Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 189
Filter
1.
Arch Orthop Trauma Surg ; 144(5): 2267-2271, 2024 May.
Article in English | MEDLINE | ID: mdl-38587669

ABSTRACT

The symmetry of the flexion and extension gap influences the functional and long-term outcome after total knee arthroplasty (TKA). Most surgeons check it by applying varus and valgus stress using spacers. This technique has limited accuracy and could be easily extended by rotational movement of the spacer. The objective was to determine the detection threshold and interobserver reliability of this technique. In an in vitro setting with a human cadaveric knee, gap asymmetries were simulated by different medially and laterally applied forces. Using an optical measurement system, the pivot point of the spacer was calculated as a function of the gap symmetry in the first part of the experiment. In the second part, the detection threshold and interobserver reliability of 4 surgeons were determined. For this purpose, gap asymmetries were adjusted to between 0 and 120N in a blinded trial. With a symmetrical gap, the centre of rotation of the spacer was located in the centre of the tibia. With increasing gap asymmetry, the centre of rotation of the spacer shifted to the tight side. This shift was approximately linearly dependent on the force difference. A perfectly balanced gap was detected by the examiners in 50% of the cases. From a force difference of 40N, all examiners identified the gap asymmetry in all cases (ICC = 1.0). The method of spacer rotation described is suitable for reliably detecting gap differences at ≥ 40N, independently of the examiner.


Subject(s)
Arthroplasty, Replacement, Knee , Cadaver , Humans , Arthroplasty, Replacement, Knee/methods , Rotation , Knee Prosthesis , Range of Motion, Articular , Knee Joint/surgery , Knee Joint/physiology , Knee Joint/physiopathology , Biomechanical Phenomena , Observer Variation
2.
Arch Orthop Trauma Surg ; 144(5): 2283-2295, 2024 May.
Article in English | MEDLINE | ID: mdl-38625551

ABSTRACT

INTRODUCTION: The rate of revision TKA and thus the use of hinged implants (HI) steadily rises. Aseptic loosening lies on the top of the failure patterns. However, no evidence exists until now based on national scale high-caseloads that analyzes the impact of cemented HI stem-design on aseptic survival rates. METHODS: Data on aseptic HI-revisions with full-cemented tibia-stems were conducted from the German Arthroplasty Registry. Cases were divided in primary HI (PHI) and HI used in revision operations (RHI). Endpoint was a new revision following either a PHI or an RHI. The impact of stem conicity (conical vs. cylindrical), diameter (≤ 13 mm vs. > 13 mm), length (≤ 90 mm vs. > 90 mm) and offset on the 6-Year-Cumulative-Aseptic-Revision-Rate (6Y-CARR) was estimated via Kaplan-Meier curve and compared between groups via Log-Rank-Tests. RESULTS: 3953 PHI and 2032 RHI fulfilled inclusion-criteria. Stem conicity had no impact on 6Y-CARR (p = 0.08 and p = 0.8). Diameter > 13 mm hat an impact on PHI (p = 0.05) with lower 6Y-CARR but not on RHI (p = 0.2). Length > 90 mm showed significantly worst 6Y-CARR in PHI (p = 0.0001) but not in RHI (p = 0.3). Offset-stems showed significantly better 6Y-CARR in PHI (p = 0.04), but not in RHI (p = 0.7). CONCLUSION: There was no significant impact of the cemented tibia-stem conicity on 6Y-CARR, neither in PHI nor in RHI. The effect of length, diameter and offset on the 6Y-CARR observed in the PHI, was not detectable in the more complex RHI-cases reflecting its limited clinical relevance by itself in more multifactorial backgrounds. Therefore, results must be interpreted with caution due to considerable system-effects and different utilization-scenarios.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Prosthesis Design , Prosthesis Failure , Registries , Reoperation , Humans , Arthroplasty, Replacement, Knee/methods , Arthroplasty, Replacement, Knee/instrumentation , Germany/epidemiology , Reoperation/statistics & numerical data , Male , Aged , Female , Tibia/surgery , Middle Aged , Bone Cements
3.
J Clin Med ; 13(8)2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38673482

ABSTRACT

Background: Even minor adverse reactions after total hip replacement (THR), including lymphedema, postoperative leg swelling, and blood loss, compromise patient comfort in times of minimally invasive fast-track surgery. Compression dressings are commonly used in surgical practice to reduce swelling or blood loss. However, the use of spica hip compression dressings after primary THR is controversial, and prospective studies are lacking. Methods: We conducted a prospective, single-center, two-arm, randomized controlled trial (RCT) of patients undergoing THR for primary osteoarthritis. A total of 324 patients were enrolled; 18 patients were excluded, and 306 patients were finally analyzed. Leg swelling as primary endpoint was measured pre- and postoperatively with a rotating 3D infrared body scanner. Secondary endpoints were transfusion rate and blood loss, estimated by Nadler and Gross formulas. Results: Postoperative leg swelling was lower in the compression group (241 ± 234 mL vs. 307 ± 287 mL; p = 0.01), even after adjustment for surgery time and Body-Mass-Index (BMI) (p = 0.04). Estimated blood loss was also lower in the compression group on the first (428 ± 188 mL vs. 462 ± 178 mL; p = 0.05) and third (556 ± 247 mL vs. 607 ± 251 mL; p = 0.04) postoperative days and leveled off on the fifth postoperative day, but lost significance after adjustment for BMI and surgery time. Neither group received a transfusion. Conclusions: Compression dressing after THR in the context of minimally invasive surgery slightly reduces leg swelling, but has no effect on blood loss or blood transfusion rate. So, this method could not generally be recommended in primary hip replacement.

4.
J Pers Med ; 14(3)2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38541006

ABSTRACT

Empyema of the joint is an orthopedic emergency that is associated with a prolonged healing process despite adequate surgical and medical therapy. The risk of developing postinfectious osteoarthritis (OA) after successfully treated joint empyema is unknown. Both incidence and risk factors are important for prognostication and would therefore be clinically relevant for the selection of an adequate infectious therapy as well as for the individual follow-up of patients. The aim of this retrospective clinical study was to describe the risk of secondary OA after empyema based on knee and shoulder joint infections after successful primary infection treatment and its risk factors. Thirty-two patients were examined clinically and radiographically after completion of treatment for primary empyema of the knee or shoulder joint. Patients with previous surgery or injections in the affected joint were excluded from the study. The cumulative incidence of new-onset radiographic OA was 28.6%, representing a 5.5-fold increased risk of developing OA compared to the normal population. A figure of 25% of patients underwent total knee arthroplasty after knee empyema. Identified risk factors for primary empyema were obesity, hyperuricemia, and rheumatoid arthritis. Only about 60% of the patients tested positive for bacteria. Staphylococcus aureus, the most common pathogen causing joint empyema, was present in approximately 40% of cases. Secondary osteoarthritis, as a possible secondary disease after joint empyema, could be demonstrated and several risk factors for the primary empyema were identified.

5.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1199-1206, 2024 May.
Article in English | MEDLINE | ID: mdl-38511851

ABSTRACT

PURPOSE: The purpose of this study was to find out whether the torsions of the femur and tibia are dependent on the coronal plane alignment of the knee (CPAK) type. METHODS: Five hundred patients (1000 legs) were included, who received a whole leg standing three-dimensional (3D) radiograph using EOS imaging (EOS Imaging, Paris, France). SterEOS software was used for digital reconstruction. Femoral and tibial torsions were determined by analysing 3D reconstructions of each leg. Femoral torsion was defined as the angle between the femoral neck axis (FNA) and the posterior condylar axis (PCA). Tibial torsion was defined as the angle between the axis tangent to the posterior part of the tibia plateau and the transmalleolar axis. Arithmetic hip-knee-ankle angle (aHKA) and joint-line obliquity (JLO) were also determined, allowing each leg to be assigned one of nine possible phenotypes according to CPAK. RESULTS: The mean femoral torsion in CPAK type 1 was significantly higher (+ 2.6° ± 0.8°) than in CPAK type 4 (p = 0.02). All other CPAK types did not differ in the degree of femoral torsions. No differences could be demonstrated for the tibial torsion. CONCLUSION: There is a correlation between the coronal alignment of the lower limb and femoral torsion. This may provide the basis for extending the CPAK classification beyond the coronal plane. LEVEL OF EVIDENCE: Level III.


Subject(s)
Femur , Imaging, Three-Dimensional , Knee Joint , Tibia , Humans , Femur/diagnostic imaging , Femur/anatomy & histology , Female , Male , Adult , Knee Joint/diagnostic imaging , Middle Aged , Tibia/diagnostic imaging , Aged , Torsion Abnormality/diagnostic imaging , Young Adult , Radiography , Adolescent
6.
Sci Rep ; 14(1): 4546, 2024 02 24.
Article in English | MEDLINE | ID: mdl-38402230

ABSTRACT

Preparation of the femoral proximal medullary cavity by reaming is essential for intramedullary nail osteosynthesis and hip revision arthroplasty. The use of reamers sometimes exerts high torsional forces on the bone. Design and direction of rotation of the reamer are potential influencing factors. The aim of this biomechanical study is to evaluate the best combination of a right- or left-cutting reamer with a clockwise- or counterclockwise-rotating insert in terms of preparation and safety. Right- and left-cutting reamers with conical design were each introduced into five synthetic femurs in both clockwise and counterclockwise rotation with constant feed force. A specially constructed test system was used for this series of tests, with which the respective intramedullary channel were reamed step by step. This was then used to determine the required torque. In addition, the feed rate measurement was analyzed using a modified digital caliper. The feed rates of the reamers with rotation in the same direction as the cutting direction were significantly increased compared to rotation in the opposite cutting direction (CCRLC vs. CCRRC 76.8 ± 9.0 mm/s vs. 25.2 ± 8.3 mm/s and CRRC vs. CRLC 54.3 ± 12.3 mm/s vs. 19.3 ± 0.6 mm/s; p < 0.01). In contrast, the mean torque during the reaming process was identical in all four groups. When preparing the proximal femoral medullary cavity, especially in cases with fragile bone structure, the available reamers should be introduced in opposite rotation to the cutting direction to achieve a more controllable feed of the reamer. Left-cutting reamers represent an alternative, using them in the usual clockwise-rotating technique to reduce the risk of complications during reaming.


Subject(s)
Arthroplasty, Replacement, Hip , Femur , Femur/surgery , Lower Extremity/surgery , Mechanical Phenomena , Bone and Bones/surgery
7.
Int J Mol Sci ; 25(4)2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38396718

ABSTRACT

Previously, we demonstrated that renal denervation in pigs reduces renal glucose release during a hypoglycemic episode. In this study we set out to examine changes in side-dependent renal net glucose release (SGN) through unilateral low-frequency stimulation (LFS) of the renal plexus with a pulse generator (2-5 Hz) during normoglycemia (60 min) and insulin-induced hypoglycemia ≤3.5 mmol/L (75 min) in seven pigs. The jugular vein, carotid artery, renal artery and vein, and both ureters were catheterized for measurement purposes, blood pressure management, and drug and fluid infusions. Para-aminohippurate (PAH) and inulin infusions were used to determine side-dependent renal plasma flow (SRP) and glomerular filtration rate (GFR). In a linear mixed model, LFS caused no change in SRP but decreased sodium excretion (p < 0.0001), as well as decreasing GFR during hypoglycemia (p = 0.0176). In a linear mixed model, only hypoglycemic conditions exerted significant effects on SGN (p = 0.001), whereas LFS did not. In a Wilcoxon signed rank exact test, LFS significantly increased SGN (p = 0.03125) and decreased sodium excretion (p = 0.0017) and urinary flow rate (p = 0.0129) when only considering the first instance LFS followed a preceding period of non-stimulation during normoglycemia. To conclude, this study represents, to our knowledge, the first description of an induction of renal gluconeogenesis by LFS.


Subject(s)
Glucose , Hypoglycemia , Animals , Swine , Glucose/pharmacology , Hypoglycemic Agents/pharmacology , Kidney , Hypoglycemia/chemically induced , Sodium/pharmacology , Glomerular Filtration Rate , Blood Glucose
8.
Arch Orthop Trauma Surg ; 144(1): 433-438, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37530843

ABSTRACT

INTRODUCTION: The correct adjustment of leg length is a major goal in the implantation of total hip replacements (THRs). Differences in leg length can lead to functional impairment and patient dissatisfaction. By determining leg length at an early stage, before the patient is discharged from hospital, compensatory measures such as the production of special insoles or orthopaedic footwear can be initiated promptly if there is a difference in leg length. Due to shortening of the period of time spent in hospital, the traditional measurement of leg length in a standing position may be increasingly subject to error. A protective posture immediately after surgery or the presence of a twisted pelvis, for example, due to scoliotic spinal misalignments, falsifies the measurement result in the standing position. Here, the measurement of leg length in the supine position may prove to be accurate immediately postoperatively, regardless of potential sources of error, and is to be compared with measurement in the standing position versus radiological measurement on the AP pelvic survey. MATERIAL AND METHODS: The present retrospective study included 190 patients who had undergone primary total hip arthroplasty. The leg length difference (LLD) of the patients was determined pre- and postoperatively both in the supine and standing position and compared with the postoperative radiological pelvic survey image. RESULTS: Postoperatively, it was shown that the mean length measured was 0.35 mm too long in the supine position and 0.68 mm too short in the standing position (p value < 0.001). Determination of the average absolute measurement error produces a deviation of 4.06 mm in the standing and 4.51 mm in the supine position (p value 0.126). CONCLUSIONS: It is shown that the postoperative measurement of LLD in the supine and standing position is equally valid and sufficiently accurate, compared with the gold standard of measurement on a radiograph.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Arthroplasty, Replacement, Hip/methods , Standing Position , Retrospective Studies , Leg , X-Rays , Supine Position
9.
Sci Rep ; 13(1): 19886, 2023 11 14.
Article in English | MEDLINE | ID: mdl-37963967

ABSTRACT

Osteoporosis is underdiagnosed in patients undergoing total hip arthroplasty (THA). Bone mineral density measurement by dual-energy X-ray absorptiometry (DXA) is the gold standard, but indices on plain hip radiographs also seemed to be reliable screening tools in female or Asian ethnicities in previous studies. Given the lack of knowledge about male patients and Caucasian ethnicities, this study was conducted to evaluate plane hip radiographic indices as a screening tool for osteopenia and osteoporosis in Caucasian female and also male patients before undergoing THA. A retrospective analysis of 216 elderly patients with pre-existing DXA before hip arthroplasty was performed and four indices were calculated on plain hip radiographs: Canal-Flare-Index (CFI), Canal-Calcar-Ratio (CCR), Canal-Bone-Ratio (CBR) 7 and 10 cm below the lesser trochanter. They were correlated with femoral neck DXA T-scores by Pearson's correlation and intraclass correlation coefficient, and a ROC analysis was performed. A total of 216 patients (49.5% male) were included. CBR-7 and -10 were highly correlated (p < 0.001) with femoral neck T-score in males (Pearson's correlation CBR-7 r = - 0.60, CBR-10 r = - 0.55) and females (r = - 0.74, r = - 0.77). CBR-7 and -10 also showed good diagnostic accuracy for osteoporosis in the ROC analysis in males (CBR-7: AUC = 0.75, threshold = 0.51; CBR-10: 0.63; 0.50) and females (CBR-7: AUC = 0.87, threshold = 0.55; CBR-10: 0.90; 0.54). Indices such as the Canal Bone Ratio (CBR) 7 or 10 cm below the lesser trochanter on plain hip radiographs are a good screening tool for osteopenia and osteoporosis on plain hip radiographs and can be used to initiate further diagnostics like the gold standard DXA. They differ between male and female patients.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Diseases, Metabolic , Osteoporosis , Humans , Male , Female , Aged , Bone Density , Arthroplasty, Replacement, Hip/adverse effects , Retrospective Studies , Osteoporosis/diagnostic imaging , Absorptiometry, Photon , Bone Diseases, Metabolic/diagnostic imaging
10.
Int J Mol Sci ; 24(16)2023 Aug 13.
Article in English | MEDLINE | ID: mdl-37628918

ABSTRACT

Previously, we demonstrated in pigs that renal denervation halves glucose release during hypoglycaemia and that a prenatal dexamethasone injection caused increased ACTH and cortisol concentrations as markers of a heightened hypothalamic pituitary adrenal axis (HPAA) during hypoglycaemia. In this study, we investigated the influence of an altered HPAA on renal glucose release during hypoglycaemia. Pigs whose mothers had received two late-gestational dexamethasone injections were subjected to a 75 min hyperinsulinaemic-hypoglycaemic clamp (<3 mmol/L) after unilateral surgical denervation. Para-aminohippurate (PAH) clearance, inulin, sodium excretion and arterio-venous blood glucose difference were measured every fifteen minutes. The statistical analysis was performed with a Wilcoxon signed-rank test. PAH, inulin, the calculated glomerular filtration rate and plasma flow did not change through renal denervation. Urinary sodium excretion increased significantly (p = 0.019). Side-dependent renal net glucose release (SGN) decreased by 25 ± 23% (p = 0.004). At 25 percent, the SGN decrease was only half of that observed in non-HPAA-altered animals in our prior investigation. The current findings may suggest that specimens with an elevated HPAA undergo long-term adaptations to maintain glucose homeostasis. Nonetheless, the decrease in SGN warrants further investigations and potentially caution in performing renal denervation in certain patient groups, such as diabetics at risk of hypoglycaemia.


Subject(s)
Hypoglycemia , Hypoglycemic Agents , Female , Animals , Swine , Pregnancy , Glucose , Hypothalamo-Hypophyseal System , Inulin , Pituitary-Adrenal System , p-Aminohippuric Acid , Dexamethasone/adverse effects , Denervation
11.
J Clin Med ; 12(12)2023 Jun 12.
Article in English | MEDLINE | ID: mdl-37373700

ABSTRACT

Psychologic comorbidities have been identified as risk factors for poor outcomes in orthopedic procedures, but their influence on the outcome of hip-preserving periacetabular osteotomy (PAO) remains uncertain. This retrospective cohort study aimed to assess the impact of patients' psychological health on the outcome of PAO in patients with hip dysplasia (HD) and acetabular retroversion (AR). The study included 110 patients undergoing PAO for HD or AR between 2019 and 2021. Standardized questionnaires were administered to assess psychological factors, postoperative hip function, and activity level (mean follow-up: 25 months). Linear regression analyses were used to examine the associations between psychological factors and postoperative hip function and activity level. Both HD and AR patients showed improved postoperative hip function and activity levels. Linear regression analyses revealed that depression significantly impaired postoperative outcomes in both groups, whereas somatization negatively influenced the outcome in AR patients. General health perceptions significantly contributed to an improved postoperative outcome. These findings highlight the importance of concomitantly addressing psychologically relevant factors in order to improve patient outcomes after PAO procedures. Future prospective studies should continue to investigate the impact of various psychological factors and explore possibilities of incorporating psychological support into routine postoperative care for these patient cohorts.

12.
Surg Infect (Larchmt) ; 24(5): 482-487, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37222729

ABSTRACT

Background: The wearing of male facial hair has been undergoing something of a renaissance for a number of years, with medical colleagues in the surgical disciplines being no exception. Meanwhile, there are a few reports in the literature that beards might have an increased bacterial colonization. This study aims to determine if wearing a beard leads to an increased rate of infection in total hip or knee arthroplasty. Patients and Methods: A retrospective analysis was performed on 20,394 primary hip and knee replacements that were implanted at a single university hospital. The rate of infections that occurred within one year after surgery and the surgeons performing the surgery were recorded. The surgeons were classified into clean-shaven and beard wearers. The beard wearers were further classified by individual facial hair styles, namely a moustache, chin beard, round beard, or full beard. Results: The overall rate of surgical site infections 365 days after surgery is 0.75%. There was no statistically significant association between surgical site infection and the presence of facial hair (p = 0.774) or specific beard types (p = 0.298). Conclusions: The results presented in this study show no differences in infection rates across different facial hair styles of male surgeons.


Subject(s)
Arthroplasty, Replacement, Hip , Communicable Diseases , Hair , Surgeons , Surgical Wound Infection , Humans , Male , Face , Incidence , Retrospective Studies , Surgical Wound Infection/epidemiology
13.
Arch Orthop Trauma Surg ; 143(9): 5671-5676, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37099164

ABSTRACT

PURPOSE: Various anatomical landmarks have become established in radiography for the assessment of cup positioning after total hip arthroplasty (THA). The most important one is Koehler's teardrop figure (KTF). However, there is a lack of data on the validity of this landmark, which is widely used clinically for assessing the centre of rotation of the hip. METHOD: A retrospective measurement of the lateral and cranial distance of the KTF to the centre of hip rotation was performed on the basis of 250 X-ray images of patients who had undergone THA. In addition, the dependence of these distances on pelvic tilt was determined in 16 patients by means of virtual X-ray projections based on pelvic CTs. RESULTS: It was shown that the distance of the KTF from the centre of hip rotation in the horizontal plane is gender-dependent (men: 42.8 ± 6.0 mm vs. women: 37.4 ± 4.7 mm; p < 0.001) and age-dependent (Pearson correlation - 0.114; p < 0.05). Furthermore, the vertical and horizontal distances are subject to variation depending on height (Pearson correlation 0.14; p < 0.05 and 0.40; p < 0.001, respectively) and weight (Pearson correlation 0.158; p < 0.05). The distance between the KTF and the centre of hip rotation varies slightly depending on pelvic tilt. CONCLUSION: The KTF is not a sufficiently valid landmark for assessing the centre of rotation after THA. It is influenced by many different disturbance variables. However, it is largely robust against changes in pelvic tilt, so that it can be used as a reference point when comparing different intraindividual radiographs to assess the change in the centre of rotation due to implantation or to detect cup migration.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Male , Humans , Female , Arthroplasty, Replacement, Hip/methods , Retrospective Studies , Rotation , Radiography , Pelvis
14.
Orthopadie (Heidelb) ; 52(4): 272-281, 2023 Apr.
Article in German | MEDLINE | ID: mdl-36939881

ABSTRACT

BACKGROUND: Hip dysplasia is the most common cause of secondary hip osteoarthritis. The Ganz periacetabular osteotomy (PAO) is a well-established procedure that allows a reliable and reproducible correction of the complex pathology. The promising medium and long-term good treatment results are offset by the potential risk of complications from an invasive pelvic procedure. Considering the mainly young age of the patients, knowledge of the possible complications and the resulting adequate therapy is crucial. TREATMENT DEVELOPMENT: The continuous development of surgical techniques and increase in overall surgical experience alongside the appreciation of critical surgical steps have led to a substantial reduction of serious complications. In addition, to improve patient outcome, a greater understanding of the associated pathologies that may be related to hip dysplasia is essential.


Subject(s)
Hip Dislocation, Congenital , Hip Dislocation , Humans , Acetabulum/surgery , Hip Dislocation/etiology , Treatment Outcome , Retrospective Studies , Hip Dislocation, Congenital/complications , Osteotomy/adverse effects
15.
Arch Orthop Trauma Surg ; 143(8): 5249-5254, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36538161

ABSTRACT

INTRODUCTION: Vancomycin powder (VP) is an antibiotic first introduced in pediatric spinal surgery to prevent surgical site infections (SSI). Recently its topical application was expanded to total hip and knee arthroplasty (THA, TKA) and anterior cruciate ligament reconstruction (ACLR). Toxicity to cartilage is the subject of current research. The aim of this study was to prove the hypothesis that topical application of VP in TKA does not result in a degeneration of patella cartilage. We propagate that the conversion rate for secondary patella resurfacing is not influenced by its use. MATERIALS AND METHODS: Between 2014 and 2021, 4292 joints were included in this monocentric retrospective cohort study. All patients underwent TKA without primary patella resurfacing. After a change of the procedure in the hospital, one group (VPG) was administered VP intraoperatively. The other group (nVPG) received no VP during surgery (nVPG). The remaining perioperative procedure was constant over the investigation period. Conversion rates for secondary patella resurfacing for both groups were determined without making distinctions in the indication. A second cohort was composed of patients presenting for follow-up examination 12 months after TKA and included 210 joints. Retrospective radiographic evaluations were performed preoperatively, before discharge and at follow-up examination. Patella axial radiographs were analyzed for patella tracking (lateral patellar tilt, patellar displacement) and patella degeneration (Sperner classification, patellofemoral joint space). RESULTS: There was no significant difference in the conversion rate for secondary patella resurfacing (4.24% VPG, 4.97% nVPG). Patella tracking and patella degeneration did not differ significantly between both groups. CONCLUSIONS: The topical application of VP does not influence the conversion rate for secondary patella resurfacing. Moreover, it does not result in a degeneration of patella cartilage in TK. LEVEL OF EVIDENCE: Retrospective case series, Level III.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Child , Arthroplasty, Replacement, Knee/methods , Patella/surgery , Retrospective Studies , Vancomycin , Powders , Knee Joint/surgery , Treatment Outcome , Osteoarthritis, Knee/surgery
16.
Arch Orthop Trauma Surg ; 143(3): 1549-1569, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36450936

ABSTRACT

INTRODUCTION: Revision total knee arthroplasty (RTKA) has been increasing continuously. The results of RTKA still remain unsatisfactory. Failure patterns and risk factors in RTKA were thoroughly analyzed, with periprosthetic joint infections (PJI) and aseptic loosening remaining at the forefront of re-revision (ReRTKA) causes. While there is evidence that stem profile impacts the revisability of cemented implants, its association with the modes of RTKA failure is unknown. METHODS: 50 consecutive ReRTKA performed in a single orthopedic center during 2016-2017 were retrospectively analyzed. The cases were stratified according to age, sex, number of preexisting revisions, fixation technique, stem design and causes of re-revision. All explanted implants with conical vs. cylindrical stem profiles were compared. RESULTS: Mean age was 67 ± 11.5, and 54% were females. 72% of the cases had ≥ 3 previous revisions. 88% were full-cemented, 3% hybrid and 9% press-fit stems. 36% of the RTKA had conical, 58% cylindrical and 6% combined stem profiles. 92% of the RTKA components were removed. Removal causes were: PJI (52.2%), aseptic loosening (34.8%), implant malposition (9.8%), painful knee (1.1%) and instability (2.2%). While the overall RTKA failure patterns were equally distributed between conical and cylindrical stems, subgroup analysis of only cemented ReRTKA revealed a higher incidence of aseptic loosening within cylindrical stem profiles (46.7% vs. 25.7%, P = 0.05). CONCLUSION: Stem profile may have an impact on the process of aseptic loosening in cemented non-metaphyseal engaging RTKA, with cylindrical designs tending to worse outcomes than conical designs. Large cohort studies could provide more clarity on current observation.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Female , Humans , Middle Aged , Aged , Male , Arthroplasty, Replacement, Knee/adverse effects , Knee Prosthesis/adverse effects , Retrospective Studies , Prosthesis Failure , Reoperation/methods , Prosthesis Design
17.
Arch Orthop Trauma Surg ; 143(6): 3495-3503, 2023 Jun.
Article in English | MEDLINE | ID: mdl-35943586

ABSTRACT

INTRODUCTION: Periprosthetic joint infection (PJI) after total hip arthroplasty (THA) remains a serious complication in orthopaedic surgery. C-reactive protein (CRP) is widely used as a marker to screen for inflammatory complications. The early postoperative course is well known, but knowledge about the predictive value of CRP in the first 6 postoperative days for detecting an acute postoperative PJI is lacking. METHODS: We retrospectively analyzed the inpatient course of CRP of all primary THA and THA with acute PJI within 28 days in our hospital from 2013 to 2021. A receiver-operating curve (ROC) analysis was performed and the best CRP threshold for detecting an acute PJI based on Youden's-index was calculated and an area-under-the curve (AUC) analysis of the threshold was performed. RESULTS: 33 of 7042 patients included had an acute PJI within 28 days. Patients with acute PJI were older, had a higher BMI and longer operation time and suffered more often from diabetes mellitus. A preoperatively elevated CRP was a risk factor for PJI. CRP was significantly higher in the PJI group on postoperative days 3 and 5. Threshold values were calculated to be 152 mg/l on day 3 and 73 mg/l on day 5. However, these values had a low sensitivity (75%, 76%) and specificity (67%, 61%). CONCLUSION: Especially considering the decreasing length of stay after THA, the question of the usefulness of regular inpatient CRP checks arises. AUC analysis of the ROC showed a poor diagnostic accuracy in almost all cases. Only the dynamic analysis of the maximum CRP value to the lowest CRP value with a decrease of 102.7 mg/l showed a fair accuracy. This calls into question the clinical relevance of CRP in the first postoperative week for detection of acute postoperative PJI.


Subject(s)
Arthritis, Infectious , Arthroplasty, Replacement, Hip , Prosthesis-Related Infections , Humans , Arthroplasty, Replacement, Hip/adverse effects , C-Reactive Protein/analysis , Retrospective Studies , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/surgery , Risk Factors , Arthritis, Infectious/surgery , Biomarkers , Sensitivity and Specificity , Blood Sedimentation
18.
Orthopadie (Heidelb) ; 52(2): 159-164, 2023 Feb.
Article in German | MEDLINE | ID: mdl-36449049

ABSTRACT

OBJECTIVE: In total knee arthroplasty (TKA), range of motion has become established as an important factor. The criterion of quality is set to flexion of 90° after hospitalisation. Currently, it is supposed to be a predictor for 1­year postoperative outcome. However, as this correlation has not been proven, this clinical trial was performed. METHODS: A total of 182 TKA recipients were analysed retrospectively. Outcomes were assessed before surgery, after hospitalization, 6 weeks and 1 year post surgery. They included knee range of motion (ROM) to answer the main hypothesis, but also KSS, SF-36, WOMAC, EQ-5D and VAS to evaluate knee function and quality of life. The patients were divided into two groups differing in achieving 90° flexion after hospitalisation and compared 6 weeks and 1 year after surgery. RESULTS: Knee flexion differed significantly between groups from 91 to 70° in the group without the aim of 90° flexion after hospitalisation (E) (p < 0.001). After 6 weeks, flexion was improved to 112°â€¯± 13° (E > 90°) vs. 106°â€¯± 14° (E < 90°; p = 0.001). One year post surgery, knee flexion averaged 122°â€¯± 10° (E > 90°) vs. 120°â€¯± 10° (E < 90°) with no difference between the groups (p = 0.57) and no significant difference in all other scores concerning knee function and quality of life. CONCLUSION: Flexion of 90° after hospitalisation is not adequate to predict medium-term outcomes after TKA. There is no advantage or disadvantage regarding whether the aim of 90° flexion is achieved.


Subject(s)
Arthroplasty, Replacement, Knee , Humans , Hospitalization , Knee Joint/surgery , Quality of Life , Retrospective Studies
19.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1323-1333, 2023 Apr.
Article in English | MEDLINE | ID: mdl-35394135

ABSTRACT

PURPOSE: The number of primary total knee arthroplasties (TKA) is expected to rise constantly. For patients and healthcare providers, the early identification of risk factors therefore becomes increasingly fundamental in the context of precision medicine. Others have already investigated the detection of risk factors by conducting literature reviews and applying conventional statistical methods. Since the prediction of events has been moderately accurate, a more comprehensive approach is needed. Machine learning (ML) algorithms have had ample success in many disciplines. However, these methods have not yet had a significant impact in orthopaedic research. The selection of a data source as well as the inclusion of relevant parameters is of utmost importance in this context. In this study, a standardized approach for ML in TKA to predict complications during surgery and an irregular surgery duration using data from two German arthroplasty-specific registries was evaluated. METHODS: The dataset is based on two initiatives of the German Society for Orthopaedics and Orthopaedic Surgery. A problem statement and initial parameters were defined. After screening, cleaning and preparation of these datasets, 864 cases of primary TKA (2016-2019) were gathered. The XGBoost algorithm was chosen and applied with a hyperparameter search, a cross validation and a loss weighting to cope with class imbalance. For final evaluation, several metrics (accuracy, sensitivity, specificity, AUC) were calculated. RESULTS: An accuracy of 92.0%, sensitivity of 34.8%, specificity of 95.8%, and AUC of 78.0% were achieved for predicting complications in primary TKA and 93.4%, 74.0%, 96.3%, and 91.6% for predicting irregular surgery duration, respectively. While traditional statistics (correlation coefficient) could not find any relevant correlation between any two parameters, the feature importance revealed several non-linear outcomes. CONCLUSION: In this study, a feasible ML model to predict outcomes of primary TKA with very promising results was built. Complex correlations between parameters were detected, which could not be recognized by conventional statistical analysis. Arthroplasty-specific data were identified as relevant by the ML model and should be included in future clinical applications. Furthermore, an interdisciplinary interpretation as well as evaluation of the results by a data scientist and an orthopaedic surgeon are of paramount importance. LEVEL OF EVIDENCE: Level IV.


Subject(s)
Arthroplasty, Replacement, Knee , Orthopedics , Humans , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Machine Learning , Risk Assessment , Risk Factors
20.
Arch Orthop Trauma Surg ; 143(1): 489-493, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35037995

ABSTRACT

In total knee arthroplasty (TKA), the aim of achieving a mechanically straight leg axis as well as symmetrical and equally wide gaps has become established as the gold standard in terms of surgical technique. In contrast to TKA unicompartmental knee arthroplasty (UKA) is performed in anteromedial osteoarthritis (AMOA) and does not normally require releases. This raises the hypothesis whether the type of osteoarthritis (AMOA vs. posteromedial osteoarthritis (PMOA)) determines the requirement for soft tissue releases in TKA.In this retrospective study, 114 patients with medial osteoarthritis of the knee who had been treated with a navigated total knee replacement were consecutively included. On the basis of the preoperative lateral radiographs, the patients were divided into two groups: AMOA and PMOA. The incidence and the extent of releases performed were recorded using the navigation records.Patient-specific data (gender, age) did not differ between the groups (NS). Knees with AMOA presented an overall varus alignment of 5.3 ± 3.5°, knees with PMOA 8.0 ± 4.0° (p < 0.001). 30 cases (44%) had to be released in the AMOA group, compared with 33 cases (72%) in the PMOA group (p = 0.004). In the case of medial release, the extension gap increased 3.3 ± 2.4 mm in the AMOA compared to 5.3 ± 3.7 mm in the PMOA group (p = 0.006). The medial flexion gap was released 2.2 ± 2.6 mm in the AMOA and 2.9 ± 3.0 mm in the PMOA group (p = 0.008).To achieve a neutral mechanical alignment, a release has to be performed due to asymmetry of the extension gap more often if PMOA is present than in AMOA. Surgeons should be prepared to perform more frequent and extensive medial releases in PMOA. Higher constrained implants should be available in case of unintended over release in PMOA.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Osteoarthritis, Knee/surgery , Retrospective Studies , Knee Joint/surgery , Knee/surgery , Range of Motion, Articular
SELECTION OF CITATIONS
SEARCH DETAIL
...