Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Respir Care ; 69(4): 407-414, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38164566

ABSTRACT

BACKGROUND: In children with congenital heart disease, extubation readiness testing (ERT) is performed to evaluate the potential for liberation from mechanical ventilation. There is a paucity of data that suggests what mechanical ventilation parameters are associated with successful ERT. We hypothesized that ERT success would be associated with certain mechanical ventilator parameters. METHODS: Data on daily ERT assessments were recorded as part of a quality improvement project. In accordance with our respiratory therapist-driven ventilator protocol, patients were assessed daily for ERT eligibility and tested daily, if eligible. Mechanical ventilation parameters were categorized a priori to evaluate the differences in levels of respiratory support. The primary outcome was ERT success. RESULTS: A total of 780 ERTs from 320 subjects (median [interquartile range] age 2.5 [0.6-6.5] months and median weight [interquartile range] 4.2 [3.3-6.9] kg) were evaluated. A total of 528 ERTs (68%) were passed, 306 successful ERTs (58%) resulted in extubation, and 30 subjects (9.4%) were re-intubated. There were statistically significant differences in the ERT pass rate for ventilator mode, peak inspiratory pressure, Δ pressure, PEEP, mean airway pressure ([Formula: see text]), and dead-space-to-tidal-volume ratio (all P < .001) but not for [Formula: see text]. ERT success decreased with increases in peak inspiratory pressure, Δ pressure, PEEP, [Formula: see text], and dead-space-to-tidal-volume ratio. Logistic regression revealed neonates, Δ pressure ≥ 11 cm H2O, and [Formula: see text] > 10 cm H2O were associated with a decreased odds of ERT success, whereas children ages 1-5 years and an [Formula: see text] of 0.31-0.40 had increased odds of ERT success. CONCLUSIONS: ERT pass rates decreased as ventilator support increased; however, some subjects were able to pass ERT despite high ventilator support. We found that [Formula: see text] was associated with ERT success and that protocols should consider using [Formula: see text] instead of PEEP thresholds for ERT eligibility. Cyanotic lesions were not associated with ERT success, which suggests that patients with cyanotic heart disease can be included in ERT protocols.


Subject(s)
Heart Defects, Congenital , Ventilator Weaning , Infant, Newborn , Child , Humans , Child, Preschool , Ventilator Weaning/methods , Airway Extubation , Respiration, Artificial , Ventilators, Mechanical , Heart Defects, Congenital/therapy
2.
Respir Care ; 68(3): 300-308, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36414274

ABSTRACT

BACKGROUND: Extubation readiness testing (ERT) is often performed in children with congenital heart disease prior to liberation from mechanical ventilation. The ideal ERT method in this population is unknown. We recently changed our ERT method from variable (10, 8, or 6 cm H2O, depending on endotracheal tube size) to fixed (5 cm H2O) pressure support (PS). Our study assessed the association between this change and time to first extubation and need for re-intubation. METHODS: We studied 2 temporally distinct cohorts, one where ERT was conducted with variable PS and another using PS fixed at 5 cm H2O. Data were prospectively collected as part of a quality improvement project. The primary outcome was time to first extubation. Secondary outcomes were need for re-intubation and percentage of successful ERTs. We performed Poisson regression or logistic regression for the association between PS during ERT and time to first extubation or re-intubation, respectively. RESULTS: We included 320 subjects, 186 in the variable PS group and 152 in fixed PS group. In unadjusted analysis, median time to first extubation was longer in the fixed PS group compared to the variable PS group (4.1 [2.0-7.1] d vs 3.1 [1.1-5.9] d, P = .02), and there was no difference in re-intubation rate (11% vs 8%, P = .34). Subjects in the fixed PS group were significantly more likely to be mechanically ventilated after cardiac arrest, have a Society of Thoracic Surgeons-European Association for Cardio-Thoracic Surgery (STAT) category of 4 or 5, be extubated on day shift, receive enteral feeds at extubation, have higher respiratory support at extubation, and higher dead-space-to-tidal-volume ratio. After controlling for these variables in multivariable regression, we found no association between the choice of PS and time to first extubation or re-intubation. CONCLUSIONS: The use of a fixed PS of 5 cm H2O instead of variable PS during ERT was not associated with longer time to first extubation or extubation failure.


Subject(s)
Heart Defects, Congenital , Ventilator Weaning , Humans , Child , Ventilator Weaning/methods , Airway Extubation , Positive-Pressure Respiration/methods , Respiration, Artificial/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...