Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Coll Surg ; 219(4): 620-30, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25158914

ABSTRACT

BACKGROUND: After portal vein embolization (PVE), the future liver remnant (FLR) hypertrophies for several weeks. An early marker that predicts a low risk of post-hepatectomy liver failure can reduce the delay to surgery. STUDY DESIGN: Liver volumes of 153 patients who underwent a major hepatectomy (>3 segments) after PVE for primary or secondary liver malignancy between September 1999 and November 2012 were retrospectively evaluated with computerized volumetry. Pre- and post-PVE FLR volume and functional liver volume were measured. Degree of hypertrophy (DH = post-FLR/post-functional liver volume - pre-FLR/pre-functional liver volume) and growth rate (GR = DH/weeks since PVE) were calculated. Postoperative complications and liver failure were correlated with DH, measured GR, and estimated GR derived from a formula based on body surface area. RESULTS: Eligible patients underwent 93 right hepatectomies, 51 extended right hepatectomies, 4 left hepatectomies, and 5 extended left hepatectomies. Major complications occurred in 44 patients (28.7%) and liver failure in 6 patients (3.9%). Nonparametric regression showed that post-embolization FLR percent correlated poorly with liver failure. Receiver operating characteristic curves showed that DH and GR were good predictors of liver failure (area under the curve [AUC] = 0.80; p = 0.011 and AUC = 0.79; p = 0.015) and modest predictors of major complications (AUC = 0.66; p = 0.002 and AUC = 0.61; p = 0.032). No patient with GR >2.66% per week had liver failure develop. The predictive value of measured GR was superior to estimated GR for liver failure (AUC = 0.79 vs 0.58; p = 0.046). CONCLUSIONS: Both DH and GR after PVE are strong predictors of post-hepatectomy liver failure. Growth rate might be a better guide for the optimum timing of liver resection than static volumetric measurements. Measured volumetrics correlated with outcomes better than estimated volumetrics.


Subject(s)
Embolization, Therapeutic/methods , Hepatectomy/adverse effects , Liver Failure/prevention & control , Liver Neoplasms/surgery , Liver/pathology , Postoperative Complications , Aged , Female , Follow-Up Studies , Humans , Hypertrophy , Liver Failure/diagnosis , Liver Failure/etiology , Magnetic Resonance Imaging , Male , Middle Aged , Portal Vein , Prognosis , ROC Curve , Retrospective Studies , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...