JSES Int ; 8(4): 756-762, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39035644

ABSTRACT

Background: Intramedullary nail fixation for proximal humerus fractures has been shown to provide satisfactory results. The quality of reduction correlates with clinical outcomes, the rate of complications, avascular necrosis, and postoperative loss of fixation. The purpose of this study was to evaluate the clinical outcomes and complications of 2-part proximal humerus fractures compared to 3- or 4-part proximal humerus fractures. Methods: A single-center retrospective review was carried out of patients who underwent an intramedullary nail for a proximal humerus fracture by one of three surgeons between the years of 2009 and 2022, and who had a minimum of 12-months follow-up. Fracture pattern, American Shoulder and Elbow Surgeons score, Single Assessment Numeric Evaluation score, satisfaction, pain score, range of motion, and complications were recorded. The mechanism of injury (high energy vs. low energy), method of reduction (open vs. percutaneous), and evidence of radiographic healing were assessed. A P value of <.05 was considered to be statistically significant. Results: The study included 78 patients (62 female, 16 male). The number of patients in each group (2-part, N = 32 vs. 3- or 4-part, N = 46), mean age (2-part, 64 vs. 3- or 4-part,61), follow-up (2-part, 42.5 months vs. 3- or 4-part, 34.5 months), injury type (2-part, 88% low energy vs. 3- or 4-part, 78% low energy), and method of reduction (2-part, 81% percutaneous vs. 3- or 4-part 72% percutaneous) were similar among the two groups. There was fracture union in all patients. All patients demonstrated satisfactory patient-reported outcome measures. However, 2-part fractures did have a significantly lower pain score, higher Single Assessment Numeric Evaluation score, and higher percentage of patients being satisfied or very satisfied when compared to 3- or 4-part fractures. The rate of subsequent procedures was 13% (n = 4) in 2-part fractures compared to 19% (n = 9) in 3- or 4-part fractures but was not statistically significant (P = .414). The overall rate of conversion to arthroplasty was 3.2% in 2-part fractures and 10.4% in 3- or 4-part fractures. Conclusion: Multipart proximal humerus fractures remain difficult to treat. However, this study demonstrates an overall acceptable outcome with improvement in range of motion, patient-reported outcomes, and similar complication rates between 2-part and 3- or 4-part proximal humerus fractures treated with an intramedullary nail. However, the improvement in certain parameters is not as marked in 3- or 4-part fractures as 2-part fractures.

2.
J Shoulder Elbow Surg ; 33(4): 872-879, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37689103

ABSTRACT

BACKGROUND: Current methods available for assessment of radiolucency and in-between fin (IBF) growth of a glenoid component have not undergone interobserver reliability testing for an all-polyethylene fluted central peg (FCP) glenoid. The purpose of this study was to evaluate anteroposterior radiographs of an FCP glenoid component at ≥48 months comparing commonly used scales to a new method adapted to the FCP. Our hypothesis was that the new method would result in acceptable intra- and interobserver agreement and a more accurate description of radiographic findings. METHODS: We reviewed ≥48-month follow-up radiographs of patients treated with a primary aTSA using an FCP glenoid. Eighty-three patients were included in the review. Radiographs were evaluated by 5 reviewers using novel IBF radiodensity and radiolucency assessments and the Wirth and Lazarus methods. To assess intraobserver reliability, a subset of 40 images was reviewed. Kappa statistics were calculated to determine intra- and interobserver reliability; correlations were assessed using Pearson correlation. RESULTS: Interobserver agreement (κ score) was as follows: IBF 0.71, radiolucency 0.68, Wirth 0.48, and Lazarus 0.22. Intraobserver agreement ranges were as follows: IBF radiodensity 0.36-0.67, radiolucency 0.55-0.62, Wirth 0.11-0.73, and Lazarus 0.04-0.46. Correlation analysis revealed the following: IBF to Wirth r = 0.93, radiolucency to Lazarus r = 0.92 (P value <.001 for all). CONCLUSION: This study introduces a radiographic assessment method developed specifically for an FCP glenoid component. Results show high interobserver and acceptable intraobserver reliability for the method presented in this study. The new scales provide a more accurate description of radiographic findings, helping to identify glenoid components that may be at risk for loosening.


Subject(s)
Arthroplasty, Replacement, Shoulder , Arthroplasty, Replacement , Glenoid Cavity , Joint Prosthesis , Shoulder Joint , Humans , Polyethylene , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Arthroplasty, Replacement/methods , Reproducibility of Results , Follow-Up Studies , Treatment Outcome , Prosthesis Design , Glenoid Cavity/diagnostic imaging , Glenoid Cavity/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...