Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Healthcare (Basel) ; 10(3)2022 Mar 18.
Article in English | MEDLINE | ID: mdl-35327046

ABSTRACT

BACKGROUND: During the COVID-19 pandemic, lung ultrasound (LUS) has been widely used since it can be performed at the patient's bedside, does not produce ionizing radiation, and is sufficiently accurate. The LUS score allows for quantifying lung involvement; however, its clinical prognostic role is still controversial. METHODS: A retrospective observational study on 103 COVID-19 patients with respiratory failure that were assessed with an LUS score at intensive care unit (ICU) admission and discharge in a tertiary university COVID-19 referral center. RESULTS: The deceased patients had a higher LUS score at admission than the survivors (25.7 vs. 23.5; p-value = 0.02; cut-off value of 25; Odds Ratio (OR) 1.1; Interquartile Range (IQR) 1.0-1.2). The predictive regression model shows that the value of LUSt0 (OR 1.1; IQR 1.0-1.3), age (OR 1.1; IQR 1.0-1.2), sex (OR 0.7; IQR 0.2-3.6), and days in spontaneous breathing (OR 0.2; IQR 0.1-0.5) predict the risk of death for COVID-19 patients (Area under the Curve (AUC) 0.92). Furthermore, the surviving patients showed a significantly lower difference between LUS scores at admission and discharge (mean difference of 1.75, p-value = 0.03). CONCLUSION: Upon entry into the ICU, the LUS score may play a prognostic role in COVID-19 patients with ARDS. Furthermore, employing the LUS score as a monitoring tool allows for evaluating the patients with a higher probability of survival.

2.
Acta Biomed ; 92(4): e2021101, 2021 09 02.
Article in English | MEDLINE | ID: mdl-34487073

ABSTRACT

COVID-19 infection has several cardiovascular implications, and coagulopathy is a common abnormality in these patients, often coupled with elevated plasma fibrinogen and D-dimer levels, contributing to adverse outcomes. Phlegmasia cerulea dolens (PCD) is a rare manifestation of deep vein thrombosis. It is life-threatening and can rapidly lead to venous gangrene of the extremity. Only a few cases of COVID-19 associated with PCD are reported in the literature, despite thromboembolism being the common paradigm between the two diseases. We present the case of a 64-year-old adult with acute severe COVID-19 pneumonia who developed PCD despite constantly elevated activated partial thromboplastin time and international normalized ratio.


Subject(s)
COVID-19 , Disseminated Intravascular Coagulation , Thrombophlebitis , Venous Thrombosis , Adult , Disseminated Intravascular Coagulation/complications , Gangrene , Humans , Middle Aged , SARS-CoV-2 , Thrombophlebitis/etiology , Venous Thrombosis/etiology
3.
Ultrasound J ; 12(1): 10, 2020 Mar 06.
Article in English | MEDLINE | ID: mdl-32140875

ABSTRACT

BACKGROUND: Pregnancy-induced changes in cardiovascular status make women more susceptible to pulmonary edema. During cesarean section, to counterbalance the effect of hypotension caused by spinal anesthesia, anesthesiologists must choose between two fundamental approaches to maintain the hemodynamic state-intravenous fluids or vasopressors-and this choice will depend upon their particular opinions and experience. We aim to assess for any correlations between thoracic ultrasound A- and B-line artifacts, brain natriuretic peptide (BNP) levels, and the amount of intraoperative fluids administered. RESULTS: From December 2016 to August 2018, at the University-Hospital of Udine, we enrolled 80 consecutive pregnant women undergoing cesarean section. We observed a statistically significant difference in the volume of fluids administered in the first 24 h (p = 0.035) between the patients presenting B-lines in at least one basal area of their thoracic ultrasound and patients with no evident B-lines (AUC 66.4%; IC 0.49-0.83). Dividing the population on whether their BNP levels were higher or less than 20 pg/mL, no statistically significant difference was revealed with regard to fluids administered in the first 24 h (p = 0.537). CONCLUSIONS: Thoracic ultrasound is a non-invasive and easy-to-use tool for detecting fluid intolerance in pregnant women undergoing cesarean section. BNP levels were slow to rise following the cesarean section and did not show any clear correlation with fluid volumes administered.

SELECTION OF CITATIONS
SEARCH DETAIL
...