1.
Phys Med Biol ; 54(10): 3141-59, 2009 May 21.
Article in English | MEDLINE | ID: mdl-19420423

ABSTRACT

Computed tomography (CT) dosimetry should be adapted to the rapid developments in CT technology. Recently a 160 mm wide, 320 detector row, cone beam CT scanner that challenges the existing Computed Tomography Dose Index (CTDI) dosimetry paradigm was introduced. The purpose of this study was to assess dosimetric characteristics of this cone beam scanner, to study the appropriateness of existing CT dose metrics and to suggest a pragmatic approach for CT dosimetry for cone beam scanners. Dose measurements with a small Farmer-type ionization chamber and with 100 mm and 300 mm long pencil ionization chambers were performed free in air to characterize the cone beam. According to the most common dose metric in CT, namely CTDI, measurements were also performed in 150 mm and 350 mm long CT head and CT body dose phantoms with 100 mm and 300 mm long pencil ionization chambers, respectively. To explore effects that cannot be measured with ionization chambers, Monte Carlo (MC) simulations of the dose distribution in 150 mm, 350 mm and 700 mm long CT head and CT body phantoms were performed. To overcome inconsistencies in the definition of CTDI100 for the 160 mm wide cone beam CT scanner, doses were also expressed as the average absorbed dose within the pencil chamber (D100). Measurements free in air revealed excellent correspondence between CTDI300air and D100air, while CTDI100air substantially underestimates CTDI300air. Results of measurements in CT dose phantoms and corresponding MC simulations at centre and peripheral positions were weighted and revealed good agreement between CTDI300w, D100w and CTDI600w, while CTDI100w substantially underestimates CTDI300w. D100w provides a pragmatic metric for characterizing the dose of the 160 mm wide cone beam CT scanner. This quantity can be measured with the widely available 100 mm pencil ionization chamber within 150 mm long CT dose phantoms. CTDI300w measured in 350 mm long CT dose phantoms serves as an appropriate standard of reference for characterizing the dose of this CT scanner. A CT dose descriptor that is based on an integration length smaller than the actual beam width is preferably expressed as an (average) dose, such as D100 for the 160 mm wide cone beam CT scanner, and not as CTDI100.


Subject(s)
Body Burden , Cone-Beam Computed Tomography/instrumentation , Cone-Beam Computed Tomography/methods , Radiometry/methods , Equipment Design , Equipment Failure Analysis , Humans , Radiation Dosage , Relative Biological Effectiveness , Reproducibility of Results , Sensitivity and Specificity
2.
Int J Radiat Oncol Biol Phys ; 48(5): 1559-68, 2000 Dec 01.
Article in English | MEDLINE | ID: mdl-11121662

ABSTRACT

PURPOSE: We present a new technique to improve dose uniformity and potentially reduce acute toxicity with tangential whole-breast radiotherapy (RT) using intensity-modulated radiation therapy (IMRT). The technique of multiple static multileaf collimator (sMLC) segments was used to facilitate IMRT. METHODS AND MATERIALS: Ten patients with early-stage breast cancer underwent treatment planning for whole-breast RT using a new method of IMRT. The three-dimensional (3D) dose distribution was first calculated for equally weighted, open tangential fields (i.e., no blocks, no wedges). Dose calculation was corrected for density effects with the pencil-beam superposition algorithm. Separate MLC segments were constructed to conform to the beam's-eye-view projections of the 3D isodose surfaces in 5% increments, ranging from the 120% to 100% isodose surface. Medial and lateral MLC segments that conformed to the lung tissue in the fields were added to reduce transmission. Using the beam-weight optimization utility of the 3D treatment planning system, the sMLC segment weights were then determined to deliver the most uniform dose to 100 reference points that were uniformly distributed throughout the breast. The accuracy of the dose calculation and resultant IMRT delivery was verified with film dosimetry performed on an anthropomorphic phantom. For each patient, the dosimetric uniformity within the breast tissue was evaluated for IMRT and two other treatment techniques. The first technique modeled conventional practice where wedges were derived manually without consideration of inhomogeneity effects (or density correction). A recalculation was performed with density correction to represent the actual dose delivered. In the second technique, the wedges were optimized using the same beam-weight optimization utility as the IMRT plan and included density correction. All dose calculations were based on the pencil-beam superposition algorithm. RESULTS: For the sMLC technique, treatment planning required approximately 60 min. Treatment delivery (including patient setup) required approximately 8-10 min. Film dosimetry measurements performed on an anthropomorphic phantom generally agreed with calculations to within +/- 3%. Compared to the wedge techniques, IMRT with sMLC segments resulted in smaller "hot spots" and a lower maximum dose, while maintaining similar coverage of the treatment volume. A median of only 0.1% of the treatment volume received > or = 110% of the prescribed dose when using IMRT versus 10% with standard wedges. A total of 6-8 segments were required with the majority of the dose delivered via the open segments. The addition of the lung-block segments to IMRT was of significant benefit for patients with a greater proportion of lung parenchyma within the irradiated volume. Since August 1999, 32 patients have been treated in the clinic with the IMRT technique. No patient experienced RTOG grade III or greater acute skin toxicity. CONCLUSION: The use of intensity modulation with an sMLC technique for tangential breast RT is an efficient and effective method for achieving uniform dose throughout the breast. It is dosimetrically superior to the treatment techniques that employ only wedges. Preliminary findings reveal minimal or no acute skin reactions for patients with various breast sizes.


Subject(s)
Breast Neoplasms/radiotherapy , Carcinoma, Ductal, Breast/radiotherapy , Radiotherapy, Conformal/methods , Breast Neoplasms/diagnostic imaging , Carcinoma, Ductal, Breast/diagnostic imaging , Combined Modality Therapy , Female , Humans , Mastectomy, Segmental , Phantoms, Imaging , Quality Control , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed
3.
Int J Radiat Oncol Biol Phys ; 38(2): 301-10, 1997 May 01.
Article in English | MEDLINE | ID: mdl-9226316

ABSTRACT

PURPOSE: We present the preliminary findings of our in-house protocol treating the tumor bed alone after lumpectomy with low-dose-rate (LDR) interstitial brachytherapy in selected patients with early-stage breast cancer treated with breast-conserving therapy (BCT). METHODS AND MATERIALS: Since March 1, 1993, 60 women with early-stage breast cancer were entered into a protocol of tumor bed irradiation only using an interstitial LDR implant with iodine-125. Patients were eligible if the tumor was < or = 3 cm, margins were > or = 2 mm, there was no extensive intraductal component, the axilla was surgically staged, and a postoperative mammogram was performed. Implants were placed using a standardized template either at the time of reexcision or shortly after lumpectomy. A total of 50 Gy was delivered at 0.52 Gy/h over a period of 96 h to the lumpectomy bed plus a 2-cm margin. Perioperative complications, cosmetic outcome, and local control were assessed. RESULTS: The median follow-up for all patients is 20 months. Three patients experienced minimal perioperative pain that required temporary nonnarcotic analgesics. There have been four postoperative infections which resolved with oral antibiotics. No significant skin reactions related to the implant were noted and no patient experienced impaired would healing. Early cosmetic results reveal minimal changes consisting of transient hyperpigmentation of the skin at the puncture sites and temporary induration in the tumor bed. Good to excellent cosmetic results were noted in all 19 patients followed up a minimum of 24 months posttherapy. To date, 51 women have obtained 6-12-month follow-up mammograms and no recurrences have been noted. All patients currently have no physical signs of recurrence, and no patient has failed regionally or distantly. CONCLUSION: Treatment of the tumor bed alone with LDR interstitial brachytherapy appears to be well tolerated, and early results are promising. Long-term follow-up of these patients is necessary to establish the equivalence of this treatment approach compared to standard BCT, however.


Subject(s)
Brachytherapy/methods , Breast Neoplasms/radiotherapy , Carcinoma, Ductal, Breast/radiotherapy , Adult , Aged , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Carcinoma, Ductal, Breast/pathology , Carcinoma, Ductal, Breast/surgery , Combined Modality Therapy , Computer Simulation , Female , Follow-Up Studies , Humans , Iodine Radioisotopes/therapeutic use , Mastectomy, Segmental , Middle Aged , Pilot Projects , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
4.
Int J Radiat Oncol Biol Phys ; 37(4): 845-52, 1997 Mar 01.
Article in English | MEDLINE | ID: mdl-9128961

ABSTRACT

PURPOSE: We reviewed our institution's experience with interstitial implant boosts to determine their long-term impact on local control and cosmetic results. METHODS AND MATERIALS: Between January 1, 1980 and December 31, 1987, 390 women with 400 cases of Stage I and II breast cancer were managed with breast-conserving therapy (BCT) at William Beaumont Hospital. All patients were treated with an excisional biopsy and 253 (63%) underwent reexcision. Radiation consisted of 45-50 Gy external beam irradiation to the whole breast followed by a boost to the tumor bed to at least 60 Gy using either electrons [108], photons [15], or an interstitial implant [277] with either 192Ir [190] or 125I [87]. Long-term local control and cosmetic outcome were assessed and contrasted between patients boosted with either interstitial implants, electrons, or photons. RESULTS: With a median follow-up of 81 months, 25 patients have recurred in the treated breast for a 5- and 8-year actuarial rate of local recurrence of 4 and 8%, respectively. There were no statistically significant differences in the 5- or 8-year actuarial rates of local recurrence using either electrons, photons, or an interstitial implant. Greater than 90% of patients obtained a good or excellent cosmetic result, and no statistically significant differences in cosmetic outcome were seen whether electrons, photons, or implants were used. CONCLUSIONS: We conclude that patients with Stage I and II breast cancer undergoing BCT and judged to be candidates for boosts can be effectively managed with LDR interstitial brachytherapy. Long-term local control and cosmetic outcome are excellent and similar to patients boosted with either electrons or photons.


Subject(s)
Brachytherapy , Breast Neoplasms/radiotherapy , Adult , Biopsy , Breast/pathology , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Combined Modality Therapy , Female , Follow-Up Studies , Humans , Iodine Radioisotopes/therapeutic use , Iridium Radioisotopes/therapeutic use , Multivariate Analysis , Neoplasm Recurrence, Local/epidemiology , Neoplasm Recurrence, Local/surgery , Salvage Therapy , Treatment Outcome
5.
Int J Radiat Oncol Biol Phys ; 33(5): 1229-38, 1995 Dec 01.
Article in English | MEDLINE | ID: mdl-7493847

ABSTRACT

PURPOSE: The goal of this study was to evaluate the dosimetric characteristics of geometric MLC prescription strategies and compare them to those of conventional shielding block. METHODS AND MATERIALS: Circular fields, square fields, and 12 irregular fields for patients with cancer of the head and neck, lung, and pelvis were included in this study. All fields were shaped using the MLC and conventional blocks. A geometric criterion was defined as the amount of area discrepancy between the MLC and the prescription outline. The "least area discrepancy" (LAD) of the MLC conformation was searched by selecting the collimator angle, meanwhile keeping a preselected position along the width of the leaf into the prescribed field. Five LAD conventions were studied. These included the LAD-0, LAD-1/3, LAD-1/2, and LAD-2/3 that inserted the leaves at the 0, 1/3, 1/2, and 2/3 of the leaf end into the prescription field, respectively. In addition, the LAD optimization was applied to the transecting (TRN) approach for leaf conformation that prescribed an equal area of overblocking and underblocking under each leaf. Film dosimetry was performed in a 20 cm polystyrene phantom at 10 cm depth 100 cm from source to axis distance (SAD) for both 6 and 18 MV photons with each of the above MLC conformations and conventional blocks. The field penumbra width, defined as the mean of the separation between the 20% and 80% isodose lines along the normal of the prescription field edge, was calculated using both the MLC and conventional block film dosimetry and compared. In a similar way, the d20 is defined as the mean separation between the 20% isodose line and the prescription field edge, and the d80 is defined as the mean separation between the 80% isodose line and the prescription field edge. RESULTS: The field penumbra width for all MLC conventions was approximately 2 mm larger than that of the conventional block. However, there was a larger variation of the separation distribution in the penumbra region of the irregular fields for the MLC, which had a standard deviation of 1 mm (a factor of 5 larger than the conventional block). The dosimetry for the circular fields showed that the LAD-TRN, LAD-1/2, and LAD-1/3 approximated the conventional blocking well in terms of d20 and d80; however, no single convention produced the best conformation for both measures. The dosimetric result of the patient treatment fields was similar for all sites. The LAD-1/3, LAD-1/2, and LAD-TRN strategies conformed to within 1 to 1.5 mm of the d80 of the conventional block for both 6 MV and 18 MV, respectively. The LAD-1/2 and LAD-TRN conformations were virtually identical, although it is proven analytically that the LAD-1/2 convention has the least overall area discrepancy of all conventions. CONCLUSIONS: The five MLC conformation conventions resulted in similar dosimetric penumbrae for all field shapes studied. The LAD-1/3, LAD-TRN, and LAD-1/2 produced the more favorable approximation to conventional block. The field penumbra width, although useful for evaluating irregular field shapes, could not describe the large local variations in the penumbra along the field edge for the MLC. These local variations could be of clinical concern when they appear near vital organs. However, the variation in a local region can potentially be reduced by minimizing the jaggedness of the leaf steps in that local region. The dosimetric results were useful as guidelines for the clinicians in the evaluation and adjustment of MLC leaf positions.


Subject(s)
Neoplasms/radiotherapy , Particle Accelerators/instrumentation , Radiotherapy, Computer-Assisted/instrumentation , Head and Neck Neoplasms/radiotherapy , Humans , Lung Neoplasms/radiotherapy , Male , Pelvic Neoplasms/radiotherapy , Prostatic Neoplasms/radiotherapy , Radiation Protection/instrumentation , Radiotherapy Dosage , Radiotherapy, Computer-Assisted/methods
6.
Int J Radiat Oncol Biol Phys ; 33(5): 1247-56, 1995 Dec 01.
Article in English | MEDLINE | ID: mdl-7493849

ABSTRACT

PURPOSE: The purpose of this study is to quantify and compare retrospectively the effects of treatment setup variation on beam's eye view (BEV) dosimetry for radiation therapy using a multileaf collimator (MLC) vs. cerrobend block. METHODS AND MATERIALS: A study was performed on a group of 18 patients with cancer of the head and neck, lung, and pelvis who were treated with irregularly shaped fields. The BEV dosimetry of the fields shaped with cerrobend blocks and the MLC was measured with films at the depth of dose prescription in a solid water phantom. A "one-half-leaf" insertion convention was used to shape the MLC. In addition, an average of 15 sequential daily port films was taken per patient during the course of radiotherapy. The port films were aligned with the prescription film for each patient. Systematic error and random error of treatment setup for each patient were calculated. The effects of setup variation were incorporated by convolving the patient portal imaging data with the corresponding BEV film dosimetry. Two parameters were used to quantify the BEV dosimetry. First, the field penumbra width was calculated, which represented the average of the normal separations between 20 and 80% isodose lines along the prescription outline. Second, the ratio of areas covered by the 90 and 20% isodose lines, A90/20, was determined. The BEV dosimetry was then characterized with and without the effects of treatment setup variation. In addition, the difference in BEV dosimetry between the cerrobend block and the MLC was used to estimate the corresponding changes in tumor control probability (TCP). These changes were also compared to the changes in TCP for the treatment with or without the effects of random setup variation. RESULTS: With or without daily setup variation, the use of cerrobend block was more favorable than the MLC in terms of the field penumbra width and A90/20 for all treatment sites. In the absence of daily variation, the MLC field penumbra width was on average 1.3 mm larger than that of the cerrobend block, and 0.9 mm larger in the presence of daily setup variation. Similarly, the ratio A90/20 of the cerrobend block was on average 0.03 larger than that of MLC without daily setup variation, and 0.02 with daily setup variation. The difference in field penumbra width and A90/20 between the MLC and the cerrobend block was slightly reduced due to the effects of daily setup variation. For both the cerrobend block and the MLC, daily setup variation produced a significant increase in the field penumbra width, 2.3 mm for the cerrobend block and 1.9 mm for the MLC, and a decrease in the A90/20, 0.06 for the former and 0.05 for the latter. The change due to the daily setup variation was about a factor of 2 larger than the changes due to replacing the cerrobend block with the MLC. Using the TCP model, the change in TCP due to the daily setup variation was more than a factor of 3 larger than the change in TCP due to replacing the cerrobend block with the MLC. It was noted that the average changes in the penumbra, the A90/20 and the TCP calculated for the patient population did not adequately describe the changes for the individual patient. CONCLUSION: Our results do not show significant dosimetric differences between the MLC and the cerrobend block in conventional radiation treatment, whether or not daily setup variation was taken into consideration. The effects of daily setup variation alone produced a larger dosimetric change. The same results were obtained when the data were applied to calculate changes in TCP. For optimal radiation therapy, efforts should be concentrated on reducing daily setup variation. Our results also demonstrate the importance of frequent evaluation of MLC treatment using electronic portal imaging devices.


Subject(s)
Head and Neck Neoplasms/radiotherapy , Lung Neoplasms/radiotherapy , Particle Accelerators/instrumentation , Pelvic Neoplasms/radiotherapy , Radiotherapy, Computer-Assisted/instrumentation , Equipment Design , Film Dosimetry , Humans , Radiation Protection/instrumentation , Radiotherapy Dosage , Retrospective Studies
7.
Int J Radiat Oncol Biol Phys ; 32(2): 513-20, 1995 May 15.
Article in English | MEDLINE | ID: mdl-7751193

ABSTRACT

PURPOSE: The purpose of this work is to develop a prescription preparation system for efficient field shaping using a multileaf collimator that can be used in community settings as well as research institutions. The efficiency advantage of the computer-controlled multileaf collimator, over cerrobend blocks, to shape radiation fields has been shown in conformal treatments, which typically require complete volumetric computerized tomographic data for three-dimensional radiation treatment planning--a utility not readily available to the general community. As a result, most patients today are treated with conventional radiation therapy. Therefore, we believe that it is very important to fully use the same efficiency advantage of multileaf collimator as a block replacement in conventional practice. METHODS AND MATERIAL: The multileaf collimator prescription preparation system developed by us acquires prescription images from different sources, including film scanner and radiation treatment planning systems. The multileaf collimator angle and leaf positions are set from the desired field contour defined on the prescription image, by minimizing the area discrepancies. Interactive graphical tools include manual adjustment of collimator angle and leaf positions, and definition of portions of the field edges that require maximal conformation. Data files of the final leaf positions are transferred to the multileaf collimator controller via a dedicated communication link. RESULTS: We have implemented the field prescription preparation system and a network model for integrating the multileaf collimator and other radiotherapy modalities for routine treatments. For routine plan evaluation, isodose contours measured with film in solid water phantom at prescription depth are overlaid on the prescription image. Preliminary study indicates that the efficiency advantage of the MLC over cerrobend blocks in conformal therapy also holds true for conventional treatments. CONCLUSION: Our model of computer-controlled prescription, evaluation, and treatment using multileaf collimators can be effectively implemented in both community settings and research institutions. The resultant increase in treatment efficiency and accuracy is now available for conventional radiotherapy.


Subject(s)
Radiotherapy, Computer-Assisted/methods , User-Computer Interface , Equipment Design , Humans , Radiotherapy Dosage , Radiotherapy, Computer-Assisted/instrumentation
8.
Int J Radiat Oncol Biol Phys ; 31(4): 791-7, 1995 Feb 15.
Article in English | MEDLINE | ID: mdl-7860390

ABSTRACT

PURPOSE: We have retrospectively reviewed our institution's experience treating a predominantly mammographically detected population of ductal carcinoma in situ (DCIS) patients with conservative surgery and radiation therapy (CSRT) to determine outcome and prognostic factors for local recurrence. METHODS AND MATERIALS: Between January 1, 1982 and December 31, 1988, 52 consecutive cases of DCIS of the breast were treated with CSRT at William Beaumont Hospital. Forty-six (88%) were mammographically detected nonpalpable lesions. All patients underwent at least an excisional biopsy and 28 (54%) were reexcised. The axilla was surgically staged in 41 (79%) and all were N0. The entire breast was irradiated to 45-50 Gy over 5-6 weeks. The tumor bed was boosted in 49 (94%) so that the minimum dose was 60 Gy. The three patients not boosted received a minimum dose of 50 Gy to the entire breast. Pathologic materials were reviewed by one of the authors. RESULTS: The predominant DCIS pattern was comedo in 40%, cribriform in 28%, solid in 17%, and micropapillary in 15%. The predominant nuclear grade was Grade I in 51%, Grade II in 49%, and Grade III in 0%. The median follow-up is 68 months. There have been three recurrences in the treated breast at a median time to failure of 30 months. The 5- and 8-year actuarial local recurrence rate is 6%. One patient recurred with invasive ductal cancer at 28 months, and the other two recurrences were DCIS at 30 and 50 months. All three patients were treated with salvage mastectomy. The patient who recurred locally with an invasive cancer developed metastasis and died at 64 months. The 5- and 8-year actuarial cause-specific survival rates are 100% and 97%, respectively. The following pathologic factors were analyzed for an association with local recurrence: predominant DCIS histology, predominant nuclear grade, and highest nuclear grade. Of these, the predominant nuclear grade was the best predictor of local recurrence (p = 0.070). No clinical or treatment related factor analyzed was associated with local recurrence. CONCLUSION: Our results indicate that excellent local control (94%) at 8 years is obtainable after CSRT in a mammographically detected population of patients with DCIS. The predominant nuclear grade was the only factor found that may be associated with local recurrence.


Subject(s)
Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Carcinoma in Situ/radiotherapy , Carcinoma in Situ/surgery , Carcinoma, Ductal, Breast/radiotherapy , Carcinoma, Ductal, Breast/surgery , Neoplasm Recurrence, Local/epidemiology , Adult , Aged , Aged, 80 and over , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/mortality , Carcinoma in Situ/diagnostic imaging , Carcinoma in Situ/mortality , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Ductal, Breast/mortality , Female , Humans , Mammography , Middle Aged , Neoplasm Recurrence, Local/mortality , Neoplasm Recurrence, Local/pathology , Prognosis , Retrospective Studies , Salvage Therapy , Time Factors , Treatment Outcome
9.
Int J Radiat Oncol Biol Phys ; 30(3): 707-14, 1994 Oct 15.
Article in English | MEDLINE | ID: mdl-7928504

ABSTRACT

PURPOSE: The purpose of this work is to develop a prescription preparation system for efficient field shaping using a multileaf collimator that can be used in community settings as well as research institutions. The efficiency advantage of the computer-controlled multileaf collimator, over cerrobend blocks, to shape radiation fields has been shown in conformal treatments, which typically require complete volumetric computerized tomographic data for three-dimensional radiation treatment planning--a utility not readily available to the general community. As a result, most patients today are treated with conventional radiation therapy. Therefore, we believe that it is very important to fully use the same efficiency advantage of multileaf collimator as a block replacement in conventional practice. METHODS AND MATERIAL: The multileaf collimator prescription preparation systems developed by us acquires prescription images from different sources, including film scanner, and radiation treatment planning systems. The multileaf collimator angle and leaf positions are set from the desired field contour defined on the prescription image, by minimizing the area discrepancies. Interactive graphical tools include manual adjustment of collimator angle and leaf positions, and definition of portions of the field edges that require maximal conformation. Data files of the final leaf positions are transferred to the multileaf collimator controller via a dedicated communication link. RESULTS: We have implemented the field prescription preparation system and a network model for integrating the multileaf collimator and other radiotherapy modalities for routine treatments. For routine plan evaluation, isodose contours measured with film in solid water phantom at prescription depth are overlaid on the prescription image. Preliminary study indicates that the efficiency advantage of the MLC over cerrobend blocks in conformal therapy also holds true for conventional treatments. CONCLUSION: Our model of computer-controlled prescription, evaluation, and treatment using multileaf collimators can be effectively implemented in both community settings and research institutions. The resultant increase in treatment efficiency and accuracy is now available for conventional radiotherapy.


Subject(s)
Radiotherapy Dosage , Radiotherapy/instrumentation , Humans , Local Area Networks
10.
Cancer ; 74(2): 640-7, 1994 Jul 15.
Article in English | MEDLINE | ID: mdl-8033043

ABSTRACT

BACKGROUND: The authors have reviewed their institution's experience with conservative surgery and radiation therapy for early stage breast cancer with the goal of defining the impact of infiltrating lobular histology (ILC) on the local recurrence rate. Also, they have examined the preoperative mammograms of the ILC patients to determine if mammographic features could be used to predict treatment outcome. METHODS: Between January 1, 1980, and December 31, 1987, 402 cases of Stages I and II breast cancer were treated with conservative surgery and radiation therapy (BCT) at William Beaumont Hospital. Each patient had at least an excisional biopsy. Radiation consisted of 45-50 Gy to the entire breast followed by a supplemental boost dose, so that a minimum of 60 Gy was delivered to the tumor bed. Thirty cancers were classified histologically as infiltrating lobular carcinoma (ILC), 346 as infiltrating ductal carcinoma (IDC), and 26 as other. Median follow-up is 60 months. RESULTS: There was no significant difference in 5 year actuarial local recurrence rates between ILC and IDC, 3.3 versus 4.2%, respectively, (P = not significant). Preoperative mammograms were retrospectively reviewed for 29 of the 30 ILC patients. A spiculated opacity was the most common primary mammographic finding (63%), followed by architectural distortion (17%), poorly defined opacity (7%), and negative (7%). Of the patients who had a preoperative primary mammographic finding of a spiculated opacity, 55% underwent reexcision after the initial excisional biopsy, and residual invasive carcinoma was found in 18% of the reexcision specimens. In contrast, of the patients with a primary mammographic finding of an architectural distortion, poorly defined opacity, or negative, 89% underwent reexcision after an initial excisional biopsy, and residual invasive carcinoma was found in 100% of the reexcision specimens. CONCLUSIONS: Infiltrating lobular carcinoma does not have a worse local recurrence rate compared with IDC when each is treated with breast-conserving therapy. The primary finding on preoperative mammograms in patients with ILC may prove to be a useful tool for predicting the likelihood of residual carcinoma in the breast after initial excisional biopsy.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/therapy , Carcinoma, Lobular/diagnostic imaging , Carcinoma, Lobular/therapy , Mammography , Adult , Aged , Aged, 80 and over , Combined Modality Therapy , Female , Humans , Middle Aged , Patient Care Planning , Preoperative Care , Retrospective Studies
11.
Int J Radiat Oncol Biol Phys ; 27(3): 561-6, 1993 Oct 20.
Article in English | MEDLINE | ID: mdl-8226149

ABSTRACT

PURPOSE: We have previously reported that the use of iodine-125 seeds in temporary plastic tube interstitial implants may be more advantageous than iridium-192 seeds due to less patient and personnel radiation exposure, reduced shielding requirements, and significant dosimetric advantages. The impact of this isotope on the rate of local control and cosmetic outcome in patients with early stage breast cancer treated with interstitial implants for their irradiation "boost" remains to be defined. METHODS AND MATERIALS: We reviewed the treatment outcome of 402 consecutive cases of Stage I and II breast cancer undergoing breast conserving therapy between 1/1/80 and 12/31/87. All patients underwent excisional biopsy and received 45-50 Gy to the entire breast followed by a boost to the tumor bed using either electrons (104 patients), photons (15 patients), or an interstitial implant with either iridium-192 (197 patients) or iodine-125 (86 patients) to at least 60 Gy. Iodine-125 implants were primarily performed in patients with significant risk factors for local recurrence (71%) or in patients with large breasts (17%). Local tumor control and cosmetic outcome were assessed and contrasted between patients boosted with each modality. RESULTS: With a median follow-up of 59.3 months, 18 (4.5%) patients developed a recurrence of the tumor in the treated breast (4.4% 5-year actuarial rate). No statistically significant differences in the 5-year actuarial rate of local recurrence were noted between patients boosted with either iodine-125 (3.0%), iridium-192 (3.8%), electrons (5.4%), or photons (0%). Likewise, no significant differences in the percentage of patients obtaining good/excellent cosmetic results were noted between iodine-125 (93%), iridium-192 (88%), electrons (90%), or photons (82%). CONCLUSION: We conclude that patients with Stage I and II breast cancer undergoing breast conserving therapy and judged to be candidates for boosts with interstitial implants can be effectively treated with iodine-125 seeds. Use of this isotope results in less patient and personnel irradiation exposure and a better dose distribution than iridium-192, since dose optimization can be routinely employed. Overall, local control and cosmetic outcome have been excellent and are similar to either iridium-192, electrons, or photons.


Subject(s)
Brachytherapy , Breast Neoplasms/radiotherapy , Iodine Radioisotopes/therapeutic use , Iridium Radioisotopes/therapeutic use , Female , Humans
12.
J Natl Med Assoc ; 84(11): 951-5, 1992 Nov.
Article in English | MEDLINE | ID: mdl-1460682

ABSTRACT

Paratesticular liposarcoma is extremely rare. Only 41 cases have been reported in the literature. This article reports two cases, reviews the literature, discusses the pathology, and proposes the use of combined surgery and radiation therapy in selected cases.


Subject(s)
Liposarcoma , Testicular Neoplasms , Aged , Humans , Liposarcoma/pathology , Liposarcoma/surgery , Male , Testicular Neoplasms/pathology , Testicular Neoplasms/surgery
13.
Cancer ; 68(3): 502-8, 1991 Aug 01.
Article in English | MEDLINE | ID: mdl-1648431

ABSTRACT

Two patients with collagen vascular disease (rheumatoid arthritis and scleroderma) had extremely poor cosmetic results after breast radiation therapy (RT). The patient with rheumatoid arthritis received 5251 cGy at 210 cGy per day, followed by a 1600 cGy iridium-192 implant boost. Between 8 and 11 months post-RT she had severe breast fibrosis, retraction, and pain that required a mastectomy for relief. The patient with scleroderma received 5040 cGy at 180 cGy per day without a boost. Between 1 and 4 months post-RT the systemic symptoms of scleroderma progressed and the breast became hard and retracted. Both rheumatoid arthritis and scleroderma are chronic systemic diseases characterized by severe inflammation and an autoimmune component. The presence of scleroderma at or before treatment should be considered a contraindication to breast RT, whereas the presence of active rheumatoid arthritis should be considered a relative contraindication. An autoimmune mechanism will be presented to explain both the fibrosis and the systemic progression of collagen vascular disease that was observed.


Subject(s)
Adenocarcinoma/radiotherapy , Arthritis, Rheumatoid/complications , Breast Diseases/etiology , Breast Neoplasms/radiotherapy , Carcinoma, Intraductal, Noninfiltrating/radiotherapy , Mastectomy, Segmental , Radiotherapy/adverse effects , Scleroderma, Systemic/complications , Adenocarcinoma/complications , Adenocarcinoma/surgery , Brachytherapy/adverse effects , Breast Neoplasms/complications , Breast Neoplasms/surgery , Carcinoma, Intraductal, Noninfiltrating/complications , Carcinoma, Intraductal, Noninfiltrating/surgery , Combined Modality Therapy/adverse effects , Female , Fibrosis/etiology , Follow-Up Studies , Humans , Mastectomy, Segmental/adverse effects , Middle Aged , Models, Biological , Pain/etiology , Pain Management , Retrospective Studies , Risk Factors
14.
Acta Endocrinol (Copenh) ; 122(3): 323-8, 1990 Mar.
Article in English | MEDLINE | ID: mdl-2327213

ABSTRACT

In this study we have examined the correlation between activity of erythropoiesis and serum concentrations of erythropoietin and insulin-like growth factor I in male and female rats during accelerated growth (day 30-90). We found that fractional incorporation of iron into newly formed red blood cells was linearily correlated with body weight gain. Total iron incorporation into newly formed red blood cells reflecting total daily red cell formation increased almost linearily between day 25 and 80 after birth in both sexes. While serum erythropoietin concentrations decreased in the time interval investigated (25-120 days), serum IGF-I levels increased in both sexes between day 25 and 55. In this period, individual values of total iron incorporation into red blood cells and serum IGF-I concentrations were linearily correlated. Our observations support the concept that IGF-I rather than erythropoietin modulates erythropoiesis during accelerated growth and thus manages a proportional increase in body mass and oxygen transport capacity.


Subject(s)
Erythropoiesis/physiology , Erythropoietin/blood , Growth/physiology , Insulin-Like Growth Factor I/metabolism , Somatomedins/metabolism , Aging/blood , Animals , Erythrocytes/metabolism , Female , Iron Radioisotopes/blood , Male , Rats , Rats, Inbred Strains , Weight Gain
15.
Int J Radiat Oncol Biol Phys ; 17(4): 859-63, 1989 Oct.
Article in English | MEDLINE | ID: mdl-2777677

ABSTRACT

In August of 1986 at William Beaumont Hospital, Iodine-125 (I-125) seeds were introduced in the clinical practice as a substitute for Iridium-192 (Ir-192) seeds in patients undergoing temporary plastic tube interstitial implants. Through February 1988, 108 I-125 implants were performed in 105 patients. Acute and chronic toxicity was indistinguishable from Ir-192. However, improved radiation safety and a dynamic dosimetric program have resulted from this endeavor. Because of the multiple clinical advantages of I-125, we feel that this should be considered the isotope of choice in temporary interstitial plastic tube implants.


Subject(s)
Brachytherapy/methods , Indium Radioisotopes/therapeutic use , Iodine Radioisotopes/therapeutic use , Breast Neoplasms/radiotherapy , Head and Neck Neoplasms/radiotherapy , Humans , Radiotherapy Dosage , Tongue Neoplasms/radiotherapy
16.
Int J Radiat Oncol Biol Phys ; 15(4): 1027-33, 1988 Oct.
Article in English | MEDLINE | ID: mdl-3182311

ABSTRACT

In August of 1986, the Department of Radiation Oncology at William Beaumont Hospital (WBH) initiated the routine use of high activity I-125 seeds as a substitute for Ir-192 seeds in temporary implants where the afterloading plastic tube technique was used. Through March 6, 1987, 42 temporary I-125 implants were performed as a boost for curative therapy (38 breasts, 2 sarcomas, 2 tongues). Thus far, we have observed no differences in acute toxicity. Sources ranging from 2 to 5 mCi were utilized. The advantages of I-125 are as follows: (a) Easy to shield; (b) Radiation safety; (c) Decreased exposure to sensitive organs in close proximity to the implanted site; (d) Dosimetric advantages both intrinsic and extrinsic; and (e) Any private room can be used for these patients allowing a central brachytherapy ward to be established. While the advantages were obvious, we anticipated potential disadvantages and shortcomings and these will be discussed in detail. Furthermore because of significant differences in tube and ribbon construction, the I-125 afterloading plastic tube technique has important differences from that technique used with Ir-192. These modifications must be fully understood to maintain the integrity of the I-125 seed-ribbon afterloading tube assembly. A detailed description of the technique will be emphasized.


Subject(s)
Brachytherapy/methods , Iodine Radioisotopes/therapeutic use , Iridium Radioisotopes/therapeutic use , Neoplasms/radiotherapy , Brachytherapy/instrumentation , Humans , Iodine Radioisotopes/administration & dosage , Iridium Radioisotopes/administration & dosage , Radiation Protection , Time Factors
17.
Article in German | MEDLINE | ID: mdl-7444402

ABSTRACT

A catamnestic examination in the sense of a pilot study concerning 104 patients having been treated between 1972 and 1976 in the Basle Psychiatric University outpatient clinic was centered on preponderately the following items "former psychiatric treatment", "suicidal attempts", "socioeconomic conditions", childhood" and "conditions of habitations". The collective of patients was presented by 52 psychogenic depressives and 52 alcohol- respectively drug-dependants. Of each group half of the patients had one or more suicidal attempts behind them. The comparison of the 2 diagnostic groups and of the patients with suicidal attempts with those who had never attempted suicide showed, among other significant findings, that the patients with suicidal attempts lived in the childhood and in the actual situations in worse conditions of habitation than those having never attempted suicide. This correlation was interpreted as a consequence of direct confinement by a narrow space and indirect confinement by pathological interactions and disturbances in the self development.


Subject(s)
Alcoholism/psychology , Depressive Disorder/psychology , Socioeconomic Factors , Substance-Related Disorders/psychology , Suicide, Attempted/psychology , Achievement , Adolescent , Adult , Child , Child Development , Family Characteristics , Female , Follow-Up Studies , Humans , Male
18.
Cancer ; 38(1): 1-7, 1976 Jul.
Article in English | MEDLINE | ID: mdl-779949

ABSTRACT

In a randomized and stratified study, 294 patients with advanced gastrointestinal cancer were treated either with 5-fluorouracil (5-FU) 400 mg/m2 weekly intravenously (i.v.) or 5-FU 400 mg/m2 i.v. weekly plus methyl-CCNU 175 mg/m2 orally (p.o.) every 6 weeks. The response rate in colorectal cancer with 5-FU was 9.5% while the two-drug treatment produced a response of 31.8% (p=.009). The response in all gastrointestinal cancers to 5-FU was 10.6% as compared with29.3% for the combination (p=.012). All responses were partial. The two-drug regimen is more effective and more toxic than weekly 5-FU therapy.


Subject(s)
Fluorouracil/therapeutic use , Gastrointestinal Neoplasms/drug therapy , Nitrosourea Compounds/therapeutic use , Semustine/therapeutic use , Adolescent , Adult , Aged , Clinical Trials as Topic , Drug Therapy, Combination , Female , Fluorouracil/administration & dosage , Fluorouracil/adverse effects , Hematopoietic System/drug effects , Humans , Injections, Intravenous , Male , Middle Aged , Neoplasm Metastasis , Remission, Spontaneous , Semustine/administration & dosage , Semustine/adverse effects , Sex Factors , Time Factors
20.
Science ; 152(3730): 1760-1, 1966 Jun 24.
Article in English | MEDLINE | ID: mdl-4287164

ABSTRACT

I-Adamantanamine hydrochloride, added to chick embryo cells, inhibited focus production upon subsequent inoculation of the cells with Rous and Esh sarcoma viruses. Addition of the chemical to suspensions of Rous and Esh viruses before they were added to chick cell cultures did not inactivate the viruses; and the addition to chick cells did not prevent plaque formation following their inoculation with Newcastle disease virus. This indicates that cells treated with 1-adamantanamine hydrochloride are capable of supporting viral replication, and these observations suggest that the drug inhibits growth of two oncogenic viruses by prevention of virus penetration, but not by a virucidal effect or cell intoxication.


Subject(s)
Antiviral Agents/pharmacology , Avian Sarcoma Viruses/drug effects , Oncogenic Viruses/drug effects , Amantadine/pharmacology , Animals , Chick Embryo , In Vitro Techniques , Newcastle disease virus , Virus Cultivation
SELECTION OF CITATIONS