Clin Orthop Relat Res ; 479(3): 613-619, 2021 03 01.
Article in English | MEDLINE | ID: mdl-33009232

ABSTRACT

BACKGROUND: Early administration of antibiotics and wound coverage have been shown to decrease the deep infection risk in all patients with Type 3 open tibia fractures. However, it is unknown whether early antibiotic administration decreases infection risk in patients with Types 1, 2, and 3A open tibia fractures treated with primary wound closure. QUESTIONS/PURPOSES: (1) Does decreased time to administration of the first dose of antibiotics decrease the deep infection risk in all open tibia fractures with primary wound closure? (2) What patient demographic factors are associated with an increased deep infection risk in Types 1, 2, and 3A open tibia fractures with primary wound closure? METHODS: We identified 361 open tibia fractures over a 5-year period at a Level I regional trauma center that receives direct admissions and transfers from other hospitals which produces large variation in the timing of antibiotic administration. Patients were excluded if they were younger than 18 years, had associated plafond or plateau fractures, associated with compartment syndrome, had a delay of more than 24 hours from injury to the operating room, underwent repeat débridement procedures, had incomplete data, and were treated with negative-pressure dressings or other adjunct wound management strategies that would preclude primary closure. Primary closure was at the descretion of the treating surgeon. We included patients with a minimum follow-up of 6 weeks with assessment at 6 months and 12 months. One hundred forty-three patients with were included in the analysis. Our primary endpoint was deep infection as defined by the CDC criteria. We obtained chronological data, including the time to the first dose of antibiotics and time to surgical débridement from ambulance run sheets, transferring hospital records, and the electronic medical record to answer our first question. We considered demographics, American Society of Anesthesiologists classification, mechanism of injury, smoking status, presence of diabetes, and Injury Severity Score in our analysis of other factors. These were compared using one-way ANOVA, chi-square, or Fisher's exact tests. Binary regression was used to to ascertain whether any factors were associated with postoperative infection. Receiver operator characteristic curves were used to identify threshold values. RESULTS: Increased time to first administration of antibiotics was associated with an increased infection risk in patients who were treated with primary wound closure; the greatest inflection point on that analysis occurred at 150 minutes, when the increased infection risk was greatest (20% [8 of 41] versus 4% [3 of 86]; odds ratio 5.6 [95% CI 1.4 to 22.2]; p = 0.01). After controlling for potential confounding variables like age, diabetes and smoking status, none of the variables we evaluated were associated with an increased risk of deep infection in Type 1, 2, and 3A open tibia fractures in patients treated with primary wound closure. CONCLUSION: Our findings suggest that in open tibia fractures, which receive timely antibiotic administration, primary wound closure is associated with a decreased infection risk. We recognize that more definitive studies need to be performed to confirm these findings and confirm feasibility of early antibiotic administration, especially in the pre-hospital context. LEVEL OF EVIDENCE: Level III, therapeutic study.


Subject(s)
Anti-Bacterial Agents/administration & dosage , Antibiotic Prophylaxis/methods , Fractures, Open/surgery , Surgical Wound Infection/prevention & control , Tibial Fractures/surgery , Wound Closure Techniques , Adult , Female , Humans , Male , Negative-Pressure Wound Therapy , Open Fracture Reduction/adverse effects , Open Fracture Reduction/methods , Retrospective Studies , Risk Factors , Surgical Wound Infection/etiology , Tibia/surgery , Time Factors , Treatment Outcome
3.
J Arthroplasty ; 31(8): 1746-9, 2016 08.
Article in English | MEDLINE | ID: mdl-26948131

ABSTRACT

BACKGROUND: Periprosthetic joint infection (PJI) is one of the most common causes of revision total hip arthroplasty (THA) and associated with higher costs, prolonged pain, and worse clinical outcomes. Many factors have been linked to increased infection rates, one being the operative equipment and instrumentation used during the surgical procedure. With few arthroplasty instruments designed for complete disassembly and increasingly complex instrument designs, this study seeks to understand the effect that instrument disassembly plays on infection using disassembled and assembled standard femoral broach handles (BHs). METHODS: Two BHs, not designed for disassembly, were modified and then contaminated in the disassembled state with Geobacillus stearothermophilus vegetative-form bacteria and spores. Using both flash and standard sterilization cycles, the BHs were steam sterilized in the disassembled or assembled state and then analyzed for remaining bacteria and spores. RESULTS: At all target locations after either a flash sterilization cycle or a standard sterilization cycle, complete eradication of both the vegetative-form and spore-form of G stearothermophilus was achieved. CONCLUSION: This study demonstrates that adequate decontamination of the tested BHs can be achieved after steam sterilization in either the disassembled or assembled state, without an increased risk of infection transmission.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Equipment Contamination/statistics & numerical data , Sterilization/methods , Geobacillus stearothermophilus , Humans , Risk , Surgical Instruments
4.
J Arthroplasty ; 29(6): 1219-24, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24444570

ABSTRACT

Stepped porous titanium metaphyseal sleeves may provide an option for enhanced fixation in managing challenging tibial defects in revision total knee arthroplasty (TKA). We retrospectively reviewed data on 51 patients who underwent revision TKA utilizing a metaphyseal sleeve for Anderson Orthopaedic Research Institute (AORI) Type II and III tibial defects between June 2007 and July 2011. Of these 51 patients, 36 patients had complete clinical and radiographic data. At final follow-up (mean: 38 months) significant improvements in knee range of motion and Knee Society scores were observed postoperatively (P < 0.001). Four revision procedures were necessary, but none for aseptic implant fixation failure. Radiographic review at final follow-up revealed stable, osteointegrated components without component migration or clinically significant osteolysis. Metaphyseal sleeve use in the management of moderate to severe tibial defects in revision TKA resulted in satisfactory clinical outcomes and is a versatile option for achieving stable fixation.


Subject(s)
Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/instrumentation , Bone Resorption/surgery , Aged , Aged, 80 and over , Biocompatible Materials , Female , Humans , Knee Joint/surgery , Knee Prosthesis , Male , Middle Aged , Prosthesis Design , Reoperation , Tibia/surgery , Titanium
SELECTION OF CITATIONS