Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 152
Filter
1.
Article in English | MEDLINE | ID: mdl-38795093

ABSTRACT

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.

2.
Medicina (Kaunas) ; 60(5)2024 May 16.
Article in English | MEDLINE | ID: mdl-38793002

ABSTRACT

Over the past decade, remote monitoring (RM) has become an increasingly popular way to improve healthcare and health outcomes. Modern cardiac implantable electronic devices (CIEDs) are capable of recording an increasing amount of data related to CIED function, arrhythmias, physiological status and hemodynamic parameters, providing in-depth and updated information on patient cardiovascular function. The extensive use of RM for patients with CIED allows for early diagnosis and rapid assessment of relevant issues, both clinical and technical, as well as replacing outpatient follow-up improving overall management without compromise safety. This approach is recommended by current guidelines for all eligible patients affected by different chronic cardiac conditions including either brady- and tachy-arrhythmias and heart failure. Beyond to clinical advantages, RM has demonstrated cost-effectiveness and is associated with elevated levels of patient satisfaction. Future perspectives include improving security, interoperability and diagnostic power as well as to engage patients with digital health technology. This review aims to update existing data concerning clinical outcomes in patients managed with RM in the wide spectrum of cardiac arrhythmias and Hear Failure (HF), disclosing also about safety, effectiveness, patient satisfaction and cost-saving.


Subject(s)
Heart Failure , Humans , Heart Failure/therapy , Heart Failure/diagnosis , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Monitoring, Physiologic/methods , Telemedicine/trends , Defibrillators, Implantable/standards
5.
Article in English | MEDLINE | ID: mdl-38625833

ABSTRACT

BACKGROUND: Atrioventricular block (AVB) is a frequent complication in patients undergoing transcatheter aortic valve implantation (TAVI). Right apex ventricular pacing (RVP) represents the standard treatment but may induce cardiomyopathy over the long term. Left bundle branch area pacing (LBBAP) is a promising alternative, minimizing the risk of desynchrony. However, available evidence with LBBAP after TAVI is still low. OBJECTIVE: To assess the feasibility and safety of LBBAP for AVB post-TAVI compared with RVP. METHODS: Consecutive patients developing AVB early after TAVI were enrolled between 1 January 2022 and 31 December 2022 at three high-volume hospitals and received LBBAP or RVP. Data on procedure and at short-term follow-up (at least 3 months) were collected. RESULTS: A total of 38 patients (61% men, mean age 83 ±â€Š6 years) were included; 20 patients (53%) received LBBAP. Procedural success was obtained in all patients according to chosen pacing strategy. Electrical pacing performance at implant and after a mean follow-up of 4.2 ±â€Š2.8 months was clinically equivalent for both pacing modalities. In the LBBAP group, procedural time was longer (70 ±â€Š17 versus 58 ±â€Š15 min in the RVP group, P = 0.02) and paced QRS was shorter (120 ±â€Š19 versus 155 ±â€Š12 ms at implant, P < 0.001; 119 ±â€Š18 versus 157 ±â€Š9 ms at follow-up, P < 0.001). Complication rates did not differ between the two groups. CONCLUSION: In patients with AVB after TAVI, LBBAP is feasible and safe, resulting in a narrow QRS duration, either acutely and during the follow-up, compared with RVP. Further studies are needed to evaluate if LBBAP reduces pacing-induced cardiomyopathy in this clinical setting.

6.
Clin Case Rep ; 12(4): e8745, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38659502

ABSTRACT

A 46-year-old woman with congenitally corrected transposition of the great arteries (ccTGA) associated with dextrocardia, situs viscerus inversus, and left superior vena cava persistence presented with an incessant supraventricular tachycardia. Electrophysiological study was not conclusive in differential diagnosis of atrial tachycardia versus atypical atrioventricular (AV) nodal reentrant tachycardia, also due to the unconventional anatomy of the coronary sinus. By a comprehensive mapping of cardiac chambers, a double side slow-pathway was localized in both atrial chambers and subsequently ablated by radiofrequency delivery without tachycardia changes. Aortic root and cusps were devoid of electrical activity. The muscular part of the sub-pulmonary ventricle at the level of interatrial septum showed an earliest activation signal of -90 ms and ablation of this site was effective in abolish the tachycardia. This is the first case to report technical concerns of septal atrial tachycardia ablation in ccTGA associated with multiple anatomical malformations. Moreover, some peculiarities have been reported for the first time including the presence of double-side AV nodal slow-pathway and atypical localization of the tachycardia origin into the muscular part of the sub-pulmonary ventricle instead of posterior pulmonary cusp.

7.
Can J Cardiol ; 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38492735

ABSTRACT

BACKGROUND: In patients with atrial fibrillation (AF) on vitamin K antagonist (VKA) therapy and therapeutic international normalized ratio (INR) range, the incidence of cardiac thromboembolism is not negligible, and the subgroup of patients who have a mechanical prosthetic mitral valve (PMV) has the highest risk. We aimed to assess the long-term effects of left atrial appendage closure (LAAC) in AF patients with a mechanical PMV who experienced a failure of VKA therapy. METHODS: In this retrospective, multicentre study, patients underwent LAAC because of thrombotic events including transient ischemic attack and/or stroke, systemic embolism, and evidence of left atrial appendage thrombosis and/or sludge, despite VKA therapy, were enrolled. Patients with a mechanical PMV were included and compared with those affected by nonvalvular AF. The primary endpoint was the composite of all-cause death, major cardiovascular events, and major bleedings at follow-up. The feasibility and safety of LAAC also were assessed. RESULTS: A total of 55 patients (42% female; mean age, 70 ± 9 years), including 12 with a mechanical PMV, were enrolled. The most-frequent indication to LAAC (71%) was LAA thrombosis or sludge. Procedural success was achieved in 96% of overall cases, and in 100% of patients with a PMV. In 35 patients, a cerebral protection device was used. During a median follow-up of 6.1 ± 4.3 years, 4 patients with a PMV, and 20 patients without a PMV, reported adverse events (hazard ratio 0.73 [95% confidence interval 0.25-2.16, P = 0.564]). CONCLUSIONS: LAAC seems to be a valuable alternative in patients with AF who have a mechanical PMV, with failure of VKA therapy. This off-label, real-world clinical practice indication deserves validation in further studies.

8.
J Clin Med ; 13(2)2024 Jan 14.
Article in English | MEDLINE | ID: mdl-38256590

ABSTRACT

Arrhythmogenic cardiomyopathy (ACM) is a heart disease characterized by a fibrotic replacement of myocardial tissue and a consequent predisposition to ventricular arrhythmic events, especially in the young. Post-mortem studies and the subsequent diffusion of cardiac MRI have shown that left ventricular involvement in arrhythmogenic cardiomyopathy is common and often develops early. Regarding the arrhythmic risk stratification, the current scores underestimate the arrhythmic risk of patients with arrhythmogenic cardiomyopathy with left involvement. Indeed, the data on arrhythmic risk stratification in this group of patients are contradictory and not exhaustive, with the consequence of not correctly identifying patients at a high arrhythmic risk who deserve protection from arrhythmic death. We propose a literature review on arrhythmic risk stratification in patients with ACM and left involvement to identify the main features associated with an increased arrhythmic risk in this group of patients.

9.
Diagnostics (Basel) ; 14(2)2024 Jan 14.
Article in English | MEDLINE | ID: mdl-38248058

ABSTRACT

Fluoroscopy has always been the cornerstone imaging method of interventional cardiology procedures. However, radiation exposure is linked to an increased risk of malignancies and multiorgan diseases. The medical team is even more exposed to X-rays, and a higher incidence of malignancies was reported in this professional group. In the last years, X-ray exposure has increased rapidly, involving, above all, the medical team and young patients and forcing alternative fluoroless imaging methods. In cardiac electrophysiology (EP) and pacing, the advent of 3D electroanatomic mapping systems with dedicated catheters has allowed real-time, high-density reconstruction of both heart anatomy and electrical activity, significantly reducing the use of fluoroscopy. In addition, the diffusion of intracardiac echocardiography has provided high anatomical resolution of moving cardiac structures, providing intraprocedural guidance for more complex catheter ablation procedures. These methods have largely demonstrated safety and effectiveness, allowing for a dramatic reduction in X-ray delivery in most arrhythmias' ablations. However, some technical concerns, as well as higher costs, currently do not allow their spread out in EP labs and limit their use to only procedures that are considered highly complex and time-consuming and in young patients. In this review, we aim to update the current employment of fluoroless imaging in different EP procedures, focusing on its strengths and weaknesses.

11.
Clin Kidney J ; 16(12): 2683-2692, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38046009

ABSTRACT

Background: The prevalence of atrial fibrillation (AF) in end stage kidney disease (ESKD) patients undergoing dialysis is high, however, the high risk of bleeding often hampers with a correct anticoagulation in ESKD patients with AF, despite high thromboembolic risk. Left atrial appendage (LAA) occlusion is a anticoagulation (OAT) for thromboembolism prevention in AF populations with high hemorrhagic risk. Methods and Results: The purpose of the study was to evaluate the efficacy and safety of LAA occlusion in a cohort of dialysis patients undergoing the procedure (LAA occlusion cohort, n = 106), in comparison with two other ESKD cohorts, one taking warfarin (Warfarin cohort, n = 114) and the other without anticoagulation therapy (No-OAT cohort, n = 148). After a median follow-up of 4 years, a Cox regression model, adjusted for possible confounding factors, showed that the hazard ratios (HRs) of thromboembolic events in the LAA occlusion cohort were 0.19 (95%CI 0.04-0.96; p = 0.045) and 0.16 (95%CI 0.04-0.66; p = 0.011) as compared with Warfarin and No-OAT cohorts, respectively. The HR of bleeding in the LAA occlusion cohort was 0.37 (95%CI 0.16-0.83; p = 0.017) compared to Warfarin cohort, while there were no significant differences between the LAA occlusion and the No-OAT cohort (HR 0.51; 95%CI 0.23-1.12; p = 0.094). Adjusted Cox regression models showed lower mortality in patients undergoing LAA occlusion as compared with both the Warfarin cohort (HR 0.60; 95%CI 0.38-0.94; p = 0.027) and no-OAT cohort (HR 0.52; 95%CI 0.34-0.78; p = 0.002). Thromboembolic events in the LAA occlusion cohort were lower than expected according to the CHA2DS2VASc score (1.7 [95%CI 0.3-3.0] vs 6.7 events per 100 person/years, p < 0.001). Conclusion: In ESKD patients with AF, LAA occlusion is safe and effective and is associated with reduced mortality compared with OAT or no therapy.

12.
J Clin Med ; 12(20)2023 Oct 20.
Article in English | MEDLINE | ID: mdl-37892796

ABSTRACT

This study aimed to compare the peri-procedural success and complication rate within a large registry of intra-cardiac echocardiography (ICE)- vs. transesophageal echocardiography (TEE)-guided left atrial appendage occlusion (LAAO) procedures with a Watchmann FLX device. Data from 772 LAAO procedures, performed at 26 Italian centers, were reviewed. Technical success was considered as the final implant of a Watchmann FLX device in LAA; the absence of pericardial tamponade, peri-procedural stroke and/or systemic embolism, major bleeding and device embolization during the procedure was defined as a procedural success. One-year stroke and major bleeding rates were evaluated as outcome. ICE-guided LAA occlusion was performed in 149 patients, while TEE was used in 623 patients. Baseline characteristics were similar between the ICE and TEE groups. The technical success was 100% in both groups. Procedural success was also extremely high (98.5%), and was comparable between ICE (98.7%) and TEE (98.5%). ICE was associated with a slightly longer procedural time (73 ± 31 vs. 61.9 ± 36 min, p = 0.042) and shorter hospital stay (5.3 ± 4 vs. 5.8 ± 6 days, p = 0.028) compared to the TEE group. At one year, stroke and major bleeding rates did not differ between the ICE and TEE groups. A Watchmann FLX device showed high technical and procedural success rate, and ICE guidance does not appear inferior to TEE.

13.
Life (Basel) ; 13(9)2023 Aug 28.
Article in English | MEDLINE | ID: mdl-37763223

ABSTRACT

Intraprocedural stroke is a well-documented and feared potential risk of cardiovascular transcatheter procedures (TPs). Moreover, subclinical neurological events or covert central nervous system infarctions are concerns related to the development of dementia, future stroke, cognitive decline, and increased risk of mortality. Cerebral protection devices (CPDs) were developed to mitigate the risk of cardioembolic embolism during TPs. They are mechanical barriers designed to cover the ostium of the supra-aortic branches in the aortic arch, but newer devices are able to protect the descending aorta. CPDs have been mainly designed and tested to provide cerebral protection during transcatheter aortic valve replacement (TAVR), but their use in both Catheterization and Electrophysiology laboratories is rapidly increasing. CPDs have allowed us to perform procedures that were previously contraindicated due to high thromboembolic risk, such as in cases of intracardiac thrombosis identified at preprocedural assessment. However, several concerns related to their employment have to be defined. The selection of patients at high risk of thromboembolism is still a subjective choice of each center. The aim of this review is to update the evidence on the use of CPDs in either Cath labs or EP labs, providing an overview of their structural characteristics. Future perspectives focusing on their possible future employment are also discussed.

15.
J Am Coll Cardiol ; 82(18): 1765-1773, 2023 10 31.
Article in English | MEDLINE | ID: mdl-37611779

ABSTRACT

BACKGROUND: The optimal antithrombotic therapy following left atrial appendage occlusion (LAAO) in patients with nonvalvular atrial fibrillation (AF) remains uncertain. OBJECTIVES: In this study, the authors sought to compare the efficacy and safety of various antithrombotic strategies after LAAO. METHODS: We searched the Medline, Cochrane, EMBASE, LILACS, and ClinicalTrials.gov databases for studies reporting outcomes after LAAO, stratified by antithrombotic therapy prescribed at postprocedural discharge. Direct oral anticoagulants (DOACs), vitamin K antagonists (VKAs), single antiplatelet therapy (SAPT), dual antiplatelet therapy (DAPT), DOAC plus SAPT, VKA plus SAPT, and no antithrombotic therapy were analyzed. We performed a frequentist random effects model network meta-analysis to estimate the OR and 95% CI for each comparison. P-scores provided a ranking of treatments. RESULTS: Forty-one studies comprising 12,451 patients with nonvalvular AF were included. DAPT, DOAC, DOAC plus SAPT, and VKA were significantly superior to no therapy to prevent device-related thrombosis. DOAC was associated with lower all-cause mortality than VKA (OR: 0.39; 95% CI: 0.17-0.89; P = 0.03). Compared with SAPT, DAPT was associated with fewer thromboembolic events (OR: 0.50; 95% CI: 0.29-0.88; P = 0.02), without a difference in major bleeding. In the analysis of P-scores, DOAC monotherapy was the strategy most likely to have lower thromboembolic events and major bleeding. CONCLUSIONS: In this network meta-analysis comparing initial antithrombotic therapies after LAAO, monotherapy with DOAC had the highest likelihood of lower thromboembolic events and major bleeding. DAPT was associated with a lower incidence of thromboembolic events compared with SAPT and may be a preferred option in patients unable to tolerate anticoagulation.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thromboembolism , Humans , Platelet Aggregation Inhibitors , Fibrinolytic Agents/therapeutic use , Atrial Appendage/surgery , Network Meta-Analysis , Anticoagulants , Hemorrhage/etiology , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Thromboembolism/epidemiology , Thromboembolism/etiology , Thromboembolism/prevention & control , Stroke/etiology , Treatment Outcome
16.
Life (Basel) ; 13(8)2023 Jul 28.
Article in English | MEDLINE | ID: mdl-37629509

ABSTRACT

The difference between subcutaneous implantable cardioverter defibrillators (S-ICDs) and transvenous ICDs (TV-ICDs) concerns a whole extra thoracic implantation, including a defibrillator coil and pulse generator, without endovascular components. The improved safety profile has allowed the S-ICD to be rapidly taken up, especially among younger patients. Reports of its role in different cardiac diseases at high risk of SCD such as hypertrophic and arrhythmic cardiomyopathies, as well as channelopathies, is increasing. S-ICDs show comparable efficacy, reliability, and safety outcomes compared to TV-ICD. However, some technical issues (i.e., the inability to perform anti-bradycardia pacing) strongly limit the employment of S-ICDs. Therefore, it still remains only an alternative to the traditional ICD thus far. This review aims to provide a contemporary overview of the role of S-ICDs compared to TV-ICDs in clinical practice, including technical aspects regarding device manufacture and implantation techniques. Newer outlooks and future perspectives of S-ICDs are also brought up to date.

17.
Int J Cardiol ; 389: 131188, 2023 10 15.
Article in English | MEDLINE | ID: mdl-37453454

ABSTRACT

BACKGROUND: LAAO is an emerging option for thromboembolic event prevention in patients with NVAF. We previously reported data on comparison between LAAO and DOAC at two-year follow-up in NVAF patients at HBR (HAS-BLED ≥3). AIMS: Limited data are available on long term follow-up. We aimed to evaluate the efficacy and safety of DOACs versus LAAO indication after 5 years. METHODS: We enrolled 193 HBR treated with LAAO and 189 HBR patients with DOACs. At baseline, LAAO group had higher HAS-BLED (4.2 vs 3.3, p < 0.001) and lower CHADS-VASc (4.3 vs. 4.7, p = 0.005). After 1:1 PSM, 192 patients were included (LAAO n = 96; DOACs n = 96). RESULTS: At 5-year follow-up the rate of the combined safety and effectiveness endpoint (ISTH major bleeding and thromboembolic events) was significantly higher in LAAO group (p = 0.042), driven by a higher number of thromboembolic events (p = 0.047). The rate of ISTH-major bleeding events was similar (p = 0.221). After PSM no significant difference in the primary effectiveness (LAAO 13.3% vs DOACs 9.5%, p = 0.357) and safety endpoint (LAAO 7.5% vs DOACs 7.5%; p = 0.918) were evident. Overall bleeding rate was significantly higher in DOACs group (25.0% vs 13.7%, p = 0.048), while a non-significant higher number of TIA was reported in LAAO group (5.4% vs 1.1%, p = 0.098). All-cause and cardiovascular mortality were higher in LAAO group at both unmatched and matched analysis. CONCLUSION: We confirmed safety and effectiveness of both DOAC and LAAO in NVAF patients at HBR, with no significant differences in thromboembolic events or major bleeding were at 5-year follow-up. The observed increased mortality after LAAO warrants further investigations in RCTs.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thromboembolism , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Atrial Appendage/surgery , Hemorrhage/chemically induced , Anticoagulants/adverse effects , Thromboembolism/epidemiology , Thromboembolism/etiology , Thromboembolism/prevention & control , Treatment Outcome
18.
J Clin Med ; 12(11)2023 Jun 05.
Article in English | MEDLINE | ID: mdl-37298059

ABSTRACT

Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and predisposes patients to an increased risk of cardioembolic events (CE), such as ischemic stroke, TIA, or systemic embolism [...].

19.
Front Cardiovasc Med ; 10: 1172005, 2023.
Article in English | MEDLINE | ID: mdl-37383696

ABSTRACT

Background: Percutaneous left atrial appendage occlusion (LAAO) presents many technical complex features, and it is often performed under the intraprocedural surveillance of a product specialist (PS). Our aim is to assess whether LAAO is equally safe and effective when performed in high-volume centers without PS support. Methods: Intraprocedural results and long-term outcome were retrospectively assessed in 247 patients who underwent LAAO without intraprocedural PS monitoring between January 2013 and January 2022 at three different hospitals. This cohort was then matched to a population who underwent LAAO with PS surveillance. The primary end point was all-cause mortality at 1 year. The secondary end point was a composite of cardiovascular mortality plus nonfatal ischemic stroke occurrence at 1 year. Results: Of the 247 study patients, procedural success was achieved in 243 patients (98.4%), with only 1 (0.4%) intraprocedural death. After matching, we did not identify any significant difference between the two groups in terms of procedural time (70 ± 19 min vs. 81 ± 30 min, p = 0.106), procedural success (98.4% vs. 96.7%, p = 0.242), and procedure-related ischemic stroke (0.8% vs. 1.2%, p = 0.653). Compared to the matched cohort, a significant higher dosage of contrast was used during procedures without specialist supervision (98 ± 19 vs. 43 ± 21, p < 0.001), but this was not associated with a higher postprocedural acute kidney injury occurrence (0.8% vs. 0.4%, p = 0.56). At 1 year, the primary and the secondary endpoints occurred in 21 (9%) and 11 (4%) of our cohort, respectively. Kaplan-Meier curves showed no significant difference in both primary (p = 0.85) and secondary (p = 0.74) endpoint occurrence according to intraprocedural PS monitoring. Conclusions: Our results show that LAAO, despite the absence of intraprocedural PS monitoring, remains a long-term safe and effective procedure, when performed in high-volume centers.

20.
J Clin Med ; 12(12)2023 Jun 17.
Article in English | MEDLINE | ID: mdl-37373791

ABSTRACT

BACKGROUND: The brain and heart are strictly linked and the electrical physiologies of these organs share common pathways and genes. Epilepsy patients have a higher prevalence of electrocardiogram (ECG) abnormalities compared to healthy people. Furthermore, the relationship between epilepsy, genetic arrhythmic diseases and sudden death is well known. The association between epilepsy and myocardial channelopathies, although already proposed, has not yet been fully demonstrated. The aim of this prospective observational study is to assess the role of the ECG after a seizure. MATERIALS AND METHODS: From September 2018 to August 2019, all patients admitted to the emergency department of San Raffaele Hospital with a seizure were enrolled in the study; for each patient, neurological, cardiological and ECG data were collected. The ECG was performed at the time of the admission (post-ictal ECG) and 48 h later (basal ECG) and analyzed by two blinded expert cardiologists looking for abnormalities known to indicate channelopathies or arrhythmic cardiomyopathies. In all patients with abnormal post-ictal ECG, next generation sequencing (NGS) analysis was performed. RESULTS: One hundred and seventeen patients were enrolled (females: 45, median age: 48 ± 12 years). There were 52 abnormal post-ictal ECGs and 28 abnormal basal ECGs. All patients with an abnormal basal ECG also had an abnormal post-ictal ECG. In abnormal post-ictal ECG, a Brugada ECG pattern (BEP) was found in eight patients (of which two had BEP type I) and confirmed in two basal ECGs (of which zero had BEP type I). An abnormal QTc interval was identified in 20 patients (17%), an early repolarization pattern was found in 4 patients (3%) and right precordial abnormalities were found in 5 patients (4%). Any kind modification of post-ictal ECG was significantly more pronounced in comparison with an ECG recorded far from the seizure (p = 0.003). A 10:1 higher prevalence of a BEP of any type (particularly in post-ictal ECG, p = 0.04) was found in our population compared to general population. In three patients with post-ictal ECG alterations diagnostic for myocardial channelopathy (BrS and ERP), not confirmed at basal ECG, a pathogenic gene variant was identified (KCNJ8, PKP2 and TRMP4). CONCLUSION: The 12-lead ECG after an epileptic seizure may show disease-related alterations otherwise concealed in a population at a higher incidence of sudden death and channelopathies. Post-ictal BEP incidence was higher in cases of nocturnal seizure.

SELECTION OF CITATIONS
SEARCH DETAIL
...