Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 230
Filter
1.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38646926

ABSTRACT

AIMS: Using thermal-based energy sources [radiofrequency (RF) energy/cryo energy] for catheter ablation is considered effective and safe when performing pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF). However, treatment success remains limited and complications can occur due to the propagation of thermal energy into non-target tissues. We aim to compare pulsed field ablation (PFA) with RF ablation in terms of efficacy and safety for patients with drug-resistant paroxysmal AF. METHODS AND RESULTS: The BEAT PAROX-AF trial is a European multicentre, superiority, open-label randomized clinical trial in two parallel groups. A total of 292 participants were recruited in 9 high-volume European clinical centres in 5 countries. Patients with paroxysmal AF were randomized to PFA (FARAPULSE Endocardial Ablation System©, Boston Scientific) or RF using the CLOSE protocol with contact force sensing catheter (SmartTouch© catheter and CARTO© Biosense Webster). The primary endpoint will be the 1-year recurrence of atrial arrhythmia, and the major secondary safety endpoint will be the occurrence of acute (<7 days) procedure-related serious adverse events, or pulmonary vein stenosis, or atrio-oesophageal fistula up to 12 months. Additionally, five sub-studies investigate the effect of PFA on oesophageal safety, cerebral lesions, cardiac autonomic nervous system, durability of PVI as assessed during redo ablation procedures, and atrial and ventricular function. The study began on 27 December 2021 and concluded recruitment on 17 January 2024. Results will be available in mid-2025. CONCLUSION: The BEAT PAROX-AF trial aims to provide critical insights into the optimal treatment approach for patients with paroxysmal AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Catheter Ablation/methods , Treatment Outcome , Pulmonary Veins/surgery , Female , Male , Recurrence , Europe , Middle Aged
2.
PLoS One ; 19(4): e0301753, 2024.
Article in English | MEDLINE | ID: mdl-38578782

ABSTRACT

BACKGROUND: Atrial arrhythmias (AA) commonly affect patients with cardiac amyloidosis (CA) and are a contributing risk factor for the development of heart failure (HF). This study sought to investigate the long-term efficacy and impact of catheter ablation on HF progression in patients with CA and AA. METHODS: Thirty-one patients with CA and AA undergoing catheter ablation were retrospectively included (transthyretin-ATTR CA 61% and light chain-AL CA 39%). AA subtypes included atrial fibrillation (AFib) in 22 (paroxysmal in 10 and persistent in 12), atrial flutter (AFl) in 17 and atrial tachycardia (AT) in 11 patients. Long-term AA recurrence rates were evaluated along with the impact of sinus rhythm (SR) maintenance on HF and mortality. RESULTS: AA recurrence was observed in 14 patients (45%) at a median of 3.5 months (AFib n = 8, AT n = 6, AFl = 0). Post-cardioversion, medical therapy or catheter ablation, 10 patients (32%) remained in permanent AA. Over a median follow-up of 19 months, all-cause mortality was 39% (n = 12): 3 with end-stage HF, 5 due to late complications of CA, 1 sudden cardiac death, 1 stroke, 1 COVID 19 (and one unknown). With maintenance of SR following catheter ablation, significant reductions in serum creatinine and natriuretic peptide levels were observed with improvements in NYHA class. Two patients required hospitalization for HF in the SR maintenance cohort compared to 5 patients in the AA recurrence cohort (p = 0.1). All 3 patients with deaths secondary to HF had AA recurrence compared to 11 out of the 28 patients whom were long-term survivors or deaths not related to HF (p = 0.04). All-cause mortality was not associated with AA recurrence. CONCLUSION: This study demonstrates moderate long-term efficacy of SR maintenance with catheter ablation for AA in patients with CA. Improvements in clinical and biological status with positive trends in HF mortality are observed if SR can be maintained.


Subject(s)
Amyloidosis , Atrial Fibrillation , Catheter Ablation , Heart Failure , Tachycardia, Supraventricular , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/surgery , Retrospective Studies , Treatment Outcome , Neoplasm Recurrence, Local/surgery , Heart Failure/complications , Heart Failure/surgery , Amyloidosis/complications , Amyloidosis/surgery , Catheter Ablation/adverse effects
3.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38584423

ABSTRACT

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Subject(s)
Defibrillators, Implantable , Heart Failure , Tachycardia, Ventricular , Humans , Risk Factors , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Incidence , Heart Failure/complications , Asia/epidemiology , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/therapy , Tachycardia, Ventricular/complications
4.
Arch Cardiovasc Dis ; 117(4): 244-248, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38490843

ABSTRACT

BACKGROUND: The true incidence of sudden death remains undetermined, with controversial results from various publications over time and countries. AIM: To investigate if different estimations would reach the values usually reported for France. METHODS: Three different kinds of estimations were used. First, the number of resuscitated sudden deaths and necropsies for sudden death in the Haute-Garonne French administrative department (i.e. county) over the last 10years was expanded to the national level. Second, sudden death coding of death certificates was collected at the national level. Third, the total number of out-of-hospital cardiac arrests leading to any emergency call (with/without intervention) in Haute-Garonne over the last 10years was expanded to the national level. RESULTS: There was a mean of 26 resuscitated sudden deaths and 145 necropsies for sudden death each year in Haute-Garonne, i.e. 12 to 14 sudden deaths for 100,000 inhabitants, and 7700 to 9400 sudden deaths yearly when related to the whole French population, according to the year of inclusion. Based on death certificates, a mean of 6584 sudden deaths was registered each year in France. Finally, there were about 600 yearly calls/interventions for out-of-hospital cardiac arrests in Haute-Garonne, i.e. 40 to 50 sudden deaths for 100,000 inhabitants, and 16,000 to 27,000 sudden deaths yearly for the whole French territory, according to the year of inclusion. CONCLUSIONS: The incidence of sudden death ranges from 6500 to 27,000 in France according to the calculation methods. This huge difference raises the question of the true current incidence of sudden death, which may have been overestimated previously or may be underestimated in France. More straight prospective surveys are needed to solve this question, because of relevant implications for priorities that should be given to sudden death.


Subject(s)
Out-of-Hospital Cardiac Arrest , Humans , Out-of-Hospital Cardiac Arrest/diagnosis , Out-of-Hospital Cardiac Arrest/epidemiology , Out-of-Hospital Cardiac Arrest/therapy , Incidence , Prospective Studies , Death, Sudden , France/epidemiology , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control
5.
Arch Cardiovasc Dis ; 117(4): 249-254, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38494400

ABSTRACT

BACKGROUND: Pulsed field ablation has recently emerged as an interesting non-thermal energy for atrial fibrillation ablation. At a time of rapid spread of this technology, there is still a lack of prospective real-life data. AIM: To describe multicentre prospective safety and 1-year efficacy data in three of the first French centres to use pulsed field ablation. METHODS: All consecutive patients undergoing a first pulsed field ablation were included prospectively. The primary outcome was freedom from documented atrial arrhythmia. The safety endpoint was a composite of major adverse events. Univariate and multivariable analyses, including patient and procedural characteristics, were performed to identify factors predictive of recurrence. RESULTS: Between May 2021 and June 2022, 311 patients were included (paroxysmal atrial fibrillation in 53%, persistent atrial fibrillation in 35% and long-standing persistent atrial fibrillation in 11%). Additional non-pulmonary vein pulsed field ablation applications were performed in 104/311 patients. One-year freedom from arrhythmia recurrence was 77.6% in the overall population and was significantly higher in patients with paroxysmal atrial fibrillation (88.4%) compared with patients with persistent atrial fibrillation (69.7%; P<0.001) and those with long-standing persistent atrial fibrillation (49.0%; P<0.001). The major complication rate was 2.6% (tamponade in four patients, stroke in two patients and coronary spasm in one patient). Besides the usual predictors of recurrences (left atrium size, CHA2DS2-VASc score, type of atrial fibrillation), the presence of atrial fibrillation at procedure start was independently associated with arrhythmia recurrence (hazard ratio: 2.04, 95% confidence interval: 1.10-3.77). CONCLUSION: In this prospective multicentre real-world study, pulsed field ablation for atrial fibrillation ablation seems to be associated with a good safety profile and rather favourable acute and 1-year success rates.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Prospective Studies , Treatment Outcome , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
6.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Article in English | MEDLINE | ID: mdl-38430087

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Male , Female , Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Middle Aged , Retrospective Studies , Heart Atria/surgery , Pulmonary Veins/surgery , Treatment Outcome , Registries
9.
JACC Clin Electrophysiol ; 10(3): 502-511, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38206261

ABSTRACT

BACKGROUND: Desmoplakin (DSP) pathogenic variants are rare causes of arrhythmogenic cardiomyopathy and often involve the right and left ventricles. Ventricular tachycardia (VT) ablations may be required in these patients, but procedural characteristics have not been reported. OBJECTIVES: In this study, the authors sought to report a multicenter experience of VT ablation in patients with DSP pathogenic variants. METHODS: VT ablations performed in patients with known DSP pathogenic variants were analyzed across 6 centers in 3 countries. Patient characteristics and acute and long-term procedural outcomes were reported. RESULTS: A total of 20 patients (13 men, median age 43 years [Q1-Q3: 41.5-53.0 years], left ventricular ejection fraction 43.0% [Q1-Q3: 41.5%-53.0%], 11 previous failed ablations) were referred for VT ablation procedures. All patients had symptomatic VTs, with ICD therapy in 19 patients. Epicardial procedures were performed in 16 of the 20 patients. VT target sites were located in the right ventricular (RV) endocardium (n = 11), the RV epicardium (n = 4), the left ventricular (LV) endocardium (n = 2) and the LV epicardium (n = 7). In 3 patients, the VT target sites were in close proximity to coronary arteries, limiting ablation. During follow-up, VTs recurred in 11 patients, and repeated ablations were performed in 9 patients. Allowing for multiple procedures, 19 of the 20 patients remained free of VT recurrence after a median follow-up of 18 months [Q1-Q3: 5-60 months]. CONCLUSIONS: Patients with DSP cardiomyopathy often have biventricular involvement, and ablation procedures often require ablation in both ventricles and the epicardium. Recurrences are not uncommon, and the pathologic substrate can be located in close proximity to epicardial coronary arteries, limiting the success rate of ablations.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Cardiomyopathies , Catheter Ablation , Tachycardia, Ventricular , Male , Humans , Adult , Desmoplakins/genetics , Stroke Volume , Arrhythmogenic Right Ventricular Dysplasia/complications , Arrhythmogenic Right Ventricular Dysplasia/surgery , Ventricular Function, Left , Cardiomyopathies/complications , Cardiomyopathies/surgery , Catheter Ablation/methods
10.
Heart Rhythm ; 21(3): 313-320, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37956775

ABSTRACT

BACKGROUND: The efficacy of beta-blocker treatment in type 3 long QT syndrome (LQT3) remains debated. OBJECTIVES: The purpose of this study was to test the hypothesis that beta-blocker use is associated with cardiac events (CEs) in a French cohort of LQT3 patients. METHODS: All patients with a likely pathogenic/pathogenic variant in the SCN5A gene (linked to LQT3) were included and followed-up. Documented ventricular tachycardia/ventricular fibrillation, torsades de pointes, aborted cardiac arrest, sudden death, and appropriate shocks were considered as severe cardiac events (SCEs). CEs also included syncope. RESULTS: We included 147 patients from 54 families carrying 23 variants. Six of the patients developed symptoms before the age of 1 year and were analyzed separately. The 141 remaining patients (52.5% male; median age at diagnosis 24.0 years) were followed-up for a median of 11 years. The probabilities of a CE and an SCE from birth to the age of 40 were 20.5% and 9.9%, respectively. QTc prolongation (hazard ratio [HR] 1.12 [1.0-1.2]; P = .005]) and proband status (HR 4.07 [1.9-8.9]; P <.001) were independently associated with the occurrence of CEs. Proband status (HR 8.13 [1.7-38.8]; P = .009) was found to be independently associated with SCEs, whereas QTc prolongation (HR 1.11 [1.0-1.3]; P = .108) did not reach statistical significance. The cumulative probability of the age at first CE/SCE was not lower in patients treated with a beta-blocker. CONCLUSION: In agreement with the literature, proband status and lengthened QTc were associated with a higher risk of CEs. Our data do not show a protective effect of beta-blocker treatment.


Subject(s)
Heart Arrest , Long QT Syndrome , Humans , Male , Young Adult , Adult , Female , Electrocardiography , Long QT Syndrome/drug therapy , Long QT Syndrome/genetics , Long QT Syndrome/diagnosis , Syncope , Heart Arrest/complications , Adrenergic beta-Antagonists/therapeutic use
11.
Europace ; 25(12)2023 12 06.
Article in English | MEDLINE | ID: mdl-38051977

ABSTRACT

AIMS: Correlations between malignant ventricular arrhythmias and the COVID waves have never been investigated. METHODS AND RESULTS: Prevalence of malignant ventricular arrhythmias/sudden cardiac death has been correlated to the four COVID waves between the onset of pandemic and end 2021. No significant correlation was present in the temporal evolution of both COVID patients/positive tests and incidence of malignant ventricular arrhythmias, which tended to decrease after vaccination onset. CONCLUSION: We present evidence of complex higher-order periodicities and the co-existence of such regions with stable non-chaotic areas in ex vivo human hearts. We infer that the oscillation of the calcium cycling machinery is the primary mechanism of higher-order dynamics. These higher-order regions may act as niduses of instability and may provide targets for substrate-based ablation of VF.


Subject(s)
COVID-19 , Pandemics , Humans , COVID-19/epidemiology , COVID-19/complications , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Heart , Death, Sudden, Cardiac/epidemiology
12.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37910101

ABSTRACT

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Subject(s)
Atrial Fibrillation , Humans , Male , Female , Middle Aged , Aged , Adolescent , Atrial Fibrillation/drug therapy , Retrospective Studies , Cohort Studies , Sex Factors , Treatment Outcome
13.
Sensors (Basel) ; 23(21)2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37960599

ABSTRACT

Short QT syndrome (SQTS) is an inherited cardiac ion-channel disease related to an increased risk of sudden cardiac death (SCD) in young and otherwise healthy individuals. SCD is often the first clinical presentation in patients with SQTS. However, arrhythmia risk stratification is presently unsatisfactory in asymptomatic patients. In this context, artificial intelligence-based electrocardiogram (ECG) analysis has never been applied to refine risk stratification in patients with SQTS. The purpose of this study was to analyze ECGs from SQTS patients with the aid of different AI algorithms to evaluate their ability to discriminate between subjects with and without documented life-threatening arrhythmic events. The study group included 104 SQTS patients, 37 of whom had a documented major arrhythmic event at presentation and/or during follow-up. Thirteen ECG features were measured independently by three expert cardiologists; then, the dataset was randomly divided into three subsets (training, validation, and testing). Five shallow neural networks were trained, validated, and tested to predict subject-specific class (non-event/event) using different subsets of ECG features. Additionally, several deep learning and machine learning algorithms, such as Vision Transformer, Swin Transformer, MobileNetV3, EfficientNetV2, ConvNextTiny, Capsule Networks, and logistic regression were trained, validated, and tested directly on the scanned ECG images, without any manual feature extraction. Furthermore, a shallow neural network, a 1-D transformer classifier, and a 1-D CNN were trained, validated, and tested on ECG signals extracted from the aforementioned scanned images. Classification metrics were evaluated by means of sensitivity, specificity, positive and negative predictive values, accuracy, and area under the curve. Results prove that artificial intelligence can help clinicians in better stratifying risk of arrhythmia in patients with SQTS. In particular, shallow neural networks' processing features showed the best performance in identifying patients that will not suffer from a potentially lethal event. This could pave the way for refined ECG-based risk stratification in this group of patients, potentially helping in saving the lives of young and otherwise healthy individuals.


Subject(s)
Arrhythmias, Cardiac , Artificial Intelligence , Humans , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/complications , Neural Networks, Computer , Electrocardiography/methods , Death, Sudden, Cardiac/etiology
14.
JACC Clin Electrophysiol ; 9(12): 2550-2557, 2023 12.
Article in English | MEDLINE | ID: mdl-37804261

ABSTRACT

BACKGROUND: In a preliminary study in patients hospitalized for catheter ablation of atrial fibrillation (AF), the atrial thrombus exclusion (ATE) score (stroke, hypertension, heart failure, and D-dimers >270 ng/mL) was developed to rule out the diagnosis of intra-atrial thrombus, with a negative predictive value (NPV) of 100%, and to avoid performing transesophageal echocardiography (TEE). OBJECTIVES: The present study was designed to prospectively confirm the NPV of the ATE score in an independent population. METHODS: Consecutive patients hospitalized for catheter ablation of AF or left atrial tachycardia (LAT) were prospectively enrolled in a multicenter study. D-dimer levels were measured within 48 hours before ablation. An ATE score of 0 was considered predictive of no thrombus. TEE was routinely performed at the beginning or just before the ablation procedure. The primary endpoint was the presence of atrial thrombus diagnosed by TEE. RESULTS: The analysis included 3,072 patients (53.3% paroxysmal AF, 36.7% persistent AF, and 10% LAT). A thrombus was detected in 29 patients (0.94%; 95% CI: 0.63%-1.35%), all on appropriate anticoagulant therapy. An ATE score of 0 was observed in 818 patients (26.6%), and the sensitivity, specificity, positive predictive value, and NPV were 93.1%, 26.8%, 1.2%, and 99.8%, respectively. Follow-up of the 2 false negative patients revealed the persistence of chronic organized thrombi. CONCLUSIONS: In patients hospitalized for catheter ablation of AF or LAT, the ATE score identifies a population at very low risk for atrial thrombus. In consultation with the patient, the cardiologist may consider not performing a preoperative TEE in case of an ATE score of 0.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Heart Diseases , Thrombosis , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Atria/diagnostic imaging , Heart Diseases/diagnosis , Thrombosis/epidemiology
15.
Pacing Clin Electrophysiol ; 46(12): 1546-1552, 2023 12.
Article in English | MEDLINE | ID: mdl-37885373

ABSTRACT

BACKGROUND: Efficiency and safety of ablation using half normal saline (HNS) has been shown in refractory ventricular tachycardia (VT), but no evaluation in unselected larger populations has been made. OBJECTIVE: To evaluate the efficiency and safety of systematic HNS ablation in VT ablation. METHODS: All successive VT ablations in patients with structural heart disease from 2018 to 2021 used HNS in our center and were retrospectively included. RESULTS: One hundred seventy-seven successive VT ablation procedures using HNS have been performed in 148 patients (91% males, mean 64 ± 12 years, ischemic cardiomyopathy 64%, left ventricular ejection fraction 38 ± 13%). A mean of 19 ± 7.5 min of RF was delivered, with a mean power of 44 ± 7 W. Relevant complications happened in 9% (strokes 2%, tamponades 3%, atrioventricular block during septal ablations 5%). Over a mean follow-up of 15 ± 9 months, VT recurred in 46%. Final recurrence rate after one or several procedures was 36% (18 months follow-up). Number of VT episodes decreased from 14 ± 35 before to 2.5 ± 10 after ablation (p < .0001) and number of ICD shocks decreased from 4.8 ± 6.8 to 1.5 ± 0.8 (p = .027). CONCLUSION: Systematic use of HNS during VT ablations in patients with structural heart disease leads to long-term recurrences rates and complications in the range of what is reported using normal saline. Although controlled studies are needed for demonstrating the superiority of such attitude, the use of HNS in every scar-related VT ablation seems safe for standard cases and may be furthermore useful in case of refractory arrhythmias due to difficult-to-ablate substrates.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Male , Humans , Female , Saline Solution , Stroke Volume , Retrospective Studies , Ventricular Function, Left , Heart Diseases/etiology , Catheter Ablation/methods , Treatment Outcome , Recurrence
16.
Front Cardiovasc Med ; 10: 1167738, 2023.
Article in English | MEDLINE | ID: mdl-37731529

ABSTRACT

Background: Cardiogenic shock (CS) is the most severe form of heart failure (HF), resulting in high early and long-term mortality. Characteristics of CS secondary to supraventricular tachycardia (SVT) are poorly reported. Based on a large registry of unselected CS, we aimed to compare 1-year outcomes between SVT-triggered and non-SVT-triggered CS. Methods: FRENSHOCK is a French prospective registry including 772 CS patients from 49 centers. For each patient, the investigator could report 1-3 CS triggers from a pre-established list (ischemic, mechanical complications, ventricular/supraventricular arrhythmia, bradycardia, iatrogenesis, infection, non-compliance, and others). In this study, 1-year outcomes [rehospitalizations, mortality, heart transplantation (HTx), ventricular assist devices (VAD)] were analyzed and adjusted for independent predictive factors. Results: Among 769 CS patients included, 100 were SVT-triggered (13%), of which 65 had SVT as an exclusive trigger (8.5%). SVT-triggered CS patients exhibited a higher proportion of male individuals with a more frequent history of cardiomyopathy or chronic kidney disease and more profound CS (biventricular failure and multiorgan failure). At 1 year, there was no difference in all-cause mortality (43% vs. 45.3%, adjusted HR 0.9 (95% CI 0.59-1.39), p = 0.64), need for HTx or VAD [10% vs. 10%, aOR 0.88 (0.41-1.88), p = 0.74], or rehospitalizations [49.4% vs. 44.4%, aOR 1.24 (0.78-1.98), p = 0.36]. Patients with SVT as an exclusive trigger presented more 1-year rehospitalizations [52.8% vs. 43.3%, aOR 3.74 (1.05-10.5), p = 0.01]. Conclusion: SVT is a frequent trigger of CS alone or in association in more than 10% of miscellaneous CS cases. Although SVT-triggered CS patients were more comorbid with more pre-existing cardiomyopathies and HF incidences, they presented similar rates of mortality, HTx, and VAD at 1 year, arguing for a better overall prognosis. Clinical Trial Registration: https://clinicaltrials.gov, identifier: NCT02703038.

17.
Eur Heart J Acute Cardiovasc Care ; 12(9): 571-581, 2023 Sep 25.
Article in English | MEDLINE | ID: mdl-37319361

ABSTRACT

AIMS: Heart transplantation (HT) can be proposed as a therapeutic strategy for patients with severe refractory electrical storm (ES). Data in the literature are scarce and based on case reports. We aimed at determining the characteristics and survival of patients transplanted for refractory ES. METHODS AND RESULTS: Patients registered on HT waiting list during the following days after ES and eventually transplanted, from 2010 to 2021, were retrospectively included in 11 French centres. The primary endpoint was in-hospital mortality. Forty-five patients were included [82% men; 55.0 (47.8-59.3) years old; 42.2% and 26.7% non-ischaemic dilated or ischaemic cardiomyopathies, respectively]. Among them, 42 (93.3%) received amiodarone, 29 received (64.4%) beta blockers, 19 (42.2%) required deep sedation, 22 had (48.9%) mechanical circulatory support, and 9 (20.0%) had radiofrequency catheter ablation. Twenty-two patients (62%) were in cardiogenic shock. Inscription on wait list and transplantation occurred 3.0 (1.0-5.0) days and 9.0 (4.0-14.0) days after ES onset, respectively. After transplantation, 20 patients (44.4%) needed immediate haemodynamic support by extracorporeal membrane oxygenation (ECMO). In-hospital mortality rate was 28.9%. Predictors of in-hospital mortality were serum creatinine/urea levels, need for immediate post-operative ECMO support, post-operative complications, and surgical re-interventions. One-year survival was 68.9%. CONCLUSION: Electrical storm is a rare indication of HT but may be lifesaving in those patients presenting intractable arrhythmias despite usual care. Most patients can be safely discharged from hospital, although post-operative mortality remains substantial in this context of emergency transplantation. Larger studies are warranted to precisely determine those patients at higher risk of in-hospital mortality.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Transplantation , Male , Humans , Middle Aged , Female , Retrospective Studies , Arrhythmias, Cardiac/etiology , Shock, Cardiogenic/etiology , Extracorporeal Membrane Oxygenation/methods
18.
PLoS One ; 18(5): e0285802, 2023.
Article in English | MEDLINE | ID: mdl-37196034

ABSTRACT

AIMS: Factors underlying clinical tolerance and hemodynamic consequences of monomorphic sustained ventricular tachycardia (VT) need to be clarified. METHODS: Intra-arterial pressures (IAP) during VT were collected in patients admitted for VT ablation and correlated to clinical, ECG and baseline echocardiographical parameters. RESULTS: 114 VTs from 58 patients were included (median 67 years old, 81% ischemic heart disease, median left ventricular ejection fraction 30%). 61 VTs were untolerated needing immediate termination (54%). VT tolerance was tightly linked to the evolution of IAPs. Faster VT rates (p<0.0001), presence of resynchronization therapy (p = 0.008), previous anterior myocardial infarction (p = 0.009) and more marginally larger baseline QRS duration (p = 0.1) were independently associated with VT tolerance. Only an inferior myocardial infarction was more often present in patients with only tolerated VTs vs patients with only untolerated VTs in multivariate analysis (OR 3.7, 95% CI 1.4-1000, p = 0.03). In patients with both well-tolerated and untolerated VTs, a higher VT rate was the only variable independently associated with untolerated VT (p = 0.02). Two different patterns of hemodynamic profiles during VT could be observed: a regular 1:1 relationship between electrical (QRS) and mechanical (IAP) events or some dissociation between both. VT with the second pattern were more often untolerated compared to the first pattern (78% vs 29%, p<0.0001). CONCLUSION: This study helps to explain the large variability in clinical tolerance during VT, which is clearly related to IAP. VT tolerance may be linked to resynchronization therapy, VT rate, baseline QRS duration and location of myocardial infarction.


Subject(s)
Catheter Ablation , Myocardial Infarction , Tachycardia, Ventricular , Humans , Aged , Stroke Volume , Ventricular Function, Left , Myocardial Infarction/complications , Echocardiography
19.
Circulation ; 148(1): 35-46, 2023 07 04.
Article in English | MEDLINE | ID: mdl-37199171

ABSTRACT

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Pulmonary Veins , Humans , Female , Middle Aged , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/drug therapy , Retrospective Studies , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Atrial Flutter/etiology , Registries , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
20.
Eur Heart J ; 44(27): 2458-2469, 2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37062040

ABSTRACT

AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Treatment Outcome , Incidence , Risk Factors , Esophageal Fistula/epidemiology , Esophageal Fistula/etiology , Esophageal Fistula/diagnosis , Prognosis , Catheter Ablation/adverse effects , Catheter Ablation/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...