1.
Invest Radiol ; 59(3): 223-229, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37493286

ABSTRACT

OBJECTIVES: Temporomandibular disorders (TMDs) are common and may cause persistent functional limitations and pain. Magnetic resonance imaging (MRI) at 1.5 and 3 T is commonly applied for the evaluation of the temporomandibular joint (TMJ). No evidence is available regarding the feasibility of modern low-field MRI for the assessment of TMDs. The objective of this prospective study was to evaluate the image quality (IQ) of 0.55 T MRI in direct comparison with 1.5 T MRI. MATERIALS AND METHODS: Seventeen patients (34 TMJs) with suspected intraarticular TMDs were enrolled, and both 0.55 and 1.5 T MRI were performed on the same day. Two senior readers independently evaluated the IQ focusing on the conspicuity of disc morphology (DM), disc position (DP), and osseous joint morphology (OJM) for each joint. We analyzed the IQ and degree of artifacts using a 4-point Likert scale (LS) at both field strengths. A fully sufficient IQ was defined as an LS score of ≥3. Nonparametric Wilcoxon test for related samples was used for statistical comparison. RESULTS: The median IQ for the DM and OJM at 0.55 T was inferior to that at 1.5 T (DM: 3 [interquartile range {IQR}, 3-4] vs 4 [IQR, 4-4]; OJM: 3 [IQR, 3-4] vs 4 [IQR 4-4]; each P < 0.001). For DP, the IQ was comparable (4 [IQR 3-4] vs 4 [IQR 4-4]; P > 0.05). A sufficient diagnostic IQ was maintained for the DM, DP, and OJM in 92% of the cases at 0.55 T and 100% at 1.5 T. Minor image artifacts (LS score of ≥3) were more prevalent at 0.55 T (29%) than at 1.5 T (12%). CONCLUSIONS: Magnetic resonance imaging of the TMJ at 0.55 T yields a lower IQ than does MRI at 1.5 T but maintains sufficient diagnostic confidence in the majority of patients. Further improvements are needed for reliable clinical application.


Subject(s)
Temporomandibular Joint Disc , Temporomandibular Joint Disorders , Humans , Temporomandibular Joint Disc/pathology , Prospective Studies , Temporomandibular Joint/anatomy & histology , Temporomandibular Joint/pathology , Temporomandibular Joint Disorders/diagnostic imaging , Temporomandibular Joint Disorders/pathology , Magnetic Resonance Imaging/methods
2.
Invest Radiol ; 59(3): 215-222, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37490031

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate the accuracy of modern low-field magnetic resonance imaging (MRI) for lung nodule detection and to correlate nodule size measurement with computed tomography (CT) as reference. MATERIALS AND METHODS: Between November 2020 and July 2021, a prospective clinical trial using low-field MRI at 0.55 T was performed in patients with known pulmonary nodules from a single academic medical center. Every patient underwent MRI and CT imaging on the same day. The primary aim was to evaluate the detection accuracy of pulmonary nodules using MRI with transversal periodically rotated overlapping parallel lines with enhanced reconstruction in combination with coronal half-Fourier acquired single-shot turbo spin-echo MRI sequences. The secondary outcome was the correlation of the mean lung nodule diameter with CT as reference according to the Lung Imaging Reporting and Data System. Nonparametric Mann-Whitney U test, Spearman rank correlation coefficient, and Bland-Altman analysis were applied to analyze the results. RESULTS: A total of 46 participants (mean age ± SD, 66 ± 11 years; 26 women) were included. In a blinded analysis of 964 lung nodules, the detection accuracy was 100% for those ≥6 mm (126/126), 80% (159/200) for those ≥4-<6 mm, and 23% (147/638) for those <4 mm in MRI compared with reference CT. Spearman correlation coefficient of MRI and CT size measurement was r = 0.87 ( P < 0.001), and the mean difference was 0.16 ± 0.9 mm. CONCLUSIONS: Modern low-field MRI shows excellent accuracy in lesion detection for lung nodules ≥6 mm and a very strong correlation with CT imaging for size measurement, but could not compete with CT in the detection of small nodules.


Subject(s)
Lung Neoplasms , Multiple Pulmonary Nodules , Humans , Female , Prospective Studies , Tomography, X-Ray Computed/methods , Lung/diagnostic imaging , Lung/pathology , Multiple Pulmonary Nodules/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods
3.
Eur J Radiol ; 167: 111078, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37688917

ABSTRACT

OBJECTIVES: This study evaluates the impact of a scanner-integrated, customized clinical decision support system (CDSS) on the acquisition technique, scan range, and reconstruction in thoracoabdominal CT. MATERIALS AND METHODS: We applied CDSS in contrast-enhanced examinations of the trunk with various clinical indications on a recent scanner with the capability of dual-energy CT (DECT), anatomic landmark detection (ALD), and iterative metal-artifact reduction (MAR). Simple and comprehensive questions about the patient's breath hold capability, the anatomical region of interest, and metal implants can be answered after the localizer. The acquisition technique (single energy, SECT, or dual energy), scan range (chest-abdomen-pelvis or chest-abdomen), and reconstruction technique (with or without MAR) were then automatically adapted in the examination protocols in coherence with these selections. Retrospectively, we compared the usage rates for these techniques in 624 examinations on the study scanner with 740 examinations on a comparable scanner without CDSS. Subgroup analysis of effective dose (ED), scan duration, and image quality (IQ) was performed in the study group. RESULTS: CDSS leads to an increased usage rate of DECT (64.4% vs. 2.8%) and MAR (75.4% vs. 44.0%). All scan range adaptations by ALD were successful. The resulting subjective IQ between single energy and DECT acquisitions was comparable (all p > 0.05). Scan duration was significantly longer in DECT than in SECT (16.9 s vs. 6.5 s; p < 0.001). However, the objective IQ was significantly higher in DECT (CNRD 2.1 vs. 1.8; p < 0.01), and the ED significantly lower (6.7 mSv vs. 7.6 mSv; p = 0.004). CONCLUSION: CDSS for thoracoabdominal CT leads to a substantially increased usage rate of innovative techniques during acquisition and reconstruction. Patients with adapted protocols benefit from improved image quality and increased post-processing options at lower radiation doses.


Subject(s)
Decision Support Systems, Clinical , Humans , Retrospective Studies , Anatomic Landmarks , Breath Holding , Tomography, X-Ray Computed
4.
Eur J Radiol ; 165: 110927, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37379624

ABSTRACT

OBJECTIVES: Vestibular schwannoma (VS) is the most common mass of the internal auditory canal (IAC) and is responsible for unilateral sensorineural hearing loss. Magnetic resonance imaging (MRI) at 1.5 T and 3 T is the standard of care for the evaluation of VS, and the feasibility of using modern low-field MRI for imaging of the IAC has not yet been elucidated. Hence, the purpose of this prospective study was to assess image quality and diagnostic performance of a modern 0.55 T MRI. MATERIALS AND METHODS: Fifty-six patients with known unilateral VS underwent routine MRI of the IAC at 1.5 T, followed immediately by 0.55 T MRI. Two radiologists independently evaluated the image quality, conspicuity of VS, diagnostic confidence, and image artifacts separately for isotropic T2-weighted SPACE images and for transversal and coronal T1-weighted fat-saturated contrast-enhanced images at 1.5 T and 0.55 T using 5-point Likert scales. In a second independent reading, both readers assessed lesion conspicuity and subjective diagnostic confidence in a direct comparison of 1.5 T and 0.55 T images. RESULTS: Image quality of transversal T1-weighted images (p = 0.13 and p = 0.16 for Reader 1 and Reader 2, respectively) and T2-weighted SPACE images (p = 0.39 and p = 0.58) were rated equally at 1.5 T and 0.55 T by both readers, whereas image quality of coronal T1-weighted images was superior at 1.5 T (p = 0.009 and p = 0.001). Analysis of the conspicuity of VS, diagnostic confidence, and image artifacts of all sequences revealed no significant differences between 1.5 T and 0.55 T. In the direct comparison of 1.5 T with 0.55 T images, there were no significant differences in lesion conspicuity or diagnostic confidence for any sequence (p = 0.60-0.73). CONCLUSIONS: Modern low-field MRI at 0.55 T provided a sufficient diagnostic image quality and seems feasible for the evaluation of VS of the IAC.


Subject(s)
Neuroma, Acoustic , Humans , Neuroma, Acoustic/diagnostic imaging , Prospective Studies , Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Artifacts , Contrast Media
5.
Clin Case Rep ; 11(5): e7349, 2023 May.
Article in English | MEDLINE | ID: mdl-37215974

ABSTRACT

Key Clinical Message: Complex presentations of MCS patients may necessitate a multidisciplinary approach involving HF cardiologists, CT surgeons, advanced cardiac imagers, and interventional cardiologists in order to define the optimal management strategy. Abstract: Left ventricle assist devices (LVADs) provide life-sustaining treatment for patients with terminal heart failure, but their intricacy allows for complications. One complication is LVAD outflow graft obstruction due to the graft's intraluminal thrombus or extraluminal compression. It may be treated endovascularly with stenting. We report an endovascular stenting of an outflow tract in HVAD™ (HeartWare Inc.) due to a pseudoaneurysm causing compression and kinking stenosis.

6.
J Cardiothorac Surg ; 18(1): 60, 2023 Feb 04.
Article in English | MEDLINE | ID: mdl-36739433

ABSTRACT

BACKGROUND: Pericardial tamponade (PT) early after cardiac surgery is a challenging clinical entity, not infrequently misrecognized and often only detected late in its course. Because the clinical signs of pericardial tamponade can be very unspecific, a high degree of initial suspicion is required to establish the diagnosis. In addition to clinical examination the deployment of imaging techniques is almost always mandatory in order to avoid delays in diagnosis and to initiate any necessary interventions, such as pericardiocentesis or direct cardiac surgical interventions. After a brief overview of how knowledge of PT has developed throughout history, we report on an atypical life-threatening cardiac tamponade after cardiac surgery. A 74-year-old woman was admitted for elective biological aortic valve replacement and aorto-coronary-bypass grafting (left internal mammary artery to left anterior descending artery, single vein graft to right coronary artery). On the 10th postoperative day, the patient unexpectedly deteriorated. She rapidly developed epigastric pain radiating to the left upper abdomen, and features of low peripheral perfusion and shock. There were no clear signs of pericardial tamponade either clinically or echocardiographically. Therefore, for further differential diagnosis, a contrast-enhanced computed tomography scan was performed under clinical suspicion of acute abdomen. Unexpectedly, active bleeding distally from the right coronary anastomosis was revealed. While the patient was prepared for operative revision, she needed cardiopulmonary resuscitation, which was successful. Intraoperatively, the source of bleeding was located and surgically relieved. The subsequent postoperative course was uneventful. CONCLUSIONS: In the first days after cardiac surgery, the occurrence of life-threatening situations, such as cardiac tamponade, must be expected. Especially if the symptoms are atypical, the entire diagnostic armamentarium must be applied to identify the origin of the complaints, which may be cardiac, but also non-cardiac. CENTRAL MESSAGE: A high level of suspicion, immediate diagnostic confirmation, and rapid treatment are required to recognize and successfully treat such an emergency (Fig. 5). PERSPECTIVE: Pericardial tamponade should always be considered as a complication of cardiac surgery, even when symptoms are atypical. The full range of diagnostic tools must be used to identify the origin of the complaints, which may be cardiac, but also non-cardiac (Fig. 5).


Subject(s)
Cardiac Surgical Procedures , Cardiac Tamponade , Female , Humans , Aged , Cardiac Tamponade/diagnosis , Cardiac Tamponade/etiology , Cardiac Tamponade/surgery , Pericardiocentesis/adverse effects , Heart , Cardiac Surgical Procedures/adverse effects , Tomography, X-Ray Computed/adverse effects
7.
J Fam Issues ; 44(1): 25-45, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36605179

ABSTRACT

Governments of numerous countries implemented school closures to contain the COVID-19 pandemic. Several investigations have shown the negative impact of social-distancing policies and school closures on children worldwide. Recently, research also demonstrated adverse effects on adults' well-being. The development of children is strongly affected by their parent's emotional state. The present study aimed to examine parental stress levels caused by a short period of homeschooling in December 2020 in Germany. A structured survey was set up and distributed randomly via social media and parent associations. We observed a significant increase in stress and concerns. Family conflicts significantly increased, social isolation was feared, and powerlessness and helplessness ascended. Risk factors were parental education levels, parental working time, and teaching features like the frequency of feedback, correction, and accessibility.

8.
Invest Radiol ; 58(3): 216-222, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36165876

ABSTRACT

OBJECTIVES: Presurgical identification and morphologic characterization of the peroneal perforator arteries (PPAs) are essential for osseomyocutaneous flap surgery. The aim of this study was to evaluate PPAs using time-of-flight (TOF) angiography in 7 T magnetic resonance imaging in comparison with dual-energy computed tomographic angiography (CTA). MATERIALS AND METHODS: In this prospective study, TOF angiography and CTA of both lower legs were acquired before flap surgery from 07/2019 to 02/2020. Magnetic resonance imaging was performed using a dedicated 28-channel knee coil with an acquisition time of 9:55 minutes (voxel size: 0.4 × 0.4 × 0.8 mm). Computed tomographic angiography was acquired with a third-generation dual-source computed tomography on the same day. Virtual monoenergetic reconstructions at 40 keV photon energy served as the standard of reference for PPA identification and subtyping. Two independent readers assessed the image quality, quantity, length assessment, and classification according to surgical considerations of PPAs for TOF angiography and CTA. Both TOF angiography and CTA were used for presurgical flap design and were evaluated by an orofacial surgeon. RESULTS: Ten patients (mean age, 59.9 ± 14.9 years; 7 men) were included. Time-of-flight angiography and CTA identified 53 and 51 PPAs in total, respectively. Time-of-flight angiography showed superior image quality (both readers, P < 0.05). Time-of-flight angiography enabled specific classification of PPA subtypes more often (53 vs 39; P < 0.05), and both readers reported higher diagnostic confidence for TOF angiography than CTA in all patients (interrater agreement κ = 0.8; P < 0.05). Regarding length assessment, PPAs were significantly more conspicuous with TOF angiography (TOF mean , 50 ± 11 mm; CTA mean , 40 ± 9 mm; P = 0.001). In comparison with CTA, TOF angiography prospectively changed the orofacial surgeon's final decision on the presurgical selected PPAs in 60% of cases. CONCLUSIONS: Presurgical assessment of PPAs is feasible using TOF in 7 T magnetic resonance imaging. Moreover, TOF angiography was superior to CTA for classifying and identifying PPAs, which may facilitate the planning of reconstructive surgery.


Subject(s)
Magnetic Resonance Angiography , Magnetic Resonance Imaging , Male , Humans , Middle Aged , Aged , Magnetic Resonance Angiography/methods , Prospective Studies , Computed Tomography Angiography/methods , Arteries
9.
Radiology ; 306(3): e221250, 2023 03.
Article in English | MEDLINE | ID: mdl-36125379

ABSTRACT

Background Long COVID occurs at a lower frequency in children and adolescents than in adults. Morphologic and free-breathing phase-resolved functional low-field-strength MRI may help identify persistent pulmonary manifestations after SARS-CoV-2 infection. Purpose To characterize both morphologic and functional changes of lung parenchyma at low-field-strength MRI in children and adolescents with post-COVID-19 condition compared with healthy controls. Materials and Methods Between August and December 2021, a cross-sectional clinical trial using low-field-strength MRI was performed in children and adolescents from a single academic medical center. The primary outcome was the frequency of morphologic changes at MRI. Secondary outcomes included MRI-derived functional proton ventilation and perfusion parameters. Clinical symptoms, the duration from positive reverse transcriptase-polymerase chain reaction test result, and serologic parameters were compared with imaging results. Nonparametric tests for pairwise and corrected tests for groupwise comparisons were applied to assess differences in healthy controls, recovered participants, and those with long COVID. Results A total of 54 participants after COVID-19 infection (mean age, 11 years ± 3 [SD]; 30 boys [56%]) and nine healthy controls (mean age, 10 years ± 3; seven boys [78%]) were included: 29 (54%) in the COVID-19 group had recovered from infection and 25 (46%) were classified as having long COVID on the day of enrollment. Morphologic abnormality was identified in one recovered participant. Both ventilated and perfused lung parenchyma (ventilation-perfusion [V/Q] match) was higher in healthy controls (81% ± 6.1) compared with the recovered group (62% ± 19; P = .006) and the group with long COVID (60% ± 20; P = .003). V/Q match was lower in patients with time from COVID-19 infection to study participation of less than 180 days (63% ± 20; P = .03), 180-360 days (63% ± 18; P = .03), and 360 days (41% ± 12; P < .001) as compared with the never-infected healthy controls (81% ± 6.1). Conclusion Low-field-strength MRI showed persistent pulmonary dysfunction in children and adolescents who recovered from COVID-19 and those with long COVID. Clinical trial registration no. NCT04990531 © RSNA, 2022 Supplemental material is available for this article. See also the editorial by Paltiel in this issue.


Subject(s)
COVID-19 , Adolescent , Adult , Child , Humans , Male , Cross-Sectional Studies , Lung/diagnostic imaging , Post-Acute COVID-19 Syndrome , SARS-CoV-2
10.
Insights Imaging ; 13(1): 164, 2022 Oct 11.
Article in English | MEDLINE | ID: mdl-36219277

ABSTRACT

BACKGROUND: To evaluate the feasibility and benefits of digitized informed patient consent (D-IPC) for contrast-enhanced CT and compare digitized documentation with paper-based, conventional patient records (C-PR). METHODS: We offered D-IPC to 2016 patients scheduled for a CT. We assessed patient history (e.g., CT examinations, malignant or cardiovascular diseases) and contraindications (red flags) for a CT (e.g., thyroid hyperfunction, allergies) using a tablet device. We evaluated the success rate of D-IPC and compared patient age between the subgroups of patients who were able or unable to complete D-IPC. We analyzed the prevalence of marked questions and red flags (RF). RF were compared with the documentation from C-PR. We estimated greenhouse gas (GHG) emissions for paperless workflow and provide a cost-benefit analysis. RESULTS: Overall, 84.4% of patients completed D-IPC. They were younger (median 61 years) than unsuccessful patients (65 years; p < 0.001). Patients who marked questions (21.7%) were older than patients without inquiries (median 63.9 vs 59.5 years; p < 0.001). The most prevalent RF was thyroid disease (23.8%). RF were considered critical for contrast-agent injection in 13.7%, requiring personalized preparation. The detection rate for RF documented with D-IPC was higher than for C-PR (n = 385 vs. 43). GHG emissions for tablet production are 80-90 times higher than for paper production. The estimated costs were slightly higher for D-IPC (+ 8.7%). CONCLUSION: D-IPC is feasible, but patient age is a relevant factor. Marked questions and RF help personalize IPC. The availability of patient history by D-IPC was superior compared to C-PR.

11.
Quant Imaging Med Surg ; 12(9): 4462-4473, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36060583

ABSTRACT

Background: There is limited information about perfusion in exercise-induced muscle injuries such as delayed-onset muscle soreness (DOMS) and the effect of compression garments as a therapeutic strategy during the regeneration phase. The purpose of this prospective, explorative study was to evaluate muscle perfusion in DOMS and to assess the effect of compression garments at resting conditions and during DOMS by magnetic resonance (MR) arterial spin labeling (ASL). Methods: DOMS was induced from 03/2021 to 04/2021 using an eccentric and plyometric exercises targeting the calf muscles in 14 volunteers. A compression garment (21-22 mmHg) was worn during and for 6 h after exercise on one randomized leg. Magnetic resonance imaging (MRI) including ASL of both lower legs was performed before and directly after the exercise as well as after 6 h, and 48 h using a 3 Tesla MRI system. Perfusion analyses of the gastrocnemius muscle (GM) and the tibialis anterior muscle (TA) were performed and results were compared to baseline measurements. T2-weighted images and creatine kinase levels were acquired at baseline and after 48 h. Results: All volunteers presented a successful induction of DOMS in the GM after 48 h. Arterial muscle perfusion in the GM increased from baseline to measurements taken directly after the exercise (4.97±5.59 mL/100 g/min, P<0.001). No significant alteration in perfusion compared to baseline was observed at 6 h (P=0.16) and 48 h (P=1.0) after the induction of DOMS. Compression garments did not elicit a significant alteration in ASL parameters in the GM (P=0.65) or the TA (P=0.05) at any time point. No adverse events occurred during the study. Conclusions: After an initial exercise-associated increase in arterial muscle perfusion, a normalization of blood supply was observed at 6 and 48 h after the exercise intervention inducing DOMS. Wearing a compression garment (21-22 mmHg) during and after the induction of DOMS did not affect muscle perfusion at rest, nor did it have any significant effect on muscle perfusion during the regeneration phase. The results can help to better understand the pathophysiological properties of DOMS and may have implications for diagnostic and therapeutic strategies.

12.
J Pers Med ; 12(5)2022 Apr 28.
Article in English | MEDLINE | ID: mdl-35629124

ABSTRACT

Background: Deep inferior epigastric perforator and muscle sparing transverse rectus abdominis muscle flaps are commonly used flaps for autologous breast reconstruction. CT-angiography allows to analyse the perforator course preoperatively. Our aim was to compare the different aspects of perforator anatomy in the most detailed study. Methods: CT-angiographies of 300 female patients with autologous breast reconstruction of 10 years were analysed regarding the anatomy of the deep inferior epigastric artery and every perforator. Results: Overall, 2260 perforators were included. We identified correlations regarding the DIEA branching point and number of perforators and their intramuscular course. The largest perforator emerged more often from the medial branch of the DIEA than the smaller perforators (70% (416/595) vs. 54% (878/1634), p < 0.001) and more often had a direct connection to the SIEV (large 67% (401/595) vs. small 39% (634/1634), p < 0.01). Medial row perforators were larger than the laterals (lateral 1.44 mm ± 0.43 (n = 941) vs. medial 1.58 mm ± 0.52 (n = 1304) (p < 0.001)). The larger and more medial the perforator, the more likely it was connected to the SIEV: perforators with direct connection to the SIEV had a diameter of 1.65 mm ± 0.53 (n = 1050), perforators with indirect connection had a diameter of 1.43 ± 0.43 (n = 1028), perforators without connection had a diameter of 1.31 mm ± 0.37 (n = 169) (p < 0.001). Medial perforators were more often directly connected to the SIEV than lateral perforators (medial 56% (723/1302) vs. lateral 35% (327/941), p < 0.001). A lateral perforator more often had a short intramuscular course than medial perforators (69% (554/800) vs. 45% (474/1055), p < 0.001), which was also more often observed in the case of a small perforator and a caudal exit of the rectus sheath. Conclusion: The largest perforator emerges more often from the medial branch of the DIEA and frequently has a direct connection to the SIEV, making medial row perforators ideal for DIEP flap transplantation.

13.
Radiologe ; 62(5): 410-417, 2022 May.
Article in German | MEDLINE | ID: mdl-35416477

ABSTRACT

BACKGROUND: Magnetic resonance imaging (MRI) plays a crucial role in musculoskeletal imaging. The high prevalence and pain-related suffering of patients pose a particular challenge concerning availability and turnover times, respectively. Low-field (≤ 1.0 T) MRI has the potential to fulfill these needs. However, during the past three decades, high field systems have increasingly replaced low field systems because of their limitations in image quality. Recent technological advancements in high-performance hard- and software promise musculoskeletal imaging with adequate quality at lower field strengths for several regions and indications. OBJECTIVES: The goal is to provide insight into the advantages and disadvantages of low-field musculoskeletal imaging, discuss the current literature, and include our first experiences with a modern 0.55 T MRI. MATERIALS AND METHODS: This review is based on research in various literature databases and our own musculoskeletal imaging experiences with a modern 0.55 T scanner. CONCLUSION: Most publications pertaining to musculoskeletal imaging at low-field strength MRI are outdated, and studies regarding the diagnostic performance of modern low-field MRI systems are needed. These new systems may complement existing high-field systems and make MRI more accessible, even in low-income countries. From our own experience, modern low-field MRI seems to be adequate in musculoskeletal imaging, especially in acute injuries.


Subject(s)
Magnetic Resonance Imaging , Musculoskeletal System , Humans , Magnetic Resonance Imaging/methods , Musculoskeletal System/diagnostic imaging , Software
14.
Radiologe ; 62(5): 418-428, 2022 May.
Article in German | MEDLINE | ID: mdl-35416476

ABSTRACT

BACKGROUND: Lung magnetic resonance imaging (MRI) examinations are challenging and have not become established in the routine clinical setting. Recent developments in low-field MRI, combined with computer-assisted algorithms for acquisition and evaluation, promise new perspectives for imaging of pulmonary diseases. OBJECTIVES: This review aims to inform about the physical advantages of low-field MRI for imaging the lungs, provide a review of the sparse literature, and present first results from a new low-field MRI scanner. MATERIALS AND METHODS: This article provides information on the physical principles, an review of the literature, and our first experiences in lung imaging on a modern 0.55 T MRI. CONCLUSION: Low-field MRI (< 1 T) may have technical and economic advantages over higher field strength MRI in lung imaging. The physical preconditions of low-field MRI are advantageous for imaging the lungs due to reduced susceptibility effects, increased transversal relaxation times, and lower specific absorption rates. The lower investment and operating costs may enable increased availability and sustainability. Combining modern sequences and computer-based image processing may expand beyond morphological imaging by providing spatially and temporally resolved functional examinations of the lung parenchyma without ionizing radiation. In critical scenarios, like screening and short-term follow-up examinations, and patients at risk, low-field MRI may bridge the gap. These indications may include acute and chronic pulmonary diseases in pediatric patients and suspected pulmonary embolisms in pregnant women.


Subject(s)
Lung Diseases , Magnetic Resonance Imaging , Child , Female , Humans , Image Processing, Computer-Assisted , Lung/diagnostic imaging , Lung/pathology , Lung Diseases/diagnostic imaging , Magnetic Resonance Imaging/methods , Pregnancy , Thorax
15.
J Plast Reconstr Aesthet Surg ; 75(2): 536-543, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34756655

ABSTRACT

BACKGROUND: Cinematic Rendering (CR) is a recently introduced post-processing three-dimensional (3D) visualization imaging tool. The aim of this study was to assess its clinical value in the preoperative planning of deep inferior epigastric artery perforator (DIEP) or muscle-sparing transverse rectus abdominis myocutaneous (MS-TRAM) flaps, and to compare it with maximum intensity projection (MIP) images. The study presents the first application of CR for perforator mapping prior to autologous breast reconstruction. METHODS: Two senior surgeons independently analyzed CR and MIP images based on computed tomography angiography (CTA) datasets of 20 patients in terms of vascular pedicle characteristics, the possibility to harvest a DIEP or MS-TRAM flap, and the side of the flap harvest. We calculated inter- and intra-observer agreement in order to examine the accordance of both image techniques. RESULTS: We observed a good inter- and intra-observer agreement concerning the type of flap and the side of the flap harvest. However, the agreement on the pedicle characteristics varies depending on the considered variable. Both investigators identified a significantly higher number of perforators with MIP compared with CR (observer 1, p<0.0001 and observer 2, p<0.0385). CONCLUSION: The current study serves as an explorative study, showing first experiences with CR in abdominal-based autologous breast reconstruction. In addition to MIP images, CR might improve the surgeon's understanding of the individual's anatomy. Future studies are required to compare CR with other 3D visualization tools and its possible effects on operative parameters.


Subject(s)
Mammaplasty , Myocutaneous Flap , Perforator Flap , Angiography , Epigastric Arteries/transplantation , Humans , Mammaplasty/methods , Myocutaneous Flap/transplantation , Perforator Flap/blood supply , Rectus Abdominis/blood supply , Retrospective Studies
16.
Diagnostics (Basel) ; 11(11)2021 Oct 26.
Article in English | MEDLINE | ID: mdl-34829336

ABSTRACT

Pulmonary arterial dual-energy (aDE) CT is an established technique for evaluating pulmonary perfusion blood volume (PBV). As DECT protocols are increasingly used for thoraco-abdominal CT, this study assessed image quality and clinical findings in portal-venous phase dual-energy (vDE) CT and compared it to aDE. In 95 patients, vDE-CT was performed using a dual-source scanner (70/Sn150 kV, 560/140 ref.mAs). Pulmonary triggered aDE-CT served as reference (n = 94). PBV was reconstructed using a dedicated algorithm. Mean relative attenuation was measured in the pulmonary trunk, aorta, and segmented lung parenchyma. A distribution ratio (DL) between vessels and parenchyma was calculated to assess the iodine uptake of the lung parenchyma. Subjective overall diagnostic image quality was assessed for PBV images on a five-point Likert scale. Image artifacts were classified into five groups based on scale rating and compared between vDE and aDE. Pathological findings were correlated with the anatomical image datasets. Mean relative attenuation of the lung parenchyma was comparable in both groups (vDE: 23 ± 6 HU and aDE: 22 ± 7 HU), but significantly lower in the vessels of vDE. Therefore, iodine uptake of the lung parenchyma was significantly higher in vDE (DL: 10% vs. 8%, p < 0.01). The subjective overall image quality of the PBV images was comparable (p = 0.5). Rotation and streak artifacts were found in most of the patients (>86%, both p > 0.6). Dual-source artifacts were found in only a few patients in both groups (vDE 5%, aDE 7%, p = 0.5). Recess and subpleural artifacts were increased in vDE (vDE 53/27%, aDE 24/7%, both p < 0.001). Pathological findings were found in 19% of the vDE patients and 59% of the aDE patients. Comparable objective and subjective image quality of lung perfusion can be obtained in vDE and aDE. Iodine uptake of the lung parenchyma is increased in vDE compared to aDE, suggesting an interstitial pooling effect. Knowledge of the different appearances of artifacts will aid in the interpretation of the images. Additional clinical information about the lung parenchyma can be provided by PBV evaluation in vDE.

17.
Diagnostics (Basel) ; 11(7)2021 Jul 06.
Article in English | MEDLINE | ID: mdl-34359298

ABSTRACT

For therapeutic decisions regarding uni- or biventricular surgical repair in congenital heart disease (CHD), left ventricular mass (LVM) is an important factor. The aim of this retrospective study was to determine the LVM of infants with CHD in thoracic computed tomography angiographies (CTAs) and to evaluate its usefulness as a prognostic parameter, with special attention paid to hypoplastic left heart (HLH) patients. Manual segmentation of the left ventricular endo- and epicardial volumes was performed in CTAs of 132 infants. LVMs were determined from these volumes and normalized to body surface area. LVMs of patients with different types of CHD were compared to each other using analyses of variances (ANOVA). An LVM cutoff for discrimination between uni- and biventricular repair was determined using receiver operating characteristics. Survival rates were calculated using Kaplan-Meier statistics. Patients with a clinical diagnosis of an HLH had significantly lower mean LVM (21.88 g/m2) compared to patients without applicable disease (50.22 g/m2; p < 0.0001) and compared to other CHDs, including persistent truncus arteriosus, left ventricular outflow tract obstruction, transposition of the great arteries, pulmonary artery stenosis or atresia, and double-outlet right ventricle (all, p < 0.05). The LVM cutoff for uni- vs. biventricular surgery was 33.9 g/m2 (sensitivity: 82.3%; specificity: 73.7%; PPV: 94.9%). In a subanalysis of HLH patients, a sensitivity of 50.0%, specificity of 100%, PPV of 100%, and NPV of 83.3% was determined. Patient survival was not significantly different between the surgical approaches or between patients with LVM above or below the cutoff. LVM can be measured in chest CTA of newborns with CHD and can be used as a prognostic factor.

18.
Pediatr Radiol ; 50(9): 1240-1248, 2020 08.
Article in English | MEDLINE | ID: mdl-32556576

ABSTRACT

BACKGROUND: Radiation dose at CT should be as low as possible without compromising diagnostic quality. OBJECTIVE: To assess the potential for maximum dose reduction of pediatric lung dual-source CT with spectral shaping and advanced iterative reconstruction (ADMIRE). MATERIALS AND METHODS: We retrospectively analyzed dual-source CT acquisitions in a full-dose group (FD: 100 kV, 64 reference mAs) and in three groups with spectral shaping and differing reference mAs values (Sn: 100 kV, 96/64/32 reference mAs), each group consisting of 16 patients (age mean 11.5 years, standard deviation 4.8 years, median 12.8 years, range 1.3-18 years). Advanced iterative reconstruction of images was performed with different strengths (FD: ADMIRE Level 2; Sn: ADMIRE Levels 2, 3 and 4). We analyzed dose parameters and measured noise. Diagnostic confidence and detectability of lung lesions as well as anatomical structures were assessed using a Likert scale (from 1 [unacceptable] to 4 [fully acceptable]). RESULTS: Compared to full dose, effective dose was reduced to 16.7% in the Sn 96 group, 11.1% in Sn64, and 5.5% in Sn32 (P<0.001). Noise values of Sn64ADM4 did not statistically differ from those in FDADM2 (45.7 vs. 38.9 Hounsfield units [HU]; P=0.132), whereas noise was significantly higher in Sn32ADM4 compared to Sn64ADM4 (61.5 HU; P<0.001). A Likert score >3 was reached in Sn64ADM4 regarding diagnostic confidence (3.2) and detectability of lung lesions (3.3). For detectability of most anatomical structures, no significant differences were found between FDAM2 and Sn64ADM4 (P≥0.05). CONCLUSION: In pediatric lung dual-source CT, spectral shaping together with ADMIRE 4 enable radiation dose reduction to about 10% of a full-dose protocol while maintaining an acceptable diagnostic quality.


Subject(s)
Lung Diseases/diagnostic imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed/methods , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Male , Retrospective Studies
19.
J Cardiovasc Comput Tomogr ; 13(4): 226-233, 2019.
Article in English | MEDLINE | ID: mdl-30737152

ABSTRACT

BACKGROUND: Aim of this study was to assess the accuracy of ventricular septal defects (VSD) using high pitch computed tomography angiography (CTA) of the chest in children below 1 year of age, compared to the intraoperative findings and echocardiography. METHODS: Out of 154 patients that underwent Dual-Source CTA of the chest using a high-pitch protocol at low tube voltages (70-80 kV), 55 underwent surgical repair of a VSD (median age 8 days, range 1-348 days). The margins of the VSDs and their relation to the surrounding structures were reproduced by en-face views using multiplanar reformations (MPR). Absolute diameter, normalized area and relative area compared to the aortic valve annulus were used for discrimination between restrictive and non-restrictive defects. Localization was classified into four subtypes. The results were compared to two-dimensional echocardiography and intraoperative findings. RESULTS: Median absolute size of VSDs did not differ significantly between CTA-measurements (10.8 mm, range 2.8-18.1 mm) and intraoperative findings (12.0 mm, 3.0-25.0 mm, p = 0.09). Echocardiographic values were significantly lower (9.6 mm, 3.0-18.5 mm, both p < 0.01). The classification of the location and orientation matched the intraoperative situs in 96.4% of all cases using CT and in 87.3% using echocardiography. Echocardiography missed the relation to valves in 11% of all cases. Pre-interventional sensitivity and specificity for detection of a VSD were 97.2/98.9% compared to echocardiography. Median radiation dose was 0.32 mSv (range 0.12-2.00 mSv) and differed significantly between second and third generation Dual-Source CT (0.43 vs. 0.22 mSv, p = 0.003). CONCLUSION: Size and subtype of VSDs can be accurately assessed by CTA of the chest in patients with complex congenital heart defects at a very low radiation dose.


Subject(s)
Computed Tomography Angiography , Coronary Angiography/methods , Heart Septal Defects, Ventricular/diagnostic imaging , Age Factors , Echocardiography , Heart Septal Defects, Ventricular/surgery , Humans , Infant , Infant, Newborn , Predictive Value of Tests , Radiation Dosage , Radiation Exposure , Reproducibility of Results , Retrospective Studies
20.
Radiol Cardiothorac Imaging ; 1(3): e180017, 2019 Aug.
Article in English | MEDLINE | ID: mdl-33778508

ABSTRACT

PURPOSE: To compare free-breathing (FB) stress cardiac MRI examinations with the reference standard breath-holding (BH) examination. MATERIALS AND METHODS: A total of 40 consecutive patients were enrolled prospectively and were examined with 3-T MRI. Functional imaging, perfusion, and late gadolinium enhancement (LGE) sequences were performed in BH and FB by using compressed sensing and in-line motion correction. Left ventricle (LV) and right ventricle (RV) functional parameters in BH and FB examinations were compared by using Bland-Altman plots and linear mixed models. Subjective image quality was assessed with a five-point scale (1 = nondiagnostic, 5 = very good). For perfusion and LGE imaging, diagnostic confidence was rated with a three-point scale (1 = low, 3 = high), and image quality was rated with a five-point scale (1 = nondiagnostic, 5 = very good). The Wilcoxon test was used to compare image quality and diagnostic confidence. RESULTS: Bland-Altman plots showed good agreement for LV and RV functional parameters in BH and FB sequences. Subjective image quality was significantly better with the BH sequences in the LV (P < .01) but was comparable in the RV (P > .99). Scanning time was 218 seconds (range, 130-385 seconds) for cine BH and 16 seconds (range, 11-27 seconds) for cine FB. Extent of perfusion defects, LGE, and diagnostic confidence was comparable between groups. Scanning time was 371 seconds (range, 239-502 seconds) for the LGE BH sequence and 189 seconds (range, 122-286 seconds) for the LGE FB sequence. CONCLUSION: FB adenosine stress cardiac MRI delivers diagnostic image quality and could represent an alternative for use in patients who are unable to meet the demands of multiple BHs and long examination times.© RSNA, 2019.