - German Clinical Trials Register with the register number DRKS00021743. https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00021743.


Subject(s)
Dental Porcelain , Zirconium , Ceramics , Humans , Materials Testing , Surface Properties
18.
J Dent ; 103: 103500, 2020 12.
Article in English | MEDLINE | ID: mdl-33065218

ABSTRACT

OBJECTIVES: This study's hypothesis was to evaluate differences of the occlusal wear rate for monolithically fabricated lithium disilicate and hand-veneered zirconia crowns in-vivo. Furthermore, a comparison of the materials' clinical performance according to CDA criteria was investigated. METHODS: A total number of 15 patients in the need of full-coverage ceramic fixed dental prosthesis on molars were treated with two crowns each (n = 30), randomly assigned on the contralateral sides made of monolithic IPS e.max CAD (n = 15) and IPS e.max Ceram hand-veneered zirconia (n = 15). Clinical examination was conducted, silicone impressions were taken and plaster models fabricated at the day of crown insertion (baseline) and after 1, 2 and 3 years. The abrasion rate was digitally investigated: after model digitization with the industrial scanner Atos II, each follow-up model was superimposed with the baseline model. The wear was evaluated as the difference between two scans in terms of maximum vertical loss [mm], average decrease [mm] and volume loss [mm³]. For statistical analysis, the Mann-Whitney U test was performed and significance was set to less than 0.05. RESULTS: IPS e.max CAD crowns showed a volume loss of -0.68 mm³ after three years, while IPS e.max Ceram hand-veneered zirconia crowns showed a volumetric wear of -0.75 mm³ at the same point of time. However, no significant differences were found between both materials regarding the 3 evaluated wear parameters. The survival rate for both materials was 100 % and the clinical performance outcome was good to excellent. CONCLUSION: The two investigated materials for ceramic fixed dental prostheses showed similar wear rates and clinical performance over an in-vivo use of 3 years. CLINICAL SIGNIFICANCE: Ceramic restorations are subject to occlusal wear over time due to the natural masticatory process. Both monolithic lithium disilicate and glass-ceramic veneered zirconia copings showed clinically satisfactory results over 3 years in-situ. In terms of abrasion, they are equally well suited for clinical use.


Subject(s)
Tooth Attrition , Ceramics , Computer-Aided Design , Crowns , Dental Porcelain , Dental Prosthesis Design , Humans , Mouth , Zirconium
19.
J Xray Sci Technol ; 28(6): 1141-1155, 2020.
Article in English | MEDLINE | ID: mdl-32804111

ABSTRACT

BACKGROUND/OBJECTIVE: In this retrospective study, we aimed to investigate a new 3D evaluation method for evaluating bone regeneration after cystectomy of odontogenic cysts. METHODS: The study included 26 patients who underwent cystectomies between 2012 and 2017 and had received either fillings or non-fillings with autologous iliac crest. Bony regeneration was analyzed using 3D imaging software and comparing identical regions of interest (ROIs) that were determined by exact overlays of the postoperative cone beam computer tomography (CBCT) or computer tomography (CT) images. Outcome measures, including volume changes according to the defect size and configuration, patient age, the entity and distribution of the cysts, were collected. RESULTS: Twenty-six patients (5 women and 21 men) had 30 defects, including nine keratocysts, seven radicular cysts and 14 dentigerous cysts. A total of 73% of the defects were in the mandible. The mean 3D follow-up time was 12 months. According to the 3D evaluation of bony regeneration, the defect size and configuration showed no significant differences between the groups (filled or non-filled with 15 defects per group). CONCLUSIONS: By establishing a standardized 3D method for evaluating bone regeneration, healing can be better monitored and evaluated.


Subject(s)
Bone Regeneration/physiology , Cystectomy , Imaging, Three-Dimensional/methods , Odontogenic Cysts , Adolescent , Adult , Aged , Aged, 80 and over , Autografts , Cone-Beam Computed Tomography , Female , Humans , Ilium/transplantation , Jaw/diagnostic imaging , Male , Mandibular Diseases/diagnostic imaging , Mandibular Diseases/surgery , Maxillary Diseases/diagnostic imaging , Maxillary Diseases/surgery , Middle Aged , Odontogenic Cysts/diagnostic imaging , Odontogenic Cysts/surgery , Retrospective Studies , Young Adult
20.
J Prosthodont ; 29(4): 309-314, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31802574

ABSTRACT

PURPOSE: Sufficient data are not currently available on how the various geometries of scan bodies and different scan strategies affect the quality of digital impressions of implants. The purpose of this study was to present new data on these two topics and give clinicians a basis for decision making. MATERIALS AND METHODS: A titanium master model containing three Nobelreplace Select™ implants (Nobelbiocare Services AG, Zurich, Switzerland) was digitized using an ATOS industrial noncontact scanner. Digitization was repeated three times with different types of scan bodies integrated into the implants: ELOS A/S, nt-trading GmbH, and TEAMZIEREIS GmbH. These three scans served as virtual master models. The titanium master model was then scanned with the TRIOS3© digital intraoral scanner (ELOS A/S, Copenhagen, Denmark), which was used for two different scanning strategies. Strategy A was a one-step procedure that included both the titanium master model and the integrated scan bodies. Strategy B comprised two steps. First, a digital overlay was performed with a scan of the titanium master model without integrated scan bodies. A second scan was performed with the titanium master model and integrated scan bodies. By repeating both strategies 10 times for each type of scan body, 60 scans were generated and the corresponding standard tessellation language data sets overlaid with the corresponding virtual master model. Deviations in the resulting superimpositions were calculated and evaluated separately in the individual axes (x, y, z) and in three-dimensional space (Euclidean distance). Statistical evaluation was performed using the R-project software. Level of significance was determined at p ≤ 0.05. RESULTS: With regard to the geometry of the scan bodies, strategy A significantly influenced the accuracy of the digital implant impression in regards to Euclidean distance (p = 0.003). No significant difference was found for strategy B in this context. Comparing the two scan strategies revealed that strategy A achieved significantly higher accuracy overall (p = 0.031). CONCLUSION: The quality of digital intraoral impressions seems to be influenced by both the geometry of the scan body and the scan strategy. For clinical practice, the one-step scan strategy seems beneficial. Furthermore, the scan bodies of ELOS A/S showed a potential clinical advantage.


Subject(s)
Dental Implants , Dental Impression Technique , Computer-Aided Design , Dental Impression Materials , Imaging, Three-Dimensional , Models, Dental , Switzerland
SELECTION OF CITATIONS
SEARCH DETAIL
...