Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 62
Filter
1.
J Clin Med ; 13(10)2024 May 15.
Article in English | MEDLINE | ID: mdl-38792462

ABSTRACT

Background/Objectives: Chronic total occlusion (CTO) is a prevalent finding in patients with coronary artery disease and is associated with increased mortality. Prior reports on the efficacy of percutaneous coronary intervention (PCI) compared to optimal medical therapy (OMT) were controversial. Following the emergence of recently published new evidence, a meta-analysis is warranted. The current meta-analysis assessed the effects of PCI compared to OMT in the treatment of CTO. Methods: A structured literature search was performed. Randomized controlled trials (RCTs) and non-randomized controlled studies of interventions were eligible. The primary outcome was an accumulated composite of cardiac mortality, myocardial infarction and target vessel/lesion revascularization events. Results: Thirty-two studies reporting on 11260 patients were included. Of these, 5712 (50.7%) were assigned to the PCI and 5548 (49.3%) were allocated to the OMT group. The primary outcome occurred in 14.6% of the PCI and 20.1% of the OMT group (12 trials, OR 0.66, 95% CI 0.50 to 0.88, p = 0.005, I2 = 67%). Subgrouping demonstrated a consistent reduction in the primary outcome for the PCI group in RCTs (six trials, OR 0.58, 95% CI 0.33 to 0.99, p = 0.05). The primary outcome reduction was irrespective of the study design, and it was replicable in sensitivity and subgroup analyses. Advantages in other outcomes were rather related to statistical pooling effects and dominated by observational data. Conclusions: CTO-PCI was associated with improved patient-oriented primary outcome compared to OMT in a study-level meta-analysis. This composite outcome effect was mainly driven by target vessel treatment, but a significant reduction in mortality and myocardial infarction was observed, irrespectively. These findings have hypothesis-generating implications. Future RCTs with adequate statistical power are eagerly awaited.

2.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38629416

ABSTRACT

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left , Humans , Aortic Valve/surgery , Heart Ventricles , Stroke Volume , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Ventricular Function, Left , Multicenter Studies as Topic , Clinical Studies as Topic
3.
Life (Basel) ; 14(4)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38672696

ABSTRACT

Transcatheter aortic valve replacement (TAVR) has become an established alternative to surgical aortic valve replacement (AVR) for patients with moderate-to-high perioperative risk. Periprocedural TAVR complications decrease with growing expertise of implanters. Nevertheless, TAVR can still be accompanied by life-threatening adverse events such as intraprocedural cardiopulmonary resuscitation (CPR). This study analyzed the role of a reduced left-ventricular ejection fraction (LVEF) in intraprocedural complications during TAVR. Perioperative and postoperative outcomes from patients undergoing TAVR in a high-volume center (600 cases per year) were analyzed retrospectively with regard to their left-ventricular ejection fraction. Patients with a reduced left-ventricular ejection fraction (EF ≤ 40%) faced a significantly higher risk of perioperative adverse events. Within this cohort, patients were significantly more often in need of mechanical ventilation (35% vs. 19%). These patients also underwent CPR (17% vs. 5.8%), defibrillation due to ventricular fibrillation (13% vs. 5.4%), and heart-lung circulatory support (6.1% vs. 2.5%) more often. However, these intraprocedural adverse events showed no significant impact on postoperative outcomes regarding in-hospital mortality, stroke, or in-hospital stay. A reduced preprocedural LVEF is a risk factor for intraprocedural adverse events. With respect to this finding, the identified patient cohort should be treated with more caution to prevent intraprocedural incidents.

4.
Eur Radiol ; 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38189982

ABSTRACT

BACKGROUND: Coronary artery disease (CAD) and severe aortic valve stenosis (AS) frequently coexist. While pre-transcatheter aortic valve replacement (TAVR) computed tomography angiography (CTA) allows to rule out obstructive CAD, interpreting hemodynamic significance of intermediate stenoses is challenging. This study investigates the incremental value of CT-derived fractional flow reserve (CT-FFR), quantitative coronary plaque characteristics (e.g., stenosis degree, plaque volume, and composition), and peri-coronary adipose tissue (PCAT) density to detect hemodynamically significant lesions among those with AS and CAD. MATERIALS AND METHODS: We included patients with severe AS and intermediate coronary lesions (20-80% diameter stenosis) who underwent pre-TAVR CTA and invasive coronary angiogram (ICA) with resting full-cycle ratio (RFR) assessment between 08/16 and 04/22. CTA image analysis included assessment of CT-FFR, quantitative coronary plaque analysis, and PCAT density. Coronary lesions with RFR ≤ 0.89 indicated hemodynamic significance as reference standard. RESULTS: Overall, 87 patients (age 77.9 ± 7.4 years, 38% female) with 95 intermediate coronary artery lesions were included. CT-FFR showed good discriminatory capacity (area under receiver operator curve (AUC) = 0.89, 95% confidence interval (CI) 0.81-0.96, p < 0.001) to identify hemodynamically significant lesions, superior to anatomical assessment, plaque morphology, and PCAT density. Plaque composition and PCAT density did not differ between lesions with and without hemodynamic significance. Univariable and multivariable analyses revealed CT-FFR as the only predictor for functionally significant lesions (odds ratio 1.28 (95% CI 1.17-1.43), p < 0.001). Overall, CT-FFR ≤ 0.80 showed diagnostic accuracy, sensitivity, and specificity of 88.4% (95%CI 80.2-94.1), 78.5% (95%CI 63.2-89.7), and 96.2% (95%CI 87.0-99.5), respectively. CONCLUSION: CT-FFR was superior to CT anatomical, plaque morphology, and PCAT assessment to detect functionally significant stenoses in patients with severe AS. CLINICAL RELEVANCE STATEMENT: CT-derived fractional flow reserve in patients with severe aortic valve stenosis may be a useful tool for non-invasive hemodynamic assessment of intermediate coronary lesions, while CT anatomical, plaque morphology, and peri-coronary adipose tissue assessment have no incremental or additional benefit. These findings might help to reduce pre-transcatheter aortic valve replacement invasive coronary angiogram. KEY POINTS: • Interpreting the hemodynamic significance of intermediate coronary stenoses is challenging in pre-transcatheter aortic valve replacement CT. • CT-derived fractional flow reserve (CT-FFR) has a good discriminatory capacity in the identification of hemodynamically significant coronary lesions. • CT-derived anatomical, plaque morphology, and peri-coronary adipose tissue assessment did not improve the diagnostic capability of CT-FFR in the hemodynamic assessment of intermediate coronary stenoses.

5.
Clin Res Cardiol ; 113(1): 107-115, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37524838

ABSTRACT

BACKGROUND: Many patients in need for transcatheter aortic valve implantation (TAVI) present with an aortic annulus size larger than recommended by the manufacturer's instructions for use (IFU). AIMS: To investigate procedural and short-term safety and efficacy of TAVI in patients with extra-large annuli (ELA). METHODS: 30-day clinical outcome and valve performance as defined by VARC 3 of 144 patients with an aortic annulus size exceeding the permitted range were compared to a propensity-score matched control cohort of patients with an aortic annulus size consistent with the IFU. RESULTS: Area and perimeter was 730.4 ± 53.9 mm2 and 96.7 ± 6.5 mm in the ELA group. Technical (96.5% vs. 94.4%) and device success (82.3% vs. 84.5%) were comparable in patients with ELA (annulus area 730.4 ± 53.9 mm2) and matched controls (annulus area 586.0 ± 48.2 mm2). There was no significant difference in 30-day mortality rate, major intraprocedural complications, type 3 or 4 bleedings, major vascular complications, or stroke. Moderate paravalvular leakage (PVL) occurred more frequent in the ELA group (8.9% vs 2.2%; p = 0.02). The rate of new pacemaker implantation was 7.0% in the ELA cohort and 15.0% in the control cohort, respectively (p = 0.05). CONCLUSION: Treatment of ELA patients with third-generation TAVI prostheses is feasible and safe, providing similar device success and complication rates as in matched controls with regular-sized aortic annulus. Post-interventional pacemaker implantation rates were low compared to the control group, yet incidence of moderate PVL remains problematic in ELA patients.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Feasibility Studies , Prosthesis Design , Treatment Outcome
6.
J Am Heart Assoc ; 12(24): e031881, 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38084735

ABSTRACT

BACKGROUND: We previously reported procedural and 30-day outcomes of a German early multicenter experience with the PASCAL system for severe mitral regurgitation (MR). This study reports 1-year outcomes of mitral valve transcatheter edge-to-edge repair with the PASCAL system according to MR etiology in a large all-comer cohort. METHODS AND RESULTS: Clinical and echocardiographic outcomes up to 1-year were investigated according to MR etiology (degenerative [DMR], functional [FMR], or mixed [MMR]) in the first 282 patients with symptomatic MR 3+/4+ treated with the PASCAL implant at 9 centers in 2019. A total of 282 patients were included (33% DMR, 50% FMR, 17% MMR). At discharge, MR reduction to ≤1+/2+ was achieved in 58%/87% of DMR, in 75%/97% of FMR, and in 78%/98% of patients with MMR (P=0.004). MR reduction to ≤1+/2+ was sustained at 30 days (50%/83% DMR, 67%/97% FMR, 74%/100% MMR) and at 1 year (53%/78% DMR, 75%/97% FMR, 67%/91% MMR) with significant differences between etiologies. DMR patients with residual MR 3+/4+ at 1-year had at least complex valve morphology in 91.7%. Valve-related reintervention was performed in 7.4% DMR, 0.7% FMR, and 0.0% MMR (P=0.010). At 1-year, New York Heart Association Functional Class was significantly improved irrespective of MR etiology (P<0.001). CONCLUSIONS: In this large all-comer cohort, mitral valve transcatheter edge-to-edge repair with the PASCAL system was associated with an acute and sustained MR reduction at 1-year in all causes. However, in patients with DMR, MR reduction was less pronounced, reflecting the high incidence of complex or very complex anatomies being referred for mitral valve transcatheter edge-to-edge repair.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/etiology , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Registries , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Cardiac Catheterization/adverse effects
7.
J Endovasc Ther ; : 15266028231204291, 2023 Oct 18.
Article in English | MEDLINE | ID: mdl-37853703

ABSTRACT

PURPOSE: Access-related vascular complications in transfemoral transcatheter aortic valve implantation (TAVI) can be treated endovascularly or surgically. The aim of this study was to evaluate the short- and long-term outcomes of endovascular treatment compared with surgical repair for access-related vascular complications. METHODS: This retrospective study was performed from January 1, 2018, to December 31, 2020. All transfemorally treated TAVI patients in whom a surgical or endovascular treatment for an access site complication was needed were included. The primary outcome was the need for any related vascular re-operation. RESULTS: In total, 1219 transfemoral TAVI procedures were conducted during the study period. 19 patients suffered an access complication requiring endovascular treatment, while 54 patients required surgical repair. No differences were seen with regard to re-operations (endovascular 15.8% vs surgical 14.8%; p=0.919), wound infections (endovascular 0% vs surgical. 11.1%; p=0.129), and wound healing disorders (endovascular 15.8% vs surgical 29.6%; p=0.237). Patients undergoing endovascular treatment were discharged earlier (endovascular 11.2 vs surgical 14.9 days; p=0.028). After surgical repair, patients received significantly more blood transfusions than endovascularly treated patients (endovascular 1.00 vs surgical 3.1 red blood cell concentrate bags; p<0.001). No differences were found regarding the new onset of walking pain, rest pain, and ischemic ulcers during follow-up. CONCLUSION: In this retrospective cohort, endovascular treatment of access-related vascular complications of transfemoral TAVI procedures was safe and feasible. During the hospital stay, endovascularly treated patients received fewer blood transfusions and were discharged faster than surgically treated patients. No differences regarding clinical outcomes and re-intervention rates were seen during the follow-up. CLINICAL IMPACT: Given the in this retrospective study demonstrated safety and feasibility of endovascular treatment for major access-related vascular complications, along with the in-hospital benefits and absence of follow-up disadvantages compared to surgical treatment, endovascular treatment should be considered in cases of major access-related vascular complications in transfemoral TAVI patients.

8.
Eur Heart J Case Rep ; 7(8): ytad323, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37534045

ABSTRACT

Graphical abstractReconstructed pre-hospital ECG, 25 mm/s 10 mm/mV.

10.
EuroIntervention ; 19(2): e176-e187, 2023 Jun 05.
Article in English | MEDLINE | ID: mdl-37013922

ABSTRACT

BACKGROUND: Reducing rates of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is important for achieving the best procedural outcomes. The cusp overlap technique (COT) implements procedural steps including an overlap angulation of the right and left coronary cusp to mitigate this complication. AIMS: We investigated the incidence of PPI and complication rates following the COT compared to the standard three-cusp implantation technique (3CT) in an all-comers cohort. METHODS: A total of 2,209 patients underwent TAVI with the self-expanding Evolut platform from January 2016 to April 2022 at five sites. Baseline, procedural and in-hospital outcome characteristics were compared for both techniques before and after one-to-one propensity score matching. RESULTS: A total of 1,151 patients were implanted using the 3CT and 1,058 using the COT. At discharge, the rates of PPI (17.0 vs 12.3%; p=0.002) and moderate/severe paravalvular regurgitation (4.6% vs 2.4%; p=0.006) were significantly reduced with the COT compared with 3CT within the unmatched cohort. Overall procedural success and complication rates were similar; major bleeding was less common in the COT group (7.0% vs 4.6%; p=0.020). These results remained consistent after propensity score matching. In multivariable logistic regression analysis, right bundle branch block (odds ratio [OR] 7.19, 95% confidence interval [CI]: 5.18-10.0; p<0.001) and diabetes mellitus (OR 1.38, 95% CI: 1.05-1.80; p=0.021) emerged as predictors of PPI, whereas the COT (OR 0.63, 95% CI: 0.49-0.82; p<0.001) was protective. CONCLUSIONS: The introduction of the COT was associated with a significant and relevant reduction of PPI and paravalvular regurgitation rates without an increase in complication rates.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Prosthesis Design , Risk Factors
11.
Hellenic J Cardiol ; 74: 1-7, 2023.
Article in English | MEDLINE | ID: mdl-37119968

ABSTRACT

OBJECTIVES: Left ventricular reverse remodeling (LVRR) is associated with improved outcome in patients with heart failure. Factors associated with and predictive of LVRR in patients with low-flow low-gradient aortic stenosis (LFLG AS) after transcatheter aortic valve implantation (TAVI) and its impact on outcome were assessed. METHODS: Pre- and postprocedural left ventricular (LV) function and volume were investigated in 219 patients with LFLG. LVRR was defined as an absolute increase of ≥10% in LV ejection fraction (LVEF) and reduction of ≥15% in LV end-systolic volume (LVESV). The primary endpoint was the combination of all-cause mortality and rehospitalization for heart failure. RESULTS: The mean LVEF was 35.0 ± 10.0%, with a stroke volume index (SVI) of 25.9 ± 6.0 mL/m2 and LVESV of 94.04 ± 46.0 mL. At a median of 5.2 months (interquartile range, 2.7-8.1 months), 77.2% (n = 169) of the patients showed echocardiographic evidence of LVRR. A multivariate model revealed three independent factors for LVRR after TAVI: SVI of <25 mL/m2 (hazard ratio [HR], 2.31; 95% confidence interval [CI], 1.08-3.58; p < 0.01), LVEF of <30% (HR, 2.76; 95% CI, 1.53-2.91; p < 0.01), and valvulo-arterial impedance (Zva) of <5 mmHg/mL/m2 (HR, 5.36; 95% CI, 1.80-15.98; p < 0.01). Patients without evidence of LVRR showed a significantly higher incidence of the 1-year combined endpoint (32 [64.0%] vs. 75 [44.4%], p < 0.01). CONCLUSIONS: The majority of patients with LFLG AS show LVRR after TAVI, which is associated with favorable outcomes. An SVI of <25 mL/m2, LVEF of <30%, and Zva < 5mmHg/mL/m2 represent predictors of LVRR.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Retrospective Studies , Ventricular Function, Left , Stroke Volume , Heart Failure/complications , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Ventricular Remodeling , Severity of Illness Index
12.
Clin Res Cardiol ; 112(9): 1220-1230, 2023 Sep.
Article in English | MEDLINE | ID: mdl-36602599

ABSTRACT

BACKGROUND: Non-hyperemic pressure ratios (NHPRs) like resting full-cycle ratio (RFR), diastolic pressure ratio during entire diastole (dPR[entire]) and diastolic pressure ratio during wave-free period (dPR[WFP]) are increasingly used to guide revascularization. The effect of NHPRs on mid-term prognosis has not been well established. OBJECTIVE: We investigated the prognostic implications of NHRPs in patients whose revascularization was deferred based on fractional flow reserve (FFR) in a single-centre population. METHODS: NHPRs and FFR were calculated offline from pressure tracings by an independent core laboratory. Follow-up data were acquired through records of hospital visits or telephone interviews. The primary outcome was a vessel-oriented composite outcome (VOCO) (a composite of cardiac death, vessel-related myocardial infarction, and ischemia-driven revascularization) in deferred vessels at 2 years. RESULTS: 316 patients with 377 deferred lesions were analysed. Discordance of NHPRs and FFR was found in 13.0-18.3% of lesions. The correlation coefficient between NHPRs was 0.99 (95% confidence interval 0.99-1.00). At 2 years, VOCO occurred in 19 lesions (5.0%). Estimated glomerular filtration rate < 30 mL/min/1.73 m2 [hazard ratio (HR) 5.7, p = 0.002], previous myocardial infarction (HR 3.3, p = 0.018), diabetes (HR 2.7, p = 0.042), RFR ≤ 0.89 (HR 2.7, p = 0.041) and dPR[WFP] ≤ 0.89 (HR 2.7, p = 0.049) were associated with higher incidence of VOCO at 2 years in the univariable analysis. A non-significant trend was found for dPR[entire] (HR 1.9, p = 0.26). CONCLUSION: A positive RFR or dPR[WFP] were associated with a worse prognosis in deferred lesions, suggesting that the use of NHPRs in addition to FFR may improve risk estimation.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Fractional Flow Reserve, Myocardial , Myocardial Infarction , Humans , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Prognosis , Blood Pressure , Coronary Angiography , Cardiac Catheterization , Predictive Value of Tests
13.
Int J Cardiol ; 377: 1-8, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36693476

ABSTRACT

BACKGROUND: Vessel fractional flow reserve (vFFR) is a novel angiography-derived index for the assessment of myocardial ischemia without the need for pressure wires and hyperemic agents. vFFR has demonstrated very good diagnostic performance compared with the hyperemic index fractional flow reserve (FFR). The aim of this study was to compare vFFR to the non-hyperemic pressure ratio resting full-cycle ratio (RFR). METHODS: This was a retrospective, observational, single-center study of an all-comer cohort undergoing RFR assessment. Invasive coronary angiography was obtained without a dedicated vFFR acquisition protocol, and vFFR calculation was attempted in all vessels interrogated by RFR (1483 lesions of 1030 patients). RESULTS: vFFR could be analyzed in 986 lesions from 705 patients. Median diameter stenosis was 37% (interquartile range (IQR): 30.0-44.0%), vFFR 0.86 (IQR: 0.81-0.91) and RFR 0.94 (IQR: (0.90-0.97). The correlation between vFFR and RFR was strong (r = 0.70, 95% confidence interval (CI): 0.66-0.74, p < 0.001). Using RFR ≤0.89 as reference, the sensitivity, specificity, positive predictive value, negative predictive value, and overall diagnostic accuracy for vFFR were 77%, 93%, 77%, and 92% and 89%. vFFR yielded a high area under the curve (AUC) of 0.92 (95% CI: 0.90-0.94). The good diagnostic performance of vFFR was confirmed among subgroups of patients with diabetes, severe aortic stenosis, female gender and lesions located in the left anterior descending artery. CONCLUSION: vFFR has a high diagnostic performance taking RFR as the reference standard for evaluating the functional significance of coronary stenoses.


Subject(s)
Coronary Angiography , Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Female , Humans , Coronary Artery Disease/diagnosis , Coronary Stenosis , Coronary Vessels , Heart , Hyperemia , Predictive Value of Tests , Severity of Illness Index
14.
Thorac Cardiovasc Surg ; 71(2): 94-100, 2023 03.
Article in English | MEDLINE | ID: mdl-34521136

ABSTRACT

OBJECTIVE: This study aimed to assess short-term outcomes of patients with failed aortic valve bioprosthesis undergoing valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) or redo surgical aortic valve replacement (rSAVR). METHODS: Between 2009 and 2019, 90 patients who underwent ViV-TAVR (n = 73) or rSAVR (n = 17) due to failed aortic valve bioprosthesis fulfilled the inclusion criteria. Groups were compared regarding clinical end points, including in-hospital all-cause mortality. Patients with endocarditis and in a need of combined cardiac surgery were excluded from the study. RESULTS: ViV-TAVR patients were older (78.0 ± 7.4 vs. 62.1 ± 16.2 years, p = 0.012) and showed a higher prevalence of baseline comorbidities such as atrial fibrillation, diabetes mellitus, hyperlipidemia, and arterial hypertension. In-hospital all-cause mortality was higher for rSAVR than in the ViV-TAVR group (17.6 vs. 0%, p < 0.001), whereas intensive care unit stay was more often complicated by blood transfusions for rSAVR patients without differences in cerebrovascular events. The paravalvular leak was detected in 52.1% ViV-TAVR patients compared with 0% among rSAVR patients (p < 0.001). CONCLUSION: ViV-TAVR can be a safe and feasible alternative treatment option in patients with degenerated aortic valve bioprosthesis. The choice of treatment should include the patient's individual characteristics considering ViV-TAVR as a standard of care.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Risk Factors , Reoperation , Prosthesis Failure , Treatment Outcome , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Bioprosthesis/adverse effects
15.
Thorac Cardiovasc Surg ; 71(2): 101-106, 2023 03.
Article in English | MEDLINE | ID: mdl-35853463

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become an established alternative to surgical aortic valve replacement (AVR) for higher risk patients. Periprocedural TAVR complications decreased with a growing expertise of implanters. Yet, TAVR can be accompanied by life-threatening adverse events such as intraprocedural cardiopulmonary resuscitation (CPR). This study retrospectively analyzed predictors and outcomes in a cohort of patients from a high-volume center undergoing periprocedural CPR during TAVR. METHODS: A total of 729 patients undergoing TAVR, including 59 with intraprocedural CPR, were analyzed with respect to peri- and postprocedural outcomes. RESULTS: Patients undergoing CPR showed a significantly lower left ventricular ejection fraction (LVEF) and lower baseline transvalvular mean and peak pressure gradients. The systolic blood pressure measured directly preoperatively was significantly lower in the CPR cohort. CPR patients were in a higher need for intraprocedural defibrillation, heart-lung circulatory support, and conversion to open heart surgery. Further, they showed a higher incidence of atrioventricular block grade III , valve malpositioning, and pericardial tamponade. The in-hospital mortality was significantly higher after intraprocedural CPR, accompanied by a higher incidence of disabling stroke, new pacemaker implantation, more red blood cell transfusion, and longer stay in intensive care unit. CONCLUSION: Impaired preoperative LVEF and instable hemodynamics before valve deployment are independent risk factors for CPR and are associated with compromised outcomes. Heart rhythm disturbances, malpositioning of the prosthesis, and pericardial tamponade are main causes of the high mortality of 17% reported in the CPR group. Nevertheless, mechanical circulatory support and conversion to open heart surgery reduce mortality rates of CPR patients.


Subject(s)
Aortic Valve Stenosis , Cardiac Tamponade , Cardiopulmonary Resuscitation , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Stroke Volume/physiology , Ventricular Function, Left , Retrospective Studies , Cardiac Tamponade/complications , Cardiac Tamponade/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Risk Factors , Cardiopulmonary Resuscitation/adverse effects
16.
Hellenic J Cardiol ; 70: 1-9, 2023.
Article in English | MEDLINE | ID: mdl-36538975

ABSTRACT

OBJECTIVE: Several supra-annular self-expanding transcatheter systems are commercially available for transcatheter aortic valve implantation (TAVI). Comparative data in large-scale multicenter studies are scant. METHODS: This study included a total of 5175 patients with severe aortic stenosis undergoing TAVI with the ACURATE neo (n = 1095), Evolut R (n = 3365), or Evolut PRO (n = 715) by a transfemoral approach at five high-volume centers. Propensity score matching resulted in 654 triplets. Outcomes are reported according to the Valve Academic Research Consortium-3 (VARC-3) consensus. RESULTS: Moderate or severe paravalvular regurgitation (PVR) occurred significantly more often in the ACURATE neo group (5.2%) than in the Evolut R (1.8%) and Evolut PRO (3.3%) groups (p = 0.003). The rates of major vascular-/access-related complications (4.6%, 3.8%, and 5.0%; p = 0.56), type 3 or 4 bleeding (3.2%, 2.1%, and 4.1%; p = 0.12), and 30-day mortality (2.4%, 2.6%, and 3.7%; p = 0.40) were comparable. The rate of new permanent pacemaker implantation (PPI) was significantly lower in the ACURATE neo group (9.5%, 17.6%, and 16.8%; p < 0.001). Independent predictors for 2-year survival were a Society of Thoracic Surgeons (STS) risk score ≥5%, diabetes mellitus, a glomerular filtration rate <30 ml/min, baseline mean transvalvular gradient ≤ 30 mm Hg, treating center, and relevant PVR. CONCLUSION: In this multicenter study, TAVI with the ACURATE neo, Evolut R, or Evolut PRO was feasible and safe. The rate of relevant PVR was more frequent after the ACURATE neo implantation, with, however, lower rates of PPI. Two-year survival was mainly driven by baseline comorbidities.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Propensity Score , Prosthesis Design , Treatment Outcome
17.
Clin Cardiol ; 46(1): 67-75, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36259730

ABSTRACT

BACKGROUND: Despite major advances, transcatheter aortic valve replacement (TAVR) is still associated with procedure-specific complications. Although previous studies reported lower bleeding rates in patients receiving protamine for heparin reversal, the optimal protamine-to-heparin dosing ratio is unknown. HYPOTHESIS: The aim of this study was a comparison of two different heparin antagonization regimens for the prevention of bleeding complications after TAVR. METHODS: The study included 1446 patients undergoing TAVR, of whom 623 received partial and 823 full heparin antagonization. The primary endpoint was a composite of 30-day mortality, life-threatening, and major bleeding. Safety endpoints included stroke and myocardial infarction at 30 days. RESULTS: Full antagonization of heparin resulted in lower rates of the primary endpoint as compared to partial heparin reversal (5.6% vs. 10.4%, p < .01), which was mainly driven by lower rates of life-threatening (0.5% vs. 1.6%, p = .05) and major bleeding (3.2% vs. 7.5%, p < .01). Moreover, the incidence of major vascular complications was significantly lower in patients with full heparin reversal (3.5% vs. 7.5%, p < .01). The need for red-blood-cell transfusion was lower in patients receiving full as compared to partial heparin antagonization (10.4% vs. 15.9%, p < .01). No differences were observed in the incidence of stroke and myocardial infarction between patients with full and partial heparin reversal (2.2% vs. 2.6%, p = .73 and 0.2% vs. 0.4%, p = .64, respectively). CONCLUSIONS: Full heparin antagonization resulted in significantly lower rates of life-threatening and major bleeding after TAVR as compared to partial heparin reversal. The occurrence of stroke and myocardial infarction was low and comparable between both groups.


Subject(s)
Aortic Valve Stenosis , Myocardial Infarction , Stroke , Transcatheter Aortic Valve Replacement , Humans , Heparin/adverse effects , Transcatheter Aortic Valve Replacement/adverse effects , Protamines/adverse effects , Risk Factors , Treatment Outcome , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Stroke/prevention & control , Stroke/chemically induced , Myocardial Infarction/prevention & control , Myocardial Infarction/complications , Aortic Valve/surgery
18.
Clin Res Cardiol ; 112(5): 571-584, 2023 May.
Article in English | MEDLINE | ID: mdl-36107228

ABSTRACT

BACKGROUND: Transcatheter mitral valve implantation (TMVI) with self-expanding (SAV) or balloon-expandable (BAV) valves are rising as promising treatment options for high-risk patients with symptomatic mitral valve (MVD) disease unsuitable for alternative treatment options. AIMS: The aim of this study was to examine the clinical, procedural and outcome parameters of patients undergoing SAV or BAV for MVD. METHODS: In this observational and single-center case series, fifteen consecutive patients treated with the Tendyne Mitral Valve System (SAV) and thirty-one patients treated with SAPIEN prosthesis (BAV) were included. RESULTS: The patients (aged 78 years [interquartile range (IQR): 65.5 to 83.1 years], 41% women, EuroSCORE II 10.3% [IQR: 5.5 to 17.0%] were similar regarding baseline characteristics, despite a higher rate of prior heart valve surgery and prevalence of MV stenosis in the SAV-group. At discharge, the SAV-group had a mean transvalvular gradient of 4.2 mmHg, whereas the BAV-group had a mean transvalvular gradient of 6.2 mmHg. None or trace paravalvular leakage (PVL) was assessed in 85% in SAV-group and 80% in the BAV-group. 320 day all-cause and cardiac mortality rates were comparable in both groups (SAV: 26.7% vs BAV: 20%, p = 0.60). Four deaths occurred early in the SAV-group until 32 days of follow-up. CONCLUSIONS: In high-risk patients with MVD, TMVI presents a promising treatment option with encouraging mid-term outcomes and good valve durability. TMVI either with BAV or SAV may be developed to an established treatment option.


Subject(s)
Aortic Valve Stenosis , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Prosthesis Design
20.
JACC Cardiovasc Interv ; 15(24): 2541-2551, 2022 12 26.
Article in English | MEDLINE | ID: mdl-36543448

ABSTRACT

BACKGROUND: In addition to the edge-to-edge MitraClip repair system, the edge-to-spacer PASCAL repair system was approved for percutaneous treatment of severe mitral regurgitation (MR). Comparative data are lacking. OBJECTIVES: The aim of this study was to compare procedural and short-term safety and efficacy of 2 leaflet-based transcatheter mitral valve repair systems. METHODS: Procedural and 30-day outcomes were investigated in a propensity score-matched cohort of 307 PASCAL and 307 MitraClip patients at 10 sites. Matching criteria included sex, age, left ventricular ejection fraction, New York Heart Association functional class, MR etiology, left ventricular end-diastolic diameter, left atrial volume index, and vena contracta width. The primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE). RESULTS: Technical success was 97.0% in the PASCAL group and 98.0% in the MitraClip group (P = 0.624). MR ≤2+ at discharge was comparable in both groups (PASCAL: 93.8% vs MitraClip: 92.4%; P = 0.527), with more patients exhibiting MR ≤1+ in the PASCAL group (70.5% vs 56.6%; P < 0.001). The postprocedural mean gradient was significantly higher in the MitraClip group (3.3 ± 1.5 mm Hg vs 3.9 ± 1.7 mm Hg; P < 0.001). At 30 days, all-cause mortality and MAE rates were similar (mortality: 1.7% vs 3.3%; P = 0.299; MAE: 3.9% vs 5.2%; P = 0.562). CONCLUSIONS: In this first large propensity score-matched comparison, procedural success rates and MAE did not differ significantly between patients treated with the PASCAL or MitraClip valve repair system. Procedural results with less than moderate MR and no elevated transmitral gradient were more common in the PASCAL group, which might have an impact on long-term outcome.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Heart Valve Prosthesis Implantation/adverse effects , Stroke Volume , Propensity Score , Ventricular Function, Left , Treatment Outcome , Cardiac Catheterization/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...