Anal Bioanal Chem ; 416(8): 1907-1922, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38332189

ABSTRACT

Smokeless powders (SLPs) are composed of a combination of thermolabile and non-thermolabile compounds. When analysed by GC-MS, injection conditions may therefore play a fundamental role on the characterisation of forensic samples. However, no systematic investigations have ever been carried out. This casts doubt on the optimal conditions that should be adopted in advanced profiling applications (e.g. class attribution and source association), especially when a traditional split/splitless (S/SL) injector is used. Herein, a study is reported that specifically focused on the evaluation of the liner type (Ltype) and inlet temperature (Tinj). Results showed that both could affect the exhaustiveness and repeatability of the observed chemical profiles, with Ltype being particularly sensitive despite typically not being clarified in published works. Perhaps as expected, degradation effects were observed for the most thermolabile compounds (e.g. nitroglycerin) at conditions maximising the heat transfer rates (Ltype = packed and Tinj ≥ 200 °C). However, these did not seem to be as influential as, perhaps, suggested in previous studies. Indeed, the harshest injection conditions in terms of heat transfer rate (Ltype = packed and Tinj = 260 °C) were found to lead to better performances (including better overall %RSDs and LODs) compared to the mildest ones. This suggested that implementing conditions minimising heat-induced breakdowns during injection was not necessarily a good strategy for comparison purposes. The reported findings represent a concrete step forward in the field, providing a robust body of data for the development of the next generation of SLP profiling methods.

4.
Opt Express ; 32(2): 2067-2080, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38297744

ABSTRACT

In the long-wave infrared (LWIR) range, where, due to wavelength scaling, the critical power of Kerr self-focusing Pcr in air increases to 300-400 GW, we demonstrate that without external focusing a train of picosecond CO2 laser pulses can propagate in the form of a single several-centimeter diameter channel over hundreds of meters. The train of 10 µm pulses, for which the total energy ≥20 J is distributed over several near-terawatt picosecond pulses with a maximum power ≤2Pcr, is generated naturally during short pulse amplification in a CO2 laser. It is observed that the high-power 10 µm beam forms a large diameter "hot gas" channel in the ambient air with a ≥ 50 ms lifetime. Simulations of the experiment show that such filamentation-free self-channeling regime has low propagation losses and can deliver multi-Joule/TW-power LWIR pulses over km-scale distances.

5.
Sci Justice ; 63(4): 509-516, 2023 07.
Article in English | MEDLINE | ID: mdl-37453783

ABSTRACT

Knowledge of the number of fibres transferred during a particular activity is essential for the interpretation of findings in similar criminal cases. In this regard, violent contacts and physical assaults still present a challenge, due to a lack of robust published data. Hereby, we present the outcome of an empirical study where different assault activities were simulated by a Jiu Jitsu team and participants were asked to play either the role of an aggressive 'assailant' or a defensive 'victim', wearing cotton garments (i.e., Gi's). Four different scenarios were simulated in replicates (n = 5), each of them involving different intensity levels (low and high) and duration times (30 and 60 s). Results showed that approximately 1,000 to 44,000 fibres were cross-transferred between the participants' garments, with noticeable differences between the different scenarios. These values were significantly larger than those published in previous studies and, therefore, suggested the possibility of a current underestimation of the number of fibres transferred in physical assaults. Furthermore, statistical analysis by ANOVA indicated that the all the variables tested (i.e., intensity level, duration time, and participants role) had a significant effect on the number of transferred fibres (p < 0.001) and, consequently, that some knowledge of the case circumstances may be important to make more educated estimations. This is the first time that such a methodology has been applied for the quantitative assessment of fibre transfer between participants in assault activities. Data are expected to help practitioners with the interpretation of findings in real casework and lead to a more robust evidential assessment.


Subject(s)
Crime Victims , Textiles , Humans
6.
Micromachines (Basel) ; 14(5)2023 Apr 25.
Article in English | MEDLINE | ID: mdl-37241550

ABSTRACT

The utilization of Fiber Bragg Grating (FBG) sensors in innovative optical sensor networks has displayed remarkable potential in providing precise and dependable thermal measurements in hostile environments on Earth. Multi-Layer Insulation (MLI) blankets serve as critical components of spacecraft and are employed to regulate the temperature of sensitive components by reflecting or absorbing thermal radiation. To enable accurate and continuous monitoring of temperature along the length of the insulative barrier without compromising its flexibility and low weight, FBG sensors can be embedded within the thermal blanket, thereby enabling distributed temperature sensing. This capability can aid in optimizing the thermal regulation of the spacecraft and ensuring the reliable and safe operation of vital components. Furthermore, FBG sensors offer sev eral advantages over traditional temperature sensors, including high sensitivity, immunity to electromagnetic interference, and the ability to operate in harsh environments. These properties make FBG sensors an excellent option for thermal blankets in space applications, where precise temperature regulation is crucial for mission success. Nevertheless, the calibration of temperature sensors in vacuum conditions poses a significant challenge due to the lack of an appropriate calibration reference. Therefore, this paper aimed to investigate innovative solutions for calibrating temperature sensors in vacuum conditions. The proposed solutions have the potential to enhance the accuracy and reliability of temperature measurements in space applications, which can enable engineers to develop more resilient and dependable spacecraft systems.

7.
Sensors (Basel) ; 23(5)2023 Feb 24.
Article in English | MEDLINE | ID: mdl-36904714

ABSTRACT

In the upcoming space revolutions aiming at the implementation of automated, smart, and self-aware crewless vehicles and reusable spacecraft, sensors play a significant role in the control systems. In particular, fiber optic sensors, with their small footprint and electromagnetic immunity, represent a great opportunity in aerospace. The radiation environment and the harsh conditions in which these sensors will operate represent a challenge for the potential user in the aerospace vehicle design and the fiber optic sensor specialist. We present a review that aims to be a primer in the field of fiber optic sensors in radiation environments for aerospace. We review the main aerospace requirements and their relationship with fiber optics. We also present a brief overview of fiber optics and sensors based on them. Finally, we present different examples of applications in radiation environments for aerospace applications.

8.
Anal Bioanal Chem ; 414(17): 4987-4998, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35608670

ABSTRACT

Headspace solid-phase micro-extraction (SPME) is a promising technique for the characterisation and profiling of gunshot exhausts in spent cartridge casings, especially for health and environmental risk assessments, as well as forensic purposes. To date, however, no comprehensive investigation has been carried out to objectively assess the kinds of compound released during a discharge that can be recovered by this approach, the selectivity of the main commercially available fibres, and their relative performances for the analysis of gunshot exhausts and the discrimination of different ammunition types. This study aimed to fill this gap. Gunshot exhausts in spent cartridge casings from four different ammunition types were analysed by GC-MS, after extraction with four different commercial fibres: 100 µm polydimethylsiloxane (PDMS), 85 µm polyacrylate (PA), 65 µm polydimethylsiloxane/divinylbenzene (DVB), and 85 µm carboxen/polydimethylsiloxane (CAR). Results showed that, overall, a total of 120 analytes could be observed across the cartridges, but the different tested fibres also displayed distinct performances, which were, to some extent, complementary for the characterisation of gunshot exhausts. DVB, in particular, recovered the most compounds simultaneously. On the other hand, the observed variability between measurements was also high, making it a poor candidate for (semi-)quantitative applications (e.g. estimation of time since discharge and/or source profiling). In this regard, PA demonstrated the highest potential for broad use and implementation in multi-purpose methods.


Subject(s)
Dimethylpolysiloxanes , Solid Phase Microextraction , Gas Chromatography-Mass Spectrometry/methods , Solid Phase Microextraction/methods
9.
Preprint in English | medRxiv | ID: ppmedrxiv-21256423

ABSTRACT

Variability in SARS-CoV-2 susceptibility and COVID-19 disease severity between individuals is partly due to genetic factors. Here, we applied colocalization to compare summary statistics for 16 GWASs from the COVID-19 Host Genetics Initiative to investigate similarities and differences in their genetic signals. We identified 9 loci associated with susceptibility (one with two independent GWAS signals; one with an ethnicity-specific signal), 14 associated with severity (one with two independent GWAS signals; two with ethnicity-specific signals) and one harboring two discrepant GWAS signals (one for susceptibility; one for severity). Utilizing colocalization we also identified 45 GTEx tissues that had eQTL(s) for 18 genes strongly associated with GWAS signals in eleven loci (1-4 genes per locus). Some of these genes showed tissue-specific altered expression and others showed altered expression in up to 41 different tissue types. Our study provides insights into the complex molecular mechanisms underlying inherited predispositions to COVID-19-disease phenotypes.

10.
Forensic Sci Int ; 315: 110432, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32807567

ABSTRACT

Interpretation of fibre evidence at activity level requires extensive knowledge of all the possible transfer mechanisms that may explain the presence of fibres on a recipient surface of interest. Herein, we investigate a transfer method that has been largely understudied in previous literature: contactless transfer between garments through airborne travel. Volunteers were asked to wear UV-luminescent garments composed of different textile materials and situate themselves in a semi-enclosed space (elevator) for a pre-determined period of time with other participants, who wore non-luminescent recipient garments. The latter were then inspected for fibres using UV-luminescent photographic techniques. Results showed that contactless transfer between garments is possible. Indeed, a number of fibres were observed after most of the experiments. As many as 66 and 38 fibres were observed in the experiments involving cotton and polyester donor garments, compared to 2 and 1 fibres in those involving acrylic and wool donor garments, respectively. In this regard, the type of donor garment was found to be a significant factor. Multifactorial ANOVA supported these observations (p<0.001) and further indicated a statistically significant influence of elevator door opening/closing (p<0.001), people entering/exiting (p=0.078) and the recipient garment (p=0.030). Therefore, contactless transfer of fibres between garments can occur and can do so in (ostensibly) high numbers. This should be taken into consideration when interpreting fibre evidence at activity level and may have a major implication for the assignment of evidential values in some specific cases.

11.
Forensic Sci Int ; 311: 110290, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32362519

ABSTRACT

The estimation of the time since last discharge of firearms or spent ammunition elements (e.g., casings) may provide crucial information in the investigation of a shooting incident and, eventually, the following trial. Herein, an exhaustive review of the methods described in the literature is reported, with the aim to evaluate their potential and limitations from a forensic perspective. This work, in particular, highlighted the fact that a number of investigations have been carried out in the field during the last century (with an especially high rate in the last 30 years), but the implementation of related procedures in forensic laboratories is still rare. The situation has been discussed and a series of propositions have been forwarded, in order to overcome challenges and facilitate the implementation of dating approaches in real casework.

12.
Opt Express ; 27(21): 30462-30472, 2019 Oct 14.
Article in English | MEDLINE | ID: mdl-31684294

ABSTRACT

The nonlinear optical response of GaAs is studied using extremely nonresonant 10 µm laser pulses with peak intensities greater than 2 GW/cm 2. We observe over an order of magnitude enhancement in the four-wave mixing efficiency by decreasing the CO 2 laser beat-wave frequency. This enhancement is attributed to currents of photoexcited unbound carriers modulated at the beat frequency, confirmed by measurements of nonlinear absorption at this long wavelength as well as a fully microscopic analysis of the excitation dynamics. Modeling of such nonperturbative semiconductor-laser interactions predicts that further decreasing the beat frequency can increase the nonlinear response and allow for its control over two orders of magnitude.

13.
Anal Chim Acta ; 1072: 1-14, 2019 Sep 23.
Article in English | MEDLINE | ID: mdl-31146860

ABSTRACT

A novel and simplified gradient IC-HRMS approach is presented in this work for forensic profiling of ionic energetic material residues, including low-order explosives and gunshot residue (GSR). This new method incorporated ethanolic eluents to facilitate direct coupling of IC and HRMS without auxiliary post-column infusion pumps that are traditionally used to assist with gas phase transfer. Ethanolic eluents also enabled better integration with an in-service protocol for direct analysis of high-order organic explosives by IC-HRMS, without requiring solvent exchange before injection. Excellent method performance was achieved, enabling both full scan qualitative and quantitative analysis, as required. In particular, linearity for 19 targeted compounds yielded R2 > 0.99 across several orders of magnitude, with trace analysis possible at the low-mid pg level. Reproducibility and mass accuracies were also excellent, with peak area %RSDs <10%, tR %RSDs <0.4% and δm/z < 3 ppm. The method was applied to targeted analysis of latent fingermarks and swabbed hand sweat samples to determine contact with a black-powder substitute containing nitrate, benzoate and perchlorate. When combined with principal component analysis (PCA), the effect of time since handling on recorded signals could be interpreted further in order to support forensic investigations. In a second, non-targeted application, PCA using full scan IC-HRMS data enabled classification of GSR from three different types of ammunition. An additional 20 markers of GSR were tentatively identified in silico, in addition to the 15 anions detected during targeted analysis. This new approach therefore streamlines and adds consistency and flexibility to forensic analysis of ionic energetic material. Furthermore, it also has implications for targeted, non-targeted and suspect screening applications in other fields by expanding the separation space to low molecular weight inorganic and organic anions.

14.
J Forensic Sci ; 64(3): 828-838, 2019 May.
Article in English | MEDLINE | ID: mdl-30332504

ABSTRACT

Positioning landmarks in facial photo-anthropometry (FPA) applications remains today a highly variable procedure, as traditional cephalometric definitions are used as guidelines. Herein, a novel landmark-positioning approach, specifically adapted for FPA applications, is introduced and, in particular, assessed against the conventional cephalometric definitions for the analysis of 16 landmarks on ten frontal images by two groups of examiners (with and without professional knowledge of anatomy). Results showed that positioning reproducibility was significantly better using the novel method. Indeed, in contrast to the classic approach, very low landmark dispersions were observed for both groups of examiners, which were usually below the strictest clinical standards (i.e., 0.575 mm). Furthermore, the comparison between the two groups of examiners highlighted higher dispersion consistencies, which supported a higher robustness. Thus, the use of an adapted landmark-positioning approach proved to be highly advantageous in FPA analysis and future work in this field should consider adopting similar methodologies.


Subject(s)
Anatomic Landmarks , Face/anatomy & histology , Photography , Cephalometry , Female , Forensic Sciences/methods , Humans , Male , Observer Variation , Reproducibility of Results
15.
Analyst ; 144(4): 1128-1139, 2019 Feb 11.
Article in English | MEDLINE | ID: mdl-30474092

ABSTRACT

Evidence association in forensic cases involving gunshot residue (GSR) remains very challenging. Herein, a new in silico approach, called quantitative profile-profile relationship (QPPR) modelling, is reported. This is based on the application of modern machine learning techniques to predict the pre-discharge chemical profiles of selected ammunition components from those of the respective post-discharge GSR. The obtained profiles can then be compared with one another and/or with other measured profiles to make evidential links during forensic investigations. In particular, the approach was optimised and successfully tested for the prediction of GC-MS profiles of smokeless powders (SLPs) from organic GSR in spent cases, for nine ammunition types. Results showed a high degree of similarity between predicted and experimentally measured profiles, after adequate combination and evaluation of fourteen machine learning techniques (median correlation of 0.982). Areas under the curve (AUCs) of 0.976 and 0.824 were observed after receiver operating characteristic (ROC) analysis of the results obtained in the comparisons between predicted-predicted and predicted-measured profiles, respectively, in the specific case that the ammunition types of interest were excluded from the training dataset (i.e., extrapolation). Furthermore, AUCs of 0.962 and 0.894 were observed in interpolation mode. These values were close to those of the comparison of the measured SLP profiles between themselves (AUC = 0.998), demonstrating excellent potential to correctly associate evidence in a number of different forensic scenarios. This work represents the first time that a quantitative approach has successfully been applied to associate a GSR to a specific ammunition.

16.
Sci Total Environ ; 648: 80-89, 2019 Jan 15.
Article in English | MEDLINE | ID: mdl-30114591

ABSTRACT

The application of machine learning has recently gained interest from ecotoxicological fields for its ability to model and predict chemical and/or biological processes, such as the prediction of bioconcentration. However, comparison of different models and the prediction of bioconcentration in invertebrates has not been previously evaluated. A comparison of 24 linear and machine learning models is presented herein for the prediction of bioconcentration in fish and important factors that influenced accumulation identified. R2 and root mean square error (RMSE) for the test data (n = 110 cases) ranged from 0.23-0.73 and 0.34-1.20, respectively. Model performance was critically assessed with neural networks and tree-based learners showing the best performance. An optimised 4-layer multi-layer perceptron (14 descriptors) was selected for further testing. The model was applied for cross-species prediction of bioconcentration in a freshwater invertebrate, Gammarus pulex. The model for G. pulex showed good performance with R2 of 0.99 and 0.93 for the verification and test data, respectively. Important molecular descriptors determined to influence bioconcentration were molecular mass (MW), octanol-water distribution coefficient (logD), topological polar surface area (TPSA) and number of nitrogen atoms (nN) among others. Modelling of hazard criteria such as PBT, showed potential to replace the need for animal testing. However, the use of machine learning models in the regulatory context has been minimal to date and is critically discussed herein. The movement away from experimental estimations of accumulation to in silico modelling would enable rapid prioritisation of contaminants that may pose a risk to environmental health and the food chain.


Subject(s)
Amphipoda/metabolism , Carps/metabolism , Ecotoxicology/methods , Environmental Exposure , Machine Learning , Water Pollutants, Chemical/metabolism , Animals , Models, Biological , Pharmaceutical Preparations/metabolism
18.
Forensic Sci Int Genet ; 37: 215-226, 2018 11.
Article in English | MEDLINE | ID: mdl-30243148

ABSTRACT

The field of DNA intelligence focuses on retrieving information from DNA evidence that can help narrow down large groups of suspects or define target groups of interest. With recent breakthroughs on the estimation of geographical ancestry and physical appearance, the estimation of chronological age comes to complete this circle of information. Recent studies have identified methylation sites in the human genome that correlate strongly with age and can be used for the development of age-estimation algorithms. In this study, 110 whole blood samples from individuals aged 11-93 years were analysed using a DNA methylation quantification assay based on bisulphite conversion and massively parallel sequencing (Illumina MiSeq) of 12 CpG sites. Using this data, 17 different statistical modelling approaches were compared based on root mean square error (RMSE) and a Support Vector Machine with polynomial function (SVMp) model was selected for further testing. For the selected model (RMSE = 4.9 years) the mean average error (MAE) of the blind test (n = 33) was calculated at 4.1 years, with 52% of the samples predicting with less than 4 years of error and 86% with less than 7 years. Furthermore, the sensitivity of the method was assessed both in terms of methylation quantification accuracy and prediction accuracy in the first validation of this kind. The described method retained its accuracy down to 10 ng of initial DNA input or ∼2 ng bisulphite PCR input. Finally, 34 saliva samples were analysed and following basic normalisation, the chronological age of the donors was predicted with less than 4 years of error for 50% of the samples and with less than 7 years of error for 70%.


Subject(s)
Aging/genetics , DNA Methylation , High-Throughput Nucleotide Sequencing , Adolescent , Adult , Aged , Aged, 80 and over , Blood Chemical Analysis , Child , CpG Islands/genetics , Humans , Male , Middle Aged , Models, Statistical , Multiplex Polymerase Chain Reaction , Neural Networks, Computer , Reproducibility of Results , Saliva/chemistry , Semen/chemistry , Sequence Analysis, DNA , Sulfites , Support Vector Machine , Young Adult
19.
Talanta ; 178: 57-68, 2018 Feb 01.
Article in English | MEDLINE | ID: mdl-29136864

ABSTRACT

Retrospective in silico screening of analytical data for the identification of new or emerging disinfection by-products in drinking waters could be useful to assess quality and potential hazards, as well as help implement mitigation procedures more rapidly. Herein, the first study coupling ion exchange chromatography (IC) with high resolution mass spectrometry (HRMS) for the determination of halogenated carboxylic acid disinfectant by-products is reported. Separation was achieved using a Metrohm A Supp 5 column and a Na2CO3/NaHCO3 gradient eluent from 1/0.31 to 10/3.1mM. A variety of solid phase extraction (SPE) sorbents were tested for added selectivity to organic ions and Isolute ENV+ cartridges were selected because of their best overall extraction performance. Method LODs were in the µgL-1 concentration range, with R2 ≥ 0.99 for all the analytes, and isobaric ions could be easily discriminated using HRMS. The method was applied to municipal drinking water. Targeted quantitative analysis revealed the presence of 10 haloacetic acids at levels not exceeding the limits set by WHO and USEPA. Furthermore, suspect screening for additional halogenated carboxylic acids via retrospective HRMS data analysis also indicated the presence of other iodinated HAAs and chlorinated propionic acids, of which one (i.e. monochloropropionic acid) is discussed here for the first time. Most importantly, several potential suspects could be eliminated from further consideration through HRMS data analysis alone. To our knowledge, this represents the first time that a retrospective IC-HRMS screen of halogenated carboxylic acids in drinking water has been reported.


Subject(s)
Carboxylic Acids/analysis , Carboxylic Acids/chemistry , Chromatography, Ion Exchange/methods , Drinking Water/analysis , Halogenation , Mass Spectrometry/methods , Carboxylic Acids/isolation & purification , Solid Phase Extraction , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/chemistry , Water Pollutants, Chemical/isolation & purification
20.
Opt Express ; 22(24): 30013-23, 2014 Dec 01.
Article in English | MEDLINE | ID: mdl-25606931

ABSTRACT

The two-dimensional single shot transverse coherence of the Self-Amplified Spontaneous Emission of the SPARC_LAB Free-Electron Laser was measured through the statistical analysis of a speckle field produced by heterodyning the radiation beam with a huge number of reference waves, scattered by a suspension of particles. In this paper we report the measurements and the evaluation of the transverse coherence along the SPARC_LAB undulator modules. The measure method was demonstrated to be precise and robust, it does not require any a priori assumptions and can be implemented over a wide range of wavelengths, from the optical radiation to the x-rays.