Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Vet Immunol Immunopathol ; 148(3-4): 267-75, 2012 Aug 15.
Article in English | MEDLINE | ID: mdl-22682231

ABSTRACT

The purpose of this study was to evaluate the reproducibility of results yielded using a monoclonal antibody based ELISA for detection of allergen specific IgE when run in six separate affiliated laboratories. On two separate occasions, duplicate samples of 15 different sera pools were independently evaluated by each laboratory in a single blinded fashion. The average intra-assay variance among reactive assay calibrators in all laboratories was 6.2% (range 2.6-18.2%), while the average intra-laboratory inter-assay variance was 12.1% (range 8.0-17.1%). The overall inter-assay inter-laboratory variance was consistent among laboratories and averaged 15.6% (range 15.1-16.6%). All laboratories yielded similar profiles and magnitudes of responses for replicate unknown samples; dose-response profiles observed in each of the laboratories were indistinguishable. Considering positive/negative results, inter-assay inter-laboratory concordance of results exceeded 95%. Correlation of OD values between and among all laboratories was strong (r>0.9, p<0.001). Correlation of OD values between the two separate evaluations was also high for all allergens except olive, which was attributed to lot-to-lot differences of allergen coated wells. Collectively, the results demonstrated that the monoclonal antibody based ELISA for measuring allergen specific canine IgE is reproducible, and documents that consistency of results can be achieved not only in an individual laboratory, but between laboratories using the same monoclonal-based ELISA.


Subject(s)
Antibodies, Monoclonal , Enzyme-Linked Immunosorbent Assay/veterinary , Immunoglobulin E/immunology , Allergens/immunology , Animals , Dog Diseases/blood , Dog Diseases/immunology , Dogs/blood , Dogs/immunology , Dose-Response Relationship, Immunologic , Enzyme-Linked Immunosorbent Assay/methods , Hypersensitivity/blood , Hypersensitivity/immunology , Hypersensitivity/veterinary , Immunoglobulin E/blood , Reproducibility of Results
2.
Vet Dermatol ; 20(3): 157-64, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19374726

ABSTRACT

The purpose of this study was to define the operational and performance characteristics of a commercially available monoclonal antibody based (mac) ELISA for detection of allergen-specific IgE in dogs. The average intra-assay variance over 1 year was 9.7% (range 2.5-62.7%), while the interassay variance averaged 10.8% (range 8.1-13.8%). The average positive control responses observed for grass, weed, tree and mite allergens during each month remained relatively constant; the average monthly variance was 11.6% (range 8.3-19.2%) for grass pollens, 13.3% (range 9.1-20.4%) for weed pollens, 13.3% (range 9.8-18.2%) for tree pollens and 13.6% (range 8.9-18.7%) for mite allergens. The interlaboratory concordance of results for the macELISA was approximately 91%. The interlaboratory concordance of results comparing the macELISA and a high affinity IgE receptor-based ELISA was approximately 92%. The results demonstrate that the macELISA is reproducible and the results are comparable to the high affinity IgE receptor based ELISA within and between laboratories.


Subject(s)
Allergens/immunology , Antibodies, Monoclonal , Dermatitis, Atopic/veterinary , Dog Diseases/diagnosis , Enzyme-Linked Immunosorbent Assay/veterinary , Immunoglobulin E/immunology , Animals , Calibration , Clinical Laboratory Techniques/standards , Clinical Laboratory Techniques/veterinary , Dermatitis, Atopic/diagnosis , Dermatitis, Atopic/immunology , Dog Diseases/immunology , Dogs , Enzyme-Linked Immunosorbent Assay/standards , Immunoglobulin E/blood , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL