Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Opt ; 61(22): 6430-6442, 2022 Aug 01.
Article in English | MEDLINE | ID: mdl-36255867

ABSTRACT

Modern grating manufacturing techniques suffer from inherent issues that limit their peak efficiencies. The anisotropic etching of silicon facilitates the creation of custom gratings that have sharp and atomically smooth facets, directly addressing these issues. We describe work to fabricate and characterize etched silicon echelles optimized for the far ultraviolet (FUV; 90-180 nm) bandpass. We fabricate two echelles that have parameters similar to the mechanically ruled grating flown on the Colorado High-resolution Echelle Stellar Spectrograph sounding rocket. We demonstrate a 42% increase in peak order efficiency and an 83% decrease in interorder scatter using these gratings. We also present analysis on where the remaining efficiency resides. These demonstrated FUV echelle improvements benefit the faint source sensitivity and high resolution performance of future UV observatories.

2.
Appl Opt ; 57(3): 454-464, 2018 Jan 20.
Article in English | MEDLINE | ID: mdl-29400795

ABSTRACT

Off-plane x-ray reflection gratings are theoretically capable of achieving high resolution and high diffraction efficiencies over the soft x-ray bandpass, making them an ideal technology to implement on upcoming x-ray spectroscopy missions. To achieve high effective area, these gratings must be aligned into grating modules. X-ray testing was performed on an aligned grating module to assess the current optical alignment methods. Results indicate that the grating module achieved the desired alignment for an upcoming x-ray spectroscopy suborbital rocket payload with modest effective area and resolving power. These tests have also outlined a pathway towards achieving the stricter alignment tolerances of future x-ray spectrometer payloads, which require improvements in alignment metrology, grating fabrication, and testing techniques.

3.
Appl Opt ; 55(21): 5548-53, 2016 Jul 20.
Article in English | MEDLINE | ID: mdl-27463903

ABSTRACT

Off-plane reflection gratings were previously predicted to have different efficiencies when the incident light is polarized in the transverse-magnetic (TM) versus transverse-electric (TE) orientations with respect to the grating grooves. However, more recent theoretical calculations which rigorously account for finitely conducting, rather than perfectly conducting, grating materials no longer predict significant polarization sensitivity. We present the first empirical results for radially ruled, laminar groove profile gratings in the off-plane mount, which demonstrate no difference in TM versus TE efficiency across our entire 300-1500 eV bandpass. These measurements together with the recent theoretical results confirm that grazing incidence off-plane reflection gratings using real, not perfectly conducting, materials are not polarization sensitive.